• Title/Summary/Keyword: high pressure air inlet velocity

Search Result 25, Processing Time 0.027 seconds

Performance Evaluation on the Pipelines for an Automated Vacuum Waste Collection System (생활폐기물 자동집하시설 이송관망 성능평가)

  • Jang, Choon-Man;Lee, Sang-Moon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.5
    • /
    • pp.26-32
    • /
    • 2015
  • This paper describes performance evaluation of design parameters, air velocity inside a pipeline and pressure along a pipeline, using experimental measurements in an automated vacuum waste collection system. Automatic robot having six cameras is introduced to analyze the internal pipeline conditions whether waste accumulates at the bottom of the pipeline or not. Throughout the experimental measurements of the pipeline having the various shapes, it is found that pressure and internal air velocity linearly increase along the pipeline from a waste inlet to a waste collection station while air density decreases due to the air compression effect with high pressure. Although air velocity inside the pipeline at a waste inlet keeps design velocity range between 20 m/s and 30 m/s, it is noted that air velocity near the waste collection station exceeds maximum design velocity of 30 m/s. Pressure increase per unit length is changed from 17.6 Pa/m to 18.9 Pa/m, which depends on the air velocity inside the pipeline. From the investigation inside the pipeline with CCTV loaded on an automated robot, waste accumulated at the bottom of the pipeline is mainly found at the downstream of a circular curved pipe, an inclined pipe and a bended pipe.

A study on the exhaust gas recirculation in a MILD combustion furnace by using a Venturi nozzle (MILD 이용한 배기가스 재순환에 관한 연구)

  • Ha, Ji Soo;Shim, Sung Hoon
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.413-419
    • /
    • 2013
  • The present study used the MILD combustor, which has coaxial cylindrical tube. The outside tube of the MILD combustor corresponds to the exhaust gas passage and the inner side tube is the furnace passage. A numerical analysis was accomplished to elucidate the characteristics of exhaust gas entrainment toward the inner furnace with the changes of venturi nozzle geometrical parameters, nozzle position, nozzle gap between high pressure air nozzle and venturi nozzle, and with the change of high pressure nozzle inlet velocity. The entrainment flow rate for the case with the high pressure air nozzle attached at the exhaust gas wall has relatively small change with the change of nozzle gap. That for the case with the high pressure air nozzle exposed to the exhaust gas has monotonically increase with the change of nozzle gap. The flow rate ratio of entrainment flow rate has considerably increase tendency with relatively lower air inlet velocity, on the other hand, that with relatively higher air inlet velocity could be seen relatively small increase.

Experimental Study of Moisture-Wicking Fabric as Cooling Pad for Novel Rotary Direct Evaporative Cooler

  • Sang-Hwan Park;Jae-Weon Jeong
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.4
    • /
    • pp.335-341
    • /
    • 2023
  • This study proposes a novel rotary direct evaporative cooler and investigates the potential of a moisture-wicking fabric as a cooling pad for the proposed evaporative cooler. The rotary direct evaporative cooler rotates the cooling pad to reduce the water and energy consumption of the pump compared to those of existing direct evaporative coolers. A moisture-wicking fabric is considered as the material of the cooling pad, because of its high moisture-wicking property, enhancing water evaporation. Experiments are performed under various inlet air conditions while measuring the air temperature, relative humidity, air velocity, and differential pressure. The evaporative cooling efficiency and impacts of the inlet air temperature and air velocity on the cooling performance are also evaluated. The results demonstrate the potential of the moisture-wicking fabric as cooling pad of direct evaporative cooler.

Study on Filter Drag Due to the Change of Operation Conditions in a Pulse Air Jet-type Bag Filter[I] (충격기류식 여과집진장치에서 운전조건 변화로 인한 여과저항에 관한 연구[I])

