• Title/Summary/Keyword: high-frequency effects

Search Result 1,806, Processing Time 0.029 seconds

A Study on The characteristics based on the stauration effects of traction motor for korea High Speed Train (한국형 고속전철용 견인전동기의 포화현상에 따른 특성연구)

  • 이상우;김근웅;윤종학;한성수
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.360-367
    • /
    • 1999
  • An inverter-driven induction motor is used as the traction motor for a high speed drive system that required safety, reliabillity, performance, compact size owing to the space and weight alloted for attaching to train, etc. particularly it is possible to happen the saturation effects of flux density at constant voltage-frequency region and then increase very higher than the at lowed capacity of no-load current and temperature in any case. therefore the optimum design of core, optimum voltage-frequency ratio, adoption of high grade magnetic core have been developed and researched for preventing these problems. this paper show the saturation effects of traction rotor by measuring the induced voltage of search coil at stator teeth and presents optimum voltage-frequency ratio as well as optimum core design through the comparison with efficiency, power factor, load current and no-load current for korea high speed train.

  • PDF

The Short-Term Effects of Difference Frequency of Transcutaneous Electrical Nerve Stimulation on Pain Relief using c-fos Expression in Spinal Cord with Knee Osteoarthritis Rats

  • Koo, Hyun-Mo;Na, Sang-Su
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.4
    • /
    • pp.49-54
    • /
    • 2016
  • PURPOSE: The purpose of this study was to determine the effect of different frequencies (4Hz and 100Hz) of transcutaneous electrical nerve simulation (TENS) on pain relief using c-fos expression in the spinal cord of rat osteoarthritis to investigate the appropriate frequency for pain relief. METHODS: Total of 30 Sprague-Dawley rats was used and randomly divided 2 groups according TENS frequency and applicate the TENS during 3 period (3 days, 7 days, 10 days). The induction of osteoarthritis by 3mg monosodium iodoacetat was injected into the right knee joint of rats. Three days later, commercially available TENS unit was used for stimulation was set to 20minutes on 3, 7, 10 days after surgery. Western blot analysis system was used to detect immunoreactive proteins. The thickness of the bands were photographically measured by Scion Image. RESULTS: When investigating the c-fos expression of TENS on spinal cord in OA knee over 10 days, between-groups differences in c-fos expression reached a significant level by day 10. For within-groups comparisons, the c-fos expression decreased significantly across days in low- and high-frequency TENS groups. CONCLUSION: Whether at low- and high-frequency, the TENS as a therapy obtained beneficial effects of pain relief and TNES at high-frequency is more beneficial effects on the pain relief when TENS applied at injury site.

High Frequency Circuit Design using Feedback Control with Body Load Fluctuation for Pain Relief Therapy (통증 완화 치료기용 인체 부하 변동에 따른 피드백 제어가 가능한 고주파 회로 설계)

  • Park, Chul-Won;Won, Chul-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.45-49
    • /
    • 2013
  • High frequency system has been used for the purpose of skin care and obesity treatment, by high-frequency energy is applied to the human body generates deep heat. Conventional high frequency system could not selection control by depending on the body load fluctuations. Such as burns and side effects have been reported by system instability and then therapeutic effect is insufficient. During treatment, objective information about the status of the patient was no. Because of treatment methods are subjective, and so tailored treatments were impossible. In this paper, high frequency medical system with sinusoidal frequency characteristics without distortion of the Push pull switching scheme for pain relief therapy was designed. And control circuit that was designed by feedback using the output changes according to the body-load fluctuation. Last, power circuit for efficient control the heat generated from the hardware was proposed.

Effects of Word Frequency on a Lenition Process: Evidence from Stop Voicing and /h/ Reduction in Korean

  • Choi, Tae-Hwan;Lim, Nam-Sil;Han, Jeong-Im
    • Speech Sciences
    • /
    • v.13 no.3
    • /
    • pp.35-48
    • /
    • 2006
  • The present study examined whether words with higher frequency have more exposure to the lenition process such as intervocalic stop voicing or /h/ reduction in the production of the Korean speakers. Experiment 1 and Experiment 2 tested if word-internal intervocalic voicing and /h/ reduction occur more often in the words with higher frequency than less frequent words respectively. Results showed that the rate of voicing was not significantly different between the high frequency group and the low frequency group; rather both high and low frequency words were shown to be fully voiced in this prosodic position. However, intervocalic /h/s were deleted more in high frequency words than in low frequency words. Low frequency words showed that other phonetic variants such as [h] and [w] were found more often than in high frequency group. Thus the results of the present study are indefinitive as to the relationship between the word frequency and lenition with the data at hand.

  • PDF

Experimental Study on High Frequency Vibration Transfer Characteristic of Underwater Cylindrical Shell (수중 원통형 쉘 구조물의 고주파 진동 전달특성에 대한 실험적 연구)

  • Jung, Hyung-Gi;Min, Cheon-Hong;Park, Han-Il
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.58-63
    • /
    • 2011
  • Underwater vehicles such as UUVs (Unmanned Underwater Vehicles) and ROVs (Remotely Operated Vehicles) use sonar to detect their underwater environment or other underwater vehicles. The underwater vehicles designed recently have an electrical power system with high rotational speed. This system can generate high frequency vibrations above 10 kHz, and these vibrations can cause bad (negative) effects on the performance of the sonar. In many previous investigations, numerical analyses have been used for high frequency vibration problems. In this study, an experimental analysis was carried out, and a circular cylindrical shell was considered as the hull structure of an underwater vehicle. Frequency transfer functions for the circular cylindrical shell were identified using an experimental vibration analysis in the air and in a fully-submerged condition. We compare the frequency transfer functions in the air and water to obtain hydro-elastic effects. It is found that the dynamic characteristics of the circular cylindrical shell are changed by varying the response position.

The Power of Simultaneous Multi-frequency Observations for mm-VLBI: Beyond Frequency Phase Transfer

  • Zhao, Guang-Yao;Algaba, Juan Carlos;Lee, Sang Sung;Jung, Taehyun;Dodson, Richard;Rioja, Maria;Byun, Do-Young;Hodgson, Jeffrey;Kang, Sincheol;Kim, Dae-Won;Kim, Jae-Young;Kim, Jeong-Sook;Kim, Soon-Wook;Kino, Motoki;Miyazaki, Atsushi;Park, Jong-Ho;Trippe, Sascha;Wajima, Kiyoaki
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.46.2-46.2
    • /
    • 2017
  • Atmospheric propagation effects at millimeter wavelengths can significantly alter the phases of radio signals and reduce the coherence time, putting tight constraints on high frequency Very Long Baseline Interferometry (VLBI) observations. In previous works it has been shown that non-dispersive (e.g. tropospheric) effects can be calibrated with the frequency phase transfer (FPT) technique. The coherence time can thus be significantly extended. Ionospheric effects, which can still be significant, remain however uncalibrated after FPT, as well as the instrumental effects. In this work, we implement a further phase transfer between two FPT residuals (i.e. so-called FPT2) to calibrate the ionospheric effects based on their frequency dependence. We show that after FPT2, the coherence time at 3 mm can be further extended beyond 8 hours, and the residual phase errors can be sufficiently canceled by applying the calibration of another source, which can have a large angular separation from the target (> $20{\circ}$). Calibrations for all-sky distributed sources with a few calibrators are also possible after FPT2. One of the strengths and uniqueness of this calibration strategy is the suitability for high frequency all-sky survey observations including very weak sources. We discuss the introduction of a pulse calibration system in the future to calibrate the remaining instrumental effects and allowing the possibility of imaging the source structure at high frequencies with FPT2, where all phases are fully calibrated without involving any sources other than the target itself.

  • PDF

Frequency Effects of Upstream Wake and Blade Interaction on the Unsteady Boundary Layer Flow

  • Kang, Dong-Jin;Bae, Sang-Su
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1303-1313
    • /
    • 2002
  • Effects of the reduced frequency of upstream wake on downstream unsteady boundary layer flow were simulated by using a Wavier-Stokes code. The Wavier-Stokes code is based on an unstructured finite volume method and uses a low Reynolds number turbulence model to close the momentum equations. The geometry used in this paper is the MIT flapping foil experimental set-up and the reduced frequency of the upstream wake is varied in the range of 0.91 to 10.86 to study its effect on the unsteady boundary layer flow. Numerical solutions show that they can be divided into two categories. One is so called the low frequency solution, and behaves quite similar to a Stokes layer. Its characteristics is found to be quite similar to those due to either a temporal or spatial wave. The low frequency solutions are observed clearly when the reduced frequency is smaller than 3.26. The other one is the high frequency solution. It is observed for the reduced frequency larger than 7.24. It shows a sudden shift of the phase angle of the unsteady velocity around the edge of the boundary layer. The shift of phase angle is about 180 degree, and leads to separation of the boundary layer flow from corresponding outer flow. The high frequency solution shows the characteristics of a temporal wave whose wave length is half of the upstream frequency. This characteristics of the high frequency solution is found to be caused by the strong interaction between unsteady vortices. This strong interaction also leads to destroy of the upstream wake strips inside the viscous sublayer as well as the buffer layer.

The Effects of Muscle Fatigue by Transcutaneous Electrical Nerve Stimulation (경피신경전기자극이 근피로에 미치는 영향)

  • Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.1
    • /
    • pp.71-77
    • /
    • 1999
  • The purpose of this study was to investigate the changes of muscle power by transcutaneous electrical nerve stimulation(TBNS), low frequency-low intensity(20pps, invisible muscle contraction intensity), low frequency-high intensity(20pps, visible muscle contraction), high frequency-low intensity(100pps, invisible muscle contraction intensity) and high frequency-high intensity(100pps, visible muscle contraction). The results were as follows. 1. Increased muscle power after 30 minutes of treatment by low frequency-low intensity TENS, and post-treatment 30 minutes muscle power were increased more than pre-treatment power(p<0.05). 2. Decreased muscle power after a 30 minute treatment by low frequency-high intensity TENS, and after the 30 minute treatment was terminated muscle power didn't recover to pre-treatment levels. 3. Decreased muscle power after 30 minute treatment by high frequency-low intensity TENS, but post-treatment 30 minute, muscle power didn't recover to pre-treatment levels. 4. The muscle power was remarkably decreased by high frequency-high intensity TENS after 30 minute treatment, in addition treatment terminated after 30minutes didn,t recover to pre-treatment power(p<0.05). 5. Lower frequency-low intensity TENS are good methods for preventing muscle fatigue, buty high intensity (TENS) are increased muscle fatigue. 6. Traditional TENS by high frequency-low intensity is a good method for preventing muscle fatigue.

  • PDF

Effects of Frequency Characteristics of High Frequency-Hydraulic System for the Changes of Accumulators (축압기의 변화가 고주파 유압시스템의 주파수 특성에 미치는 영향)

  • Roh, Hyung-Woon;Kim, Jae-Soo;Park, Nam-Eun;Kim, Yang-Soo;Jeon, Seung-Bae;Na, Hong-Chul
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1936-1941
    • /
    • 2003
  • Characteristics of the high frequency and pulsatile flow investigated experimentally to understand the flow phenomena in the hydraulic system. In the study, I axis fatigue tester which are widely used for automobile filed are selected. 4 Pressure transducer, amplifier, A/D convertor are used to analyse and to obtain the pulsatle pressure waveform with high frequencies in hydraulic system. Matlab are used. to analyse the characteristics of frequency. Variation of pump input pressure and actuator acceleration frequency, pressure wave are measured with or without accumulators. For with accumulator, frequency amplitude of pressure are very lower than those of without accumulator due to absorbing function of accumulator. As the actuator acceleration frequency increased, effect of accumulator are very important to decrease the pulsatile pressure waveform with high frequencies.

  • PDF

Thermal characteristics according to the preload and cooling conditions for the high frequency motor spindle with grease lubrication (그리스 윤활 고주파 모터 주축의 예압과 냉각에 따른 열특성)

  • 최대봉;김수태;정성훈;김용기
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.439-444
    • /
    • 2004
  • The important problem in high speed spindle is to reduce and minimize the thermal effect by motor and ball bearings. In this study. the effects of bearing preload and cooling for high speed spindle with high frequency motor are investigated. A high speed spindle is composed of angular contact ball bearings, high frequency motor, grease lubrication, oil jacket cooling, and so on. Heat generation of the bearing and the high frequency motor are estimated from the theoretical and experimental data. The thermal analyses of high speed spindle to minimize the thermal effect and maximize the cooling effect are carried out under the various cooling conditions and preload. Method of variable bearing preload and cooling can be useful to design the high speed motor spindle. The results show that the optimal preload and cooling are very effective to minimize the thermal displacement by motor and ball bearing.

  • PDF