• Title/Summary/Keyword: high resolution spectrum

Search Result 251, Processing Time 0.024 seconds

A Study on Estimation of Beat Frequency in a Water Level Measurement Radar (수위 측정 레이다에서의 비트 주파수 추정에 관한 연구)

  • Lee, Jonggil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1791-1797
    • /
    • 2014
  • A water level measurement radar estimates beat frequencies to extract the corresponding water level information for water resource management. Therefore, it is required to maintain the high degree of reliability and accuracy in beat frequency estimates. However, Beat spectra of water surface return echoes can have very widely varying shapes according to system frequency linearity, measurement environments and weather conditions. Therefore, serious problems may arise in maintaining the reliability and accuracy of the conventional level estimation method. Therefore, in this paper, high resolution spectrum estimates are analyzed for improvement of the conventional method. These methods show that the more accurate level measurement can be possible on the condition that SNR is higher than a certain required threshold. However, if SNR is too low, the conventional method shows that estimates are more reliable than the suggested method though absolute errors are too large.

On-line Magnetic Resonance Quality Evaluation Sensor

  • Kim, Seong-Min;McCarthy, Michael J.;Chen, Pictiaw;Zion, Boaz
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.314-324
    • /
    • 1996
  • A high speed NMR quality evaluation sensor was designed , constructed and tested . The device consists of an NMR spectrometer coupled to a conveyor system. The conveyor was run at speeds ranging from 0 to 250 mm/s. Spectral of avocado fruits and one-dimensional magnetic resonance images of pickled olives were acquired while the samples were moving on a conveyor belt mounted through a 20Tesla NMR magnet with a 20 mm diameter surface coil and a 150 mm diameter imaging coil respectively. Fro a magnetic resonance spectrum analysis, motion through variations in the magnetic field tends to narrow spectral line width just like using sample rotation in high resolution NMR to narrow spectral line width. Spectrum analysis was used to detect the dry weight of avocado fruits using the ratio oil and water resonance peaks. Good correlations maximum r=0.970@ 50 mm/s and minimum r=0.894@250mm/s ) between oil and water resonance peak ratio and dry weight of avocados were observed at speeds ra ging from0 to 250mm/s. For the application of magnetic resonance imaging (MRI) method, the projections were used to distinguish between pitted and non-pitted olives . Effect of fruit position in the coil was tested and coil degree effects were noticed when projects were generated under dynamic conditions. Various belt speeds (up to 250mm/s) were tested and detection results were compared to static measurements. Higher classification errors were occurred at dynamic conditions compared to errors while olives were at rest.

  • PDF

On-chip Power Supply Noise Measurement Circuit with 2.06mV/count Resolution (2.06mV/count의 해상도를 갖는 칩 내부 전원전압 잡음 측정회로)

  • Lee, Ho-Kyu;Jung, Sang-Don;Kim, Chul-Woo
    • Journal of IKEEE
    • /
    • v.13 no.4
    • /
    • pp.9-14
    • /
    • 2009
  • This paper describes measurement of an on-ship power supply noise in mixed-signal integrated circuits. To measure the on-chip power supply noise, we can check the effects of analog circuits and compensate it. This circuit consists of two independent measurement channels, each consisting of a sample and hold circuit and a frequency to digital converter which has a buffer and voltage controlled oscillator(VCO). The time-based voltage information and frequency-based power spectrum density(PSD) can be achieved by a simple analog to digital conversion scheme. The buffer works like a unit-gain buffer with a wide bandwidth and VCO has a high gain to improve resolution. This circuit was fabricated in a 0.18um CMOS technology and has 2.06mV/count. The noise measurement circuit consumes 15mW and occupies $0.768mm^2$.

  • PDF

High Resolution Cyclostationary Spectrum Sensing for ATSC Signal Detection (ATSC 신호 검출을 위한 고분해능 사이클로스테이션너리(Cyclostationary) 스펙트럼 센싱)

  • Yoo, Do-Sik;Lim, Jong-Tae;Kang, Min-Hong;Lim, Sun-Min
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.3
    • /
    • pp.378-384
    • /
    • 2009
  • In this paper, we consider a cyclostationary-feature-detection based spectrum sensing algorithm for ATSC signal detection. One of the proposed algorithms for IEEE 802.22 standardization organization which meet the requirements of IEEE 802.22 is Thomson's algorithm based on cyclostationary feature detection. We propose an interpolation-based spectrum sensing algorithm for ATSC signal detection, which has less computation complexity than that of Thomson's algorithm and provides no performance loss compared to Thomson's algorithm. By using zero-padding in time domain and effective sensing scanning method, the proposed algorithm requires less computational complexity and shows no performance degradation compared to Thomson's algorithm.

