• Title/Summary/Keyword: high temperature state

검색결과 1,600건 처리시간 0.033초

600 V급 IGBT Single N+ Emitter Trench Gate 구조에 따른 전기적 특성 (Study on the Electrical Characteristics of 600 V Trench Gate IGBT with Single N+ Emitter)

  • 신명철;육진경;강이구
    • 한국전기전자재료학회논문지
    • /
    • 제32권5호
    • /
    • pp.366-370
    • /
    • 2019
  • In this paper, a single N+ emitter trench gate-type insulated gate bipolar transistor (IGBT) device was studied using T-CAD, in order to achieve a low on-state voltage drop (Vce-sat) and high breakdown voltage, which would reduce power loss and device reliability. Using the simulation, the threshold voltage, breakdown voltage, and on-state voltage drop were studied as a function of the temperature, the length of time in the diffusion process (drive-in) after implant, and the trench gate depth. During the drive-in process, a $20^{\circ}C$ change in temperature from 1,000 to $1,160^{\circ}C$ over a 150 minute time frame resulted in a 1 to 4 V change in the threshold voltage and a 24 to 2.6 V change in the on-state voltage drop. As a result, a 0.5 um change in the trench depth of 3.5 to 7.5 um resulted in the breakdown voltage decreasing from 802 to 692 V.

고온초전도체 $Y_1Ba_2Cu_3O_{7-y}$의 자기이방성 (Magnetic Anisotropy in High $T_c\;Y_1Ba_2Cu_3O_{7-y}$ Superconductor)

  • 김문석;유성초;임우영;백종성
    • 한국자기학회지
    • /
    • 제2권3호
    • /
    • pp.228-232
    • /
    • 1992
  • 고온초전도체 $Y_1Ba_2Cu_3O_{7-y}$의 grain을 높은 자기장에서 정렬시켜 여러가지 자기적 특성을 조사하였다. Grain이 정렬된 초전도체는 단결정과 같이 Cu-O layer에 수직, 수평 방향에 대해 자기이방성을 가진다. 2~77 K의 온도영역에서 측정한 lower critical field$(H_{c1})$은 온도가 증가하면서 선형적으로 감소하였는데, Cu-O layer에 대하여 외부 자기장이 수직인 경우가 더욱 급격히 감소하였다. 온도변화에 따른 자율화$(4{\pi}\;X)$의 측정으로부터 극저온의 자화율이 -1에 가까운 값을 가진다는 것을 알 수 있었다. 또한 이 자화 곡선을 London의 공식과 two-fluid model을 이용해 최소자승법으로 fitting하여 절대 영도에서 침투깊이$({\lambda}_0)$를 구하였다. 또한 2 K에서 외부 자기장에 따른 자화곡선을 측정하였으며, Bean의 critical state model을 이용한 임계전류밀도$(J_c)$의 계산으로부터 grain내부는 단결정 수준의 높은 $(J_c)$를 가지고 있음을 알 수 있었다.

  • PDF

Wood Flour 폴리프로필렌 복합재료의 기계적 특성: 반복적 온도 변화의 영향 (Mechanical Properties of Wood Flour Polypropylene Composites: Effect of Cycled Temperature Change)

  • 이선영;전상진;도금현;박상범;최수임
    • Elastomers and Composites
    • /
    • 제46권3호
    • /
    • pp.218-222
    • /
    • 2011
  • 본 연구에서는 반복적인 온도변화가 목분(50 wt.%와 70 wt.%)이 첨가된 폴리프로필렌 WPC(Wood Plastic Composites)의 기계적 특성에 미치는 영향을 조사하였다. WPC의 휨탄성계수(flexural modulus)와 휨강도 (flexural strength)는 반복 회수에 상관없이 동결 융해 시험에서 계면접착력의 약화 때문에 감소하는 경향을 보였다. 목분의 함량이 높을 때, 휨탄성계수의 감소가 비교적 높았다. WPC의 휨탄성계수와 휨강도는 고온($60^{\circ}C$) 저온 ($-20^{\circ}C$) 반복시험 후 고온에서 감소하고 저온에서 증가되었다. 폴리프로필렌(polypropylene, PP)의 유리전이점 (glass transition temperature: $-10^{\circ}C$) 보다 낮은 저온($-20^{\circ}C$에서 WPC는 높은 강성(stiffness)과 강도 (strength)를 유발시키는 유리상태(glassy state)로 존재한다. 고온에서 목분의 함량이 낮은 WPC가 연성의 증가 때문에 낮은 휨탄성계수와 휨강도를 보였다.

