The Performance Characteristics of Anti-Surge Devices for High Head Cooling Water Systems in 1,000 MW Thermal Power plants (고수두 1,000 MW 석탄화력발전소 냉각수계통 수격방지장치의 성능특성)

  • Kim, Keun-Pil;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.4
    • /
    • pp.36-42
    • /
    • 2019
  • In recent, according to the tightening of environment regulation policy, the height of the site of the power plant is increased and the length of the cooling water pipe is increased. This has a serious impact on the stability of the plant. This study analyzes the transient phenomenon using LIQT 7.2, an unsteady state one-dimensional analysis software, to secure the stability of 1,000 MW high-capacity coal-fired power plant cooling water system with high head. To prevent water hammer, The effects on performance characteristics were predicted by individual and combination application. The surge pressure of the cooling water which occurs when the pump was stopped without installing the anti-surge devices was the largest at the pump outlet side. The most effective and simple way to reduce surge pressure in these cooling water systems is to combine a vacuum breaker with a hydraulic non-return valve, which is an essential device for pump protection.

Fire-fighting Pump Approval Standard for Fire-fighting Trucks with an Additional Positive Displacement Pump (용적형 펌프를 추가한 소방자동차용 소방펌프의 성능 인정기준에 관한 연구)

  • Han, Yong-Taek;Sung, Ki-Chan;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.104-110
    • /
    • 2016
  • Positive displacement pumps with high pressure and water capacity are used large fires in various high-rise buildings. This study provides information for a performance approval standard of fire pumps for fire trucks based on centrifugal pump standards enacted in 2012. An experiment was conducted with a positive displacement pump for three levels of performance from the approval standard (V-1, 2, and 3). The efficiency of the pump was included in the reference, which requires the approval of 65% performance, the same as a centrifugal pump. The water pressure is between 1.5 and 2.5 MPa, and the required flow rate was established as at least $0.31m^3/min$ and up to $3.0m^3/min$. A relief valve was added to adjust the shut-off pressure due to the structural characteristics of the positive displacement pump. A strainer was also installed to prevent damage to the inside of the pump due to foreign matter. However, the strainer includes a difference from the positive displacement pump to operate without a vacuum pump and the centrifugal pump. This is due to the additional approval standard portion of the positive displacement pump, which is expected to be selected for more variety of fire-fighting equipment and proactive responses to fire suppression in a high-rise buildings and large fires. In conclusion, this approval standard was enacted in January 2016.

INTERNAL FLOWS IN AIR PUMP OF ROBOT CLEANER (로봇청소기용 에어 펌프 내부 유동 해석)

  • Kim, J.W.;Seok, I.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.227-231
    • /
    • 2009
  • Traditional vacuum cleaner adoptsa highly rotating centrifugal impeller for generating suction region at lower pressure. The rotational speed is very high at 35,000 to 40,000 rpm and accessory structure such as a circular brush at the base plate of the cleaning devices is equipped for gathering dusts. Highly rotating impeller is effective for low pressure generation but causes noise problems. Recently, the unwanted noise is removed by installation of air-pump, instead of a centrifugal impeller, and the internal flows of the modified system are estimated in numerical and experimental approach, respectively.

  • PDF

Vacuum Characteristic of a Chamber Made of Mild Steel

  • Park, Chongdo;Ha, Taekyun;Cho, Boklae
    • Applied Science and Convergence Technology
    • /
    • v.24 no.4
    • /
    • pp.84-89
    • /
    • 2015
  • The base pressure and outgassing rate of a mild steel chamber were measured and compared to those of a stainless steel chamber. A combined sputter-ion and non-evaporable getter pump with a nominal pumping speed of 490 l/s generated the base pressure of $2.7{\times}10^{-11}$ mbar in the mild steel chamber and $1.2{\times}10^{-10}$ mbar in the stainless steel chamber. The rate-of-rise measurements show that the mild steel has an extremely low outgassing rate of $2.6{\times}10^{-13}$ mbar $ls^{-1}cm^{-2}$, which is about one-order of magnitude smaller than the outgassing rate of the stainless steels. Vacuum annealing of the mild steel at $850^{\circ}C$ reduced the outgassing rate further to $8.8{\times}10^{-14}$ mbar $ls^{-1}cm^{-2}$, which was comparable to the outgassing rate of a heat treated stainless steel for extreme-high vacuum use.

Manufacturing and characterization of ECR-PECVD system (ECR-PECVD 장치의 제작과 특성)

  • 손영호;정우철;정재인;박노길;황도원;김인수;배인호
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2000
  • An ECR-PECVD system with the characteristics of high ionization rat다 ability of plasma processing in a wide pressure range and deposition at low temperature was manufactured and characterized for the deposition of thin films. The system consists of a vacuum chamber, sample stage, vacuum gauge, vacuum pump, gas injection part, vacuum sealing valve, ECR source and a control part. The control of system is carried out by the microprocessor and the ROM program. We have investigated the vacuum characteristics of ECR-PECVD system, and also have diagnosed the characteristics of ECR microwave plasma by using the Langmuir probe. From the data of system and plasma characterization, we could confirmed the stability of pressure in the vacuum chamber according to the variation of gas flow rate and the effect of ion bombardment by the negative DC self bias voltage. The plasma density was increased with the increase of gas flow rate and ECR power. On the other hand, it was decreased with the increase of horizontal radius and distance between ECR source and probe. The calculated plasma densities were in the range of 49.7\times10^{11}\sim3.7\times10^{12}\textrm{cm}^{-3}$. It is also expected that we can estimate the thickness uniformity of film fabricated by the ECR-PECVD system from the distribution of the plasma density.

