• 제목/요약/키워드: high performance steel fiber reinforced concrete

검색결과 227건 처리시간 0.028초

Permanent Shotcrete Tunnel Linings 구축을 위한 고성능 숏크리트 개발 II (II: 용수부에서의 조강시멘트 적용) (Development of High Performance Shotcrete for Permanent Shotcrete Tunnel Linings II(II: Application of high-early strength cement in sump water condition))

  • 박해균;이명섭;김재권;안병제
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.695-702
    • /
    • 2002
  • Shotcrete (or Sprayed concrete) has been used as an important support material in New Austrian Tunnelling Method (NATM). Since the mid of 1990, permanent shotcrete tunnel linings such as Single-shell, NMT (Norwegian Method of Tunnelling) has been constructed in many countries for reducing the construction time and lowing construction costs instead of conventional in-situ concrete linings. Among essential technologies for successful application of permanent shotcrcte linings, high performance shotcrete providing high strength, high durability, better pumpability has to be developed in advance as an integral component. This paper presents the Ideas and first experimental attempts to increase early strength and bond strength of wet-mixed Steel Fiber Reinforced Shotcrete(SFRS) in sump water condition. In order to increase early strength, a new approach using high-early strength cement with liquid alkali-free accelerator has been investigated From the results, wet-mix SFRS with high-early strength cement and alkali-free accelerator exhibited excellent early strength improvement compared to the ordinary portland content and good bond strength even under sump water condition.

  • PDF

다발형 폴리아미드섬유 보강 콘크리트의 역학적 성능평가 (Evaluation on the Mechanical Performance of Concrete Using Entanglement Polyamide Fiber)

  • 전중규;김규용;전찬기;이수철
    • 한국재난정보학회 논문집
    • /
    • 제8권3호
    • /
    • pp.223-233
    • /
    • 2012
  • 콘크리트의 보강재료로 사용되고 있는 강섬유는 강성이 크고 중량이 무거워 안전관리의 어려움이 있으며, 강섬유의 부식으로 인한 내구성 저하 및 높은 리바운드 손실량이 등이 개선사항으로 요구되고 있다. 이와같이 2009년 개정된 규정에 의해 강섬유 외의 재료보강이 가능해짐에 따라 콘크리트 보강재료로서 강섬유 이외의 다양한 섬유의 적용성 검토가 필요한 실정이다. 강섬유는 기타섬유에 비해 강성이 크고, 섬유의 형상에 따라 부착성능을 개선하였만, 유기섬유의 경우 강섬유에 비해 일반적으로 탄성계수 및 인장강도가 낮고 섬유의 뭉침현상이 발생하여 콘크리트 보강재료로 사용하기 위해서는 적절한 섬유 개질이 필요한 실정이다. 이러한 관점에서, 본 연구에서는 미세섬유를 다발형 단일 개체로서 공기 압출성형을 통해 부착 비표면적을 크게 하여 역학적 성능을 고려하고, 섬유의 표면을 계면 활성제로 개질하여 분산성을 향상시킨 폴리아미드섬유와 강섬유, PP섬유를 혼입한 콘크리트를 비교하여 현장 활용을 위한 기초 자료를 제시하고자 한다.

압축강도 수준을 고려한 강섬유 보강 UHPC와 역T형 강재 합성보의 휨거동 실험 연구 (A Study on the Experiment of Flexural Behavior of Composite Beam with Steel Fiber Reinforced UHPC and Inverted-T Steel Considering Compressive Strength Level)

  • 유성원;서정인
    • 콘크리트학회논문집
    • /
    • 제27권6호
    • /
    • pp.677-685
    • /
    • 2015
  • 최근 일반적인 콘크리트의 단점인 낮은 인장강도 및 휨강도와 취성파괴를 극복하기 위하여 초고성능 콘크리트에 강섬유를 혼입한 강섬유 보강 초고성능 콘크리트(UHPC)에 대한 연구가 주목받고 있다. 본 논문에서는 UHPC의 장점을 극대화하기 위하여 합성보 구성 시에 강재 거더의 상부 플랜지를 없앤 역T형 거더를 적용하여, 콘크리트 압축강도, 섬유 혼입률, 전단연결재 간격 및 바닥판 두께 등의 변수를 가지는 역T형 거더와 UHPC 바닥판을 합성한 합성보를 16 개 제작하고 전단연결재의 거동, 휨거동 특성 등을 실험적으로 파악하고자 하였다. 실험결과를 기준으로 볼 때, 향후 UHPC의 경우 스터의 간격은 100 mm에서 바닥판 두께의 2 또는 4 배 사이로 규정함이 적절할 것으로 예상된다. 또한 대부분 실험 부재의 특성 상대변위는 Eurocode-4의 기준을 만족하므로 연성 거동을 확보하는 것으로 판정되었으며, 전단연결재 간격이 넓은 부재는 설계식의 값보다 실험값이 크게 나와, 비합성 거동 후 UHPC와 강재로 전단연결재 예상저항하중보다 더 큰 극한강도를 발휘하며, 전단연결재 간격이 좁은 부재는 전단연결재가 스스로의 능력에 도달하기 전에 UHPC 상연에서 압축파괴가 급격히 발생됨을 알 수 있었다.

