• Title/Summary/Keyword: high isolation

Search Result 1,967, Processing Time 0.023 seconds

Application of Hybrid Seismic Isolation System to Realize High Seismic Performance for Low-rise Lightweight Buildings (저층 경량건물의 고성능 내진을 위한 복합면진시스템의 적용)

  • Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.4 no.2
    • /
    • pp.185-192
    • /
    • 2013
  • This study presents application effects of hybrid seismic isolation system to realize high seismic performance for low-rise lightweight buildings through a non-linear analysis and onsite experiments. The complex seismic isolation system applied in this study is a method of mixing sliding bearing and laminated rubber bearing in order to overcome limitation of laminated rubber bearing in increasing natural period of the whole seismic isolation system. As a result of the non-linear analysis, seismic isolation buildings designed with complex seismic isolation system are safe because its maximum response displacement is within allowable design displacement even for a strong earthquake which rarely occurs and its maximum response shear is less than design seismic force. As a result of the onsite experiment, the rigidity of seismic isolation stories corresponds to approximately 95.8% of the design equivalent stiffness value. This indicates that actual properties of the whole seismic isolation system correspond to design values.

Optimal Design of Air-spring and Active Control of Vibration Isolation Table (공기스프링의 최적설계 및 방진 테이블의 능동 제어)

  • An, Chae-Hun;Kim, Ho-Sung;Yim, Kwang-Hyeok;Jin, Kyong-Bok;Rim, Kyung-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.909-914
    • /
    • 2006
  • Vibration isolation tables are mostly required in precise measurement and manufacturing system. Among the vibration isolation tables, an air spring is the most favorable equipment because of low resonant frequency and high damping ratio. However, it is difficult to design the air spring with the required stiffness and damping ratio. Futhermore, whenever conventional active control methods are applied to the air spring, it may be difficult to obtain effective control performance due to high nonlinearity of air spring. In this paper, the optimal design of the air spring is performed using genetic algorithm to bring out low resonant frequency and high damping ratio. Also, active control of the vibration isolation table with 3-DOF model is proposed using the adaptive control method. Through experiments, optimal design is shown to be effective. And performance of the proposed control method is verified to be better than those of the passive control method and the conventional active control methods.

  • PDF

The effect of base isolation and tuned mass dampers on the seismic response of RC high-rise buildings considering soil-structure interaction

  • Kontoni, Denise-Penelope N.;Farghaly, Ahmed Abdelraheem
    • Earthquakes and Structures
    • /
    • v.17 no.4
    • /
    • pp.425-434
    • /
    • 2019
  • The most effective passive vibration control and seismic resistance options in a reinforced concrete (RC) high-rise building (HRB) are the base isolation and the tuned mass damper (TMD) system. Many options, which may be suitable or not for different soil types, with different types of bearing systems, like rubber isolator, friction pendulum isolator and tension/compression isolator, are investigated to resist the base straining actions under five different earthquakes. TMD resists the seismic response, as a control system, by reducing top displacement or the total movement of the structure. Base isolation and TMDs work under seismic load in a different way, so the combination between base isolation and TMDs will reduce the harmful effect of the earthquakes in an effective and systematic way. In this paper, a comprehensive study of the combination of TMDs with three different base-isolator types for three different soil types and under five different earthquakes is conducted. The seismic response results under five different earthquakes of the studied nine RC HRB models (depicted by the top displacement, base shear force and base bending moment) are compared to show the most suitable hybrid passive vibration control system for three different soil types.

A Study on the Diplexer Switch of High Isolation Using Varactor Diode (바랙터 다이오드를 이용한 높은 격리도를 갖는 DIPLEXER 스위치에 관한 연구)

  • Kang Myung-Soo;Park Jun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.4
    • /
    • pp.178-184
    • /
    • 2005
  • In this paper, using diplexer structure and varactor diode controlled by reverse bias voltage for diplexer switch gives possibilities to improve isolation and current characteristics. 1 have newly designed switch with high isolation by application varactor diode corresponding to capacitor of diplexer. The low-pass filter for proposed tunable diplexer passes the microwave signal in the bandwidth for wireless cellular network systems and high-pass filter passes it in the bandwidth for wireless personal communication services (PCS) network systems. As the capacitance of the low-pass filter increases, the cut-off frequency can be moved to low frequency, so that the switch is on state in cellular bandwidth and off state in the PCS bandwidth, in contrast to, as the capacitance for attenuation characteristic of high-pass filter increases, it can be moved to high frequency, so that the switch is off state and on state in the cellular bandwidth. it is possible to improve isolation and current consumption characteristics by application diplexer design methods and varactor diode. 1 expect that the tunable diplexer circuit and design methods should be able to find applications on MMIC and low temperature copired ceramic (LTCC).

