• Title/Summary/Keyword: high pH

Search Result 9,416, Processing Time 0.048 seconds

The Usefulness of Diagnostic Scan Using Technetium-99m Pertechnetate Scintigraphy prior to the First Ablative Radioiodine Treatment in Patients with Well Differentiated Thyroid Carcinoma: A Comparative Study with Iodine-131 (분화된 갑상선암 수술 후 초치료에 있어서 Tc-99m Pertechnetate을 이용한 진단 스캔의 유용성: Iodine-131 스캔과의 비교)

  • Yoon, Seok-Nam;Park, Chan-H.;Hwang, Kyung-Hoon;Kim, Su-Zy;Soh, Eui-Young;Kim, Kyung-Rae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.285-293
    • /
    • 2000
  • Purpose: A prospective comparison was made between imaging with Tc-99m pertechnetate (Tc-99m) and Ioine-131 (I-131) for the detection of residual and metastatic tissue after total thyroidectomy in patients with well-differentiated thyroid carcinoma. Materials and Methods: Initially our patients had imaging with Tc-99m, followed by I-131 within 3 days. The study included 21 patients who had ablation with high dose of I-131 ranging from 100 mCi to 150 mCi. Planar and pinhole images were acquired for both Tc-99m and I-131. Diagnostic images of Tc-99m and I-131 were compared with post-therapy images. Degree of uptake on Tc-99m and I-131 images was scored by four point scale and compared. Results: The results of the Tc-99m study were: 16 of 19 studies (84%) were positive on simple planar images, but 19 of 20 studies (95%) were positive on pinhole images. Conventional I-131 diagnostic imaging on the other hand showed that all studies (100%) were positive on both planar and pinhole images. There was a significant difference in degree of uptake between Tc-99m and I-131 planar images (p<0.05). Only one case of Tc-99m scintigraphy was negative on both planar and pinhole studies (false negative). There was no distant metastasis on the therapeutic I-131 images. Conclusion: Tc-99m scan using pinhole in certain clinical situations is an alternative to the I-131 scan in detecting thyroid or lymph node metastasis prior to the first ablative treatment after thyroidectomy for well-differentiated thyroid carcinoma.

  • PDF

Assessment of Growth Conditions and Maintenance of Law-Protected Trees in Je-cheon City (제천시 보호수의 생육환경 및 관리현황 평가)

  • Yoon, Young-Han;Ju, Jin-Hee
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.2
    • /
    • pp.67-74
    • /
    • 2010
  • Law-protected trees are our precious asset as natural resources with history and tradition and natural heritage which should be protected and maintained well to bequeath next generation. Law-protected trees have not only thremmatologic and genetic meaning but also environmental and emotional meaning for their value to be high. This study investigated location, vitality, wrapping condition of root area and status of maintenance of the trees to figure out their growth environment and status of maintenance in a small-middle city through survey on those of law-protected trees in Je-cheon. There showed 300 more year old trees in Je-cheon mostly and the number of trees located in flat fields was the highest. For location type, village, hill and road types were presented in the order and for degree of development, land for building was found most frequently. The average electric resistance of the formative layer was measured to be $8.4k{\Omega}$ and four trees showed bark separation. Most law-protected trees underwent tree surgery, and complete bareness of root area was observed in a tree. The root area of two trees was covered with concrete. pH of soil was recorded to be 5.0~8.4 with its average of 7.1 and electric conductivity(EC) was less than 0.5 dS/m. For status of maintenance rearing facilities were placed for 16 trees out of totally 48 ones and stone fence was done for three ones. Tree surgery was conducted for 33 trees to prevent and to treat decomposed parts of holes. Direction boards were installed for 23 trees. Based on these results, measures to manage systematically law-protected trees in Jecheon could be suggested as follows. First, a sufficient space for growth of low part of trees should be secured. Second, a voluntary management should be induced by advertising them to residents in a community. Third, rearing facilities and direction boards of law-protected trees should be placed and related education should be conducted. Fourth, through operation of the department for law-protected trees consisting of related professions and cooperation among related departments the trees should be maintained continuously.

