• 제목/요약/키워드: high voltage generator

검색결과 573건 처리시간 0.034초

승압헝 컨버터의 직렬 배열에 의한 펄스전압 발생회로 (Pulse generator using series-connected boost converter)

  • 백주원;유동욱;변영복;김태진;조기연;김홍근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1106-1109
    • /
    • 2002
  • This paper introduces an improved pulse generator using power semiconductors. The proposed circuit consists of the series connected boost converter structure. In the presented circuits, high voltage pulse is generated by series-connection of capacitors and IGBTs. The charging of capacitors and voltage balance of IGBTs is done automatically. To verify the proposed circuit, 1kV, 25A pulse generator is manufactured and tested.

  • PDF

0.25/100 ${\mu}s$ 후속 단시간 뇌격전류 발생기 회로 기술 (Study on Generator Design for Subsequent Negative Stroke of 0.25/100 ${\mu}s$)

  • 이태형;조성철;엄주홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1632-1633
    • /
    • 2011
  • In IEC 62305-1 standard, the simple circuit consisting of RLC is used in order to form the fast rise time of 0.25/100 ${\mu}s$. But this circuit is very expensive system because the system is needed very high charging voltage up to 3.5 MV. In this paper, we suggest the generator which generates the current up to 10 kA by using the low charging voltage of the dozen kV. Therefore the generator was installed then we compared measure results with calculated results.

  • PDF

순시 자속을 이용한 SRG의 센서리스 제어 및 출력전압제어 (Sensorless and output voltage control of Switched Reluctance Generator using Instantaneous flux)

  • 오승보;김영석;최양광;김영조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.19-22
    • /
    • 2001
  • A Switched Reluctance Generator attracts much attention in the generator because of high efficiency, simplicity, and ruggedness. However, they require rotor position information to operate. In many systems, the rotor position sensor is expensive, limited and undesirable. This paper describes a new approach to estimating the rotor position of the SRG from the measured terminal voltage and current for rotor position sensorless control. The proposed method is based on the instantaneous flux of the SRG. The proposed technique is very simple. The proposed method is verified by computer simulation and experiments.

  • PDF

AC and DC Applications of Induction Generator Excited by Static VAR Compensator

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권3호
    • /
    • pp.169-179
    • /
    • 2004
  • This paper presents the steady-state analysis of the three-phase self-excited induction generator (SEIG). The three-phase SEIG with a squirrel cage rotor is driven by a variable-speed prime mover (VSPM) or a constant-speed prime mover (CSPM) such as a wind turbine or a micro gas turbine. Furthermore, a PI closed-loop feedback voltage regulation scheme of the three-phase SEIG driven by a VSPM on the basis of the static VAR compensator (SVC) is designed and evaluated for the stand-alone AC and DC power applications. The simulation and experimental results prove the practical effectiveness of the additional SVC with the PI controller-based feedback loop in terms of its fast responses and high performances

적응 슬라이딩 모드 관측기를 이용한 Switched Reluctance Generator의 위치 센서 없는 구동에 관한 연구 (Adaptive Sliding Mode Observer for DC-Link Voltage Control of Switched Reluctance Generator without Position Sensor)

  • 최양광;김영석;김영조;최정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.179-182
    • /
    • 2002
  • The position information of the rotor are required while the SRG(Switched Reluctance Generator) is drived. The position information is generally provided by shaft encoder or resolver. But it is weak in the dusty, high temperator and EMI environment. Therefore, the sensor is able to required to eliminated from the SRG. In this paper, a estimation algorithm for the rotor position of the SRG is introducted and a constant DC-link voltage is controled by PID controller. The estimation algorithm is implemened by the adaptive sliding observer and that it is able to estimate the rotor position well is proved by the simulation.

  • PDF

A DVR Control for Compensating Unbalanced Voltage Dips of a DFIG System using Zero Sequence Components

  • Thinh, Quach Ngoc;Ko, Ji-Han;Kim, Dong-Wan;Kim, Eel-Hwan
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.62-68
    • /
    • 2013
  • The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generators based on doubly-fed induction generator (DFIG) that is operated under unbalanced voltage dip conditions. The compensating voltages of the DVR depend on the voltage dips and on the influence of the zero sequence component. The zero sequence component results in high insulation costs and asymmetry in terminal voltages. This paper proposes the use of a proportional-resonant controller in stationary reference frames for controlling zero sequence components in the DVR to protect the DFIG during unbalanced voltage dips. To enhance the proposed control method, a comparison is carried out between two cases: with and without using the control of a zero sequence component. Simulation results are presented to verify the effectiveness of the proposed control method by using the Psim simulation program.