  • PDF

Construction and Tests of the Vacuum Pumping System for KSTAR Current Feeder System (KSTAR 전류전송계통 진공배기계 구축 및 시운전)

  • Woo, I.S.;Song, N.H.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, Jae-Sik;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.483-488
    • /
    • 2007
  • Current feeder system (CFS) for Korea superconducting tokamak advanced research(KSTAR) project plays a role to interconnect magnet power supply (MPS) and superconducting (SC) magnets through the normal bus-bar at the room temperature(300 K) environment and the SC bus-line at the low temperature (4.5 K) environment. It is divided by two systems, i.e., toroidal field system which operates at 35 kA DC currents and poloidal field system wherein 20$\sim$26 kA pulsed currents are applied during 350 s transient time. Aside from the vacuum system of main cryostat, an independent vacuum system was constructed for the CFS in which a roughing system is consisted by a rotary and a mechanical booster pump and a high vacuum system is developed by four cryo-pumps with one dry pump as a backing pump. A self interlock and its control system, and a supervisory interlock and its control system are also established for the operational reliability as well. The entire CFS was completely tested including the reliability of local/supervisory control/interlock, helium gas leakage, vacuum pressure, and so on.

Development of Ginseng Seeders for the Dual-use in Seedling and Direct Planting (묘삼 직파 겸용 인삼파종기 개발)

  • 이기명;박규식;김창수;김재열;김진현
    • Journal of Biosystems Engineering
    • /
    • v.28 no.5
    • /
    • pp.395-402
    • /
    • 2003
  • Standard ginseng seedling, selected after one year's rearing in the seedling bed has been conventionally transplanted in Korea. Recently, the direct seeding areas have been increasing to product high quality ginsengs for red-ginseng processing. Reciprocating push-rod brush, holed-roller and vacuum suction seeders, planting with 30 ${\times}$ 30mm spacings and adjustable to the folds were designed and theirs performances were evaluated. The developed three types of seeders reliably performed at the success rate over 95% with less than 10% in slip rate, and could be used a seeder for the greater spacings by adjusting metering parts. The research concluded that the vacuum suction seeder was the most feasible and practical with the greatest metering success and the least slip among three type seeders of the reciprocating push-rod brush, holed-roller and vacuum suction seeders. The vacuum suction seeder holds a seed with each needle nozzle using the negative pressure created by a vacuum pump. The capacity was 24.5 times greater than a man power at the speed of 5 m/min.

A Study on the Development of the Automatic Performance­Test­machine for Power Steering Pump (파워스티어링 펌프의 자동 성능 시험기 개발에 관한 연구)

  • 정재연;정석훈
    • Tribology and Lubricants
    • /
    • v.19 no.6
    • /
    • pp.335-341
    • /
    • 2003
  • Recently, the automotive industry is being developed rapidly. On this, a demand of high quality performance­test­machine is increased too. But it is progressive technology that must be combined hydraulic, mechanic and electronic technologies. To construct this system, the design of oil hydraulic circuit, interface skill between sensor and personal computer, data acquisition & display system and integrated control are very important skill. Moreover, reliable data is obtained with vacuum system and complex heat exchange system. Therefore, in this study, we designed a performance­test­machine by using above key technologies and we also made a integrated PC control system using personal computer which is more progressive and flexible method than PLC control.

The Estimating an Effect of Rapid Flux Increase to a Membrane in the Intermittent Aeration MBR Process Using Alum Treatment (응집제를 활용한 간헐포기 MBR공정에서 순간플럭스 증가가 분리막에 미치는 영향 평가)

  • Choi Song-Hyu;Cho Nam-un;Han Myong Su
    • Membrane Journal
    • /
    • v.15 no.1
    • /
    • pp.70-83
    • /
    • 2005
  • By supplying air intermittently in various mode, the effects of oxic/anoxic time ratio and air scrubbing in aeration condition on the membrane flux and permeability were investigated. When suction pump stops, vacuum pressure remains inside the suction pump. Therefore, the effect of remaining vacuum pressure in the suction pump on fouling of membrane was investigated. The effect of EPS (Extra cellular Polymeric Substance) which is generated due to the long SRT and high concentration of MLSS and the dose of coagulant on the membrane were also investigated. The suitable oxic/anoxic time ratio for the best removal efficiency of organic matter and nitrogenous matter was 40 minutes (Oxic) : 20 minutes (Anoxic). At this time ratio, alum was dosed into the aeration tank. The result of dosing alum was that the concentration of alum solution might affect nitrification and denitrification. To remove 1 mg/L of phosphorus in MBR process, it needs 0.75 mg/L of alum solution.

development of High Vacuum pump system (고진공 펌프 시스템 개발에 관한 연구)

  • Kim, Soo-Yong;Lee, Oh-Keol
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.316-318
    • /
    • 2001
  • In this paper, the basic characteristics of flat fluorescent lamp using ultraviolet generated from gas discharge and powder type electrolyminescent display(P-ELD) using a phenomenon of the light emission eaused by the electrical field applied to phosphor are studied. The lamp is a simple structure with insulator layer, phosphor layer, and gas gap. Current(displacement current + discharge current) in flat fluorescent lamp using.