• 제목/요약/키워드: high temperature water

검색결과 4,456건 처리시간 0.035초

고온수중(高溫水中)에 있어서의 스트레인 측정(測定)에 관(關)한 연구(硏究) (Study on the Strain Measurement in Hot Water)

  • 한응교;박광길
    • 비파괴검사학회지
    • /
    • 제1권1호
    • /
    • pp.13-21
    • /
    • 1981
  • When we use the strain gauge in the high temperature water, lowering of insulation resistance between test material and gauge is the matter. The lowering makes the measurement unstable and is the primary factor of an error. This study devises the waterproofing method in empirically that has the best insulating property in the hot water($100^{\circ}C$), In this way, we can reach the conclusion that on the condition of a few hours we can measure precisely in the high temperature like normal temperature.

  • PDF

Corrosion release behavior of alloy 690 and its application in high-temperature water with Zn injection

  • Liao, Jiapeng;Hu, Yousen;Li, Jinggang;Jin, Desheng;Meng, Shuqi;Ruan, Tianming;Hu, Yisong;Zhang, Ziyu
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.984-990
    • /
    • 2022
  • Corrosion release behavior of Alloy 690 in high-temperature water was investigated under the conditions of injected Zn concentrations of 0 ppb, 10 ppb and 50 ppb. A protective oxide film composed of Zn(FexCr1-x)2O4 and Cr2O3 was formed with Zn injection, resulting in a better corrosion resistance. In comparison with the Zn-free condition, the corrosion release rate under the Zn-injection conditions was smaller. The corrosion release inhibiting factors were 1.7 and 1.9 under the conditions of 10 ppb and 50 ppb Zn-injection respectively. A foreseen application of the corrosion and corrosion release rates has been proposed and discussed.

에너지플러스 시뮬레이션을 통한 하천수 열원 히트펌프 시스템의 적용 가능성 분석 (An Applicability Analysis of River Water Source Heat Pump System using EnergyPlus Simulation)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권2호
    • /
    • pp.10-21
    • /
    • 2022
  • A water source heat pump (WSHP) system is regarded as an energy-efficiency heating and cooling supply system for buildings due to its high energy efficiency and low greenhouse gas emissions. Recently, water sources such as river water, lake water, and raw water are attracting attention as heat sources for a heat pump system in Korea. This paper analyzed the applicability of a river water source heat pump system (RSHP). The river water temperature level was compared with the outdoor air and ground temperature levels to present applicability. In addition, the cooling and heating performance were compared through a simulation approach for the RSHP and a ground source heat pump (GSHP) applied to a large-scale office building. To compare the temperature level, the actual data were applied to the river water and the outdoor air, while the simulation results were applied to the ground circulation water. The results showed that the change in river water temperature throughout the year was similar to the change in outdoor air temperature. However, unlike the outdoor air temperature, the difference between the hourly and daily average river water temperatures was not large. The temperature level of river water was lower during the heating season and somewhat higher during the cooling season than that of the ground circulation water. Finally, the performance of the RSHP system was 13.4% lower than that of the GSHP system on an annual-based.

Raman Lidar for the Measurement of Temperature, Water Vapor, and Aerosol in Beijing in the Winter of 2014

  • Tan, Min;Shang, Zhen;Xie, Chenbo;Ma, Hui;Deng, Qian;Tian, Xiaomin;Zhuang, Peng;Zhang, Zhanye;Wang, Yingjian
    • Current Optics and Photonics
    • /
    • 제2권1호
    • /
    • pp.15-22
    • /
    • 2018
  • To measure atmospheric temperature, water vapor, and aerosol simultaneously, an efficient multi-function Raman lidar using an ultraviolet-wavelength laser has been developed. A high-performance spectroscopic box that utilizes multicavity interference filters, mounted sequentially at small angles of incidence, is used to separate the lidar return signals at different wavelengths, and to extract the signals with high efficiency. The external experiments are carried out for simultaneous detection of atmospheric temperature, water vapor, and aerosol extinction coefficient in Beijing, under clear and hazy weather conditions. The vertical profiles of temperature, water vapor, and aerosol extinction coefficient are analyzed. The results show that for an integration time of 5 min and laser energy of 200 mJ, the mean deviation between measurements obtained by lidar and radiosonde is small, and the overall trend is similar. The statistical temperature error for nighttime is below 1 K up to a height of 6.2 km under clear weather conditions, and up to a height of 2.5 km under slightly hazy weather conditions, with 5 min of observation time. An effective range for simultaneous detection of temperature and water vapor of up to 10 km is achieved. The temperature-inversion layer is found in the low troposphere. Continuous observations verify the reliability of Raman lidar to achieve real-time measurement of atmospheric parameters in the troposphere.