  • PDF

THE SWINGS EFFECTS OF THE A-X SYSTEM AND v''= 1-0 BAND OF CO

  • KIM SANG-JOON
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.2
    • /
    • pp.223-243
    • /
    • 1996
  • We have constructed a line-by-line model of the A-X system of CO in order to analyze the CO bands appearing in the UV spectra of comets. The model includes electronic, rotational, vibrational transitions, excitations by solar UV radiation, and effects of neutral and electron collisions. The major bands of the A-X system occur in the $1200 - 1800{\AA}$ range where the temporal variation of solar irradiation is significant. The solar spectrum in this spectral range shows many emission lines, which cause a significant Swings effect. We derived fluorescence efficiencies of the bands as functions of heliocentric velocity and cometocentric distance using a high resolution spectrum of the sun. We compared our model with a spectrum of comet P/Halley obtained with the IUE, and estimated that the UV Swings effects are less than 20 fluorescence efficiencies for the most bands of the A-X system. We discuss the temporal variation of solar UV irradiation and its effects on the fluorescence efficiencies. The study of the A-X system also requites knowledge of vibrational and rotational fluorescent processes in the infrared and radio regions because the majority of CO molecules in the coma is in the ground rotational states. The solar infrared spectrum near 5 microns, where the fundamental band of CO occurs, contains strong absorption lines of the fundamental band and hot bands of CO and its isotopes. We derived fluorescence efficiencies of the infrared band as functions of heliocentric velocity and cometrocentric distance. The solar absorption lines near 5 microns cause a 20 reduction of the g-factor of the fundamental band at heliocentric velocities close to 0 km/sec. We discuss the effects of neutral and electron collisions on the fluorescence efficiencies of the infrared and UV bands.

  • PDF

Performance Analysis of Collaborative Wideband Sensing Scheme based on Energy Detection with User Selection for Cognitive Radio (에너지검출 기반 협력 광대역 센싱에서 사용자 선택에 따른 센싱 성능 분석)

  • Lee, Mi-Sun;Kim, Yoon-Hyun;Kim, Jin-Young
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.2
    • /
    • pp.72-77
    • /
    • 2011
  • Spectrum sensing is a critical functionality of CR network; it allow secondary user to detect spectral holes and to opportunistically use under-utilized frequency bands without causing harmful interference to primary use. Recently, wideband service has been increase for processing abundance of data traffic. So CR network needs a realizable implementation design of spectrum sensing for wideband. To get high resolution performance of wideband sensing must precede algorithm processing for reliability signal detection. By the way, the performance of spectrum sensing can be degraded due to fading and shadowing. In order to overcome this problem, we propose system model of wideband sensing scheme on energy detected collaborative technique. we divide wideband into narrowbands and use narrowbands to detect signal excepting some narrowbands including bad channel through the CSI. And we simulate and analyze in terms of detection probability with various SNR.

Neutron and gamma-ray energy reconstruction for characterization of special nuclear material

  • Clarke, Shaun D.;Hamel, Michael C.;Di fulvio, Angela;Pozzi, Sara A.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.6
    • /
    • pp.1354-1357
    • /
    • 2017
  • Characterization of special nuclear material may be performed using energy spectroscopy of either the neutron or gamma-ray emissions from the sample. Gamma-ray spectroscopy can be performed relatively easily using high-resolution semiconductors such as high-purity germanium. Neutron spectroscopy, by contrast, is a complex inverse problem. Here, results are presented for $^{252}Cf$ and PuBe energy spectra unfolded using a single EJ309 organic scintillator; excellent agreement is observed with the reference spectra. Neutron energy spectroscopy is also possible using a two-plane detector array, whereby time-of-flight kinematics can be used. With this system, energy spectra can also be obtained as a function of position. Spatial-dependent energy spectra are presented for neutron and gamma-ray sources that are in excellent agreement with expectations.