A Study on the Characteristic analyses of High Performance Buck-Boost Converter added Electric Isolation (고성능 절연형 벅-부스트 컨버터의 특성 해석에 관한 연구)

  • Kwak, Dong-Kurl;Jung, Do-Young;Lee, Bong-Seob;Kim, Choon-Sam;Shim, Jae-Sun;Yang, Ki-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.142-144
    • /
    • 2008
  • This paper is studied on the characteristic analyses of a high performance buck-boost converter added electric isolation by using a soft switching method. To be achieved of a high performance system, the proposed buck-boost converter is constructed by using a partial resonant circuit. The control switches using in the converter are operated with soft switching for a Partial resonant method. The controlling switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the converter efficiency is high. And the proposed converter is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed converter is adopted with the system development of high efficiency. The soft switching operation and system efficiency of the proposed converter is verified by digital simulation and experimental results.

  • PDF

Study on Development of the Isolation Resistance Measurement System for Hydrogen Fuel Cell Vehicle (수소연료전지자동차용 절연저항 측정시스템 개발에 관한 연구)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Moon, Hyun-Wook;Kim, Hyang-Kon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1068-1072
    • /
    • 2011
  • Hydrogen Fuel Cell Vehicle(HFCV) is system that uses electrical energy of fuel cell stack to main power source, which is different system with other vehicles that use high-voltage, large-current. Isolation performance of this system which is connected with electrical fire and electrical shock is important point. Isolation resistance of electric installation is divided according to working voltage, it follows criterion more than $100{\Omega}$/VDC (or $500{\Omega}$/VAC) about system operation voltage in a hydrogen fuel cell vehicle. Although measurement of isolation resistance in a hydrogen fuel cell vehicle is two methods, it uses mainly measurement by megger. However, the present isolation resistance measurement system that is optimized to use in electrical facilities is unsuitable for isolation performance estimation of a hydrogen fuel cell vehicle because of limit of maximum short current and difference of measurement resolution. Therefore, this research developed the isolation resistance measurement system so that may be suitable in isolation performance estimation of a hydrogen fuel cell vehicle, verified isolation performance about known resistance by performance verification of laboratory level about developed system, and executed performance verification through comparing results of developed system by performance verification of vehicle level with ones of existing megger. Developed system is judged to aid estimation and upgrade of isolation performance in a hydrogen fuel cell vehicle hereafter.

The Association among Activity of Daily Living, Instrumental Activities of Daily Living, Depression and Isolation in Disabled People (장애인의 일상생활동작, 도구적 일상생활동작, 우울 및 고립감의 관계)

  • Choi, Young-Soon;Kim, Hyun-Li;Kim, Young-Hee;Lim, Jae-Ran
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.14 no.1
    • /
    • pp.5-12
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the association among of Activity of Daily Living (ADL), Instrumental Activities of Daily Living (IADL), depression and isolation in disabled people. Method: The subjects consisted of 761 disabled people in Korea. Data were analyzed using descriptive statistics, t-test, ANOVA, and Pearson's correlational statistics. Results: There were significant differences in age, cause of disability, type of disability, degree of disability, education, job, perceived health condition, and economic status between disabled people with high and low levels of ADL and IADL. Depression showed significant differences in type of disability, degree of disability, education, job, perceived health condition, and economic state; isolation showed significant differences in age, cause of disability, type of disability, education, job, residence, perceived health condition, and economic status. A significant association was identified between depression and isolation (r=.69, p<.001). Conclusion: There was a high incidence of depression in disabled men with high levels of isolation and ADL and IADL dependence. An effort to increase disabled people's ADL, IADL, and independence levels is needed, and nursing interventions should be designed and tested to increase their community involvement and decrease the sense of isolation and depression.

