• Title/Summary/Keyword: high-frequency components

Search Result 994, Processing Time 0.031 seconds

A Study on the Vibration Analysis of Multi-components Damaged Ball Bearing under Radial Load (반경하중을 받는 결함 볼베어링의 진동해석에 관한 연구)

  • 김영주;전효중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.35-45
    • /
    • 1988
  • In this paper an experimental review of condition monitoring method using time domain vibration signals and statically measured wave forms of a multi-components damaged ball bearing is presented first time. Many investigators studied already about vibration characteristics of a single point damaged ball bearing but they did not make efforts to verify vibration phenomena of a multi-components damaged one. Even in case of a tripple components damaged (i.e, outer race, inner race and rolling element) one, the high frequency resonance technique (HERT) and the displacement time domain technique can be also used for its fault detection. According to experimental results undertaken a static displacement measuring method, the defect locations of components can be proposed confidently with simple calculation of the rotating angles of each component.

  • PDF

Residents' Attitudes for the components of Home Environment (주거환경 구성요소에 대한 거주자들의 태도에 관한 연구)

  • 조성희;강혜경
    • Journal of the Korean housing association
    • /
    • v.11 no.1
    • /
    • pp.45-56
    • /
    • 2000
  • This study is to find out the residents' attitudes for the components of home environment. This study proceeded with purposes 1) to define the components which are used to evaluate home environment and 2) to suggest the profile of home environment by analyzing the rate of significance and consideration for them. A survey was conducted by 511 housewives who live in Pusan, and analyzed by using frequency, percentage, mean, factor analysis, t-test, one-way ANOVA and Scheffe's test. The major findings are as follows: 1) The 16 elements were selected as the components which are used to evaluate home environment. 2) As for residents' attitudes, the profile of the rate of significance and consideration for the components showed generally high as over 3.0(mean) in all elements. 3) A comfortable environments, safety, housing atmosphere, traffic environments and educational environments were found out as elements that were very significantly recognized and considered in the profile. 4) As for residents' attitudes according to housing and household characteristics, there was a difference in a few elements.

  • PDF

Salience of Envelope Interaural Time Difference of High Frequency as Spatial Feature (공간감 인자로서의 고주파 대역 포락선 양이 시간차의 유효성)

  • Seo, Jeong-Hun;Chon, Sang-Bae;Sung, Koeng-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.381-387
    • /
    • 2010
  • Both timbral features and spatial features are important in the assessment of multichannel audio coding systems. The prediction model, extending the ITU-R Rec. BS. 1387-1 to multichannel audio coding systems, with the use of spatial features such as ITDDist (Interaural Time Difference Distortion), ILDDist (Interaural Level Difference Distortion), and IACCDist (InterAural Cross-correlation Coefficient Distortion) was proposed by Choi et al. In that model, ITDDistswere only computed for low frequency bands (below 1500Hz), and ILDDists were computed only for high frequency bands (over 2500Hz) according to classical duplex theory. However, in the high frequency range, information in temporal envelope is also important in spatial perception, especially in sound localization. A new model to compute the ITD distortions of temporal envelopes in high frequency components is introduced in this paper to investigate the role of such ITD on spatial perception quantitatively. The computed ITD distortions of temporal envelopes in high frequency components were highly correlated with perceived sound quality of multichannel audio sounds.

Design of A High Energy Density Pulse Transformer (고 에너지 밀도 펄스 변압기 설계)

  • Nam, S.H.;Park, S.S.;Ha, K.M.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2186-2188
    • /
    • 1999
  • A high frequency and energy density pulse transformer is a critical component of a high voltage power supply in a traveling wave tube (TWT) amplifier system. In this paper, processes of design, manufacturing, and test of the transformer are discussed. Primary voltage of the transformer is 240 V. The transformer secondary have two outputs which are 4100 V (Helix) and 2050 V (Collector). Total output power is 860 W. Normal operating frequency of the transformer is 10 kHz. In high energy density pulse transformers, temperature rise is a main problem during its operation. From our study, it was found that resonant current due to leakage inductance and stray capacitance was the main cause of temperature rise. This happens because of the inherently high turn-ratio in high voltage transformers. Solutions to reduce stray components are presented.

  • PDF

Analysis of acoustic emission signals during fatigue testing of a M36 bolt using the Hilbert-Huang spectrum

  • Leaman, Felix;Herz, Aljoscha;Brinnel, Victoria;Baltes, Ralph;Clausen, Elisabeth
    • Structural Monitoring and Maintenance
    • /
    • v.7 no.1
    • /
    • pp.13-25
    • /
    • 2020
  • One of the most important aspects in structural health monitoring is the detection of fatigue damage. Structural components such as heavy-duty bolts work under high dynamic loads, and thus are prone to accumulate fatigue damage and cracks may originate. Those heavy-duty bolts are used, for example, in wind power generation and mining equipment. Therefore, the investigation of new and more effective monitoring technologies attracts a great interest. In this study the acoustic emission (AE) technology was employed to detect incipient damage during fatigue testing of a M36 bolt. Initial results showed that the AE signals have a high level of background noise due to how the load is applied by the fatigue testing machine. Thus, an advanced signal processing method in the time-frequency domain, the Hilbert-Huang Spectrum (HHS), was applied to reveal AE components buried in background noise in form of high-frequency peaks that can be associated with damage progression. Accordingly, the main contribution of the present study is providing insights regarding the detection of incipient damage during fatigue testing using AE signals and providing recommendations for further research.

