• Title/Summary/Keyword: high temperature environment service

Search Result 80, Processing Time 0.026 seconds

A Study on Electrochemical Evaluation Method of Toughness Degradation for 12%Cr Steel (II) (12%Cr강 인성열화도의 전기화학적 평가법에 대한 연구(II))

  • Kim, Chang-Hui;Seo, Hyun-Uk;Yoon, Kee-Bong;Park, Ki-Sung;Kim, Seoung-Tae
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.268-273
    • /
    • 2001
  • Fossil power plants operated in high temperature condition are composed of components such as turbine, boiler, and piping system. Among these components, turbine blades made with 12%Cr steel operate at a temperature above $500^{\circ}C$. Due to the long term service, turbine blades experience material degradation manifested by change in mechanical and microstructural properties. The need to make life assessment and to evaluate material degradation of turbine blade is strongly required but in reality, there is a lack of knowledge in defining failure mechanism and fundamental data for this component. Therefore, in making life assessment of turbine blade, evaluation of material degradation must be a priority. For this purpose, evaluation of toughness degradation is very important. The major cause of toughness degradation in 12Cr turbine blade is reported to be critical corrosion pitting induced by segregation of impurity elements(P etc.), coarsening of carbide, and corrosion, but the of materials for in-service application. In this study, the purpose of research is focused on evaluating toughness degradation with respect to operation time for 12%Cr steel turbine blade under high temperature steam environment and quantitatively detecting the degradation properties which is the cause of toughness degradation by means of non-destructive method, electrochemical polarization.

  • PDF

A Study on the Habitat Environment Survey and Conservation of Rhododendron micranthum in National Baekdudaegan Arboretum (국립백두대간수목원 꼬리진달래 자생지 환경특성 및 보전방안)

  • Chung, Bo-Kwang;Gang, Sin-Gu;Bae, Jun-Gyu;Kim, Jae-Hyeon;Lee, Juyoung;Chang, Jeong-Won;Lee, Sang-Hyun;Lee, Yeong-Su;An, Min-Woo;Kim, Gi-Song
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.19 no.6
    • /
    • pp.87-100
    • /
    • 2016
  • This research was performed for the purpose of providing useful and base data and preservation strategy of growth characteristics of Rhododendron micranthum. From the result of research, wild growth area of Rhododendron micranthum was discovered near steep forest road on 695~901m in altitude above sea level of Baekdu-daegan National Arboretum. Vegetation colony structure of Site I was resulted in Pinus densiflora(tree stratum M.I.P.=45.3%) is dominants, Betula schmidtii(arborescent M.I.P.=9.8%) is second dominant, and Site III resulted in Pinus densiflora(tree stratum M.I.P.=30.5%) is dominants, Betula schmidtii(arborescent M.I.P.=10.3%) is second dominant. Site II resulted in Betula schmidtii(arborescent M.I.P.=30.4%) is dominants and Pinus densiflora tree(tree stratum M.I.P.=8.3%) is second dominants. For herbs, it was researched that the rate of one year herb of chrysanthemum family(10), rice family(3), sedge(2) was higher than near forest area. Among Species diversity index, that of Shannon was in range of 0.7348~1.1090. After comparing this with similar area, this value was relatively low. Dominance analysis result was analyzed that various groups are evenly distributed. Monthly highest average temperature is $23.9^{\circ}$ in Site A and Site B, and monthly lowest average temperature is $-4.5^{\circ}C$ in Site I and $-4.7^{\circ}C$ in Site II. Monthly maximum average humidity is 85.6% in Site I and 83.2% in Site II. Monthly minimum average humidity is 60.9% in Site I and 60.8% in Site II and it showed that these 2 area are located far away but have similar temperature and humidity characteristic and climate environment is similar. It was analyzed that humidity is high with the result of annual average humidity is over 60%. In growth characteristic, it showed that doubt damage of Stephanitis pyrioides, exposure of roots, peeled bark was discovered and supplement on this is urgent.

