• Title/Summary/Keyword: high-dose therapy

Search Result 635, Processing Time 0.022 seconds

High Dose Therapy of Radioactive Iodine for Thyroid Ablation in Thyroid Carcinoma (갑상선 악성종양에서 갑상선 전절제술 후 방사성 요오드 치료의 효과)

  • Ahn Hee-Cheol;Kang Seong-Joon;Hong In-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.1
    • /
    • pp.61-69
    • /
    • 1998
  • Objectives: The response rate of the radioactive iodine(RI) therapy with low dose was variable. Only a few studies reported the response and complication rate with high dose. The goal of this study was to access the ablation and complication rate after high dose of RI therapy (more than 100mCi) and to evaluate the factors affect the results. Material and Methods: During a period of 12 years, 225 patients received high dose of RI from 100 to 200mCi depending on the RI uptake in the whole body after total thyroidectomy. 100mCi of RI was given to 123 patients for ablation who showed the uptake only in the thyroid bed. 150mCi was given to another 84 patients for ablation who had uptake confined to the neck. The other 21 patients took more than 200mCi of RI because the whole body scan showed distant metastasis. Among these patients, the ablation and the complication rate was investigated. Results: Elevated level of the serum thyroglobulin(Tg) decreased less than 5ng/ml after RI therapy in all patients except two in the first group. The second group showed reduction of the serum Tg in 93%. Eighteen of the 21 patients in the third group are still alive after RI therapy. There were no fatal complications after high dose RI therapy and most of the complications were minimal and transient. The complication rate was not related with the dose of RI, age, sex, DNA flowcytometry, serum thyroglobulin level and the extent of node dissection. Conclusion: We concluded that RI therapy with high dose was very effective for thyroid ablation after operation and it also showed excellent results with minimal complications for treatment of metastatic lesions.

  • PDF

Feasibility Test of Flat-Type Faraday Cup for Ultrahigh-Dose-Rate Transmission Proton Beam Therapy

  • Sang-il Pak;Sungkoo Cho;Seohyeon An;Seonghoon Jeong;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.108-113
    • /
    • 2022
  • Purpose: Proton therapy has been used for optimal cancer treatment by adapting its Bragg-peak characteristics. Recently, a tissue-sparing effect was introduced in ultrahigh-dose-rate (FLASH) radiation; the high-energy transmission proton beam is considered in proton FLASH therapy. In measuring high-energy/ultrahigh-dose-rate proton beam, Faraday Cup is considered as a dose-rate-independent measurement device, which has been widely studied. In this paper, the feasibility of the simply designed Faraday Cup (Poor Man's Faraday Cup, PMFC) for transmission proton FLASH therapy is investigated. Methods: In general, Faraday cups were used in the measurement of charged particles. The simply designed Faraday Cup and Advanced Markus ion chamber were used for high-energy proton beam measurement in this study. Results: The PMFC shows an acceptable performance, including accuracy in general dosimetric tests. The PMFC has a linear response to the dose and dose rate. The proton fluence was decreased with the increase of depth until the depth was near the proton beam range. Regarding secondary particles backscatter from PMFC, the effect was negligible. Conclusions: In this study, we performed an experiment to investigate the feasibility of PMFC for measuring high-energy proton beams. The PMFC can be used as a beam stopper and secondary monitoring system for transmission proton beam FLASH therapy.

A Study for Establishment of High Dose Radioiodine Therapy Patients' Release Standard

  • Park, Hoon-Hee;Kim, Hyun-Soo;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.153-156
    • /
    • 2011
  • This study, which is proceeded in the department of nuclear medicine, aims at preventing unnecessary radiation exposure to the patients and the people near the patients by understanding and presenting the realities about the isolating period for the high dose radioiodine patients after total thyroidectomy in the 7 general hospitals in metropolitan area. Theoretically, the physical half-life of the high dose radioiodine is 8 days. Radioiodine lower than 100 mCi usually is eliminated all in 2 days 1 night considering the biological half-life and the amount of excreting radioiodine The hospitalization standard of the patients treated with high-dose radioiodine therapy has been established according to the fact above. Investigation of the data and questionnaire from the hospital have proven that some hospitals didn't even measure the acceptable dose because of the faith in the vague data. Besides, the some of those inevitably let the readmitting patients exceeding the acceptable dose be in the general ward, not in the isolation ward, because the number of the isolation rooms is relatively smaller than the patients. Thus, we want to contribute that patients understand the realities and the hospitals consider the relevant problem actively so that the problem will be settled by this journal.