Investigation of the Performance of Spectral Domain Optical Doppler Tomography with High-speed Line Scanning CMOS Camera and Its Application to the Blood Flow Measurement in a Micro-tube

  • Park, Cheol Woo;Lee, Changho;Lim, SooHee;Ni, Aleksey;An, Jin Hyo;Lee, Ho;Bae, Jae Sung;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.174-180
    • /
    • 2012
  • In this study, the feasibility of spectral domain optical Doppler tomography for measuring blood flow characteristics in a micro-tube was demonstrated through several experiments. The use of an SD-ODT system in blood flow measurement can provide high resolution images (5 microns resolution). We prepared three capillary tubes to reveal the effect of different concentrations of hematocrit ratio (HR). One tube serves as the control. The two other tubes contained different concentrations of HR (5%, 25%). Three different capillary tube inlet flow velocities were tested in the present study. The Reynolds number (Re) which is based on the capillary tube inner diameter ranges from Re=6 to 48. We calculated a Doppler shift of the power spectrum of the temporal interference fringes with Kasai autocorrelation function to achieve the velocity profile of the flow. As a result, SD-ODT systems could not detect the cell depletion layer in the present study due to the limitation of spatial resolution. Nevertheless, these systems were proven to be capable of observing the RBCs of blood.

Comparing Quantitative EEG and Low Resolution Electromagnetic Tomography Imaging between Deficit Syndrome and Non-Deficit Syndrome of Schizophrenia (정신분열병의 결핍증후군과 비결핍증후군에서 QEEG와 sLORETA를 이용한 비교연구)

  • Lee, Sang-Eun;Yim, Seon-Jin;Lee, Mi-Gyung;Lee, Jae-Won;Han, Kyu-Hee;Lee, Jong-Il;Sim, Min-Young;Yoon, Hai-Joo;Shin, Byoung-Hak
    • Sleep Medicine and Psychophysiology
    • /
    • v.17 no.2
    • /
    • pp.91-99
    • /
    • 2010
  • Objectives: Deficit schizophrenia (DS) constitutes a disease separate from non-deficit schizophrenia (NDS). The aim of the current study was to compare the quantitative EEG and low resolution electromagnetic tomography (LORETA) imaging between DS and NDS. Methods: This study was performed by 32 channels EEG for 42 schizophrenia patients who we categorized into DS and NDS using proxy instrument deficit syndrome (PDS). We performed the absolute power spectral analyses for delta, theta, alpha, low beta and high beta activities. We compared power spectrum between two groups using Independent t-test. Partial correlation test was performed with clinical parameters. Standardized LORETA (sLORETA) was used for comparison of cortical activity, and statistical nonparametric mapping (SnPM) was applied for the statistical analysis. Results: DS showed significantly increased delta and theta absolute power in fontal and parietal region compared with NDS (p<0.05). Power spectrum showed significant correlation with 'anergia' and 'hostility/suspiciousness' subscale of brief psychiatric rating scale (BPRS)(p<0.05). sLORETA found out the source region (anterior cingulate cortex/limbic part) that delta activity was significantly increased in DS (p=0.042). Conclusions: DS showed different cortical activity compared with NDS. Our results may suggest QEEG and LORETA could be the marker in differentiating between DS and NDS.

  • PDF

Endoscopic Ultrasound Staging of Upper Gastrointestinal Malignancies

  • Saadany, Sherif El;Mayah, Wael;Kalla, Ferial El;Atta, Tawfik
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2361-2367
    • /
    • 2016
  • Since 1980, endoscopic ultrasound (EUS) has been used as an important tool for the evaluation of malignant diseases in hollow viscus and bilio-pancreas, as well as sub-epithelial tumors. The high-resolution capacity and low penetration depth of EUS make it possible to obtain highly detailed images of the gastrointestinal wall and immediate surroundings to a depth of 4-5 cm. Thus, over the past 35 years, EUS succeeded to modify management in significant number of cases and is now considered a gold standard tool for many gastrointestinal diseases, especially in the pancreatico-biliary tract, and adjuvant needle insertion now allows access to remote lesions that were difficult to reach in the past. With the growing spectrum of indications, tissue sampling for diagnostic purposes has become common. In this review, we aim to highlight the expanding spectrum of EUS indications and uses in staging of upper gastrointestinal malignancies, especially esophageal, gastric and ampullary tumors.