• 제목/요약/키워드: high pressure air inlet velocity

검색결과 25건 처리시간 0.031초

생활폐기물 자동집하시설 이송관망 성능평가 (Performance Evaluation on the Pipelines for an Automated Vacuum Waste Collection System)

  • 장춘만;이상문
    • 한국유체기계학회 논문집
    • /
    • 제18권5호
    • /
    • pp.26-32
    • /
    • 2015
  • This paper describes performance evaluation of design parameters, air velocity inside a pipeline and pressure along a pipeline, using experimental measurements in an automated vacuum waste collection system. Automatic robot having six cameras is introduced to analyze the internal pipeline conditions whether waste accumulates at the bottom of the pipeline or not. Throughout the experimental measurements of the pipeline having the various shapes, it is found that pressure and internal air velocity linearly increase along the pipeline from a waste inlet to a waste collection station while air density decreases due to the air compression effect with high pressure. Although air velocity inside the pipeline at a waste inlet keeps design velocity range between 20 m/s and 30 m/s, it is noted that air velocity near the waste collection station exceeds maximum design velocity of 30 m/s. Pressure increase per unit length is changed from 17.6 Pa/m to 18.9 Pa/m, which depends on the air velocity inside the pipeline. From the investigation inside the pipeline with CCTV loaded on an automated robot, waste accumulated at the bottom of the pipeline is mainly found at the downstream of a circular curved pipe, an inclined pipe and a bended pipe.

MILD 이용한 배기가스 재순환에 관한 연구 (A study on the exhaust gas recirculation in a MILD combustion furnace by using a Venturi nozzle)

  • 하지수;심성훈
    • 에너지공학
    • /
    • 제22권4호
    • /
    • pp.413-419
    • /
    • 2013
  • 본 연구에서는 동심원관 형태의 MILD 연소로에서 바깥 원통의 배기가스 통로에서부터 안쪽 원통의 연소통로 사이에 연결관을 설치하고 배기가스를 유입하기 위해 벤츄리 노즐을 사용할 경우 벤츄리 노즐의 기하학적 형상 변화와 고압공기 노즐의 유속 변화에 따라 고압공기 유량, 배기가스 유입량 특성을 수치해석을 통해 살펴봄으로써 최적의 벤츄리 노즐 형상과 고압공기 유속 조건들을 도출하는 것을 본 연구의 목적으로 하였다. 본 연구의 전산 해석을 통해 고압공기 노즐 출구가 연소로 벽면에 부착된 경우와 배기가스에 노출된 경우를 비교하였고, 이 두 가지 형상에 대하여 고압공기 노즐과 벤츄리 노즐의 간격을 고압공기 노즐 직경의 1배에서 3배로 변화할 때의 유입량 특성을 살펴보았다. 또한 고압공기 노즐에서의 출구 유속을 변화하여 유입량 특성을 살펴보았다. 이를 통해 고압공기 노즐과 벤츄리 노즐의 간격이 증가하면 고압공기 노즐이 벽면에 부착된 경우는 유입량이 상대적으로 변화가 적으나 배기가스에 노출된 경우는 유입량이 증가하는 경향을 확인하였다. 또한 고압공기 노즐의 유속이 증가하면 속도가 낮은 범위에서는 유입량비가 상대적으로 증가하는 경향이 크지만 속도가 큰 영역에서는 증가하는 경향이 줄어드는 것을 확인하였다.

Experimental Study of Moisture-Wicking Fabric as Cooling Pad for Novel Rotary Direct Evaporative Cooler

  • Sang-Hwan Park;Jae-Weon Jeong
    • 국제초고층학회논문집
    • /
    • 제12권4호
    • /
    • pp.335-341
    • /
    • 2023
  • This study proposes a novel rotary direct evaporative cooler and investigates the potential of a moisture-wicking fabric as a cooling pad for the proposed evaporative cooler. The rotary direct evaporative cooler rotates the cooling pad to reduce the water and energy consumption of the pump compared to those of existing direct evaporative coolers. A moisture-wicking fabric is considered as the material of the cooling pad, because of its high moisture-wicking property, enhancing water evaporation. Experiments are performed under various inlet air conditions while measuring the air temperature, relative humidity, air velocity, and differential pressure. The evaporative cooling efficiency and impacts of the inlet air temperature and air velocity on the cooling performance are also evaluated. The results demonstrate the potential of the moisture-wicking fabric as cooling pad of direct evaporative cooler.

충격기류식 여과집진장치에서 운전조건 변화로 인한 여과저항에 관한 연구[I] (Study on Filter Drag Due to the Change of Operation Conditions in a Pulse Air Jet-type Bag Filter[I])

  • 류재용;서정민;박정호;전보경;최금찬;손영일
    • 한국환경과학회지
    • /
    • 제16권4호
    • /
    • pp.449-458
    • /
    • 2007
  • Research results for the pressure drop variance depending on operation conditions such as change of inlet concentration, pulse interval, and face velocity, etc., in a pulse air jet-type bag filter show that while at $3kg/cm^2$ whose pulse pressure is low, it is good to make an pulse interval longer in order to form the first layer, it may not be applicable to industry because of a rapid increase in pressure. In addition, the change of inlet concentration contributes more to the increase of pressure drop than the pulse interval does. In order to reduce operation costs by minimizing filter drag of a filter bag at pulse pressure $5kg/cm^2$, the dust concentration should be minimized, and when the inlet dust loading is a lower concentration, the pulse interval in the operation should be less than 70 sec, but when inlet dust loading is a higher concentration, the pulse interval should be below 30 sec. In particular, in the case that inlet dust loading is a higher concentration, a high-pressure distribution is observed regardless of pulse pressure. This is because dust is accumulated continuously in the filter bag and makes it thicker as filtration time increases, and thus the pulse interval should be set to below 30 sec. If the equipment is operated at 1m/min of face velocity, while pressure drop is low, the bag filter becomes larger and thus, its economics are very low due to a large initial investment. Therefore, a face velocity of around 1.5 m/min is considered to be the optimal operation condition. At 1.5 m/min considered to be the most economical face velocity, if the pulse interval increases, since the amount of variation in filter drag is large, depending on the amount of inlet dust loading, the operation may be possible at a lower concentration when the pulse interval is 70 sec. However, for a higher concentration, either face velocity or pulse interval should be reduced.

태양열을 이용한 공기가열 집열기의 부력효과 해석 연구 (Study on Analysis of Buoyancy Effect in Air-heating Collector using Solar Heat)

  • 양영준
    • 한국산업융합학회 논문집
    • /
    • 제24권4_2호
    • /
    • pp.467-474
    • /
    • 2021
  • The renewable energy is known as eco-friendly energy to reduce the use of fossil fuel and decrease the environmental pollution due to exhaust gas. Targets of solar collector in domestic are usually acquisitions of hot water and hot air. System of air-heating collector is one of the technologies for obtaining hot air in cases of especially heating room and drying agricultural product. The purpose of this study is to investigate the characteristics of thermal flow such as relative pressure, velocity, outlet temperature and buoyancy effect in air-heating collector using solar heat. The flow field of air-heating collector was simulated using ANSYS-CFX program and the behaviour of hot air was evaluated with SST turbulence model. As the results, The streamline in air-heating collector showed several circular shapes in case of condition of buoyancy. Temperature difference in cross section of outlet of air-heating collector did not almost show in cases of buoyancy and small inlet velocity. Furthermore merit of air-heating collector was not observed in cases of inlet velocities. Even though it was useful to select condition of buoyancy for obtaining high temperature, however, it was confirmed that the trade off between high temperature of room and rapid injection of hot air to room could be needed through this numerical analysis.

장력 감김으로 부착된 가로방향 휜-미니채널의 공기측 열전달 특성 (Air Side Heat Transfer Charactieristics of Tension Wound Transverse Fin with Minichannel)

  • 김종수;임용빈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.701-706
    • /
    • 2005
  • Pipes, tubes. and tubular sections with external transverse high fins have been used extensively for heating cooling, and degumidifying air and other gases. This work was performed to investigate an air side heat transfer charactieristics of minichannel with tension wound transverse fin. This estimate was confirmed conversion heat capacity the air side surface area enlargement and heat transfer charactieristics performed available inlet tube side hot water mass flux or outlet tube side air frontal air velocity. The most suitable tension wound transverse finned minichannel was measured extremely low in air side pressure drop and fin effectiveness $3.3\~4.4$. The pressure drop $0.9\~2.8Pa$ was ranged frontal air velocity $0.5\~1.2m/s$. It is also appeared that heat transfer in air side could be better conversion heat area which has been increased $330\%$ of heat capacity compared with the bare tube.