A Phytosociological Study of the Forest Communities in Mt. Palgong(I) -Pinus densiflora Forests- (팔공산(八公山) 삼림군락(森林群落)의 식물사회학적연구(植物社會學的硏究)(I) -소나무림(林)에 대해서-)

  • Cho, Hyun Je;Hong, Sung Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.79 no.2
    • /
    • pp.144-161
    • /
    • 1990
  • Pine forest communities developed in Mt. Palgong, southeastern Korea, were studied phytosociologically, with special reference to multiple management of local forests, and were classified into two communities, Pinus densiflora - Quercus mongolica community(I : mountain forest) and P. densiflora-Climbing plants community (II : valley forest) and six subgroups accompanied by several subgroups. Judging from the coincidence method, the division of communities (vegetation units) was closely related to altitude and topography. Based on vegetation units, a vertical distribution map of pine forest communities was prepared. The species composition(%) of pine forest communities under stratification, in upper and lower tree layer, teas I higher than II, in middle and shrubs lacer II higher than I (Total : Upper 15.5%, Middle 28.4%, Lower 34.6%. Shrubs 21.5%. Sum of mean coverage%i of understory vegetation was II twice as high as I (Total. shrubs 28.4%. forbs 11.4%, Graminoids 11.8%, ferns 1.0%). Based on constance, coverage and d.b.h. class etc., an actual growth and occurrence table of tree species and understory vegetation by vegetation unity were prepared, and could assume a criterion for judging potential dominance-growth conditions.

  • PDF

Method Development for Determination of Chlorogenic Acid and Arbutin Contents in Fruits by UHPLC-MS/MS (UHPLC-MS/MS를 이용한 과일류 중 클로로젠산 및 알부틴 동시분석법 개발)

  • Choi, Young-Ju;Jeon, Jong-Sup;Kim, Woon-Ho;Jung, You-Jung;Ryu, Ji-Eun;Choi, Jong-Chul;Chae, Kyung-Suk;Lee, Jin-Hee;Do, Young-Sook;Park, Young-Bae;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.5
    • /
    • pp.413-420
    • /
    • 2019
  • In this study, a sample preparation method and a simultaneous determination method by ultra-high performance liquid chromatography coupled with tandem mass spectrometry for 9 isomers of chlorogenic acid and arbutin in fruits were developed. The samples were extracted using 90% methanol (pH 3.0), with the solutions being shaken and then sonicated for 10 min each. After centrifugation at 4,000 rpm for 10 min, the extraction was concentrated under a vacuum at $40^{\circ}C$ using a vacuum evaporator. The residue was dissolved in 5 mL of 5% methanol and filtered through a $0.45{\mu}m$ membrane before UHPLC-MS/MS analysis. The separations were performed on a C18 column with gradient elution of water (containing 0.1% formic acid) and methanol (containing 0.1% formic acid). The specificity, linearity, limit of detection, limit of quantification, accuracy, and precision of the proposed methods were also evaluated.

Compaction Characteristics of Multi-cropping Paddy Soils in South-eastern Part of Korea (우리나라 동남부 다모작 논토양의 경반화 특성)

  • Yun, Eul-Soo;Jung, Ki-Yeul;Park, Ki-Do;Sonn, Yeon-Kyu;Park, Chang-Yeong;Hwang, Jae-Bog;Nam, Min-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.688-695
    • /
    • 2011
  • This study was carried out for some survey about soil compaction in the multi-cropping system of paddy field. Investigated sites were 90 farmer's fields in south-eastern part of Korea. The tillage practices season was different according to cropping system of paddy; in spring for mono rice cultivation and in autumn for the multi-cropping field. The average tillage depth in investigated sites was about 25 cm, however, it is different between the farmer's tillage practices and soil characteristics. It is high correlation to tillage deep and minimum resistance of penetration. The reaching soil deep to maximum resistance of penetration was about 27 cm, and average penetration resistance of the deep is 1.8~2.0 MPa for moderately fine-textured soils and more than 3.0 MPa for moderately coarse-textured soils. The difference of penetration resistance between cultivating and compacted layer was in order to sandy loam > clayey loam > clayey, and the difference was lesser in poorly drained soils than somewhat poorly ones. In the rice mono cropping field, the maximum resistance in no-tillage for 15 years was 1.18~1.25 Mpa at 20~25 cm in soil deep, however, the resistance of field with every year tillage practices was 2.03~2.21 Mpa. In the extremely compacted sandy loam textured soils, the penetration resistance at 30 cm in soil depth was drastically reduced by the subsoil from 5.2 Mpa to 3.2 Mpa, and the watermelon root in plastic film house was deep elongated.

