• Title/Summary/Keyword: high early strength concrete

Search Result 461, Processing Time 0.035 seconds

Compressive Strength Properties of Concrete According to Binder Types and Cement Fineness (결합재 종류 및 시멘트 분말도 변화에 따른 콘크리트의 강도 특성)

  • Park, Do-Young;Park, Nam-Yong;Kim, Dong-Woo;Shin, Hyun-Sup;Yang, Hyun-Soo;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.5-6
    • /
    • 2017
  • This study is to analyze the properties of concrete according to the types of binders and cement powder and to utilize them as fundamental data for the development of early strength concrete. In the case of fluidity, all of the formulations satisfied the 180±25mm, and the flowability of HSF was decreased by high fineness cement. For the air content, 4.5±1.5% of the total content was satisfied. Compressive strength of HSF was found to satisfy the 5MPa in 2days of aging. In case of 28 days of aging, the strength of HSF was more than 24MPa.

  • PDF

A study on the Shrinkage Properties of precast concrete using Calcium hardening accelerator (칼슘계 경화촉진제를 사용한 프리캐스트 콘크리트의 수축특성에 관한 연구)

  • Min, Tae-Beom;Jo, In-Seong;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.44-45
    • /
    • 2014
  • On this study, initial crack index was evaluated by performing FEM analysis to crack propagation from hydration heat for development of precast concrete. On the result, as increased the usage of hardening accelerator, initial compressive strength were improved and setting time also was shortened. Additionally, central temperature of concrete was increased, the reaching time for the highest temperature could be shortened. By the result to assess crack index, there was no problem about crack despite of growth of initial high hydration heating. This result guessed because of small size element when analyzed trough FEM, realization for mass concrete's crack index should be performed.

  • PDF

Evaluation of Air Void System and Permeability of Latex-Modified Concrete by Image Analysis Method

  • Jeong, Won-Kyong;Yun, Kyong-Ku;Hong, Seung-Ho
    • International Journal of Concrete Structures and Materials
    • /
    • v.19 no.1E
    • /
    • pp.41-48
    • /
    • 2007
  • Addition of latex to concrete is known to increase its durability and permeability. The purpose of this study is to analyze air void systems in latex-modified concretes using a reasonable and objective method of image analysis with such experimental variables as water-cement (w/c) ratios, latex contents (0%, 15%) and cement types (ordinary portland cement (OPC), high-early strength (HES) cement and very-early strength (VES) cement). The results are analyzed by spacing factor, air volume (content) after hardening, air void distribution and structure. Additionally, air void systems and permeability of latex-modified concrete (LMC) are compared by a correlation analysis. The results are as follows. The LMC of the same w/c ratio showed better air entraining (AE) effect than OPC with AE water reducer. The VES-LMC showed that the quantity of entrained air below $100{\mu}m$ increased more than four times. For the case of HES-LMC, microscopic entrained air between the range of 50 to $500{\mu}m$ increased greater than 7 times even in the absence of anti-foamer. Although spacing factor was measured rather low, the permeability of latex-modified concrete was good. It is construed that air void system does not have a considerable effect on the property of latex-modified concrete, but latex film (membrane) has a definite influence on the durability of LMC.

An Experimental Study on the Structure Application of High Streength Ready Mixed Concrete - part 2 : Properties of Hardened State and Quality Control - (고강도 레미콘의 구조체 적용에 관한 실험적 연구 - 제2보 : 경화상태 특성 및 품질관리 -)

  • 김기철;이진규;윤기철;연흥흠;최강순;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.18-21
    • /
    • 1995
  • Continued from study on fresh concrete properties of the part 1, this study is designed for analyzing to the increasing trend of the compressive strength according to the curing method, standard deviation, strength properties of pumping before and after, and a length change to the drying shrinkage. And for quality control, this study is designed for analyzing the early estimation of compressive strength by hydrometer method in diluted concrete solution at the fresh state, and non-destructive testing by the Schumidt hammer at the hardened state.

  • PDF

Properties of Strength Development Under Various Curing Condition at Early Age of Cement Mortar Using Agent for Enduring Cold Weather (내한성 혼화제를 이용한 시멘트 모르타르의 초기양생 온도변화에 따른 강도증진 특성)

  • Han, Cheon-Goo;Hong, Sang-Hee;Kim, Hyun-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.191-197
    • /
    • 2001
  • In this study, the admixtures for agents for enduring cold weather used widely are collected and applied to cement mortar to analyze the strength development due to variation of curing temperature at early age. The test results show that anti-freezing admixture have some problems due to high chloride content, which may cause the corrosion of reinforcement embedded in concrete. However, the mortar applied by accelerator and another kind of agent for enduring cold weather produced by S company lead to delay of strength development in low temperature. Also, it is clarified that there are no significant problems for cement mortar in strength development due to low temperature if a suitable kind of agent enduring cold weather is used and cement mortar is cured for more than $7.5^{\circ}D.D$ at early age.

  • PDF

Performance Improvement of High Performance Shrinkage Reducing Agent using Early Strength Improving Agent (조기강도 개선제를 활용한 고성능 수축저감제의 성능 개선)

  • Park, Jong-Pil;Jung, Yong-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.296-302
    • /
    • 2016
  • Studies aimed at reducing the occurrence of cracks by the shrinkage of concrete are in demand because the repair and reinforcement for cracks caused by declining concrete durability costs the user to maintain the concrete structure. In particular, in underground power facilities for power transmission, the cost is a heavy burden to repair and reinforce. For this reason, underground power facilities demanded effective methods for crack reduction at the engineering design step. This study, as a part of the development of shrinkage reducing agent for low shrinkage concrete on underground power facilities, investigated TEA to complement the shrinkage reducing agent to improve the early strength of concrete. In the case of TEA 3% as a shrinkage reducing agent, the early strength was improved significantly, and the shrinkage reducing effect was excellent. In addition, TEA 3.0 % and the shrinkage reducing agent 2.0 % showed excellent shrinkage property and compressive strength. On the other hand, more study of shrinkage reducing materials, including performance reviews on the shrinkage reducing materials with variable factors and type of materials, will be needed to generalize these results.

Fundamental Study on the Strength Development of Cement Paste using Hardening Accelerator and High-Early-Strength Cement (경화촉진제와 조강시멘트를 사용한 시멘트 페이스트의 강도발현에 대한 기초적 연구)

  • Min, Tae-Beom;Cho, In-Sung;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.4
    • /
    • pp.407-415
    • /
    • 2013
  • The purpose of this research is to verify the performance of hardening accelerator in cement paste through mechanical performance evaluation and micro structure analysis on hardening accelerator for development of super high early strength concrete. The research results showed that hardening accelerator produced $Ca(OH)_2$ when hydrated with cement, enhancing the degree of saturation of Ca ion by using differential thermal analysis. Moreover, porosity was reduced rapidly as capillary pores were filled by hydration products of $C_3S$. According to the experiment using hydration measurement testing, when 1% and 3% of accelerator were mixed, hydration rate increased toward the second peak point compared to high early strength cement, before the first peak point disappeared. It turned out that adding accelerator accelerated the hydration rate of cement, especially $C_3S$. The shape of C-S-H is shown depending on the amounts of accelerator added and the production and age of $Ca(OH)_2$ by using SEM to observes hydration products. Therefore, it's evident that hardening accelerator used in this research increases amounts of $Ca(OH)_2$ and accelerates $C_3S$, it is effective for the strength development on early age.

The Study of Physical Properties of Fly Ash Concrete Using Activator (자극제를 사용한 플라이애쉬 콘크리트의 물리적 특성에 관한 연구)

  • Park, Jong-Ho;Kim, Jung-Bin;Won, Eun-Mi;Park, Bong-Soon;Lee, Joung-Ah;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.565-568
    • /
    • 2008
  • Because of low early compressive strength, the usage of fly ash is subject to restriction in comparison with blast-furnace slag powder. Therefore, high amount of fly ash is reclaimed in landfill in face of better economical efficiency and more production. In this paper, the primary aim is to determine to what the basic material characteristics of fly ash concrete is affected by activator, the second aim is to check a possibility of increase in fly ash application. This study show that compared with fly ash concrete using general admixture, fly ash concrete using activator have higher early compressive strength under similar slump, air content, loss. If additional study will inspect performance of activator in various factor, expansion of application of fly ash concrete using activator can be possible.

  • PDF

Basic Properties of Concrete with Ultrafine-Blaine Air Cooling Slag as Admixture (초미분말 서냉 슬래그를 혼화재로 사용한 콘크리트의 기초적 특성)

  • Heo, Jae-Hyuk;Jeong, Sung-Wook;Her, Jae-Won;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.2
    • /
    • pp.77-83
    • /
    • 2009
  • In this study, a test has been carried out to solve the problem with ground granulated blast-furnace slag, low early strength & lack of supply and to find out a way to use as concrete admixture of the ultrafine blaine air cooling slag which is all disposed as the by product of air cooling slag and its test was conducted to the replacement rate of ultrafine blaine air cooling slag & mixing condition of every concrete admixtures by type for the purpose of obtaining later a basic data for practical use of the cement that used ultrafine blaine air cooling slag by conducting comparative analysis. If ultrafine-blaine air cooling slag is used to the concrete following the results, a high efficiency water reducing agent won't be needed much for flow acquisition due to a high increase in flow, and the stripping time of concrete form will be shortened thanks to the acquisition of early strength, And though, it has the problems with long term strength which is similar or a little lower than the 3 types of ground granulated blast-furnace slag, it's still applicable as the substitute materials for 3 types of ground granulated blast-furnace slag at 10, 15% replacement rate of ultrafine-blaine air cooling slag, at which it shows higher activation index than 3 types of ground granulated blast-furnace slag.

An Experimental Study on the Hydration Heat of Self-Compacting Concrete (다성분계 초유동 콘크리트의 수화열에 관한 실험적 연구)

  • Joung, Won-Seoup;Kwon, Ki-Joo;Nah, Hwan-Seon;Oh, Byoung-Cheol;Noh, Jea-Myoung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.152-155
    • /
    • 2004
  • Recently constructions of large scale infrastructures have been tending upwards, due to continuous growth of economy and increase of demands. In addition, hydration heat occurs rapidly in early age just after casting of concrete owing to higher strength and massive structure of concrete. Consequently, cracks and residual stress are developed in accordance to field condition. Moreover, These have harmful influences on safety, durability, watertight, waterproof, and shape of concrete structure. In this study, hydration heat tests were conducted on three of self-compacting concrete and one of high strength concrete. Heat generation and temperature are compared and evaluated based on the test results.

  • PDF