Microstructure and Mechanical Properties of High-Strength Low-Carbon Bainitic Steels with Enhanced Deformability (높은 변형능을 갖는 저탄소 베이나이트계 고강도강의 미세조직과 기계적 특성)

  • Hwang, Byoungchul
    • Korean Journal of Materials Research
    • /
    • v.23 no.8
    • /
    • pp.423-429
    • /
    • 2013
  • Recently, steel structures have increasingly been required to have sufficient deformability because they are subjected to progressive or abrupt displacement arising from structure loading itself, earthquake, and ground movement in their service environment. In this study, high-strength low-carbon bainitic steel specimens with enhanced deformability were fabricated by varying thermo-mechanical control process conditions consisting of controlled rolling and accelerated cooling, and then tensile and Charpy V-notch impact tests were conducted to investigate the correlation between microstructure and mechanical properties such as strength, deformability, and low-temperature toughness. Low-temperature transformation phases, i.e. granular bainite (GB), degenerate upper bainite(DUB), lower bainite(LB) and lath martensite(LM), together with fine polygonal ferrite(PF) were well developed, and the microstructural evolution was more critically affected by start and finish cooling temperatures than by finish rolling temperature. The steel specimens start-cooled at higher temperature had the best combination of strength and deformability because of the appropriate mixture of fine PF and low-temperature transformation phases such as GB, DUB, and LB/LM. On the other hand, the steel specimens start-cooled at lower temperature and finish-cooled at higher temperature exhibited a good low-temperature toughness because the interphase boundaries between the low-temperature transformation phases and/or PF act as beneficial barriers to cleavage crack propagation.

Characteristics of Variation of Sea Surface Temperature in the East Sea with the Passage of Typhoons (태풍의 이동경로에 따른 동해연안 수온변화 특성)

  • Park, Myung-Hee;Lee, Joon-Soo;Suh, Young-Sang;Kim, Hae-Dong;Bae, Hun-Kyun
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1657-1671
    • /
    • 2015
  • In this study, the wind direction and the wind speed of the nearest temperature observations point of the National Weather Service was analyzed in order to investigate the rapid rise and drop of water temperature in the East Coast appeared after passing of the 2015 typhoon No. 9 and 11. Then the figures were simulated and analyzed using the WRF(weather research and forecast) model to investigate in more detailed path of the typhoon as well as the changes in the wind field. The results were as follows. A sudden drop of water temperature was confirmed due to upwelling on the East coast when ninth typhoon Chanhom is transformed from tropical cyclones into extra tropical cyclone, then kept moving eastwards from Pyongyang forming a strong southerly wind after 13th and this phenomenon lasted for two days. The high SST(sea surface temperature) is confirmed due to a strong northerly wind by 11th typhoon Nangka. This strong wind directly affected the east coast for three days causing the Ekman effect which transported high offshore surface waters to the coast. The downwelling occurred causing an accumulation of high temperature surface water. As a results, the SST of 15m and 25m rose to that of 5m.

Analysis of Meteorological and Radiation Characteristics using WISE Observation Data (WISE 관측자료를 이용한 기상 및 복사 특성 분석)

  • Lee, Hankyung;Jee, Joon-Bum;Min, Jae-Sik;Kim, Sangil;Chae, Jung-Hoon
    • Journal of the Korean earth science society
    • /
    • v.39 no.1
    • /
    • pp.89-102
    • /
    • 2018
  • We analyzed the meteorological and radiation characteristics of Seoul metropolitan area using data from energy flux towers that were installed and operated by the Weather Information Service Engine (WISE). The meteorological and radiation variables included temperature, pressure, wind speed, wind direction, relative humidity, surface temperature, rainfall amount, upward and downward solar radiation, upward and downward longwave radiation, albedo and emissivity from 14 energy flux stations located in the Seoul metropolitan area from July 2016 to July 2017. According to the monthly data during the period, the albedo is low and emissivity is high at the Jungnang station in the urban and opposite at Bucheon station in the suburban area. For a station in natural state, the albedo was higher than urban stations because solar radiation reflects effectively. Relatively high temperatures were shown at stations located in urban area with low albedo and high emissivity, in general. However, temperature was high at Gajwa and Ttukseom stations, the albedo was relatively high due to the station environment surrounded by glass wall buildings and the Han river. In the station located in suburban area, both emissivity and temperature were low. Among these stations, Bucheon station had the highest emissivity values because the surface temperature was relatively lower than that of the suburban area. As a result, the albedo decreased and the emissivity increased at stations in urban areas. Additionally, Seoul metropolitan area had less than $100Wm^{-2}$ of net radiation, which implied that radiation energy could be absorbed in the atmosphere.