Basic Studies of Korean Native Clerodendron trichotomum Thunberg for Landscape Uses (전통식물 누리장나무의 조경용 소재개발을 위한 기초연구)

  • Han, In-Song;Ha, Yoo-Mi;Kim, Dong-Yeob;Lee, Bong-Ha
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.2
    • /
    • pp.130-138
    • /
    • 2011
  • This study was carried out to investigate growth characteristics and propagation methods of Clerodendron trichotomum for landscape uses. The results are obtained as follows: In the first place, Korean native C. trichotomum was printed in the "Enumeration of plants in Chosun" in 1937 by Tae Hyun Chung. C. trichotomum is a shrub with round shape. This is noted for its late summer flowers, showy fruit and malodorous foliage. White flowers in long-peduncled cymes bloom in the upper leaf axils from late summer into fall. Flowers are followed by small bright blue fruits, each subtended by a fleshy red calyx. C. trichotomum showed high seed germination rate and greater shoot length in plug box than in normal seeding bed. The rooting rate of C. trichotomum according to cutting date was highest on July 7. The optimum date for cutting was on July 7~10 when the shoots were more hardened. Soil acidity ranged from pH 4.58 to 5.52. The most effective method for rooting of C. trichotomum was treatment with 1,000 ppm IBA on July 7 cuttings, which showed rooting rate of over 90%. Korean native C. trichotomum was successfully propagated through soft cutting and seed.

Analysis of the operation status and opinion on the improvement of fishing vessel structure in coastal improved stow net fishery by the questionnaire survey (설문조사를 통한 연안개량안강망어업의 조업 실태 및 어선 구조 개선에 관한 의견 분석)

  • CHANG, Ho-Young;KIM, Min-Son;HWANG, Bo-Kyu;OH, Jong Chul
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.57 no.4
    • /
    • pp.316-333
    • /
    • 2021
  • In order to understand basic data for improving the fishing system and fishing vessel structure in coastal improved stow net fishery, a questionnaire survey and on-site hearing were conducted from May 10 to June 11, 2019 to analyze opinions on the improvement of operation status and fishing vessel structure. The questionnaire survey consisted of ten questions on the operation status of coastal improved stow net fishery and six questions on the improvement of fishing vessel structure, and the results of each question were analyzed by the region, the captain's age, the captain's career and the age of fishing vessel. As a result of analyzing opinions on the operation status of the coastal improved stow net fishery, it was found that the average time required for casting net was 32.8 to 33.0 minutes and that the average time required for hauling net was 41.0 to 42.2 minutes which took 10 to 12 minutes more than for casting net. The most important work requiring improvement during fishing operation (the first priority) were 'hauling net operation,' 'readjustment and storage of fishing gear,' and 'fish handling' and the hardest factor in fishing management were in the order of 'reduction of catch,' 'labor shortage' and 'rising labor costs.' The most institutional improvement that is most needed in coastal improved stow net fishery was an 'using fine mesh nets.' Most of the respondent to the questions on the experience in hiring foreign crews was 'either hiring or willing to hire foreign crews,' and the average number of foreign crews employed was found to be 2.3 to 2.4 persons. The most important reason for hiring (or considering employment) foreign crews was 'high labor costs.' The degree of communication with foreign crews during fishing operation were 'moderate' or 'difficult to direct work.' The most important problem in hiring foreign crews (the first priority) was an 'illegal departure.' As the survey results on the opinion of structural improvement of coastal improved stow net fishing vessel, the degree of satisfaction with fishing vessel structure related to fishing operation was found to be somewhat unsatisfactory, with an average of 3.3 points on a five-point scale. The inconvenient structure of fishing vessel in possession (the first priority), the space needed most for the construction of new fishing vessel (the first priority) and the space considered important for the construction of new fishing vessel (the first prioprity) was a 'fish warehouse.' The most preferred equipment for the construction of new fishing vessel were 'engine operation monitoring' and 'navigation safety devices.' The average size (tonnage class), the average horse power and the average total length of fishing vessel for proper profit and safety fishing operation was between 13.8 and 14.0 tonnes, 808.3 to 819.5 H.P. and 23.4 to 23.5 meters, respectively. The results of the operation status of coastal improved stow net fishery and the requirement for improving the fishing vessel structure are expected to be provided as basic data for reference when we build or improve the fishing vessel.

