• 제목/요약/키워드: high energy physics

검색결과 740건 처리시간 0.027초

In Situ X-ray Photoemission Spectroscopy Study of Atomic Layer Deposition of $TiO_2$ on Silicon Substrate

  • Lee, Seung-Youb;Jeon, Cheol-ho;Kim, Yoo-Seok;Kim, Seok-Hwan;An, Ki-Seok;Park, Chong-Yun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.222-222
    • /
    • 2011
  • Titanium dioxide (TiO2) has a number of applications in optics and electronics due to its superior properties, such as physical and chemical stability, high refractive index, good transmission in vis and NIR regions, and high dielectric constant. Atomic layer deposition (ALD), also called atomic layer epitaxy, can be regarded as a special modification of the chemical vapor deposition method. ALD is a pulsed method in which the reactant vapors are alternately supplied onto the substrate. During each pulse, the precursors chemisorb or react with the surface groups. When the process conditions are suitably chosen, the film growth proceeds by alternate saturative surface reactions and is thus self-limiting. This makes it possible to cover even complex shaped objects with a uniform film. It is also possible to control the film thickness accurately simply by controlling the number of pulsing cycles repeated. We have investigated the ALD of TiO2 at 100$^{\circ}C$ using precursors titanium tetra-isopropoxide (TTIP) and H2O on -O, -OH terminated Si surface by in situ X-ray photoemission spectroscopy. ALD reactions with TTIP were performed on the H2O-dosed Si substrate at 100$^{\circ}C$, where one cycle was completed. The number of ALD cycles was increased by repeated deposition of H2O and TTIP at 100$^{\circ}C$. After precursor exposure, the samples were transferred under vacuum from the reaction chamber to the UHV chamber at room temperature for in situ XPS analysis. The XPS instrument included a hemispherical analyzer (ALPHA 110) and a monochromatic X-ray source generated by exciting Al K${\alpha}$ radiation (h${\nu}$=1486.6 eV).

  • PDF

Scaling law in MHD turbulence small-scale dynamo

  • Park, Kiwan;Ryu, Dongsu
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.74.2-74.2
    • /
    • 2014
  • Magnetohydrodynamics(MHD) dynamo depends on many factors such as viscosity ${\gamma}$, magnetic diffusivity ${\eta}$, magnetic Reynolds number $Re_M$, external driving source, or magnetic Prandtl number $Pr_M$. $Pr_M$, the ratio of ${\gamma}$ to ${\eta}$ (for example, galaxy ${\sim}10^{14}$), plays an important role in small scale dynamo. With the high PrM, conductivity effect becomes very important in small scale regime between the viscous scale ($k_{\gamma}{\sim}Re^{3/4}k_fk_f$:forcing scale) and resistivity scale ($k_{\eta}{\sim}PrM^{1/2}k_{\gamma}$). Since ${\eta}$ is very small, the balance of local energy transport due to the advection term and nonlocal energy transfer decides the magnetic energy spectra. Beyond the viscous scale, the stretched magnetic field (magnetic tension in Lorentz force) transfers the magnetic energy, which is originally from the kinetic energy, back to the kinetic eddies leading to the extension of the viscous scale. This repeated process eventually decides the energy spectrum of the coupled momentum and magnetic induction equation. However, the evolving profile does not follow Kolmogorov's -3/5 law. The spectra of EV (${\sim}k^{-4}$) and EM (${\sim}k^0$ or $k^{-1}$) in high $Pr_M$ have been reported, but our recent simulation results show a little different scaling law ($E_V{\sim}k^{-3}-k^{-4}$, $EM{\sim}k^{-1/2}-k^{-1}$). We show the results and explain the reason.