PCB 절연체에서 전하 형성과 수분 흡수 (Water Absorption and Charge Formation in PCB)

  • 이정수;황종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.233-234
    • /
    • 2008
  • We observed internal space charge behavior for two types of epoxy composites under dc electric fields to investigate the influence of water at high temperature. In the case of glass/epoxy specimen, homocharge is observed at water-treated specimen, and spatial oscillations become clearer in the water-treated specimens. Electric field in the vicinity of the electrodes shows the injection of homocharge. In aramid/epoxy specimens, heterocharge is observed at water-treated specimens, i.e. negative charge accumulates near the anode, while positive charge accumulates near the cathode. Electric field is enhanced just before each electrode. In order to further examine the mechanism of space charge formation, we have developed a new system that allows in situ space charge observation during ion migration tests at high temperature and high humidity. Using this in situ system.

  • PDF

PCB 절연체에서 전하 형성과 수분 흡수의 영향 (Influence of Water Absorption and Charge Formation in PCB)

  • 구정현;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2307-2308
    • /
    • 2008
  • We observed internal space charge behavior for two types of epoxy composites under dc electric fields to investigate the influence of water at high temperature. In the case of glass/epoxy specimen, homocharge is observed at water-treated specimen, and spatial oscillations become clearer in the water-treated specimens. Electric field in the vicinity of the electrodes shows the injection of homocharge. In aramid/epoxy specimens, heterocharge is observed at water-treated specimens, i.e. negative charge accumulates near the anode, while positive charge accumulates near the cathode. Electric field is enhanced just before each electrode. In order to further examine the mechanism of space charge formation, we have developed a new system that allows in situ space charge observation during ion migration tests at high temperature and high humidity. Using this in situ system.

  • PDF

고온조건에서 콘크리트 부재의 온도전이 (Beat Transfer Analysis of Concrete Members under High Temperature)

  • 이태규;김혜욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1536-1541
    • /
    • 2009
  • When water inside the concrete member evaporates by high temperature, the evaporation heat which absorbs surrounding temperature occurs. The rate of increment of the internal temperature in concrete is reduced due to the evaporation heat in spite of continuously increasing external temperature. In this paper, the prediction method of internal temperature of high strength concrete members considering the evaporation heat under the high temperature is presented. Finite element method is employed to facilitate thermal analysis for any position of member. And the thermal characteristics models of high strength concrete affected by high temperature are proposed. To demonstrate the validity of this numerical procedure, the prediction by the proposed algorithm is compared with the test results of other researchers. The proposed algorithm shows a good agreement with the experimental results including the phenomenon that temperature is lost by the evaporation heat.

  • PDF

절식, 수온 및 유속이 극동산 뱀장어(Anguilla japonica) 렙토세팔루스의 변태 유도에 미치는 영향 (Effects of Starvation, Water Temperature, and Water Flow on the Metamorphosis of Leptocephalus of Japanese Eel Anguilla japonica)

  • 김대중;이남실;김경길;장대수
    • 한국수산과학회지
    • /
    • 제47권5호
    • /
    • pp.597-602
    • /
    • 2014
  • We determined the effects of starvation, water temperature, and water flow on the onset of metamorphosis in leptocephali of the Japanese eel Anguilla japonica. Leptocephali larger than 50 mm (ca. 200 days old) were reared in 10-L tanks under different feeding, water temperature, and water flow regimes. Fasted leptocephali metamorphosed earlier and faster than did the fed ones. Metamorphosis was faster in the high water flow tank (1.2 L/min) than in the tank with flow at 0.6 L/min. The duration of metamorphosis was slightly shorter at $26^{\circ}C$ than at $23^{\circ}C$. To conclude, starvation induced the metamorphosis of artificially produced leptocephali larger than 50 mm TL. Increased water flow and water temperature both appear to induce and shorten metamorphosis.

단효용 LiBr/물 흡수식 냉동사이클의 성능특성에 관한 연구 (A Study on Performance Characteristics of A Single Effect LiBr/Water Refrigeration Cycle)

  • 연제문;임삼택;오주원;이경우
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.95-99
    • /
    • 2001
  • As a way to use energy effectively, the present study is aimed at investigating the performance characteristics of a Single Effect LiBr/Water Absorption Refrigerator using a low temperature driving heat-source. It was carried out by changing the driving heat-source temperature, the cold water outlet temperature(the refrigeration load), the cooling water inlet temperature, and the weak solution flow rate and this study compares the performance characteristics of refrigerator against the existence and non-existence of the Recirculation of the Weak solution which is used as a method to improve the performance of refrigerator. In case of Recirculation of the weak solution, more improved the Refrigeration Capacity and COP was obtained, and these effects became more larger in the high temperature of driving heat-source and large quantity of solution.

  • PDF

Observation of Water Level and Temperature Properties by using a Giant Magnetoresistance-Spin Valve Film

  • Choi, Jong-Gu;Park, Kwang-Jun;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제17권3호
    • /
    • pp.214-218
    • /
    • 2012
  • The water level and temperature properties for the cooling system of potassium titanyl phosphate laser systems were observed. The middle point of the GMR-SV magnetoresistance curve is set in the neighborhood of high magnetic sensitivity (2.8 %/Oe). The experimental results for resistance dependence on water height and temperature showed linear regions with rates of 0.4 ${\Omega}/mm$ and 0.1 ${\Omega}/^{\circ}C$, respectively. The proposed results were found to be for adjusting the water level and temperature in the laser cooling system.