Newly Synthesized Phosphodiesterase 4 (PDE4) Inhibitor, DWP205505, Inhibits TNF-$\alpha$ Secretion and mRNA Expression

  • Lee, Suk-Kyeong;Lee, Sun-A;Byun, Hye-Sin;Cho, Mi-La;Kim, Wan-Uk;Park, Sung-Hwan;Cho, Chul-Soo;Joo, Young-Shil;Lee, Shin-Seok;Yoo, Eun-Sook;Son, Ho-Jung;Kim, Ho-Youn
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.1
    • /
    • pp.106-112
    • /
    • 1999
  • The therapeutic potential of phosphodiesterase 4(PDE4) inhibitors in inflammatory diseases including some autoimmune diseases has been explored recently with some hopeful results. These PDE4 inhibitors are thought to show their anti-inflammatory effect by down-regulating tumor necrosis factor-a (TNF-$\alpha$) production in lymphocytes and macrophages. A high concentration of TNF-$\alpha$has been found in rheumatoid arthritis (RA) synovium and reducing TNF-$\alpha$using biological agents was proven to be an effective RA treatment. To test the possibility of using PDE4 inhibitors for RA treatment, the effects of a newly synthesized PDE4 inhibitor, DWP205505, on TNF-$\alpha$ and IL-10 production was tested in cells isolated from normal peripheral blood and rheumatoid arthritis synovial fluid. Cytokine production was assayed at the protein level by sandwich enzyme-linked immunosorbent assay (ELISA) and at the mRNA expression level by semi-quantitative RT-PCR. Another PDE4 inhibitor, RP73401, was used for comparison. DWP205505 and RP73401 had no harmful effect on cell viability up to 10 $\mu$M concentration during the 24 h culture period. DWP205505 as well as RP73401 significantly reduced TNF-$\alpha$ secretion from lipopolysaccharide (LPS)-stimulated peripheral blood mononuclear cells (pBMC) and synovial fluid mononuclear cells (SFMC). The effect of DWP205505 or RP73401 treatment on the mRNA expression of TNF-$\alpha$ was also studied in LPS-stimulated PBMC and SFMC. TNF-$\alpha$ mRNA expression was increased by LPS stimulation and both of the PDE4 inhibitors suppressed TNF-$\alpha$ mRNA expression. For interleukin-l0 (IL-l0), a little different results were obtained from PBMC and SFMC; IL-l0 secretion was unaffected by LPS stimulation and only minimally affected by both of the PDE4 inhibitors in PBMC. In unstimulated SFMC, DWP205505 and RP73401 slightly enhanced IL-10 secretion, while they reduced IL-l0 secretion from LPS-stimulated SFMC where IL-l0 secretion was a lot higher than unstimulated SFMC. These results suggest that the newly synthesized PDE4 inhibitor DWP205505 may have anti-rheumatoid arthritis activity.

  • PDF

Evaluation of Anti-wrinkle Effect of Peanut Shell Extract and Stability of the Extract in Cosmetic Products (땅콩 겉껍질 추출물의 주름개선 효능 및 화장품 제형에서 추출물의 안정성 평가)

  • Narae Han;Jin Young Lee;Mihyang Kim;Eun Young Choi;Bong-Jeun An;Yu-Young Lee;Moon Seok Kang;Hyun-Joo Kim
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.3
    • /
    • pp.203-212
    • /
    • 2023
  • This study was conducted to investigate the possibility of peanut shell, a by-product of peanut, as a functional cosmetic ingredient. Peanut shell extract showed high antioxidant activity with IC50 values of 75.00, 46.33, and 472.83 ㎍/mL for DPPH and ABTS radical scavenging and SOD-like activity, respectively. Furthermore, peanut shell extract was efficiently decreased the MMP-1 and MMP-3 protein level in the UVB treated-HaCaT cell and maintained procollagen protein level similar to normal control. Similar to anti-wrinkle related protein expression assay, the IC50 value of elastase and collagnease inhibition in peanut shell extract was lower as 0.30 and 0.09 mg/mL, respectively, than that of the positive control. Additionally, eriodictyol and luteolin, which are isolated from peanut shell extract, showed 53.8 and 98.0% elastase inhibition rate, respectively, and 60.1 and 72.5% collagenase inhibition rate, respectively, at a concentration of 0.1 mg/mL. Thus, luteolin was assumed to be the effective ingredient for wrinkle inhibition in peanut shell extract. As a result of stability evaluation of lotion and cream formulations containing peanut shell extract, it was confirmed to be a stable formulation with no significant changes. Therefore, it is considered that peanut shell extract can be applied as a cosmetic ingredient for wrinkle inhibition.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF