• 제목/요약/키워드: high-frequency effects

검색결과 1,806건 처리시간 0.027초

$CaF_2$가 Filler로 첨가된 유리복합체의 고주파 유전특성 (High Frequency Dielectric Properties of $CaF_2$ filled Glass-Composites)

  • 김선영;이경호;김성원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.277-281
    • /
    • 2003
  • Effects of $CaF_2$ addition as a filler on the high frequency dielectric properties and sintering of CaO-$Al_2O_3-SiO_2-B_2O_3$(CASB) and ZnO-MgO-$B_2O_3-SiO_2$(ZMBS) glass composites were investigated. The optimal glass composition in the CASB system was 33.0CaO-$17.0Al_2O_3-35.0SiO_2-15.0B_O_3$(in wt%). The corresponding dielectric properties were k=8.1 and $Q{\times}fo$=1,200GHz. The sintering temperature was $800{\mu}m$. In case of 2MBS system, 25.0ZnO-25.0MgO-20.0$B_2O_3-30.0SiO_2$(in wt%) glass showed k=6.8 and $Q{\times}fo$=5,200GHz when it was sintered at $750^{\circ}C$. The maximum amount of $CaF_2$ in the CASB and 2MBS glass system without any detrimental effect on the sintering was 25.0 v/o and 15.0 v/o, respectively. The addition of $CaF_2$ in the glass systems improved the high frequency dielectric properties. In case of CASB+$CaF_2$ composite, k was 7.1 and $Q{\times}fo$ was 2,300GHz. And in case of 2MBS+$CaF_2$ composite, k was 5.9 and $Q{\times}fo$ was 8,100GHz. $CaF_2$ addition also reduced sintering temperature. Effects of $CaF_2$ on the dielectric and sintering properties was analyzed in terms of viscosity and crystallization behavior changes due to the interaction between $CaF_2$ and the glass systems.

  • PDF

주파수 통과대역필터가 작업 기억 관련 사건관련전위 P300에 미치는 영향 (Effects of the Frequency Band Pass Filter on the P300 Event-related Potential in the Working Memory)

  • 박웅식;이정우
    • 대한통합의학회지
    • /
    • 제8권2호
    • /
    • pp.131-138
    • /
    • 2020
  • Purpose : The purpose of this study was to investigate the effects of the frequency band pass filter on the P300 event-related potential in the working memory. Methods : The subjects were 20 women in their 20s who applied for participation in the experiment. Event-related potentials (ERPs) were elicited using 3-back tasks for the working memory, and were recorded from Fz, Cz, and Pz scalp electrodes. The high-pass filters were set to 0.01, 0.1, and 0.3 Hz for analysis purposes, and the low-pass filters were set to 30 and 15 Hz. The 3-back task was presented for a total of 100 times, among which 30 times were designated for the target stimulation (a matched number) and 70 times for the non-target stimulation (an unmatched number). The temporal interval between each stimulation was set at 1 second, while each time duration was randomly presented between 2 to 4 seconds. ERP were analyzed for the P300 recorded from Fz, Pz and Cz scalp electrodes. Results : Latency and amplitude had no significant interaction effects in both the high- and low-pass filters. For the main effects, the latency and amplitude of the P300 event-related potential had no significant difference in the high-pass filters, but the latency had a significant difference in the low-pass filter of Fz, and the amplitude had a significant difference in the low-pass filter of Pz. Conclusion : The results of this study showed that the less than 0.3 Hz high filters had no effects on the differences between the latency and amplitude of the P300 event-related potential in the working memory. The 30Hz low-pass filter, however, was found to be useful for recording the P300 event-related potential in the working memory.

Harmonic Analysis of the Effects of Inverter Nonlinearity on the Offline Inductance Identification of PMSMs Using High Frequency Signal Injection

  • Wang, Gaolin;Wang, Ying;Ding, Li;Yang, Lei;Ni, Ronggang;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1567-1576
    • /
    • 2015
  • Offline inductance identification of a permanent magnet synchronous motor (PMSM) is essential for the design of the closed-loop controller and position observer in sensorless vector controlled drives. On the base of the offline inductance identification method combining direct current (DC) offset and high frequency (HF) voltage injection which is fulfilled at standstill, this paper investigates the inverter nonlinearity effects on the inductance identification while considering harmonics in the induced HF current. The negative effects on d-q axis inductance identifications using HF signal injection are analyzed after self-learning of the inverter nonlinearity characteristics. Then, both the voltage error and the harmonic current can be described. In addition, different cases of voltage error distribution with different injection conditions are classified. The effects of inverter nonlinearities on the offline inductance identification using HF injection are validated on a 2.2 kW interior PMSM drive.

Wind-induced response of structurally coupled twin tall buildings

  • Lim, Juntack;Bienkiewicz, Bogusz
    • Wind and Structures
    • /
    • 제10권4호
    • /
    • pp.383-398
    • /
    • 2007
  • The paper describes a study of the effects of structural coupling on the wind-induced response of twin tall buildings connected by a skybridge. Development of a dual high-frequency force balance used in wind tunnel investigation and background information on the methodology employed in analysis are presented. Comparisons of the wind-induced building response (rooftop acceleration) of structurally coupled and uncoupled twin buildings are provided and the influence of structural coupling is assessed. It is found that the adverse aerodynamic interference effects caused by close proximity of the buildings can be significantly reduced by the coupling. Neglecting of such interactions may lead to excessively conservative estimates of the wind-induced response of the buildings. The presented findings suggest that structural coupling should be included in wind-resistant design of twin tall buildings.

