An RF Front-end for Terrestrial and Cable Digital TV Tuners (지상파 및 케이블 디지털 TV 튜너를 위한 RF 프런트 엔드)

  • Choi, Chihoon;Im, Donggu;Nam, Ilku
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제49권12호
    • /
    • pp.242-246
    • /
    • 2012
  • This paper presents an integrated low noise and highly linear wideband RF front-end for a digital terrestrial and cable TV tuner, which are used as a part of double-conversion TV tuner. The low noise amplifier (LNA) has a low noise figure and high linearity by adopting a noise canceling technique based on current amplification. The up-conversion mixer and SAW buffer have high linearity by employing a third order intermodulation cancellation technique. The proposed RF front-end is designed in a $0.18{\mu}m$ CMOS and draws 60 mA from a 1.8 V supply voltage. The RF front-end shows a voltage gain of 30 dB, an average single side-band noise figure of 4.2 dB, an IIP2 of 40 dBm, and an IIP3 of -4.5 dBm for the entire band from 48 MHz to 862Hz.

Electrical properties of XLPE and Semiconductor Materials for Power Cable (전력케이블의 가교폴리에틸렌과 반도전 재료의 전기적 특성)

  • Lee, Ju-Hong;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.207-210
    • /
    • 2008
  • In this paper, we researched the dielectric properties and voltage dependence on slice XLPE sheet from 22[kV] and 154[kV] power cable. We studied effects for impurities and water for semiconductor shield through a dielectric properties experiment to estimate performance of insulating materials in power cable. Capacitance and $tan{\delta}$ of 22[kV], 154[kV] were 53/43[pF] and $7.4{\times}10^{-4}$, $2.1510^{-4}$. In these results, the trend was increased with the increase of temperature. The tan6 of XLPE/semiconductor layer was increased as compared with that of XLPE. Dielectric properties reliability of tan6 was small. Also, To improve mean-life and reliability of power cable in this study, we have investigated chemical properties showing by changing the content of carbon black that is semiconductive additives for underground power transmission. Specimens were made of sheet form with the three of existing resins and the nine of specimens for measurement. Chemical properties of specimens was measured by FT-ATR (Fourier Transform Attenuated Total Reflectance). The condition of specimens was a solid sheet. We could observe functional group (C=O, carbonyl group) of specimens through FT-ATR. From these experimental result, the concentration of functional group (C=O) was high according to increasing the content of carbon black. We could know EEA was excellent more than other specimens from above experimental results.

  • PDF

Effect of Laminated Polypropylene Paper on the Breakdown Strength of Multi-layer Insulation for HTS Cable

  • Nguyen, Van-Dung;Baek, Seung-Myeong;Kwag, Dong-Soon;Kim, Sang-Huyn
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.87-93
    • /
    • 2004
  • Laminated Polypropylene Paper (LPP) and Kraft paper were used as ac power insulation for conventional cable as well as high temperature superconducting (HTS) cable because of its prominent insulating characteristics. However, researches on the use of LPP/Kraft paper in HTS cables are thinly scattered. In this paper, the effect of laminate polypropylene paper on the breakdown strength of LPP/Kraft multi-layer sample impregnated with liquid nitrogen (LN2)under ac and impulse applied voltage was studied. In addition, the breakdown strength characteristics of LPP and Kraft multi-layer sample were also investigated. It was found from the experimental data that the LPP has higher breakdown strength value than Kraft paper in ac and impulse. Especially in the ac case, the breakdown strength increases as the component ratio of LPP in the LPP/Kraftsample increases and slightly affected by the inserting position of LPP but in impulse case, the breakdown strength strongly depends on the number of LPP and the relative position of LPP.

  • PDF

The Sugge Voltage restraint of induction motor using low-loss snubber circuit (저손실 스너버 회로를 이용한 유도전동기의 서지전압 억제)

  • Cho, Man-Chul;Mun, Sang-Pil;Kim, Chil-Yong;Kim, Ju-Yong;Shu, Ki-Young;Kwon, Soon-Kurl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.473-477
    • /
    • 2007
  • The development of advanced Insulated Gate Bipolar Transistor(IGBT)has enabled high-frequency switching operation and has improved the performance of PWM inverters for motor drive. However, the high rate of dv/dt of IGBT has adverse effects on motor insulation stress. In many motor drive applications, the inverter and motor are separated and it requires long motor feds. The long cable contributes high frequency ringing at the motor terminal and it results in hight surge voltage which stresses the motor insulation. The inverter output filter and RDC snubber are conventional method which can reduce the surge voltage. In this paper, we propose the new low loss snubber to reduce the motor terminal surge voltage. The snubber consists of the series connection of charging/discharging capacitor and the voltage-clamped capacitor. At IGBT turn-off, the snubber starts to operate when the IGBT voltage reaches the voltage-clamped level. Since dv/dt is decreased by snubber operating, the peak level of the surge voltage can be reduced. Also the snubber operates at the IGBT voltage above the voltage-clamped level, the snubber loss is largely reduced comparing with RDC snubber. The proposed snubber enables to reduce the motor terminal surge voltage with low loss.

