• Title/Summary/Keyword: high voltage cable

Search Result 339, Processing Time 0.025 seconds

Design and fabrication of the GPS antenna system including RF-stage (RF 수신부를 내장한 GPS 안테나 시스템의 설계 및 제작)

  • 홍성일;이정호;변건식;정만영
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.99-107
    • /
    • 1996
  • When GPS (global positioning system) is used as synchronous signal in CDMA digital cellular base station system and high speed digital synchronous communication network, antenna cable length is increased, comparing with other GPS application such as positioning or car navigation. In this paper, it is proposed that a type of new GPS antenna system including RF stage for reduction of cable loss in case of long cable.The antenna system with TMPA(truncated-corners microstrip patch antenna) is designed and fabricated because GPS signal has RHCP (right-hand circular polarization), consequently antenna size can be made small size. LNA (low noise amplifier) is designed by using HEMT(high electron mobility transistor)which has lower noise figurae and better AGC characteristics at low voltage than GaAs FET, and we equiped mixer, in GPS antenna unit, which converts from 1575.42MHz to 75.42MHz. As result of comparing between typical system and proposed system when cable length is 60m, 63dB, 55dB and 25dB gain are obtained for RG-316/U, RG-58C/U and RG-213/U, and better characteristics are achieved than typical system as far as cable length is longer.

  • PDF

A Case Study on the AC Corrosion Effects of Gas Pipeline by High Voltage Induction in Submarine Tunnel (해저터널내 고전압 유도에 의한 가스배관의 교류전식 영향 사례 연구)

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.346-348
    • /
    • 2001
  • This paper analyze the interference problems, especially AC corrosion when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about AC corrosion, limitation of safety voltage, modeling of power cables, gas pipeline and grounding systems, analysis of induction voltage according to various circumstance, soil resistivity, length of tunnel. and so on.

  • PDF

Electrical Conduction Characteristics of Ultra High Voltage Cable for Prevention of Electrical Fires (전기 방재를 위한 초고압케이블의 전기 전도 특성)

  • Park, Hee-Doo;Park, Ha-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.216-217
    • /
    • 2007
  • In this paper we investigated the volume resistivity and AC conduction current according to the temperature and voltage. As a result, the volume resistivity comes to be small according to the measurement temperature and voltage. AC conduction current of the heat treatment specimen is increased because of the decrease of insulation.

  • PDF

Application Scheme of Resistive HTS-FCL on Future New Distribution System (저항형 초전도한류기의 미래 배전계통 적용방안)

  • Lee Seung-Ryul;Kim Jlong-Yul;Kim Ho-Yong;Yoon Jae-Young
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.5
    • /
    • pp.212-216
    • /
    • 2005
  • This paper describes the application scheme of resistive HTS-FCL(High Temperature Superconducting-Fault Current Limiter) on future new distribution system. Future new distribution system means the power system to which applies the 22.9kV HTS cable with low-voltage and mass-capacity characteristics replacing the 154kv conventional cable in addition to HTS transformer and HTS-FCL. The fault current of future new distribution system will increase greatly because of the inherent characteristics of HTS transformer/cable and applications of distributed generations and spot networks and so on. This means that the HTS-FCL is necessary to reduce the fault current below the breaking capacity. This paper studies the appropriate location, parameters and the influences of HTS-FCL on future new distribution system. Finally, this paper suggests the reasonable basic parameters of resistive HTS-FCL for future KEPCO new distribution system.

HPF Application Test for PD Detection of XLPE Power Cable (XLPE 전력케이블의 부분방전 검출을 위한 HPF 적용 시험)

  • Kim, Jung-Yoon;Yang, Jong-Kyung;Park, Noh-Joon;Choi, Yong-Sung;Park, Dae-Hee;Lee, Yong-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.161-165
    • /
    • 2006
  • In this paper, we developed HPF (high pass filter) consists of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test. We tested it under laboratory circumstances like the fields, and measured the phase change properties of detected signal in UHF sensor with Lemke Probe and oscilloscope (TDS-3054, Tektronix). As a result, we obtained available data showing the decrease of noises in the experiments with the developed HPF from the joint box of 22.9kV distribution line. The result can be adapted to prevent the degeneration of the XLPE power cable, and to observe and diagnosis the underground power transmission cable at the ultra-high voltage.