  • PDF

마이크로웨이브 조사를 이용한 반도체성 단일벽 탄소나노튜브의 선택적 분리 (Selective Separation of Semiconducting Single-Walled Carbon Nanotubes via Microwave Irradiation)

  • 김성환;송우석;김유석;김수연;박종윤
    • 한국진공학회지
    • /
    • 제20권4호
    • /
    • pp.294-299
    • /
    • 2011
  • 본 연구에서는 열화학기상증착법과 나노구조의 Fe/$Al_2O_3$/Si 촉매층을 이용하여 단일벽 탄소나노튜브를 합성하고 마이크로웨이브 조사를 통해 금속성 단일벽 탄소나노튜브를 선택적으로 제거하고 반도체성 단일벽 탄소나노튜브를 분리하였다. 조사시간의 변화에 따른 단일벽 탄소나노튜브의 전기적, 구조적 특성을 분석한 결과, 조사시간이 120초인 경우, 금속성의 단일벽 탄소나노튜브가 선택적으로 제거되어 약 95%의 반도체성 단일벽 탄소나노튜브를 분리할 수 있었으며, 뿐만 아니라 남아있는 반도체성 단일벽 탄소나노튜브가 손상 없이 우수한 결정성을 지니는 것을 확인할 수 있었다. 이러한 방법은 반도체성 단일벽 탄소 나노튜브를 기반으로 한 전계효과 트랜지스터 및 다양한 나노전자소자의 응용에 유용한 정보를 제공하리라 기대한다.

Breast Radiotherapy with Mixed Energy Photons; a Model for Optimal Beam Weighting

  • Birgani, Mohammadjavad Tahmasebi;Fatahiasl, Jafar;Hosseini, Seyed Mohammad;Bagheri, Ali;Behrooz, Mohammad Ali;Zabiehzadeh, Mansour;meskani, Reza;Gomari, Maryam Talaei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권17호
    • /
    • pp.7785-7788
    • /
    • 2015
  • Utilization of high energy photons (>10MV) with an optimal weight using a mixed energy technique is a practical way to generate a homogenous dose distribution while maintaining adequate target coverage in intact breast radiotherapy. This study represents a model for estimation of this optimal weight for day to day clinical usage. For this purpose, treatment planning computed tomography scans of thirty-three consecutive early stage breast cancer patients following breast conservation surgery were analyzed. After delineation of the breast clinical target volume (CTV) and placing opposed wedge paired isocenteric tangential portals, dosimeteric calculations were conducted and dose volume histograms (DVHs) were generated, first with pure 6MV photons and then these calculations were repeated ten times with incorporating 18MV photons (ten percent increase in weight per step) in each individual patient. For each calculation two indexes including maximum dose in the breast CTV ($D_{max}$) and the volume of CTV which covered with 95% Isodose line ($V_{CTV,95%IDL}$) were measured according to the DVH data and then normalized values were plotted in a graph. The optimal weight of 18MV photons was defined as the intersection point of $D_{max}$ and $V_{CTV,95%IDL}$ graphs. For creating a model to predict this optimal weight multiple linear regression analysis was used based on some of the breast and tangential field parameters. The best fitting model for prediction of 18MV photons optimal weight in breast radiotherapy using mixed energy technique, incorporated chest wall separation plus central lung distance (Adjusted R2=0.776). In conclusion, this study represents a model for the estimation of optimal beam weighting in breast radiotherapy using mixed photon energy technique for routine day to day clinical usage.

Structural Characterization and Dielectric Studies of Superparamagnetic Iron Oxide Nanoparticles

  • Sivakumar, D.;Naidu, K. Chandra Babu;Nazeer, K. Prem;Rafi, M. Mohamed;kumar, G. Ramesh;Sathyaseelan, B.;Killivalavan, G.;Begam, A. Ayisha
    • 한국세라믹학회지
    • /
    • 제55권3호
    • /
    • pp.230-238
    • /
    • 2018
  • Superparamagnetic iron oxide nanoparticles (SPIONs) have been prepared without using surfactants to assess their stability at different time intervals. The synthesized particles were characterized by X-ray diffraction, Fourier-transform infrared spectroscopy, ultraviolet-visible-near infrared spectroscopy, and energy dispersive spectroscopy. Field emission scanning electron microscopy and high-resolution transmission electron microscopy images of the samples were also investigated. The average particle size was measured to be 12.7 nm even in the polydispersed form. The magnetic and dielectric characteristics of the $Fe_3O_4$ nanoparticles have also been studied and discussed in detail.