전자레인지용 LLC 공진형 인버터의 디지털 출력 제어 (Digital Power Control of LLC Resonant Inverter for Microwave Oven)

  • 강계룡;김흥근;차헌녕
    • 전력전자학회논문지
    • /
    • 제22권5호
    • /
    • pp.457-462
    • /
    • 2017
  • This paper proposes a digital power control of the LLC resonant half-bridge inverter for high power microwave oven application. Conventional half-bridge inverter for driving a microwave oven uses a hardware-based power control method which varies the frequency according to the AC source voltage. In this case, it is difficult to control the output power according to the variation of the load status of magnetron. The proposed power control consists of an instantaneous current generator and a current controller. Instantaneous current generator makes an instantaneous current reference from power command using input voltage information. Current controller controls input current which has an information of status of magnetron. The proposed power control does not require any compensation algorithm for the change of the load status of the magnetron and change of input voltage. The validity of the proposed method for the control of the change of input voltage and frequency is verified by both simulation and experiment.

SRM의 여자전압제어를 위한 5-레벨 인버터 (5-Level Inverter for Excitation Voltage Control of SRM)

  • 이상훈;박성준;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.294-296
    • /
    • 2000
  • Energy recovery in the regenerative region is very important when SRM(Switched Reluctance Motor) is used in traction drive. This is because that to reduce energy loss during mechanical braking and/or to have a high efficiency drive during braking. To control excitation voltage in motor operation and regenerative voltage in the generator operation in the SRM, multi-level voltage control is effective. This paper suggests multi-level inverter which is useful for motoring and regenerative operation in SRM.

  • PDF

팻 다이폴 안테나를 이용한 광대역 LC 오실레이터에 관한 연구 (A Study on Wideband LC Oscillator Using Fat Dipole Antenna)

  • 이상흔;윤영중;허훈;남상훈;이우상;최도원
    • 한국전자파학회논문지
    • /
    • 제19권11호
    • /
    • pp.1185-1192
    • /
    • 2008
  • 본 논문에서는 고전압 스위치와 팻 다이폴 안테나로 구성되는 광대역 LC 오실레이터를 설계 및 제작하고 방사 특성에 관해 분석하였다. 제안된 광대역 LC 오실레이터는 Marx generator를 고전압 펄스 전원 장치로 사용하며 지향성을 높이기 위해 $90^{\circ}$ 코너 리플렉터를 사용한다. 시뮬레이션 및 측정 파형을 분석한 결과, 팻 다이폴을 연결하지 않은 고전압 스위치는 수신 전력을 기준으로 약 9%(${\lambda}_1=0.7\;m$)의 3 dB 대역폭을 가지며, 고전압 스위치와 팻 다이폴 안테나로 구성되는 LC 오실레이터는 약 30%(${\lambda}_2=1\;m$)의 대역폭을 가진다. 결과적으로 팻 다이폴 안테나가 방사 전력뿐만 아니라 동작 주파수 및 대역폭에 영향을 미치는 것을 확인할 수 있었다. 본 논문의 연구 내용은 고전압 스위치와 팻 다이폴 안테나로 구성되는 광대역 LC 오실레이터 설계 시 동작 주파수와 방사 전력을 결정하는데 있어서 매우 유용할 것으로 판단된다.

Irradiation of Intense Characteristic X-rays from Weakly Ionized Linear Plasma

  • Sato, Eiichi;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Takayama, Kazuyoshi;Ido, Hideaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.396-399
    • /
    • 2002
  • Intense quasi-monochromatic x-ray irradiation from the linear plasma target is described. The plasma x-ray generator employs a high-voltage power supply, a low-impedance coaxial transmission line, a high-voltage condenser with a capacity of about 200 nF, a turbo-molecular pump, a thyristor pulse generator as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 55 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to the molybdenum target by the electric field in the tube, the weakly ionized plasma, which consists of metal ions and electrons, forms by the target evaporating. In the present work, the peak tube voltage was almost equal to the initial charging voltage of the main condenser, and the peak current was about 20 kA with a charging voltage of 55 kV. When the charging voltage was increased, the linear plasma x-ray source grew, and the characteristic x-ray intensities of K-series lines increased. The quite sharp lines such as hard x-ray lasers were clearly observed. The quasi-monochromatic radiography was performed by a new film-less computed radiography system.

  • PDF