Isolation Improvement of a Broadband Antenna Using a High-Permeability Substrate (고투자율 자성기판을 이용한 광대역 안테나 격리도 특성 개선)

  • Hur, Jun;Kay, Youngchul;Choo, Hosung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.24-29
    • /
    • 2015
  • In this paper, we propose a method of isolation improvement for broadband antennas using a high-permeability substrate. The substrate is applied for a planar monopole antenna based on near-field analysis to maintain radiation characteristics at its operating frequency while improving isolation by minimizing mutual coupling with nearby antennas at other frequency bands. To verify isolation improvement, we compare performance variations of $S_{21}$ according to the existence of the substrate using the proposed antenna and a reference antenna whose operating frequency is 2 GHz. As a result, the radiation characteristics are maintained, and $S_{21}$ performance is improved by more than 5~10 dB in the frequency band of greater than 2 GHz, which demonstrates the isolation can be improved by using the high-permeability substrate.

Development of a High-Yield Isolation Protocol Optimized for the Retrieval of Active Muscle Satellite Cells from Mouse Skeletal Muscle Tissue

  • Hyun Lee;Na Rae Han;Seong Jae Kim;Jung Im Yun;Seung Tae Lee
    • International Journal of Stem Cells
    • /
    • v.15 no.3
    • /
    • pp.283-290
    • /
    • 2022
  • Background and Objectives: Difficulties often encountered in separating and purifying active muscle satellite cells (MSCs) from skeletal muscle tissues have limited the supply of cells for muscle therapy and artificial meat production. Here, we report an effective isolation protocol to economically and conveniently retrieve active MSCs from skeletal muscle tissues in mice. Methods and Results: We optimized an enzyme-based tissue digestion protocol for isolating skeletal muscle-derived primary cell population having a large number of active MSCs and described a method of differential plating (DP) for improving purity of active MSCs from skeletal muscle-derived primary cell population. Then, the age of the mouse appropriate to the isolation of a large number of active MSCs was elucidated. The best isolation yield of active MSCs from mouse skeletal muscle tissues was induced by the application of DP method to the primary cell population harvested from skeletal muscle tissues of 2-week-old mice digested in 0.2% (w/v) collagenase type II for 30 min at 37℃ and then in 0.1% (w/v) pronase for 5 min at 37℃. Conclusions: The protocol we developed not only facilitates the isolation of MSCs but also maximizes the retrieval of active MSCs. Our expectation is that this protocol will contribute to the development of original technologies essential for muscle therapy and artificial meat industrialization in the future.

E-Isolation : High-performance Dynamic Testing Installation for Seismic Isolation Bearings and Damping Devices

  • Yoshikazu Takahashi;Toru Takeuchi;Shoichi Kishiki;Yozo Shinozaki;Masako Yoneda;Koichi Kajiwara;Akira Wada
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.1
    • /
    • pp.93-105
    • /
    • 2023
  • Seismic isolation and vibration control techniques have been developed and put into practical use by challenging researchers and engineers worldwide since the latter half of the 20th century, and after more than 40 years, they are now used in thousands of buildings, private residences, highways in many seismic areas in the world. Seismic isolation and vibration control structures can keep the structures undamaged even in a major earthquake and realize continuous occupancy. This performance has come to be recognized not only by engineers but also by ordinary people, becoming indispensable for the formation of a resilient society. However, the dynamic characteristics of seismically isolated bearings, the key elements, are highly dependent on the size effect and rate-of-loading, especially under extreme loading conditions. Therefore, confirming the actual properties and performance of these bearings with full-scale specimens under prescribed dynamic loading protocols is essential. The number of testing facilities with such capacity is still limited and even though the existing labs in the US, China, Taiwan, Italy, etc. are conducting these tests, their dynamic loading test setups are subjected to friction generated by the large vertical loads and inertial force of the heavy table which affect the accuracy of measured forces. To solve this problem, the authors have proposed a direct reaction force measuring system that can eliminate the effects of friction and inertia forces, and a seismic isolation testing facility with the proposed system (E-isolation) will be completed on March 2023 in Japan. This test facility is designed to conduct not only dynamic loading tests of seismic isolation bearings and dampers but also to perform hybrid simulations of seismically isolated structures. In this paper, design details and the realization of this system into an actual dynamic testing facility are presented and the outcomes are discussed.