CsSrCl3 단결정의 섬광특성 (Scintillation properties of CsSrCl3 single crystal)

  • 도시홍;김성환;나세진;김홍주;강희동;오문영
    • 센서학회지
    • /
    • 제16권5호
    • /
    • pp.337-341
    • /
    • 2007
  • $CsSrCl_{3}$ crystal was grown using Czochralski method from equimolar mixture of CsCl and $SrCl_{2}$. The spectrum range of the luminescence excited by 205 nm of wavelength was about $280{\sim}550$ nm, and its peak emission appeared at 343 nm. The luminescence decay curve of the $CsSrCl_{3}$ revealed two exponential components with time constants of 60 ns and 700 ns. The energy resolution for $^{137}Cs$ 662 keV ${\gamma}$-ray was 10.3 %. The pulse shape was linear at high energy, but some deviation existed in the low energy region.

구리 산화물 계열 초전도체에서의 스핀 요동에 의한 자체 에너지의 엘리아시버그 계산 (Eliashberg Calculation of the Momentum-Resolved Self-Energy for the Cuprate Superconductors Induced by the Spin Fluctuations)

  • 홍승환;최한용
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.146-150
    • /
    • 2012
  • We solve the momentum resolved d-wave Eliashberg equation employing the magnetic excitation spectrum from the inelastic neutron scattering on the LSCO superconductors reported by Vignolle et al. The magnetic excitation spectrum exhibits 2 peaks: a sharp incommensurate peak at 18 meV at momentum (${\pi}$, ${\pi}{\pm}{\delta}$) and (${\pi}{\pm}{\delta}$, ${\pi}$) and another broad peak near 40~70 meV at momentum (${\pi}$, ${\pi}$). Above 70 meV, the magnetic excitation spectrum has a long tail that is shaped into a circle centered at (${\pi}$, ${\pi}$) with ${\delta}$. The sign of the real part of the self-energy is determined by the momentum position of the peaks of the magnetic excitation spectrum and bare dispersion. We will discuss the effects of the each component of the magnetic excitation spectrum on the self-energy, the pairing self-energy.

타운젠트 방전에서 전자의 충돌 (The Collision of Electrons in the Townsend's Discharge)

  • 조연찬;이은웅;조현길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.224-225
    • /
    • 2007
  • This paper is to be linked the discharge theory with parameter t the coefficient of restitution used in physics. The collisions is of particular importance in high voltage engineering, nuclear, and high-energy physics. Here the bodies collided may be atoms, nuclei or various elementary particles, such as electrons, protons, and so on.

  • PDF

Space Physics Sensor on KOMPSAT-1

  • Min, Kyoung-Wook;Choi, Young-Wan;Shin, Young-Hoon;Lee, Jae-Jin;Lee, Dae-Hee;Kim, Jhoon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.355-360
    • /
    • 1998
  • A small package of plasma instruments, Space Physics Sensor, will monitor the space environment and its effects on microelectronics in the low altitude region as it operates on board the KOMPSAT-1 from 1999 over the maximum of the solar cycle 23. The Space Physics Sensor (SPS) consists of two parts: the Ionospheric Measurement Sensor (IMS) and the High Energy Particle Detector (HEPD). IMS will make in situ Measurements of the thermal electron density and temperature, and is expected to provide a global map of the thermal electron characteristics and the variability according to the solar and geomagnetic activity in the high altitude ionosphere of the KOMPSAT-t orbit. HEPD will measure the fluxes of high energy protons and electrons, monitor the single event upsets caused by these energetic charged particles, and give the information of the total radiation dose received by the spacecraft. The continuous operation of these sensors, along with the ground measurements such as incoherent scatter radars, digital ionosondes and other spacecraft measurements, will enhance our understanding of this important region of practical use for the low earth orbit satellites.

  • PDF