자동차용 이산화탄소 냉방 시스템의 정상상태 및 동적 특성에 관한 연구 (Studies on the Steady State and Dynamic Characteristics of a Carbon Dioxide Air-Conditioning System for Vehicles)

  • 박민수;김성철;김달원;김민수
    • 대한기계학회논문집B
    • /
    • 제31권6호
    • /
    • pp.531-538
    • /
    • 2007
  • In this study, an air conditioning system using carbon dioxide as a refrigerant was developed for automotive cabin cooling. Experiments have been carried out to examine the steady state and dynamic characteristics of this system. The system consists of a compressor, a gas cooler, an evaporator, an expansion device, an internal heat exchanger and an accumulator. The compressor is a variable displacement type, driven by the electric motor, and the gas cooler and the evaporator are aluminum extruded heat exchangers of micro channel type. The $CO_2-refrigerant$ charge, the compressor speed, the air inlet temperature of the gas cooler, the air inlet temperature and the air flow rate of the evaporator and the cooling load are varied and the performance of the system is experimentally investigated. As the compressor speed increased, cooling capacity increased, but the coefficient of performance was deteriorated. As the cabin air temperature or the air flow rate to the cabin was set high, both the cooling capacity and the COP increased. In the cool down experiment with 1.0 or 2.0 kW of heat load, the dynamic characteristics of the air-conditioning system were investigated. For a given capacity of compressor, cool down speed was monitored, and the temperature change was acceptable fur low heat load condition.

경주 기림사 소장 지류문화재의 보존실태 및 대책 (The investigation on the actual conditions and the conservation on the countmeasure paper cultural properties stored in Kirimsa temple)

  • 한성희;이규식;정용재
    • 보존과학연구
    • /
    • 통권19호
    • /
    • pp.75-107
    • /
    • 1998
  • The cultural properties of paper made from 11 to 16th century of the Kirimsa temple were found in Birozana Buddhist Statue which was made from 15 to 16th century. These have been stored and exhibited in the exhibition showcase. To examine the environment of conservation and the state of paper, we investigated the temperature and the relative humidity in the inside and outside of the Kirimsa museum and examined the external form and the internal state (water content, acidity and whiteness) of paper. During the investigation period from 27 Aug. to 30 Aug. 1997. The average of temperature and relative humidity were $28.2^{\circ}C$, 67% in the outside and $27.1^{\circ}C$, 73% in the inside, respectively. These indicated the air conditioning was wrong. Among the cultural properties of 79 papers stored in the Kirimsa museum, 37 cases had been repaired but 42 cases not. From the result examining the external form, 20 cases needed to repair. In the internal state of the cultural properties of paper, the water contents were from 11.9% to 16.5%, the average was 15.7%, the acidities from pH 5.7 to pH 6.2 and the whiteness from 37 to 45. From these results, we could see the cultural properties of paper stored in the Kirimsa museum was damaged by the several factors (hydrolysis by fungi, repeated elongation and retraction of cellulose) caused mainly by the high temperature and relative humidity. Therefore, for the conservation of the cultural properties of paper stored in the Kirimsa museum, it need to control the temperature at $18~20^{\circ}C$ and the relative humidity at $55\pm5%$ by the appropriate air conditioning. In order to sterilize fungi occurred to the surface of paper, the cultural properties of paper needed to fumigate. The fungi occurred on the surface of paper were wiped out by using of 70%solution dissolved thymol in ethyl alcohol.

  • PDF

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

  • Hyeongi Moon ;Sujong Yoon;Mauricio Tano-Retamale ;Aaron Epiney ;Minseop Song;Jae-Ho Jeong
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3874-3897
    • /
    • 2023
  • A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High-Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next-generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds-averaged Navier-Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

환상유로에 있어서 수직고온관의 과도적 냉각과정에 관한 연구 (A study on the transient cooling process of a vertical-high temperature tube in an annular flow channel)

