• Title/Summary/Keyword: high-frequency components

Search Result 989, Processing Time 0.03 seconds

A Study on the Barriers of Researcher's Access to Information (경보접근 장애요소의 심각도와 심각도 구성요인 간의 관계)

  • Lee Eun Chul
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.23
    • /
    • pp.165-205
    • /
    • 1992
  • The purpose of this research is to verify the hypothesis that the serious ness of barriers may have significant relevance to barrier components expressing the extent of barrier, e. g. their frequency of occurrence, effect of the barrier on the acquisition of information and on the research project and trend of the barrier. Major conclusions made in this research are summarized as follows: 1. Barriers that their frequency of occurrence are high, show high seriousness of barriers. This indicates that frequency of barriers affects the seriousness of barriers. 2. Barriers that their effects on the acquisition of information and on the research project are large, show high seriousness of barriers. This indicates that the effect of the barrier on the acquisition of information and on the research project affects the seriousness of barriers. 3. Barriers that their trends are increasing, show high seriousness of barriers. This indicates that the trend of the barrier affects the seriousness of barriers.

  • PDF

Earthquake Response Characteristics of a Port Structure According to Exciting Frequency Components of Earthquakes (가진 주파수성분에 따른 항만구조물의 지진응답특성에 관한 연구)

  • Kim Doo Kie;Ryu Hee Ryong;Seo Hyeong Yeol;Chang Seong Kyu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.1
    • /
    • pp.41-46
    • /
    • 2005
  • The seismic response characteristics of a port structure were investigated by the earthquake analyses of the structure subjected to high-, low-frequency component, and Uljin earthquakes. In the Fluid-Structure-Soil Interaction(FSSI) analysis, the fluid is modeled by the 4-node quadrilateral element which is a modification of a structural plane element, and the port structure and foundation is modelled by the plane strain element. Since the present method directly models the fluid-structure-soil interaction system using finite element method, it can be easily applied to the dynamic analysis of a 2-D fluid-port-soil system with complex geometry. The results of the seismic coefficient. added mass, and FSSI methods are compared. The results showed that the earthquake with high frequency components more affects the seismic response of the structure than that of low frequency components.

A Study on Detection of Significant point in ECG using Neural Network (신경회로망을 이용한 ECG 특성점 검출에 관한 연구)

  • Sohn, Sang-Yoon;Jeong, Kee-Sam;Chung, Sung-Jin;Lee, Myung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.109-112
    • /
    • 1995
  • This paper is a study on the detection of the significant point in ECG signal. ECG signal consists of two components; one is high frequency component to be detected and the other is low frequency component to be removed. AR model is appropriate for modelling and removing the low frequency component. AR model coefficients are updated by artificial neural network algorithm. We can remove the background noise(low frequency) by passing through the AR filter. The remaining signals which include high frequency noise are sent to the matched filter to pass only the signal which we want to extract. The template used in matched filter is updated adaptively.

  • PDF

AWGN Removal Algorithm Considering High Frequency Components (고주파 성분을 고려한 AWGN 제거 알고리즘)

  • Cheon, Bong-Won;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.481-483
    • /
    • 2018
  • Recently, as the demand for electronic communication equipment increases, the importance of image and signal processing is increasing. However, noise is generated in digital signal due to various causes during transmission and reception, lowering equipment reliability and causing malfunction. Particularly, since AWGN may be found in most electronic equipments, AWGN removal is mandatorily performed as a preprocessing phase in various fields, such as image recognition, extraction, and segmentation. In the present paper, an AWGN removal algorithm which considers high frequency components is proposed. Conventional methods show relatively inadequate performance in images with high frequency components. To overcome this problem, proposed is a filter algorithm that add or subtract difference images in the local mask. And to verify performance of the proposed algorithm, PSNR and enlarged images are used to compare with the existing methods.

  • PDF

A Test Study on Interface Dynamics of Current Collection System in High Speed Trains

  • Kim, Jung-Soo;Han, Jae-Hyun
    • International Journal of Railway
    • /
    • v.4 no.2
    • /
    • pp.34-41
    • /
    • 2011
  • Using a test run data, the dynamics of the interface between the catenary and pantograph constituting the current collection system in high-speed trains are investigated. The test run signals are analyzed to determine the dynamic parameters critical to the current collection performance. There are found to be frequency components of the pantograph motion that are dependent on train speed as well as components that are stationary such as the resonant mode of the panhead suspension in the pantograph. From contact force measurement using load cell, the mean contact force was found to be stable while the fluctuating component was found to be dependent on the range of the frequency of the pantograph motion taken into account. The finding implies that numerical investigations reported in the literature that are based on lumped element models of the catenary and/or pantograph provide accurate predictions on the mean value but are of limited use in estimating fluctuation of the contact force. It is concluded that simulation studies based on lumped-element models which do not incorporate panhead structural vibration modes is inaccurate at high train speeds.

Selective Extraction of a Single Optical Frequency Component from an Optical Frequency Comb (광 주파수 빗으로부터 단일 광 주파수 성분의 선택적 추출)

  • Han Seb Moon
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.6
    • /
    • pp.225-234
    • /
    • 2023
  • Mode-locked pulse lasers have a temporal periodicity up over a short period of time. However, in the time-frequency domain, a pulsed laser with temporal periodicity is described as an optical frequency comb with constant frequency spacing. Each frequency component of the optical frequency comb in the frequency domain is then a continuous-wave (CW) laser with hundreds of thousands of single-frequency-component CW lasers in the time domain. This optical frequency comb was developed approximately 20 years ago, enabling the development of the world's most precise atomic clocks and precise transmission of highly stable optical frequency references. In this review, research on the selective extraction of the single-frequency components of optical frequency combs and the control of the frequency components of optical combs is introduced. By presenting the concepts and principles of these optical frequency combs in a tutorial format, we hope to help readers understand the properties of light in the time-frequency domain and develop various applications using optical frequency combs.

