• 제목/요약/키워드: high power factor

검색결과 1,902건 처리시간 0.072초

단일전력단 고역률 AC/DC Two-Switch Forward 컨버터 (Single-Stage High Power Factor AC/DC Two-Switch Forward Converter)

  • 배진용;김용;권순도;이규훈;계상범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.169-172
    • /
    • 2006
  • This paper presents the single-stage High Power Factor AC/DC Two-Switch Forward Converter (TSFC). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contents of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output. The principle of operation, feature and design considerations are illustrated and verified through the simulation with a 200W(5V, 40A) 200kHz MOSFET based experimental circuit.

  • PDF

단일 스위치 3상 ZCS 강압형 정류기의 펄스 주파수 제어 (A Pulse Frequency Control of Single-switch Three-phase ZCS Buck Rectifiers)

  • 송중호;김용덕;이동윤;최익;최주엽;유지윤
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.82-90
    • /
    • 1999
  • 본 논문은 단일 스위치 3상 ZCS 강압형 정류기의 펄스주파수 제어기법을 다루고 있다. 제안하는 펄스주파수 제어방법은 거의 정현적인 입력전류를 흐르게 하여 3상 강압형 정류기의 성능을 보여준다. 제안하는 제어구조의 유용성을 검증해 주는 시뮬레이션과 실험 결과는 단일 스위치 3상 ZCS 강압형 정류기의 고역율, 입력전류의 낮은 THD, 부하 변동에 대한 전압의 응답특성들이 뛰어남을 보여준다.

영전류 스위칭 방식의 직렬 공진형 AC/DC 컨버터를 위한 전환모드 이산 슬라이딩 제어 (Switched discrete sliding mode control for ZCS series rosonant AC to DC converter)

  • 문건우;이정훈;이대식;윤명중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.1219-1226
    • /
    • 1993
  • A buck-boost zero current switched(ZCS) series resonant AC to DC converter for the DC output voltage regulation together with high power factor is proposed. The proposed single phase AC to DC converter enables a zero current switching operation of all the power devices allowing the circuit to operate at high swtiching frequencies and high power levels. A dynamic model for this Ac to DC converter is developed and an analysis for the internal operational characteristics is explored. Based on this analysis, a switched discrete sliding mode control(SDSMC) technique is investigated and its advantages over the other types of current control techniques are discussed. With the proposed control technique, the unity power factor without a current overshoot and a wide range of output voltage can be obtained.

  • PDF

Soft Switching Bridgeless PFC Buck Converters

  • Emrani, Amin;Mahdavi, Mohammad;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • 제12권2호
    • /
    • pp.268-275
    • /
    • 2012
  • Based on the standards that limit the harmonic pollution of electronic systems, the use of PFC converters is mandatory. In this paper, a new resonant bridgeless PFC converter is introduced. By eliminating the input bridge diodes, the efficiency is improved. Moreover, soft switching conditions for all of the semiconductor elements are achieved without adding any extra switches. As a result, high efficiency is attained. The proposed converter is analyzed and the theoretical and simulation results of the proposed converter are presented. In order to verify the validity of the analysis, a 40 w prototype converter is implemented and experimental results are presented. The experimental results show that high efficiency is attained while achieving a high power factor.

고압전동기 고정자 권선 절연재료에서 유전정접 특성 (Characteristics of Dissipation Factor in High Voltage Motor Stator Insulations)

  • 모일순;김희동;이영준;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2101-2103
    • /
    • 1999
  • The insulation condition of stator windings was measured by dissipation factor($tan{\delta}$) test in the six high voltage motors(rated 6.6kV) which had been in service for two years. The ${\Delta}tan{\delta}$ of motor D and E was higher than that of the rest motors. The specimens were drawn out from stator windings of the high voltage motor and their were analyzed using scanning electron microscope (SEM). SEM result shows that large voids are present in the interface both turn insulation and groundwall insulation.

