• Title/Summary/Keyword: high temperature humidity test

Search Result 191, Processing Time 0.025 seconds

Reliability Testing and Materials Evaluation of Si Sub-Mount based LED Package (실리콘 서브 마운틴 기반의 LED 패키지 재료평가 및 신뢰성 시험)

  • Kim, Young-Pil;Ko, Seok-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.1-10
    • /
    • 2015
  • The light emitting diodes(LED) package of new structure is proposed to promote the reliability and lifespan by maximize heat dissipation occurred on the chip. We designed and fabricated the LED packages mixing the advantages of chip on board(COB) based on conventional metal printed circuit board(PCB) and the merits of Si sub-mount using base as a substrate. The proposed LED package samples were selected for the superior efficiency of the material through the sealant properties, chip characteristics, and phosphor properties evaluations. Reliability test was conducted the thermal shock test and flux rate according to the usage time at room temperature, high-temperature operation, high-temperature operation, high-temperature storage, low-temperature storage, high-temperature and high-humidity storage. Reliability test result, the average flux rate was maintained at 97.04% for each items. Thus, the Si sub-mount based LED package is expected to be applicable to high power down-light type LED light sources.

Accelerated Testing of Coated VCR Drum Under Various Environmental Conditions (환경변화에 따른 VCR 코팅드럼의 가속실험)

  • Park, U-Hyeon;Hwang, Dong-Hwan;Kim, Dae-Eun;Lee, Sang-Jo;Yoo, Dae-Eun;Kim, Geum-Mo;Choi, Gye-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3095-3104
    • /
    • 1996
  • The tribological characteristics of TIN and DLC coated VCR drums were compared to conventional aluminum drums using a custom built accelerated testing set-up under varying temperature and humidity. It is found that the coated drums exhibit superior frictional properties at elevated temperature and high humidity compared to bare aluminum drum. Futhermore, the coated drums maintained their initial surface conditions over a wider range of temperature and humidity variation. As for the damage incurred to the tape, DLC coated drum was the most favorable of the three types of drums.

A Study on Reliability Assessment of Ag-free Solder (무은 솔더의 신뢰성 평가에 관한 연구)

  • Kim, Jong-Min;Kim, Gi-Young;Kim, Kang-Dong;Kim, Seon-Jin;Jang, Joong Soon
    • Journal of Applied Reliability
    • /
    • v.13 no.2
    • /
    • pp.109-116
    • /
    • 2013
  • The solder is any of various fusible alloys, usually tin and lead, used to join metallic parts that provide the contact between the chip package and the printed circuit board. Solder plays an important role of electrical signals to communicate between the two components. In this study, two kinds of Ag-free solder as sample is made to conduct the thermal shock test and the high humidity temperature test. Low resistance is measured to estimate crack size of solder, using daisy chain. The low speed shear test is also performed to analyze strength of solder. The appropriate degradation model is estimated using the result data. Depending on the composition of solder, lifetime estimation is conducted by adopted degradation model. The lifetime estimated two kinds of Ag-free solder is compared with expected lifetime of Sn-Ag-Cu solder. The result is that both Ag-free composition are more reliable than Sn-Ag-Cu solder.

DEVELOPMENT OF AN AUTOMATIC ENVIRONMENTAL CONTROL SYSTEM FOR LOW TEMPERATURE STORAGE HOUSE USING INTERNET

  • Chung, H.;Yun, H.S.;Lee, W.O.;Lee, K.H.;Cho, Y.K.;Park, W.K.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.676-683
    • /
    • 2000
  • For high quality storage of agricultural products, temperature, humidity and gas conditions in a storage house should be controlled properly. But most of the low temperature storage house is depending on temperature control. This study aimed to develop an automatic control system for low temperature storage house that can control storage conditions such as temperature, humidity and $CO_2$ gas concentration. The developed system alarms the user, by telephone or beeper, when abnormal condition has occurred. The farmer can also monitor the inside condition of warehouse in his residence, by Internet. From the results of the performance test, the temperature and relative humidity in the warehouse is controlled within the range of ${\pm}0.5^{circ}C$ and ${\pm}2%$, respectively.

  • PDF

A Study on the Plate for Deep Discharge in Lead Acid Battery (납축전지의 심방전용 극판에 관한 연구)

  • Jeong, Soon-Wook;Ku, Bon-Keun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.197-202
    • /
    • 2014
  • Positive plate was composed of lead hydroxide via reaction between lead oxide and $H_2O$ and lead sulfate was formed of the reaction of lead hydroxide with sulfuric acid. And its density is $3.8g/cm^3$, $4.0g/cm^3$, $4.2g/cm^3$ and $4.4g/cm^3$ by controlling volume of refined water. Curing of positive plate is done for low ($45^{\circ}C$, 40hr, over 95% of relative humidity) & high ($80^{\circ}C$, 40hr, over 95% of relative humidity) temperature, which created 3BS & 4BS active materials. Experimental result of DOD with 100% life cycle test shows that it was not related to the density of active materials but to the low & high temperature aging of active materials. The test makes us to understand that the crystallization which is made by curing of active materials is a more of a main factor than density of active materials under the deep cycle using circumstances. The active materials which were from the high temperature curing are better for deep cycle performance.