Assessment of Critical Temperature for the Growth and Development of Early Transplanted Temperate Rice

  • Wbonho Yang;Shingu Kang;Dae-Woo Lee;Jong-Seo Choi
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.171-171
    • /
    • 2022
  • Effect of temperature during the period of 10 days from transplanting (10 DFT) on the growth and development of rice plants was investigated by transplanting semi-adult seedlings six times from 5 April to 15 May at 10-day interval in the field conditions of 2020 and 2021, with aims to investigate the critical temperature for early transplanting of temperate rice. In the two experimental years, mean temperature for 10 DFT appeared 9.1, 10.5, 11.6, 13.8, 13.9, 16.2, 16.4, 16.7, 17.1, 17.8℃ depending on the transplanting date. Mean temperature of 9.1℃ and 10.5℃ for 10 DFT appeared in the April 5 and April 15 transplants in 2020 showed negative or no effect on the increase of rice growth and acceleration of heading date when compared to those of right after transplanting treatments in the same year. Mean temperature of 11.6℃ for 10 DFT appeared in the April 5 transplant in 2021 demonstrated greater biomass from early to heading stage but the same heading date compared to April 15 transplant, indicating that 11.6℃ for 10 DFT had a positive effect on rice growth but no effect on advanced heading. Both more biomass and advanced heading stage were observed when the mean temperature for 10 DFT was 13.8℃ or higher, compared to those of right after transplanting treatments. These findings indicate that effective 10-DFT mean temperature for rice growth exists between 10.5 and 11.6℃, and that for rice development in terms of heading stage lies between 11.6 and 13.8℃ in natural condition. Further field and indoor studies are suggested to narrow down the critical temperature for early transplanting of temperate rice, which will enable to maximize the crop period in high altitude regions with low temperature.

  • PDF

Surface Micro-Climate Analysis Based on Urban Morphological Characteristics: Temperature Deviation Estimation and Evaluation (도시의 지표형태학적 특성에 기반한 지면미기후 분석: 기온추정 및 평가)

  • Yi, Chaeyeon;An, Seung Man;Kim, KyuRang;Kwon, Hyuk-gi;Min, Jae-Sik
    • Atmosphere
    • /
    • v.26 no.3
    • /
    • pp.445-459
    • /
    • 2016
  • Air temperature deviation (ATD) is one of major indicators to represent spatial distribution of urban heat island (UHI), which is induced from the urbanization. The purpose of this study is to evaluate the accuracy of air temperature deviation about Climate Analysis Seoul (CAS) workbench, which had developed by National Institute Meteorological Science and TU Berlin. Comparison and correlation analysis for CAS ATD including meso-scale air temperature deviation, local-scale air temperature deviation, total air temperature deviation, surface heat flux deviation, cold air production deviation among meso-scale numerical modelling variable in 'Seoul Region', micro-scale numerical modelling in 'Detail Region', and CAS workbench variable using observation data in ground stations. Comparison between night time OBS ATD and CAS ATD show that have most close values. Most of observations ($dT_{max}$ and $dT_{min}$) have highly positive ($dT_{SHP}$, $dT_{CA}$, MD, TD, $f_{BS}$, $f_{US}$, $f_{WS}$, $h_B$) and negative ($f_{VS}$, $f_{TV}$, $h_V$, Z) correlations. However, CAS workbench needs further improvement of both observational framework and analytical framework to resolve the problems; (1) night time OBS ATD of has closer values in compare with at high rise mountain area and (2) correlations are very dependable to meteorological scale.