Finite element analysis of longitudinal reinforcement beams with UHPFC under torsion

  • Mohammed, Thaer Jasim;Bakar, B.H. Abu;Bunnori, N. Muhamad;Ibraheem, Omer Farouk
    • Computers and Concrete
    • /
    • 제16권1호
    • /
    • pp.1-16
    • /
    • 2015
  • The proposed techniques to strengthen concrete members such as steel plates, polymers or concrete have important deficiencies in adherence and durability. The use of UHPFC plates can overtake effectively these problems. In this paper, the possibility of using UHPFC to strengthen RC beams under torsion is investigated. Four specimens of concrete beams reinforced with longitudinal bars only were tested under pure torsion. One of the beams was considered as the baseline specimen, while the others were strengthened by ultra-high-performance fiber concrete (UHPFC) on two, three, and four sides. Finite element analysis was conducted in tandem with experimental work. Results showed that UHPFC enhances the strength, ductility, and toughness of concrete beams under torsional load, and that finite element analysis is in good agreement with the experimental data.

Permanent Shotcrete Tunnel Linings 구축을 위한 고성능 숏크리트 개발(III)(시멘트 광물계 분말형 급결제를 사용한 습식숏크리트 현장시험시공) (Development of High Performance Shotcrete for Permanent Shotcrete Tunnel Linings (III) (Field Test of Wet-mixed Shotcrete with Powder Types Cement Mineral Accelerator))

  • 박해균;이명섭;김재권;김용하
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.609-617
    • /
    • 2003
  • The use of Shotcrete(Sprayed concrete) for the support of underground excavations was pioneered by the Civil engineering industry. Permanent shotcrete tunnel linings such as Single-shell, NMT(Norwegian Method of Tunnelling) have been constructed in many countries for reducing construction time and lowering construction costs instead of conventional in-situ concrete linings. Among essential technologies for successful application of Permanent Shotcrete Linings, high performance shotcrete having high strength, high durability, better pumpability has to be developed in advance. This paper presents the ideas and the first field test results of wet-mixed Steel Fiber Reinforced Shotcrete(SFRS) with powder types cement mineral accelerator. From the results, wet-mix SFRS with powdered accelerator exhibited good early strength improvement and less rebound ratio compared to the ordinary accelerator.

  • PDF

Structural performance of fiber reinforced cementitious plinths in precast girder bridges

  • Gergess, Antoine N;Challita, Julie
    • Structural Engineering and Mechanics
    • /
    • 제82권3호
    • /
    • pp.313-323
    • /
    • 2022
  • Steel laminated elastomeric bearings are commonly used in bridge structures to control displacements and rotations and transfer forces from the superstructure to the substructure. Proper knowledge of design, fabrication and erection procedures is important to ensure stability and adequate structural performance during the lifetime of the bridge. Difference in elevations sometimes leads to large size gaps between the bearing and the girder which makes the grout thickness that is commonly used for leveling deviate beyond standards. This paper investigates the structural response of High Strength Fiber Reinforced Cementitious (HSFRC) thin plinths that are used to close gaps between bearing pads and precast girders. An experimental program was developed for this purpose where HSFRC plinths of different size were cast and tested under vertical loads that simulate bridge loading in service. The structural performance of the plinths was closely monitored during testing, mainly crack propagation, vertical reaction and displacement. Analytically, the HSFRC plinth was analyzed using the beam on elastic foundation theory as the supporting elastomeric bearing pads are highly compressible. Closed form solutions were derived for induced displacement and forces and comparisons were made between analytical and experimental results. Finally, recommendations were made to facilitate the practical use of HSFRC plinths in bridge construction based on its enhanced load carrying capacity in shear and flexure.

철근 보강 고성능 섬유보강 콘크리트의 인장 강성 (Tension Stiffening of Reinforced High Performance Fiber Reinforced Cementitious Composites (HPFRCC))

  • 이성철;김재화;조재열;신경준
    • 콘크리트학회논문집
    • /
    • 제22권6호
    • /
    • pp.859-866
    • /
    • 2010
  • 콘크리트의 취성적인 인장 거동을 보완하기 위해 섬유를 혼입한 섬유보강 콘크리트에 대한 연구가 진행되어 왔으며, 그 중 인장균열 이후 변형 경화 거동(strain hardening behavior)을 보이는 고인성 섬유보강 콘크리트(HPFRCC)에 대하여 활발히 연구되고 있다. 하지만, 철근이 없는 HPFRCC의 인장 및 휨거동에 대해 주로 연구가 계속되어온 반면 철근이 배근된 HPFRCC 부재의 인장 거동에 대한 자료는 미흡한 실정이다. 따라서 이 연구에서는 HPFRCC의 인장거동에 대한 철근의 효과를 분석하기 위해 철근이 배근된 HPFRCC 부재를 제작하여 인장 강성(tension stiffening)에 대한 실험을 수행하였고, 인장 강성 실험 결과에서 HPFRCC의 인장 응력-변형률 관계를 도출하였다. HPFRCC는 균열발생 이후에서 항복에 이르기까지 인장 성능을 균일하게 유지하는 것으로 나타났다. 철근이 배근된 HPFRCC의 인장 강도는 철근이 없는 부재에서 측정된 인장강도에 비해 낮아지는 것으로 나타났으며, 이는 HPFRCC의 높은 건조수축량과 철근의 구속효과에 의한 것으로 사료된다. 이 연구에서 확인된 인장강성 실험 결과 및 분석 자료는 HPFRCC를 철근과 함께 적용할 경우 유용하게 활용될 것으로 기대된다.