The Study on the Physiological Response in Wearing Sportswear in Two Different Environments

  • Kwon, Oh Kyung;Kim, Jin-A
    • Fashion & Textile Research Journal
    • /
    • v.2 no.5
    • /
    • pp.416-422
    • /
    • 2000
  • In this study, to find out the physiological reaction of the human body and the sensation of comfort when people are wearing sportswear which is made of waterproof breathable fabrics under general environmental conditions (temperature : $20{\pm}1^{\circ}C$, humidity : $60{\pm}5%RH$, air current : 0.1 m/sec) and rainy environmental conditions (temperature : $20{\pm}1^{\circ}C$, humidity : $60{\pm}5%RH$, air current : 0.1 m/sec, rainfall : 250 1/hr), we made an experiment with sportswear in an artificial climate chamber and studied the thermal physiological response and subjective sensation. Mean skin temperature of the subjects was low and had a big range of fluctuation in rainy environmental conditions of two condition. Temperature started to increase at the beginning of the exercise, reached the maximum at the 2nd level of the exercise and then started to decline. Rectal temperature showed a slighter increase and bigger range of fluctuation in general conditions than in rainy conditions. Except clothing micro climate in rainy conditions, temperature and humidity and their range of fluctuation around back were higher than those around chest. Humidity was high and had wide range of fluctuation in general conditions. Heart rate was 4.4 beats/min higher in general conditions. In subjective test on rainy conditions, the feeling of discomfort increased due to the raindrops fallen on the skin. Unlike that in general conditions, cold sensation increased and humidity sensation reached to the peak after the exercise. In wearing sportswear made of shape memory breathable waterproof fabric, controlling function over a small amount of heat and water was distinctive while it turned out to be not so comfortable over a large amount of heat and water. Through this, the limitation of shape memory breathable waterproof fabric was recognised.

  • PDF

A Study on the Reliability Prediction about ECM of Packaging Substrate PCB by Using Accelerated Life Test (가속수명시험을 이용한 Packaging Substrate PCB의 ECM에 대한 신뢰성 예측에 관한 연구)

  • Kang, Dae-Joong;Lee, Hwa-Ki
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.109-120
    • /
    • 2013
  • As information-oriented industry has been developed and electronic devices has come to be smaller, lighter, multifunctional, and high speed, the components used to the devices need to be much high density and should have find pattern due to high integration. Also, diverse reliability problems happen as user environment is getting harsher. For this reasons, establishing and securing products and components reliability comes to key factor in company's competitiveness. It makes accelerated test important to check product reliability in fast way. Out of fine pattern failure modes, failure of Electrochemical Migration(ECM) is kind of degradation of insulation resistance by electro-chemical reaction, which it comes to be accelerated by biased voltage in high temperature and high humidity environment. In this thesis, the accelerated life test for failure caused by ECM on fine pattern substrate, $20/20{\mu}m$ pattern width/space applied by Semi Additive Process, was performed, and through this test, the investigation of failure mechanism and the life-time prediction evaluation under actual user environment was implemented. The result of accelerated test has been compared and estimated with life distribution and life stress relatively by using Minitab software and its acceleration rate was also tested. Through estimated weibull distribution, B10 life has been estimated under 95% confidence level of failure data happened in each test conditions. And the life in actual usage environment has been predicted by using generalized Eyring model considering temperature and humidity by developing Arrhenius reaction rate theory, and acceleration factors by test conditions have been calculated.

Effects of High Relative Humidity on Weight Loss, Color Change, and Microbial Activity of Tomatoes during Refrigerated Storage

  • Pai, Tongkun
    • Journal of Applied Biological Chemistry
    • /
    • v.43 no.4
    • /
    • pp.250-253
    • /
    • 2000
  • The effects of high relative humidity (RH) on the physicochemical properties and microbial activity of mature green tomatoes ('Dombito') during refrigerated storage were determined at three temperatures (5, 10, and $15^{\circ}C$) and four different RH levels (91, 94, 97, and 99%). At each temperature, the weight loss rates of tomatoes at different levels of RH were significantly (p<0.05) different from each other. For the samples stored at $10^{\circ}C$, the weight losses were generally higher than those for the samples at $15^{\circ}C$ within the same RH level (i.e., greater vapor pressure deficit). The color change rates ('a' value) showed positive slopes, indicating that the tomato color was changing from green to red. Neither bacteria nor fungi caused visible damages to the samples, and the microbial counts were below 650 colony forming units/$cm^2$ during the test period.

  • PDF

Effect of operating conditions on carbon corrosion in High temperature polymer electrolyte membrane fuel cells (HT-PEMFCs) (고온형 고분자 전해질막 연료전지(HT-PEMFC) 구동환경에 따른 탄소 담지체 부식 평가)

  • Lee, Jinhee;Kim, Hansung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.89.1-89.1
    • /
    • 2011
  • The influence of potential and humidity on the electrochemical carbon corrosion in high temperature polymer electrolyte membrane fuel cells(HT-PEMFCs) is investigated by measuring $CO_2$ emission at different potentials for 30 min using on-line mass spectrometry. These results are compared with low tempterature polymer electrolyte membrane fuel cells(LT-PEMFCs) operated at lower temperature and higher humidity condition. Although the HT-PEMFC is operated at non humidified condition, the emitted $CO_2$ in the condition of HT-PEMFC is more than LT-PEMFC at the same potential in carbon corrosion test. Thus, carbon corrosion shows a stronger positive correlation with the cell temperature. In addition, the presence of a little amount of water activate electrochemical carbon corrosion considerably in HT-PEMFC. With increased carbon corrosion, changes in fuel cell electrochemical characteristics become more noticeable and thereby indicate that such corrosion considerably affects fuel cell durability.

  • PDF