  • PDF

Effect of High Dose Insulin/Euglycemia Therapy for Acute Calcium Channel Blocker Intoxication: A Systematic Review (급성 칼슘통로차단제 중독에서 고용량 인슐린/정상혈당치료의 효과: 체계적 고찰)

  • Yang, Jinmo;Ko, Dong Ryul;Kong, Taeyoung;Joo, Young Seon;You, Je Sung;Chung, Sung Phil
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.13 no.2
    • /
    • pp.103-110
    • /
    • 2015
  • Purpose: The purpose of this study is to evaluate the effectiveness and the adverse events of high dose insulin/euglycemia therapy in acute calcium channel blocker (CCB) poisoning. Methods: We developed a systematic search strategy and applied it to 4 electronic reference databases. We searched medical journals as well as the bibliographies of relevant articles. All forms of literature relevant to human use of high dose insulin for acute CCB poisoning were included. The literature search was conducted by two investigators in August, 2015 with publication language restricted to English and Korean. Case reports were divided between CCB overdose alone and multi-drug overdose including CCB. The effect and adverse event of high dose insulin and clinical outcome of each case were analyzed. Results: Among 55 searched studies, 20 studies were included. A prospective study, a retrospective study, a systematic review study, and 17 case reports were identified. Case reports consisted of 11 CCB alone and 12 multidrug overdose cases including CCB. Although most cases described significant clinical improvements, one of them showed no beneficial effect. Several adverse events including hypoglycemia and hypokalemia were reported. No significant sequalae from adverse events was reported. Conclusion: Although there were many case reports demonstrating successful use of high dose insulin for CCB poisoning, the effect cannot be estimated due to a possibility of publication bias. Therefore, high dose insulin/euglycemia therapy might be considered adjunctive therapy in cases of CCB intoxication refractory for standard therapy.

  • PDF

Management of Recurrent Thyroid Carcinoma with Negative Diagnostic Radioiodine Whole-Body Scan (진단적 방사성옥소 전신스캔이 음성인 갑상선 재발암의 진료)

  • Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.117-124
    • /
    • 2001
  • Serum thyroglobulin measurement and I-131 whole-body scintigraphy (WBS) are well-established methods for the detection of recurrence in the follow-up of patients with thyroid carcinoma. However, inconsistent results are observed frequently, and these two methods are not always able to detect recurrence. In some patients, serum thyroglobulin level is elevated but the WBS is negative, because the recurrent tumor is too small and below the sensitivity of the diagnostic scan, or there is a dissociation between thyroglobulin synthesis and the iodine frapping mechanism. In such cases, various nuclear imaging methods including Tl-201 Tc-99m-sestamibi, and F-18-FDG PET can be used besides anatomical imaging methods. Among them, FDG PET localizes recurrent lesions in WBS-negative thyroid carcinoma with high accuracy. Several studies have suggested that empirical high-dose I-131 therapy resulted in a high rate of visualization in post-therapy scans with evidence of subsequent improvement. An important question is when to operate on patients with recurrent tumor. We believe that surgical removal is the best means of treatment for patients with localized persistent tumor, despite the high-dose I-131 therapy. with tumor in thyroid remnant, and with isolated recurrence in the lymph node, lung or bone. In addition, we recommend palliative resection of locally unresectable mass with subsequent treatment with high-dose I-131 therapy. Before I-131 therapy, the evaluation of sodium-iodide symporter expression in thyroid carcinoma can predict iodine uptake. Retinoic acid is known to induce redifferentiation, and to enhance I-131 uptake in thyroid carcinoma. Retinoic acid therapy may represent an alternative approach before high-dose I-131 therapy.

  • PDF

Radiotherapy Technique of High Energy Electron (고에너지 전자선의 방사선 치료 기술)

  • SUH M.W.;PARK J.I.;CHOI H.S.;KIM W.Y.
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 1985
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefore, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed does, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under $3\%$ errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under $5\%$ errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatters; i.e., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

Maximum Value Calculation of High Dose Radioiodine Therapy Room (고용량 방사성옥소 치료 병실의 최대치 산출)

  • Lee, Kyung-Jae;Cho, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • Purpose: According to increment of thyroid cancer recently, patients of high dose radioiodine therapy were accumulated. Taking into consideration the acceptance capability in the current facility, this study is to calculate the maximum value of high dose radioiodine therapy in patients for treatment. Materials and Methods: The amount and radioactivity of waste water discharged from high dose radioiodine therapy in patients admitted at present hospital as well as the radiation density of the air released into the atmosphere from the high dose radioiodine therapy ward were measured. When the calculated waste water's radiation and its density in the released air satisfies the standard (management standard for discharge into water supply 30 Bq/L, management standard for release into air 3 $Bq/m^3$) set by the Ministry of Education, Science and Technology, the maximum value of treatable high dose radioiodine therapy in patients was calculated. Results: When we calculated in a conservative view, the average density of radiation of waste water discharged from treating high dose radioiodine therapy one patient was 8 MBq/L and after 117 days of diminution in the water-purifier tank, it was 29.5 Bq/L. Also, the average density of radiation of waste water discharged from treating high dose radioiodine therapy two patients was 16 MBq/L and after 70 days of diminution in the water-purifier tank, it was 29.7 Bq/L. Under the same conditions, the density of radiation released into air through RI Ventilation Filter from the radioiodine therapy ward was 0.38 $Bq/m^3$. Conclusion: The maximum value of high dose radioiodine therapy in patients that can be treated within the acceptance capability was calculated and applied to the current facility, and if double rooms are managed by improving the ward structure, it would be possible to reduce the accumulated treatment waiting period for radioiodine therapy in patients.