  • PDF

Safety Estimation and Analysis Study of the Connector for Lighting Fixture Wiring (조명등기구 배선용 커넥터의 안전성 평가 및 분석에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제58권4호
    • /
    • pp.541-545
    • /
    • 2009
  • This study evaluated the contact resistance, insulation resistance, withstand voltage characteristics and insertion force, etc., of the wire connector used inside an integrated LITE WAY lighting fixture developed for efficient installation. Since the connector connecting the lighting fixture's internal wires is housed, it is easily connected and separated and has a structure enabling a close-fitting connection. The temperature and time applied to the high temperature characteristics test of the connector are $105^{\circ}C$ and 16 hours, respectively. The measured contact resistance of the high temperature tested connector was 3.258 mV/A, and its measured insulation resistance was greater than $10\;G{\Omega}$ All specimens demonstrated uniform insulation characteristics, which could be seen to be in good condition. From the withstand voltage test results found before and after performing the high temperature operation test on the connector for cable connection, it was confirmed that the withstand voltage characteristics between all terminals were good. The insertion force of the connector connecting the internal wiring averaged 9.67 kgf. It was observed that the insertion force between the plug housing and the female terminal, and that between the plug housing and the male terminal, were 0.680 kgf and 1.27 kgf on average, respectively.

The Ballast for HID Lamps of Preventing the Overvoltage with a Long Distance Resonant Ignition (원거리 공진 기동시 과전압 방지 HID 안정기)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제29권1호
    • /
    • pp.94-102
    • /
    • 2015
  • The electronic ballast for HID lamps needs to ignite lamps even though the length from the ballast to lamp is far away. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps because the reduction of ignition voltage is not much depending on the distance. However, the parasitic capacitance is increased depending the length of the cable, and it affects the resonant frequency. The ignitor voltage can be increased drastically under the resonant ignition through frequency sweep, and it is the main reason of blowing up. Therefore, the clamping diode is proposed to suppress the voltage of the primary winding during resonant ignition.

Analysis of Overvoltage Distribution in Low-Voltage Induction Motor Due to Inverter Switching Surge (인버터 스위칭 써지에 의한 저압 유도전동기의 과도전압 분포해석)

  • Hwang, Don-Ha;Kim, Yong-Joo;Lee, In-Woo;Bae, Sung-Woo;Kim, Dong-Hee;Ro, Chae-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1151-1153
    • /
    • 2003
  • In this paper, switching surge voltage distribution in stator windings of induction motor driven by IGBT PWM inverter is studied. To analyze the irregular voltage of stator winding, equivalent circuit model of inverter-cable-motor was proposed and high frequency parameter is computed by using finite element method (FEM). Electromagnetic transient program (EMTP) analysis of the whole system for induction motor and PWM inverter is proposed. In order to experiment, an induction motor, 380 [V], 50 [HP], with taps from one phase and a switching surge generator was built to consider the voltage distribution.

  • PDF

Study on the Prediction of the Life-time in the Macroscopic Solid-Solid Interfaces (고체-고체 거시계면의 수명예측에 관한 연구)

  • 박정규;배덕권;정동회;오재한;김충혁;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.775-778
    • /
    • 2000
  • In this paper, the life-time of macro interface between Epoxy/EPDM which consists in underground power cable joints is predicted. The electrode system of specimen is designed by FEM(finite elements method). The breakdown strength of specimens are observed by applying high AC voltage at the room temperature. The breakdown times under the constant voltage below the breakdown voltage were gained. As constant voltage is applied, the breakdown time is proportion to the breakdown strength. The life exponent n is gained by inverse power law, and the long breakdown life time can be evaluated.

  • PDF

Tracking and erosion resistance of polymer for outdoor high voltage insula (초고압 옥외 절연용 고분자 재료의 트래킹 열화특성)

  • Han, Dong-Hee;Park, Hoy-Yul;Kang, Dong-Pil;Kim, In-Sung
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1578-1580
    • /
    • 1999
  • Silicone rubber is being used for the housing material of outdoor high voltage insulators such as composite insulator, bushing, surge arrestor and cable terminator because of good tracking and erosion resistance, good hydrophobicity and recovery of hydrophobicity, and chemical stability. In this paper, tracking and erosion resistance of silicone rubber having fluids and different ATH contents were examined. Fluids were selected under the consideration of their molecular weight and chemical structure, expecting the high migration rate, the good pollutant encapsulation, and the long period with good hydrophobicity. Good tracking and erosion resistance and arc resistance have been achieved for the silicone rubber above ATH content 130 phr.

  • PDF

A Study on Cable Lifetime Evaluation Based on Characteristic Analysis of Insulation Resistance by Acceleration Factor of the Arrhenius Equation (아레니우스 방정식의 가속인자를 만족하는 절연저항특성 분석에 의한 케이블 수명평가 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • 제14권5호
    • /
    • pp.231-236
    • /
    • 2014
  • With the development of industry these days, the demand for electric power increases and the larger capacity for power transfer is required. The scales of facilities should become larger; and the relative systems are required to operate with a higher degree of reliability. Therefore, stabilization of electric power systems is an important issue. The high degree of reliability required in the process of production and supply of electric power is an essential part of industrial society. Accident such as blackouts causes a hugh amount of economic losses to the high-tech industrial society dependent upon electric power. In this paper, in order to determine a stable operation of high-voltage power cable, used as a unique means of delivering electric power generated at a power station, we figure out the time rate of change of insulation resistance following a decay accelerating factor Arrhenius equation. With the data from the insulation resistance, we can determine the lifetime of power cable in operation.