충격기류식 여과집진장치의 운전조건 변화에 따른 적정 탈진주기 및 탈진압력 설정 (Prediction of Pulse Pressure and Pulse Interval of Change in Operation Conditions of a Pulse Air Jet Bag Filter)

  • 이덕기;임우택;조재환;최금찬;신현무;장성호;서정민
    • 한국환경과학회지
    • /
    • 제27권6호
    • /
    • pp.349-358
    • /
    • 2018
  • In this study, using coke dust from ironwork, the pulse pressure on a pulse air jet bag filter was investigated considering the influence of the pressure loss due to filtration velocity and pressure intervals. The research on the optimal pulse pressure prediction of a pulse air jet type bag filter using coke dust showed the following results. Pressure loss volatility produced by the pulse pressure under low dust concentration(0.5, $1g/m^3$) and low face velocity(1.25 m/min) was less than $10mmH_2O$. This suggests that the pulse pressure has a low impact on the pressure loss. In contrast, pressure loss volatility under high dust concentration($3g/m^3$) and high face velocity(1.75 m/min) was $25mmH_2O$. Therefore, pulse pressure with high dust concentration and high face velocity has a strong influence on the pressure loss volatility, compared to the condition of low dust concentration and low face velocity. The optimal pulse pressure of inlet dust concentration($0.5g/m^3$) was $6kg/cm^2$ under the same face velocity(1.75 m/min). As concentration increased from 1 to $2g/m^3$, the pulse pressure gradually reached $5kg/cm^2$ thus indicating that the pulse pressure($5kg/cm^2$) is pertinent at a high concentration($3g/m^3$). The pulse intervals: 20, 25 and 30 sec, which are relatively longer than 10 and 15 sec, corresponded to high pressure loss volatility produced by the pulse pressure. Furthermore, low pressure loss volatility was noted at $5kg/cm^2$ of the overall pulse pressure.

충격기류식 여과집진장치에서 압력손실에 영향을 주는 인자의 효율예측 (Prediction of the Efficiency of Factors Affecting Pressure Drop in a Pulse Air Jet-type Bag Filter)

  • 서정민;류재용;임우택;정문섭;박정호;신춘환
    • 한국환경과학회지
    • /
    • 제19권4호
    • /
    • pp.437-446
    • /
    • 2010
  • The pressure drop through pulse air jet-type bag filter is one of the most important factors on the operating cost of bagfilter houses. In this study, the pilot-scale pulse air jet-type bag filter with about 6 m2 filtration area was designed and tested for investigating the effects of the four operating conditions on the total pressure drop, using the coke dust collected from a steel mill factory. When the face velocity is higher than 2 m/min, it is not applicable to on-spot due to the increase of power expenses resulting from a high-pressure drop, and thus, 1.5 m/min is considered to be reasonable. The regression analysis results show that the degree of effects of independent parameters is a order of face velocity > concentration > time > pressure. The results of SPSS answer tree analysis also reveal that the operation time affects the pressure drop greatly in case of 1 m/min of face velocity, while the inlet concentration affects the pressure drop in case of face velocity more than 1.5 m/min.

다공성 세라믹 Biofilter를 이용한 Toluene 가스 제거 (Removal of Toluene Vapor by Porous Ceramic Biofilter)

  • 임재신;구자공;박상진
    • 한국대기환경학회지
    • /
    • 제14권6호
    • /
    • pp.599-606
    • /
    • 1998
  • Removal of toluene vapor from airstreams was studied in a biological reactor known as a biofilter. The biofilter was packed porous ceramic inoculated with thickened activated sludge (MLVSS 17,683 mg/L). The lab-scale biofilter was operated for 42 days under various experimental conditions including inlet toluene concentrations and flow rates of the contaminated air streams. Removal efficiency reached up 96.6% after 4 days from start up. Nutrient limitation was proposed as a reason for the decrease in biofilter performence. Biofilter performance decreased substantially, coincident with the buildup of back pressure due to accumulation of excess VSS within the medium bed. Practically, the bed needs to be backwashed when the overall pressure drop is greater than 460.6 Pa at SV (Space Velocity) 100 h-1. Periodic backwashing of the biofilter was necessary for removing excess biomass and attaining stable long -term high removal efficiency The removal efficiency of toluene in the biofilter decreased as the gas velocity and toluene concentration in the inlet gas increased. The maximum elimination capacity of ceramic biofilter could reach up to 444.85 g/m3. hr. When the loading of toluene exceed this critical value, substrate inhibition occurred.

  • PDF

$CO_2$용 마이크로채널 가스쿨러의 운전조건 변화에 따른 성능특성에 관한 해석적 연구 (Simulation Study on the Performance Characteristics of $CO_2$ microchannel gascooler with Operation Conditions)

  • 신은성;배경진;김병철;조홍현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1090-1095
    • /
    • 2009
  • The purpose of this study is to determine the performance characteristics for the micro-channel gascooler with various operating conditions. The performance of four kind of HX models were analyzed and optimized with the variation of refrigerant inlet temperature, air velocity, outdoor temperature. As a result, Model B showed the maximum capacity and high performance could be maintained for wide operating conditions. Beside, the micro-channel heat exchanger could be appled to $CO_2$ system appropriately because of a small pressure drop and high heat transfer rate.

  • PDF