VSI-IM 구동시스템의 고동작 및 고주파영향 최소화를 위한 MM PWM 방식 (MM PWM Scheme for High Performance and Harmonic Effects Minimization of VSI-IM Drive System)

  • Min Soo Kim
    • 대한전자공학회논문지
    • /
    • 제25권1호
    • /
    • pp.42-48
    • /
    • 1988
  • MM(multimode) PWM(pulse width modulation) Suitable for high performance and harmonic effects minimization of VSI (voltabge source invertetr)-IM (induction motor)drive system is proposed. The approximated optimal, suboptimal and optimal PWM are implemented in the low frequency range, while square wave operation is realized in the hibh frequency range. The pulse width Modulator is capable of generating control signals to a transistorized inverter operating at about 1KHz. All functions except digital comparison have been implemented in softyware making the scheme economical, flexible and reliable. Pulse width modulator is built and tested experimentally. In order to confirm the effectiveness and the reliability of the theoretical proposition, this scheme is applied to 1Hp, Three phase IM. As results, it is concluded that the scheme of MM PWM is superior to other conventional switching scheme through the discussions or analysis carried out on the items such as line-to-line voltage, current and spectrum of current harmonic components observed at the output terminal of inverter, noise level of motor.

  • PDF

Respiratory Review of 2013: Critical Care Medicine

  • Choi, Hye Sook
    • Tuberculosis and Respiratory Diseases
    • /
    • 제75권1호
    • /
    • pp.1-8
    • /
    • 2013
  • Several papers on respiratory and critical care published from March 2012 to February 2013 were reviewed. From these, this study selected and summarized ten articles, in which the findings were notable, new, and interesting: effects of high-frequency oscillation ventilation on acute respiratory distress syndrome (ARDS); safety and efficacy of hydroxyethyl starch as a resuscitation fluid; long-term psychological impairments after ARDS; safety and efficacy of dexmedetomidine for sedation; B-type natriuretic peptide-guided fluid management during weaning from mechanical ventilation; adding of daily sedation interruptions to protocolized sedations for mechanical ventilation; unassisted tracheostomy collar of weaning from prolonged mechanical ventilations; and effects of nighttime intensivist staffing on the hospital mortality rates.

초고주파소자의 저가 플라스틱 실장을 위한 접지된 본딩와이어의 기생특성 해석 (Parasitics analysis of a grounded bondwire for low-cost plastic packaging of microwave devices)

  • 윤상기;이해영
    • 전자공학회논문지D
    • /
    • 제34D권2호
    • /
    • pp.21-26
    • /
    • 1997
  • The dielectric effects on the parasitics of bondwires buried in slightly-lossy dielectric materials hav been investigated over a wide frequency range using the method of moments with incorporation of ohmic and dielectric losses. The FR-4 composite is widely used as a basis material for PCB and plastic packages, because of it sinherent electricl and chemical stbility and low cost. The cole-cole model, which is representative complex permittivity model of epoxy polymers, has been applied to consider the dielectric effects in the MoM calculation. The prasitic impedance of a grounded bondwire in FR-4 composite is greatly increased due to the dielectric loading effect enhanced by the radiation at high frequencies. These calculation results will be helpful for designing and packaging of high-frequency low-cost IC's.

  • PDF

Effects of Asymmetric Airway Inertance on Mean Lung Volume During High Frequency Ventilation(HFV)

  • Cha, Eun-Jong
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권2호
    • /
    • pp.203-208
    • /
    • 1990
  • A possible asymmetry in airway inertance was modeled based on previously reported radiographic visualization data of the airway wall fluctuation in intact dogs. Effects of asymmetric Inertance on mean lung volume during high frequency ventilation (HFV) were evaluated in terms of mean inertive pressure drop across the airways. It was found that a negligible inertlve pressure drop was expected ($<1{\;}cmH_20$) in normal subjects, while a sig- nificant rise in mean alveolar pressure compared to mean mouth pressure by approximately $3{\;}cmH_20$ was resulted for about 40% airway fluctuation representing bronchoconstriction state by Histamine induction. These results demonstrate that asymmetric Inertance could lead patients with airway diseases to a significant lung hyperinflation (LHI), and bronchodilation treatment is recommended prior to applying HFV to prevent those patients from a possible barotrauma.

  • PDF

콘크리트 궤도 유형별 진동성능평가에 대한 연구 (A Study on Evaluation of Vibration Reduction Effect of Concrete tracks)

  • 양신추;김은;강윤석;엄주환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.911-916
    • /
    • 2002
  • One of important roles of concrete track is to reduce vibration transmitting to subgrade. In this paper, a numerical method for evaluating the effects of vibration reduction of concrete track is presented. Using the method, high frequency dynamic analyses and track-tunnel-soil interaction analyses are carried out for three types of concrete track in order to investigate the vibration reduction effects compared with normal ballast track.

  • PDF

경부고속철도 주변의 60 Hz 전자계 분포 예측에 관한 연구경부고속철도 (Calculation of Power Frequency Electromagnetic Field Around the Kyeongbu High Speed Railways)

  • 김응식;명성호;이병윤;한인수;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1648-1650
    • /
    • 1997
  • The effects of power frequency electric and magnetic fields have been a source of concern for many years. Electromagnetic fields can pose a theat to both signal system of electrified railways and human body around railways. It is believed that, though the electromagnetic fields do no serious harm to human health, they do induce biological effects. This paper estimates the electromagnetic fields near Kyeongbu high speed railways with numerical data. The charge simulation method and surface charge method are used to calculate the electric field of 2 dimensional power distribution lines and rails and magnetic field is calculated on the base of Biot-Sarart's law.

  • PDF