  • 정대인;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.156-164
    • /
    • 1986
  • In the case of boiling on high temperature wall, vapor film covers fully or parcially the surface. This phenomenon, film boiling or transition boiling, is very important in the surface heat treatment of metal, design of cryogenic heat exchanger and emergency cooling of nuclear reactor. Mainly supposed hydraulic-thermal accidents in nuclear reactor are LCCA (Loss of Coolant Accident) and PCM (Power-Cooling Mismatch). Recently, world-wide studies on reflooding of high temperature rod bundles after the occurrence of the above accidents focus attention on wall temperature history and required time in transient cooling process, wall superheat at rewet point, heat flux-wall superheat relationship beyond the transition boiling region, and two-phase flow state near the surface. It is considered that the further systematical study in this field will be in need in spite of the previous results in ref. (2), (3), (4). The paper is the study about the fast transient cooling process following the wall temperature excursion under the CHF (Critical Heat Flux) condition in a forced convective subcooled boiling system. The test section is a vertically arranged concentric annulus of 800 mm long and 10 mm hydraulic diameter. The inner tube, SUS 304 of 400 mm long, 8 mm I.D, and 7 mm O.D., is heated uniformly by the low voltage AC power. The wall temperature measurements were performed at the axial distance from the inlet of the heating tube, z=390 mm. 6 chromel- alumel thermocouples of 76 .mu.m were press fitted to the inner surface of the heating tube periphery. To investigate the heat transfer characteristics during the fast transient cooling process, the outer surface (fluid side) temperature and the surface heat flux are computed from the measured inner surface temperature history by means of a numerical method for inverse problems of transient heat conduction. Present cooling (boiling) curve is sufficiently compared with the previous results.

  • PDF

고속 주축베어링의 볼 접촉각 변동을 고려한 주축 설계공차 (Design Tolerance of High Speed Spindle considering the Variation of Ball Contact Angle in the Angular Contact Ball Bearings)

  • 이찬홍
    • 한국생산제조학회지
    • /
    • 제19권5호
    • /
    • pp.609-615
    • /
    • 2010
  • Angular contact ball bearings in a high speed spindles are under the extreme conditions, such as high temperature, big centrifugal force and thrust cutting forces. So, the assembly contacts between spindle shaft and inner ring bearings, bearing housing and outer ring of bearings are occasionally unstable at high speed revolution. Furthermore, the ball contact angle of a bearing, which influence stiffness and lifetime of bearings, are changed according to loads and rotational speed. To analyze internal forces of a bearing under high speed revolution, the ball contact are calculated using nonlinear equations in consideration of rotational speed, thrust loads and raceway form. Diameter increase of inner and outer ring by influence factors, such as internal forces to inner and outer ring, centrifugal force and temperature of inner and outer rings are calculated to establish stable state in bearing assembly in high speed spindle. Finally, contribution ratio of influence factor to assembly design tolerance of inner and outer rings are shown and the stable assembly design tolerance are proposed.

데이터센터의 급기온도 변화가 서버 냉각 성능에 미치는 영향에 대한 연구 (A Study on the Effects of Supply Air Temperature on the Server Cooling Performance in a Data Center)

  • 장현재
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.83-91
    • /
    • 2018
  • A datacenter is a high energy consuming facility whose cooling energy consumption rate is 10~20 times larger than general office buildings. The higher the temperature of supply air from a CRAC (computer room air-conditioner) is supplied, the more energy efficient cooling is possible because of improving the COP of a chiller and advanced range of outdoor air temperature available for the economizer cycles. However, because the temperature of cold air flowing into server computers varies depending on air mixing configurations in a computer room, the proper supply air temperature must be considered based on the investigation of air mixing and heat dissipation. By these, this study aims to understand the effects of variation of the supply air temperature on the air flow distributions, temperature distributions and rack cooling efficiencies. Computational fluid dynamics (CFD) aided in conducting the investigation. As a result, the variation of the supply air temperature does not affect the air flow distributions. However, it mainly affects the temperature distribution. From the results of CFD simulations, Rack cooling indices (RCIHI and RCILO) were evaluated and showed the ideal state set at $19^{\circ}C$ of the supply air temperature.

고주파 모터 내장형 주축의 냉각특성 해석 (Analysis on the Cooling Characteristics of the Swindle with High Frequency Motor)

  • 김수태;창원대;최대봉
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.278-283
    • /
    • 2002
  • Cooling characteristics for the three type spindles with high frequency motor are studied. For the analysis, three dimensional models are built considering heat transfer characteristics such as natural and forced convection coefficients. Unsteady-state temperature distributions and thermal deformations according to the cooling conditions are analyzed by using the finite element method.

  • PDF