A Study on Exposure of Respiratory Hazard Factors in Food Service Workplace (국내 요식업 작업환경의 호흡기 유해인자 노출 연구)

  • Cha, Won-Seok;Kim, Eun-Young
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.75-86
    • /
    • 2020
  • Objectives: In this study, we assessed respiratory hazards in the working environment as the work-relatedness of occupational diseases were examined. Methods: The subjects of the study were three Korean meat roasting restaurants, one Chinese restaurant, and two cafeterias. Measurement items were total dust, respirable dust, fine dust (PM2.5), PAHs, TVOCs, temperature, humidity, carbon monoxide, carbon dioxide, and nitrogen dioxide. Results: The concentration of total dust and respiratory dust in the restaurant was low. Most PAHs were undetectable, but some Napthalene and Acenaphthylene was detected. Thirteen kinds of PAHs were detected in one sample of roasted meat, and Benzo(a)pyrene was 1.496 ㎍/㎥. PM2.5, TVOCs, CO, and CO2 were instantaneously high, but the average concentration was low. NO2 was not detected. Conclusions: The results show that harmful substances such as PM2.5, PAHs, CO, and TVOCs were generated in the air in the catering industry. When roasting meat, Benzo(a)pyrene, a carcinogen related to lung cancer, was generated among PAHs. Lung cancer can occur when working for a long time in such a working environment. Therefore, it is necessary to improve the working environment for the health of restaurant workers, and it is necessary to evaluate the concentration of harmful substances by cooking method through further research.

Prediction of Carbonation Progress for Concrete Structures Considering Change of Atmospheric Environment (대기환경변화를 고려한 콘크리트 구조물의 중성화 예측)

  • Lee, Chang-Soo;Yoon, In-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.574-584
    • /
    • 2003
  • The most common deterioration cause of concrete structures in urban environment is carbonation. Recently, the $CO_2$ concentration and temperature at atmosphere is sharply increased with time due to global warming phenomena. In this study, the climate scenario IS92a, which was suggested by the IPCC, is used to consider temperature and atmospheric $CO_2$ concentration change in the model of service life prediction. The modified mathematical solution, which was based on the Fick's 1st law of diffusion, was used to reflect concrete materials properties such as the degree of hydration of concrete with elapsed time, and important parameters, which associated with deterioration rate. The techniques of service life prediction are developed introducing the method of reliability and stochastic concept to consider microclimatic condition in Seoul, South Korea. From the result of service life prediction, concrete containing high W/C ratio is shown fast carbonation rate due to $CO_2$ concentration increase. It is concluded that the deterioration of concrete structures due to carbonation is insignificant problem on the conditions that below W/C 55%, well curing concrete.

A Study on Spatial and Physical Environment Satisfaction of Clinical Laboratory Scientists (진단검사의학과 검사실의 공간 환경만족도 조사 연구 - 근무자 중심으로 -)

  • Shim, Moon-Jung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.2
    • /
    • pp.111-117
    • /
    • 2005
  • The purpose of this study is to provide the basic guidelines of spatial and physical environment for the planning and design of clinical laboratory by analysing the extent of satisfaction of clinical laboratory scientists. The data for this analysis was gathered from March to May 2005 by the questionnaires of 208 clinical laboratory scientists who work in the 13 hospitals. All the collected data was analyzed by the SPSSWIN program. In this study, the satisfaction measurement tool was composed with 8 items and 5 score scale. The mean score of satisfaction for spatial and physical environment was 2.89 out of 5.0, "noise" was the lowest 2.40, "temperature and moisture of the lab." was 2.72, "lab. area, service area and administration area" was 2.77, "passageway space" was 2.94, circulation of workers was 2.94, "color of finish" was 3.19, "lighting of lab." was the highest 3.39. In conclusion, various factors, noise, temperature and moisture, clinical lab area, were evaluated to moderate dissatisfaction. Noise was especially the first serious problem in clinical lab. Considering the high growth of the number of tests, the planning of the clinical laboratory size should be considered not only to provide the optimal size but how it will correspond to the growth of the number of tests. Therefore the arrangement of each section need to be flexible in arrangement which is inevitable in expansion and reconstruction in the future.

  • PDF