  • Ryu, Jae-Yong;Suh, Jeong-Min;Park, Jeong-Ho;Jeon, Bo-Kyung;Choi, Kum-Chan;Son, Yoyng-Il
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.449-458
    • /
    • 2007
  • Research results for the pressure drop variance depending on operation conditions such as change of inlet concentration, pulse interval, and face velocity, etc., in a pulse air jet-type bag filter show that while at $3kg/cm^2$ whose pulse pressure is low, it is good to make an pulse interval longer in order to form the first layer, it may not be applicable to industry because of a rapid increase in pressure. In addition, the change of inlet concentration contributes more to the increase of pressure drop than the pulse interval does. In order to reduce operation costs by minimizing filter drag of a filter bag at pulse pressure $5kg/cm^2$, the dust concentration should be minimized, and when the inlet dust loading is a lower concentration, the pulse interval in the operation should be less than 70 sec, but when inlet dust loading is a higher concentration, the pulse interval should be below 30 sec. In particular, in the case that inlet dust loading is a higher concentration, a high-pressure distribution is observed regardless of pulse pressure. This is because dust is accumulated continuously in the filter bag and makes it thicker as filtration time increases, and thus the pulse interval should be set to below 30 sec. If the equipment is operated at 1m/min of face velocity, while pressure drop is low, the bag filter becomes larger and thus, its economics are very low due to a large initial investment. Therefore, a face velocity of around 1.5 m/min is considered to be the optimal operation condition. At 1.5 m/min considered to be the most economical face velocity, if the pulse interval increases, since the amount of variation in filter drag is large, depending on the amount of inlet dust loading, the operation may be possible at a lower concentration when the pulse interval is 70 sec. However, for a higher concentration, either face velocity or pulse interval should be reduced.

Study on Analysis of Buoyancy Effect in Air-heating Collector using Solar Heat (태양열을 이용한 공기가열 집열기의 부력효과 해석 연구)

  • Yang, Young-Joon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.4_2
    • /
    • pp.467-474
    • /
    • 2021
  • The renewable energy is known as eco-friendly energy to reduce the use of fossil fuel and decrease the environmental pollution due to exhaust gas. Targets of solar collector in domestic are usually acquisitions of hot water and hot air. System of air-heating collector is one of the technologies for obtaining hot air in cases of especially heating room and drying agricultural product. The purpose of this study is to investigate the characteristics of thermal flow such as relative pressure, velocity, outlet temperature and buoyancy effect in air-heating collector using solar heat. The flow field of air-heating collector was simulated using ANSYS-CFX program and the behaviour of hot air was evaluated with SST turbulence model. As the results, The streamline in air-heating collector showed several circular shapes in case of condition of buoyancy. Temperature difference in cross section of outlet of air-heating collector did not almost show in cases of buoyancy and small inlet velocity. Furthermore merit of air-heating collector was not observed in cases of inlet velocities. Even though it was useful to select condition of buoyancy for obtaining high temperature, however, it was confirmed that the trade off between high temperature of room and rapid injection of hot air to room could be needed through this numerical analysis.

Air Side Heat Transfer Charactieristics of Tension Wound Transverse Fin with Minichannel (장력 감김으로 부착된 가로방향 휜-미니채널의 공기측 열전달 특성)

  • Kim Jong-Soo;Im Yong-Bin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.701-706
    • /
    • 2005
  • Pipes, tubes. and tubular sections with external transverse high fins have been used extensively for heating cooling, and degumidifying air and other gases. This work was performed to investigate an air side heat transfer charactieristics of minichannel with tension wound transverse fin. This estimate was confirmed conversion heat capacity the air side surface area enlargement and heat transfer charactieristics performed available inlet tube side hot water mass flux or outlet tube side air frontal air velocity. The most suitable tension wound transverse finned minichannel was measured extremely low in air side pressure drop and fin effectiveness $3.3\~4.4$. The pressure drop $0.9\~2.8Pa$ was ranged frontal air velocity $0.5\~1.2m/s$. It is also appeared that heat transfer in air side could be better conversion heat area which has been increased $330\%$ of heat capacity compared with the bare tube.

Prediction of Pulse Pressure and Pulse Interval of Change in Operation Conditions of a Pulse Air Jet Bag Filter (충격기류식 여과집진장치의 운전조건 변화에 따른 적정 탈진주기 및 탈진압력 설정)