A study on the PWM power converter with high frequency and high voltage using MOS-GTO (MOS-GTO를 이용한 고주파, 고전압 전력변환기 설계에 관한 연구)

  • Roh, Jin-Eep;Seong, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1009-1011
    • /
    • 1992
  • This paper discribes a study on the bridge type power converter for laser high power generator with high frequency and high voltage using MOS-GTO. This converter effectively makes the best of the high frequency HV transformer and input-side equivalent parasitic capacitance of high voltage feeding cable in place of DC output smoothing filter. The cicuit configuration and performance are discussed and design criteria are given. The prototype rated of 10 KW, 100 KHz is implemented and experimental results are given.

  • PDF

154KV개봉. 오류 지중송전선로 준공보고

  • 김성곤;정수근
    • 전기의세계
    • /
    • v.29 no.11
    • /
    • pp.693-698
    • /
    • 1980
  • We T.E.C. have commenced to develop the O.F. cable in April, 1977. Now we have finished the Type-Test and produced in full-operation of 154KV 1x600mm$^{2}$ and 154KV 1x1200mm$^{2}$ O.F. cables. Especially we have completed pulling and splicing of the 24.82kms O.F. cable in KaeBong-OuRyu Route, and now it is operating well. This has important meaning that Extra High Voltage Under Ground Transmission Line has constructed by domastic engineers for the first time in Korea. Thank to arrange and publish it, and hope it can be helpful to the related.

  • PDF

Asymmetric Capacitive Sensor for On-line and Real-time Partial Discharge Detection in Power Cables

  • Changhee Son;Hyewon Cheon;Hakson Lee;Daekyung Kang;Jonghoo Park
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.219-222
    • /
    • 2023
  • Partial discharges (PD) have long been recognized as a major contributing factor to catastrophic failures in high-power equipment. As the demand for high voltage direct current (HVDC) facilities continues to rise, the significance of on-line and real-time monitoring of PD becomes increasingly prominent. In this study, we have designed, fabricated, and characterized a highly sensitive and cost-effective PD sensor comprising a pair of copper electrodes with different arc lengths. The key advantage of our sensor is its non-invasive nature, as it can be installed at any location along the entire power cable without requiring structural modifications. In contrast, conventional PD sensors are typically limited to installation at cable terminals or insulation joint boxes, often necessitating invasive alterations. Our PD sensor demonstrates exceptional accuracy in estimating PD location, with a success rate exceeding 95% in the straight sections of the power cable and surpassing 89% in curved sections. These remarkable characteristics indicate its high potential for realtime and on-line detection of PD.

Partial Discharge Measurement of Power Cables for Nuclear Power Plant (원자력발전소 전력케이블 부분방전 진단 사례)

  • Ha, Che-Wung;Ju, Kwang-Ho;Lim, Woo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1632-1638
    • /
    • 2011
  • Electric cables are one of the most important components in a nuclear power plant since they provide the power needed to operate electrical equipment. Despite their importance, cables typically receive little attention since they are considered passive, long-lived components that have been very reliable over the years when subjected to the environmental conditions for which they were designed. The operating experience reveals that a defect of the insulator or poor construction causes the initial failure of cable. However, the number of cable failures increase with plant aging, and these cable failures are occurring within the plants' 40-year licensed period. These cable failures have resulted in plant transients, shutdown, loss of safety functions or redundancy, entries into limiting conditions for operation, and challenges for plant operators. Therefore, diagnosis of MV cable installed in NPPs has become one of the most urgent issues in recent years. In accordance with PSR, condition maintenance for cables is also continuously required. Recently, HFPD tests have been widely performed to diagnose cable in the transmission and distribution cable system. However, on-line HFPD wasn't used in the NPPs because of the danger of plant shutdown, measurement sensitivity and application problems, etc. In this paper, HFPD measurement with portable device was performed to evaluate the integrity of the 4.16kV & 13.8kV cable lines. The test results show that HFPD is highly attractive to the diagnosis of MV cables in NPP by high detection sensitivity on-site.

Development of ultra high voltage-large capacity O.F cable (초고압 대용량 O.F 케이블의 개발)

  • Kang, S.H.;Lee, K.J.;Kim, C.S.;Choi, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.265-267
    • /
    • 1991
  • In this paper, we describe the development of 345kv OF cables to contain also the cable employing new insulation paper, PPLP (Poly propylene Laminated paper). The cables all show very excellent properties, especially PPLP cable has less the dielectric loss and better the impulse & A.C strength than the one employing the conventional paper. Therefore, according to use PPLP cable, it seems to be several advantages such as the compact of system, the increasing capacity, and the decreasing energy loss etc.

  • PDF