  • PDF

Are Medical Personnel Safe from Radiation Exposure from Patient Receiving Radioiodine Ablation Therapy? (갑상선 암의 방사성요오드 치료 시 의료진은 방사선 피폭으로부터 안전한가?)

  • Kim, Chang-Guhn;Kim, Dae-Weung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.259-279
    • /
    • 2009
  • Radioiodine ablation therapy has been considered to be a standard treatment for patient with differentiated thyroid cancer after total thyroidectomy. Patients may need to be hospitalized to reduce radiation exposure of other people and relatives from radioactive patients receiving radioiodine therapy. Medical staffs, nursing staffs and technologists sometimes hesitate to contact patients in radioiodine therapy ward. The purpose of this paper is to introduce radiation dosimetry, estimate radiation dose from patients and emphasize the safety of radiation exposure from patients treated with high dose radioiodine in therapy ward. The major component of radiation dose from patient is external exposure. However external radiation dose from these patients treated with typical therapeutic dose of 4 to 8 GBq have a very low risk of cancer induction compared with other various risks occurring in daily life. The typical annual radiation dose without shielding received by patient is estimated to be 5 to 10 mSv, which is comparable with 100 to 200 times effective dose received by chest PA examination. Therefore, when we should keep in mind the general principle of radiation protection, the risks of radiation exposure from patients are low and the medical personnel are considered to be safe from radiation exposure.

Comparison Study of Dose Rate and Physical Parameters in Low and High Dose Rate Intracavitary Radiation Systems for Carcinoma of the Uterne Cervix. (자궁경부암 강내 방사선조사에 있어서 고 및 저 선량율방법에 의한 선량율 비교 고찰)

  • Yang, Chil-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.70-78
    • /
    • 1985
  • The intrauterine irradiation is essential to achieve adequate tumor dose to centeral tumor mass in radio therapy for uterine malignancy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The comparison study of currently using 2 systems was undertaken. The simulation films and medical records of 135 patients who was treated with intrauterine irradiation at one of general hospitals in Busan and Seoul between Jan. 1983 and June 1983, were critically analized and physical parameters of low dose rate system and remote controlled high dose rate system were measured. The physical parameters include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids, the radiation dose ratio to rectum and bladder to reference point A. Followings were summary of study results: 1. In distances between lateral walls of vaginal fornices the low dose rate system showed wide distribution and relatively larger distances. In low dose rate system 5.0-5.9 cm was $55.89\%$ 6.0-6.9 cm: $23.53\%$, 4.0-4.9cm: $10.29\%$, 3.0-3.9cm: $10.29\%$, and in high dose rate system 5.0-5.9cm was $80.59\%$, 4.0-4.9cm: $17.91\%$, $6.0\~6.9\;cm:\;1.5\%$. 2. In lateral angulation of tandem to body axis, the low does system revealed mid position (the position along body axis) $64.7\%$, Lt. deviation $19.13\%$ and Rt. deviation $16.17\%$. However the high dose rate system revealed mid position $49.26\%$ Lt. deviation $40.29\%$ and Rt. deviation $10.45\%$. 3. In longitudinal angulation of tandem to body axis the mid position was $11.77\%$ and anterior angulation $88.23\%$ in low dose rate system but in high dose rate system the mid position was $1.56\%$ and anterior angulation $98.44\%$. 4. Down ward displacement of ovoids below external os was only $2.94\%$ in low dose rate system and $67.69\%$ in high dose rate system. 5. The radiation dose ration to rectum to reference point A was $102.70\%$ in high dose rate system and $70.09\%$ in low dose rate system. The dose ratio to bladder to reference point A was $78.14\%$ in high dose rate system and $75.32\%$ in low dose rate system.

  • PDF

Literature Review of Clinical Usefulness of Heavy Ion Particle as an New Advanced Cancer Therapy (첨단 암 치료로서 중입자치료의 임상적 유용성에 대한 고찰)

  • Choi, Sang Gyu
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.413-422
    • /
    • 2019
  • Heavy ion particle, represented carbon ion, radiotherapy is currently most advanced radiation therapy technique. Conventional radiation therapy has made remarkable changes over a relatively short period of time and leading various developments such as intensity modulated radiation therapy, 4D radiation therapy, image guided radiation therapy, and high precisional therapy. However, the biological and physical superiority of particle radiation, represented by Bragg peak, can give the maximum dose to tumor and minimal dose to surrounding normal tissues in the treatment of cancers in various areas surrounded by radiation-sensitive normal tissues. However, despite these advantages, there are some limitations and factors to consider. First, there is not enough evidence, such as large-scale randomized, prospective phase III trials, for the clinical application. Secondly, additional studies are needed to establish a very limited number of treatment facilities, uncertainty about the demand for heavy particle treatment, parallel with convetional radiotherapy or indications. In addition, Bragg peak of the heavy particles can greatly reduce the dose to the normal tissues front and behind the tumor compared to the photon or protons. High precision and accuracy are needed for treatment planning and treatment, especially for lungs or livers with large respiratory movements. Currently, the introduction of the heavy particle therapy device is in progress, and therefore, it is expected that more research will be active.