Mechanical behavior test and analysis of HEH sandwich external wall panel

  • Wu, Xiangguo;Zhang, Xuesen;Tao, Xiaokun;Yang, Ming;Yu, Qun;Qiu, Faqiang
    • Advances in concrete construction
    • /
    • 제13권 2호
    • /
    • pp.153-162
    • /
    • 2022
  • Prefabricated exterior wall panel is the main non-load-bearing component of assembly building, which affects the comprehensive performance of thermal insulation and durability of the building. It is of great significance to develop new prefabricated exterior wall panel with durable and lightweight characteristics for the development of energy-saving and assembly building. In the prefabricated sandwich insulation hanging wall panel, the selection of material for the outer layer and the arrangement of the connector of the inner and outer wall layers affect the mechanical performance and durability of the wall panels. In this paper, high performance cement-based composites (HPFRC) are used in the outer layer of the new type wall panel. FRP bars are used as the interface connector. Through experiments and analysis, the influence of the arrangement of connectors on the mechanical behaviors of thin-walled composite wall panel and the panel with window openings under two working conditions are investigated. The failure modes and the role of connectors of thin-walled composite wallboard are analyzed. The influence of the thickness of the wall layer and their combination on the strain growth of the control section, the initial crack resistance, the ultimate bearing capacity and the deformation of the wall panels are analyzed. The research work provides a technical reference for the engineering design of the light-weight thin-walled and durable composite sandwich wall panel.

초고강도 섬유보강 직사각형 콘크리트보의 모멘트-곡률 관계 (The Moment-Curvature Relationship of the Rectangular Ultra High Performance Fiber Reinforced Concrete Beam)

  • 한상묵;궈칭용
    • 한국방재학회 논문집
    • /
    • 제11권3호
    • /
    • pp.9-15
    • /
    • 2011
  • 압축강도 100 MPa, 140 MPa 초고강도 섬유보강 콘크리트 직사각형보와 기하하적 조건 및 PS힘이 동일한 160 MPa RPC 직사각형보의 휨거동 비교를 통하여 압축강도가 낮은 초고강도 섬유보강 콘크리트 구조물의 거동 특성을 파악하였다. 직사각형보에 철근은 배근되지 않았으며 실험변수로는 강섬유, 콘크리트 압축강도, 프리스트레스 도입 방식, PS강재비 등이다. 모멘트-곡률관계와 하중-처짐관계를 통하여 압축응력이 작은 UHPC 직사각형보의 거동 특징을 분석하였다. 초고강도 섬유보강 콘크리트에 대한 간단한 형태의 응력-변형률 관계를 제안하였으며 이를 이용하여 UHPC 직사각형보에 대한 모멘트-곡률관계를 산정하였다. 실험에 의한 모멘트-곡률관계를 비교한 결과 상당히 일치함을 알 수 있었다.

강섬유 보강 초고성능 콘크리트 보의 비틀림 거동 특성 (Characteristics of Structural Behavior of Steel Fiber Reinforced Ultra High Performance Concrete Beams Subjected to Torsion)

  • 양인환;조창빈;이정우;김병석
    • 콘크리트학회논문집
    • /
    • 제26권1호
    • /
    • pp.87-95
    • /
    • 2014
  • 이 연구에서는 강섬유 보강 초고성능 콘크리트 보의 비틀림 거동을 파악하기 위한 실험연구를 수행하였다. 정사각형 단면을 갖는 6개의 초고성능 콘크리트 보 부재에 대해 하중재하실험을 수행하여 비틀림 거동 특성을 분석하였다. 부재의 실험변수는 강섬유 혼입량과 폐쇄 스터럽량이다. 강섬유 혼입량은 1.0% 및 2.0%로 변화하였고, 폐쇄 스터럽량은 0, 0.35% 및 0.70%로 변화하였다. 실험 결과는 강섬유양이 증가할수록 극한비틀림강도가 증가하고, 폐쇄스터럽량이 증가할수록 극한비틀림강도가 증가하는 것을 나타낸다. 또한, 비틀림 강도 예측식을 제안하였으며, 예측식은 콘크리트, 스터럽 및 강섬유의 비틀림 강도 기여분을 각각 고려하였다. 실험 결과를 이용하여 초고강도 콘크리트 보의 비틀림 강도 예측식의 적합성을 평가하고자 하였다. 비틀림강도 실험 결과를 예측값과 비교하였으며, 예측값은 실험 결과에 거의 근접하고 있는 것으로 나타났다. 따라서, 제안식을 이용하여 초고성능 콘크리트의 비틀림 강도를 효과적으로 예측할 수 있다고 판단된다.