  • Lee, Deok-Gi;Lim, Woo-Taik;Cho, Jae-Hwan;Choi, Kum-Chan;Shin, Hyun-Moo;Jang, Seong-Ho;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.27 no.6
    • /
    • pp.349-358
    • /
    • 2018
  • In this study, using coke dust from ironwork, the pulse pressure on a pulse air jet bag filter was investigated considering the influence of the pressure loss due to filtration velocity and pressure intervals. The research on the optimal pulse pressure prediction of a pulse air jet type bag filter using coke dust showed the following results. Pressure loss volatility produced by the pulse pressure under low dust concentration(0.5, $1g/m^3$) and low face velocity(1.25 m/min) was less than $10mmH_2O$. This suggests that the pulse pressure has a low impact on the pressure loss. In contrast, pressure loss volatility under high dust concentration($3g/m^3$) and high face velocity(1.75 m/min) was $25mmH_2O$. Therefore, pulse pressure with high dust concentration and high face velocity has a strong influence on the pressure loss volatility, compared to the condition of low dust concentration and low face velocity. The optimal pulse pressure of inlet dust concentration($0.5g/m^3$) was $6kg/cm^2$ under the same face velocity(1.75 m/min). As concentration increased from 1 to $2g/m^3$, the pulse pressure gradually reached $5kg/cm^2$ thus indicating that the pulse pressure($5kg/cm^2$) is pertinent at a high concentration($3g/m^3$). The pulse intervals: 20, 25 and 30 sec, which are relatively longer than 10 and 15 sec, corresponded to high pressure loss volatility produced by the pulse pressure. Furthermore, low pressure loss volatility was noted at $5kg/cm^2$ of the overall pulse pressure.

Prediction of the Efficiency of Factors Affecting Pressure Drop in a Pulse Air Jet-type Bag Filter (충격기류식 여과집진장치에서 압력손실에 영향을 주는 인자의 효율예측)

  • Suh, Jeong-Min;Ryu, Jae-Yong;Lim, Woo-Taik;Jung, Moon-Sub;Park, Jeong-Ho;Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.437-446
    • /
    • 2010
  • The pressure drop through pulse air jet-type bag filter is one of the most important factors on the operating cost of bagfilter houses. In this study, the pilot-scale pulse air jet-type bag filter with about 6 m2 filtration area was designed and tested for investigating the effects of the four operating conditions on the total pressure drop, using the coke dust collected from a steel mill factory. When the face velocity is higher than 2 m/min, it is not applicable to on-spot due to the increase of power expenses resulting from a high-pressure drop, and thus, 1.5 m/min is considered to be reasonable. The regression analysis results show that the degree of effects of independent parameters is a order of face velocity > concentration > time > pressure. The results of SPSS answer tree analysis also reveal that the operation time affects the pressure drop greatly in case of 1 m/min of face velocity, while the inlet concentration affects the pressure drop in case of face velocity more than 1.5 m/min.

Removal of Toluene Vapor by Porous Ceramic Biofilter (다공성 세라믹 Biofilter를 이용한 Toluene 가스 제거)

  • Im, Jae-Sin;Gu, Ja-Gong;Park, Sang-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.6
    • /
    • pp.599-606
    • /
    • 1998
  • Removal of toluene vapor from airstreams was studied in a biological reactor known as a biofilter. The biofilter was packed porous ceramic inoculated with thickened activated sludge (MLVSS 17,683 mg/L). The lab-scale biofilter was operated for 42 days under various experimental conditions including inlet toluene concentrations and flow rates of the contaminated air streams. Removal efficiency reached up 96.6% after 4 days from start up. Nutrient limitation was proposed as a reason for the decrease in biofilter performence. Biofilter performance decreased substantially, coincident with the buildup of back pressure due to accumulation of excess VSS within the medium bed. Practically, the bed needs to be backwashed when the overall pressure drop is greater than 460.6 Pa at SV (Space Velocity) 100 h-1. Periodic backwashing of the biofilter was necessary for removing excess biomass and attaining stable long -term high removal efficiency The removal efficiency of toluene in the biofilter decreased as the gas velocity and toluene concentration in the inlet gas increased. The maximum elimination capacity of ceramic biofilter could reach up to 444.85 g/m3. hr. When the loading of toluene exceed this critical value, substrate inhibition occurred.

  • PDF

Simulation Study on the Performance Characteristics of $CO_2$ microchannel gascooler with Operation Conditions ($CO_2$용 마이크로채널 가스쿨러의 운전조건 변화에 따른 성능특성에 관한 해석적 연구)

  • Shin, Eun-Sung;Bae, Kyung-Jin;Kim, Byeong-Cheol;Cho, Hong-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1090-1095
    • /
    • 2009
  • The purpose of this study is to determine the performance characteristics for the micro-channel gascooler with various operating conditions. The performance of four kind of HX models were analyzed and optimized with the variation of refrigerant inlet temperature, air velocity, outdoor temperature. As a result, Model B showed the maximum capacity and high performance could be maintained for wide operating conditions. Beside, the micro-channel heat exchanger could be appled to $CO_2$ system appropriately because of a small pressure drop and high heat transfer rate.

  • PDF