  • PDF

경제성을 고려한 보조전원장치의 컨버터 입력전압 추정을 위한 제어기 설계 (A Controller Design for SIV with Converter Derived Input Voltage for Consideration Economic Efficiency)

  • 김재문;안정준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1131-1136
    • /
    • 2008
  • The single-phase PWM converter employing power semiconductors is currently applied to the power unit of high-speed rail vehicle and increasingly used as the front-end converter with properties of near unity power factor. Power factor and harmonics are increasingly important needs for drive system of high-speed rail vehicle. The proposed approach has many advantages which include fewer semiconductor components, simplified control, high performance features and satisfies IEC 555 harmonic current standards. Simulation results show that the dc-link voltage control obey the reference value during constant load and input current is near sinusoidal.

  • PDF

단일전력단 고역률 TTFC(Two-Transistor Forward Converter) (Single-Stage High Power Factor TTFC(Two-Transistor Forward Converter))

  • 배진용;김용;김필수;이은영;권순도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.226-228
    • /
    • 2005
  • This paper presents the single-stage High Power Factor TTFC(Two-Transistor Forward Converter). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contests of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output.

  • PDF

Measurement of Peak-to-Average Power Ratio for HRIT

  • Park Durk-Jong;Yang Hyung-Mo;Ahn Sang-Il
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.498-500
    • /
    • 2004
  • QPSK (Quaternary Phase Shift Keying) will be adopted as the modulation of HRIT (High Rate Information Transmission) which is transmitted to COMS (Communication, Ocean and Meteorological Satellite) through HPA (High Power Amplifier) in ground segment. Due to the nonlinearity of HPA, IMD (Inter-Modulation Distortion) of multi-carrier signals and PAPR (Peak-to-Average Power Ratio) of modulated HRIT must be considered to estimate the output power of HPA. In this paper, we measured the PAPR to various the roll-off factor of RRC (Root Raised Cosine filter) which is filtering the modulated HRIT signal for reducing ISI (Inter-Symbol Interference) and bandwidth. It was found that the minimum PAPR is 2.78dB at 0.5 of roll-off factor for scrambled data. It's 2.78dB of P APR will be in output power selecting in COMS earth station.

  • PDF

A Simple ZVT PWM Single-Phase Rectifier with Reduced Conduction Loss and Unity Power Factor

  • Kim, In-Dong;Choi, Seong-Hun;Nho, Eui-Cheol;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.55-63
    • /
    • 2007
  • This paper proposes a simple unity power factor zero-voltage-transition (ZVT) pulse-width-modulated (PWM) single-phase rectifier, which features reduced switching and conduction losses. The switching loss reduction is achieved by a simple auxiliary commutation circuit, and the conduction loss reduction is achieved by employing a single-stage converter, rather than a typical double-stage converter comprising of a front-end rectifier and a boost rectifier. Furthermore, thanks to good features such as a simple PWM control at constant frequency, low switch stress, low Var rating of commutation circuits, and simple power circuit structure, it is suitable for high power applications. The principles of operation are explained in detail, and a major characteristics analysis and the experimental results of the new converter are also included in this paper.

싸이리스터 정류부하를 위한 새로운 저원가 복합형 전력필터 (A New Low Cost Hybrid Power Filter for Thyristor-Controlled Rectifier Load)

  • 한성룡;김수근;석원엽;조정구;송의호;전희종
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권1호
    • /
    • pp.24-29
    • /
    • 2004
  • A new low cost hybrid active filter for thyristor-controlled rectifier load is presented to overcome the high cost problem of the active or the other hybrid active filters. The proposed hybrid active filter which consists of tuned (5th and 7th harmonics) LC passive filters, power factor improvement(PFI) capacitor bank, and active filter compensates power factor as well as harmonic currents. Since most of harmonic currents are filtered by the passive filter and most of reactive power is compensated by the PFI capacitor bank, the power rating of active filter can be minimized, resulting in cost minimization of the proposed hybrid active filter. A 300kVA hybrid active filter system is implemented and tested using 1MVA thyristor rectifier load to verify the operation and performance.