Numerical Study on Frequency Up-conversion in USPR using MATLAB

  • Roh, Young-Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.497-502
    • /
    • 2010
  • In this paper, the O-mode ultrashort-pulse reflectometry (USPR) millimeter-wave signals that propagate into the plasma and cover a frequency bandwidth of 33-158 GHz are examined numerically using MATLAB. Two important processes are involved in the computation: the propagation of the USPR impulse signal through a waveguide and the frequency up-conversion using millimeter-wave mixers. These mixers are limited to intermediate frequency signals that are less than 500 mV; thus, it is necessary to disperse the impulse signal into a chirped waveform using the waveguide. The stationary phase method is utilized to derive a closed-form formula for a chirped waveform under the assumption that the USPR impulse is Gaussian. In the process of frequency up-conversion, the chirped waveform is mixed with the mixer LO signal, and the lower frequency components of the RF signal are removed using high pass filters.

A Study on the Ignition Hazard of Flammable Mixtures by Radio-Frequency Spark (고주파 스파크에 의한 가연성 혼합가스의 점화위험성에 관한 연구)

  • Choi, Sang-Won;Lee, Gwan-Hyung;Moon, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1913-1916
    • /
    • 1996
  • With a progress of electrical and electronic technology, radio-frequency circuits including high frequency components are widely applied to various industrial installations. Some of them are used in hazardous locations where explosive or flammable gases exist. As a result, ignition of such gases may be induced by a spark discharge when the radio frequency circuits are switched on or off. The purpose of this study is to investigate the ignition hazards of acetylene-air and ethylen-air mixtures experimentally based on the IEC 79-3 publication. In this experiment, we used a high frequency resistive circuit which consists of a co-axial cable, a $10{\Omega}$, $20{\Omega}$, $30{\Omega}$, $40{\Omega}$ or $50{\Omega}$ resistor and a power amplifier with frequency range up to almost 1 MHz. Experimental results show that the ignition of the acetylene-air and ethylen-air mixtures due to spark discharge depends primarily on the frequency of the power source in the resistive circuit: the minimum ignition voltage increases gradually with the increase of the frequency.

  • PDF

A Study on Battery Chargers for the next generation high speed train using the Phase-shift Full-bridge DC/DC Converter (위상전이 풀-브리지 DC/DC 컨버터를 이용한 차세대 고속 전철용 Battery Charger에 관한 연구)

  • Cho, Han-Jin;Lee, Won-Cheol;Lee, Sang-Seok;Kim, Tae-Hwan;Won, Chung-Yuen
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.623-628
    • /
    • 2009
  • There is an increasing demand for efficient high power/weight auxiliary power supplies for use on high speed traction application. Many new conversion techniques have been proposed to reduce the voltage and current stress of switching components, and the switching losses in the traditional pulse width modulation(PWM) converter. Especially, the phase shift full bridge zero voltage switching PWM techniques are thought most desirable for many applications because this topology permits all switching devices to operate under zero voltage switching(ZVS) by using circuit parasitic components such as leakage inductance of high frequency transformer and power device junction capacitance. The proposed topology is found to have higher efficiency than conventional soft-switching converter. Also it is easily applicable to phase shift full bridge converter by applying an energy recovery snubber consisted of fast recovery diodes and capacitors.

  • PDF

A Study on the Battery Charger for Next Generation High Speed Train (차세대 고속 전철용 Battery Charger 에 관한 연구)

  • Jeong, Han-Jeong;Lee, Won-Cheol;Lee, Sang-Seok;Paik, Jin-Sung;Won, Chung-Yuen
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.321-324
    • /
    • 2008
  • Recently, there is an increasing demand for efficient high power/weight auxiliary power supplies for use on high speed traction application. many new conversion techniques have been proposed to reduce the voltage and current stress of switching components, and the switching losses in the traditional pulse width modulation(PWM) converter. Among them, the phase shift full bridge zero voltage switching PWM techniques are thought most desirable for many applications because this topology permits all switching devices to operate under zero voltage switching(ZVS) by using circuit parasitic components such as leakage inductance of high frequency transformer and power device junction capacitance. The proposed topology is found to have higher efficiency than conventional soft-switching converter. Also it is easily applicable to phase shift full bridge converter by applying an energy recovery snubber consisted of fast recovery diodes and capacitors.

  • PDF

A Novel Fast Open-loop Phase Locking Scheme Based on Synchronous Reference Frame for Three-phase Non-ideal Power Grids

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1513-1525
    • /
    • 2016
  • Rapid and accurate phase synchronization is critical for the reliable control of grid-tied inverters. However, the commonly used software phase-locked loop methods do not always satisfy the need for high-speed and accurate phase synchronization under severe grid imbalance conditions. To address this problem, this study develops a novel open-loop phase locking scheme based on a synchronous reference frame. The proposed scheme is characterized by remarkable response speed, high accuracy, and easy implementation. It comprises three functional cascaded blocks: fast orthogonal signal generation block, fast fundamental-frequency positive sequence component construction block, and fast phase calculation block. The developed virtual orthogonal signal generation method in the first block, which is characterized by noise immunity and high accuracy, can effectively avoid approximation errors and noise amplification in a wide range of sampling frequencies. In the second block, which is the foundation for achieving fast phase synchronization within 3 ms, the fundamental-frequency positive sequence components of unsymmetrical grid voltages can be achieved with the developed orthogonal signal construction strategy and the symmetrical component method. The real-time grid phase can be consequently obtained in the third block, which is free from self-tuning closed-loop control and thus improves the dynamic performance of the proposed scheme. The proposed scheme is adaptive to severe unsymmetrical grid voltages with sudden changes in magnitude, phase, and/or frequency. Moreover, this scheme is able to eliminate phase errors induced by harmonics and random noise. The validity and utility of the proposed scheme are verified by the experimental results.