Pulse Width and Pulse Frequency Modulated Soft Commutation Inverter Type AC-DC Power Converter with Lowered Utility 200V AC Grid Side Harmonic Current Components

  • Matsushige T.;Ishitobi M.;Nakaoka M.;Bessyo D.;Yamashita H.;Omori H.;Terai H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.484-488
    • /
    • 2001
  • The grid voltage of commercial utility power source hi Japan and USA is 100rms, but in China and European countries, it is 200rms. In recent years, In Japan 200Vrms out putted single phase three wire system begins to be used for high power applications. In 100Vrms utility AC power applications and systems, an active voltage clamped quasi-resonant Inverter circuit topology using IGBTs has been effectively used so far for the consumer microwave oven. In this paper, presented is a half bridge type voltage-clamped high-frequency Inverter type AC-DC converter using which is designed for consumer magnetron drive used as the consumer microwave oven in 200V utility AC power system. This zero voltage soft switching Inverter can use the same power rated switching semiconductor devices and three-winding high frequency transformer as those of the active voltage clamped quasi-resonant Inverter using the IGBTs that has already been used for 100V utility AC power source. The operating performances of the voltage source single ended push pull type Inverter are evaluated and discussed for consumer microwave oven. The harmonic line current components In the utility AC power side of the AC-DC power converter operating at ZVS­PWM strategy reduced and improved on the basis of sine wave like pulse frequency modulation and sine wave like pulse width modulation for the utility AC voltage source.

  • PDF

Development of a High-Resolution Electrocardiography for the Detection of Late Potentials (Late Potential의 검출을 위한 고해상도 심전계의 개발)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.449-458
    • /
    • 1996
  • Most of the conventional electrocardiowaphs foil to detect signals other than P-QRS-T due to the limited SNR and bandwidth. High-resolution electrocardiography(HRECG) provides better SNR and wider bandwidth for the detection of micro-potentials with higher frequency components such as vontricular late potentials(LP). We have developed a HRECG using uncorrected XYZ lead for the detection of LPs. The overall gain of the amplifier is 4000 and the bandwidth is 0.5-300Hz without using 60Hz notch filter. Three 16-bit A/D converters sample X, Y, and Z signals simultaneously with a sampling frequency of 2000Hz. Sampled data are transmitted to a PC via a DMA-controlled, optically-coupled serial communication channel. In order to further reduce the noise, we implemented a signal averaging algorithm that averaged many instances of aligned beats. The beat alignment was carried out through the use of a template matching technique that finds a location maximizing cross-correlation with a given beat tem- plate. Beat alignment error was reduced to $\pm$0.25ms. FIR high-pass filter with cut-off frequency of 40Hz was applied to remove the low frequency components of the averaged X, Y, and Z signals. QRS onset and end point were determined from the vector magnitude of the sigrlaIL and some parameters needed to detect the existence of LP were estimated. The entire system was designed for the easy application of the future research topics including the optimal lead system, filter design, new parameter extraction, etc. In the developed HRECG, without signal averaging, the noise level was less than 5$\mu$V$_rms RTI$. With signal averaging of at least 100 beats, the noise level was reduced to 0.5$\mu$V$_rms RTI$, which is low enough to detect LPs. The developed HRECG will provide a new advanced functionality to interpretive ECG analyzers.

  • PDF

Blocky artifacts reduction by step-function modeling in DCT coded images (DCT 부호화된 영상에서 계단함수모형에 의한 구획잡음의 제거방법)

  • Yang, Jeong-Hun;Choi, Hyuk;Kim, Tae-Jeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.7
    • /
    • pp.1860-1868
    • /
    • 1998
  • A simple postprocessing algorithm is proposed to reduce the blocky artifacts of Block Discrete Cosine Transform (BDCT) coded images. Since the block noise is mostly antisymmetric relative to the block boundaries, we model the blocky noise as one-dimensional antisymmertric functions made by superposing DCT basis functions. observing the frequency characteristics of the noies model, we approximate its high frequency components as those of step functions. Then the proposed postprocessing algorithm eliminates the carefully selected high frequency components of step functions in the one-dimensional sN-point DCT domain, when the encoding block size is $N\;{\times}\;N$. It is shown that the proposed algorithm can also be performed in the spatial domain without computational burden of transforms. The experimental results show that the proposed algorithm well reduces the blocky artifacts in both subjective and objectie viewpoints.

  • PDF

Thermal Analysis of a High Speed Induction Motor Considering Harmonic Loss Distribution

  • Duong, Minh-Trung;Chun, Yon-Do;Park, Byoung-Gun;Kim, Dong-Jun;Choi, Jae-Hak;Han, Pil-Wan
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1503-1510
    • /
    • 2017
  • In this paper, a thermal analysis of a high speed induction motor with a PWM voltage source was performed by considering harmonic loss components. The electromagnetic analysis of the high speed induction motor was conducted using the time-varying finite element method, and its thermal characteristics were carried out using the lump-circuit method. Harmonic losses from tests in the high frequency region were divided into core loss and conductor loss components using various ratios, in order to determine the loss distributions for the thermal analysis. The results from both the calculations and experiment were validated using a high speed induction motor prototype operating at 20,000rpm.