• 제목/요약/키워드: high dose rate

검색결과 878건 처리시간 0.039초

CCD 카메라를 이용한 전자빔 조사량의 예측 (Estimation of Electron Dose Rate using CCD Camera)

  • 김진규;김영민;김윤중;이상희;홍기민;오상호
    • Applied Microscopy
    • /
    • 제39권1호
    • /
    • pp.79-83
    • /
    • 2009
  • We report a useful method to estimate the electron dose rate which may be a decisive factor to characterize sample properties. Even though most mircoscopes have their own exposure meters, there are several practical concerns when such exposure meters are used to measure the electron dose rate: 1) Specimen should be avoided within the entire area of exposure meter; 2) beam current has to be always recorded whenever the operation mode is changed; 3) the electron dose rate can not be calculated for the beam current beyond the detectable range. To overcome these limitations, we suggest a useful method which utilize a CCD (charge coupled device) camera which is now a popular detector to obtain the final electron micrographs. We have evaluated the CCD sensitivity using the linear relationship between electron current on the exposure meter and counter ratio on the CCD camera which are built in KBSI-HVEM (high voltage electron microscope). Applying the new method, we obtained the CCD sensitivity which are approximately 0.039 counts/$e^-$ and 1.37 counts/$e^-$ for the Top-TV and the HV-GIF CCD cameras, respectively.

FIGO병기 IIB 자궁경부암에서 고선량 강내 방사선치료후의 후기 직장 합병증 (Late Rectal Complication in Patients treated with High Dose Rate Brachytherapy for Stage IIB Carcinoma of the Cervix)

  • 정은지;김귀언;서창옥;금기창;김우철
    • Radiation Oncology Journal
    • /
    • 제14권1호
    • /
    • pp.41-52
    • /
    • 1996
  • 목적 : 외부 방사선 치료(External Radiation Therapy) 및 Gamma-med (Iridium-192) 고선량 강내 방사선 치료를 받은 자궁 경부암 FIGO stage IIB 환자에서 직장 합병증 발생률 및 이와 관계있는 인자를 후향적으로 분석해 보았다. 대상 및 방법 : 1989년 11월부터 1992년 12월까지 연세암센터 치료방사선과에서 근치적 목적의 외부 및 강내 방사선치료를 받은 FIGO 병기 IIB 자궁경부암 환자 88명을 대상으로 방사선치료후 발생한 직장 합병증 및 이와 연관된 인자들을 분석하여 보았다. 환자들의 연령은 29-83세로 평균치, 중앙치 모두 57세였고 병리조직 분류상 편평상피세포암이 84예 선암이 4예였다. 방사선치료는 외부방사선을 골반 부위에 5-6주 동안 4500-5400cGy 치료하였으며 환자별로 중간 차폐를 시행하였고 고선량 Gamma-med ICR은 A점에 1회당 500cGy씩 1주 2회로 총 3000cGy 조사하였다. 외부 방사선치료시 중앙 차폐까지의 외부 조사량, ICR rectal dose(r) 및 total rectal dose(R), ICRU 38에 따른 ICR rectal dose(Dr)와 total Dr dose(OR), ICR reference volume, TDF, BED(Biologically Effective Dose)를 계산하고 분석해 합병증과의 연관성을 찾아보았다. 대상 환자 88명중 87명($98.9\%$)에서 최저 24개월 이상 추적 관찰이 가능하였으며 중앙치는 40개월(20-66개월)이었다. 결과 : 직장 합병증은 27예에서 발생하였는데($30.7\%$) grade 1이 12예($13.6\%$), 2가 12예($13.6\%$), 3이 3($3.4\%$)예였고 합병증이 발생하는 시기는 망사선치료후 4-43개월(중앙치 16개월, 평균 17.3개월)이었다. 직장 합병증이 발생하지 않은 환자군의 total rectal dose(R)는 $6772.67{\pm}884.02$로 grade 2-3 합병증이 발생한 15명의 R=$7163.0{\pm}838.49$와 유의한 차이를 보였으며 total Dr dose (DR)도 두 군간에 차이를 보였다 또 grade 2-3인 직장 합병증 발생률은 중앙 차폐시 까지의 외부 방사선량과 관계가 있었는데 36Gy이하에서는 $10\%$, 36-40Gy는 $21.4\%$, 40Gy 이상에서는 $29.3\%$의 직장 합병증이 발생하여 중앙 차폐까지 조사된 외부 방사선량이 증가할수록 직장 합병증이 증가함을 알 수 있었다. 직장에 조사된 총직장 조사량(R)에 따라 grade 2-3 합병증 발생률이 증가하였는데 65Gy 이하에서는 $10.5\%$, 65-75Gy는 $17.2\%$, 75Gy이상 조사된 환자군에서는 $28.5\%$로 조사량이 증가할수록 직장 합병증이 증가하는 알상이었으며 ICRU 38 에 따른 total rectal dose (DR)에 대해서도 비슷한 양상이었다. ICR rectal dose(r, Dr)만 따로 분석해 보았는데 방사선량과 직장 합병증간에는 차이가 없었다. 그 외의 인자로 분석한 TDF 와 BED도 grade 2-3의 경우에는 그 값이 증가할수록 증가하는 양상을 보였으나 통계적인 유의성은 없었고 Gamma Dot 에서 계산되는 ICR reference volume도 분석해 보았으나 합병증파의 연관성을 발견할 수 없었다. 결론 : 병기 IIB 자궁경부암 환자에서 외부 방사선치료 및 고선량 강내 방사선치료후 직장 합병증 발생률은 $30.7\%$(grade 2-3: 15예 $17\%$)였다. 직장 합병증 발생에 영향을 미치는 중요한 인자는 직장에 조사된 전골반 방사선량(중앙 차폐까지의 방사선량) 및 고선량 강내 방사선 치료와 합한 총직장 방사선량(r, Dr)으로 나타났으며 이들이 증가할수록 합병증 발생률이 증가하였다.

  • PDF

High Dose Rate Brachytherapy in Two 9 Gy Fractions in the Treatment of Locally Advanced Cervical Cancer - a South Indian Institutional Experience

  • Ghosh, Saptarshi;Rao, Pamidimukkala Bramhananda;Kotne, Sivasankar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권16호
    • /
    • pp.7167-7170
    • /
    • 2015
  • Background: Although 3D image based brachytherapy is currently the standard of treatment in cervical cancer, most of the centres in developing countries still practice orthogonal intracavitary brachytherapy due to financial constraints. The quest for optimum dose and fractionation schedule in high dose rate (HDR) intracavitary brachytherapy (ICBT) is still ongoing. While the American Brachytherapy Society recommends four to eight fractions of each less than 7.5 Gy, there are some studies demonstrating similar efficacy and comparable toxicity with higher doses per fraction. Objective: To assess the treatment efficacy and late complications of HDR ICBT with 9 Gy per fraction in two fractions. Materials and Methods: This is a prospective institutional study in Southern India carried on from $1^{st}$ June 2012 to $31^{st}$ July 2014. In this period, 76 patients of cervical cancer satisfying our inclusion criteria were treated with concurrent chemo-radiation following ICBT with 9 Gy per fraction in two fractions, five to seven days apart. Results: The median follow-up period in the study was 24 months (range 10.6 - 31.2 months). The 2 year actuarial local control rate, disease-free survival and overall survival were 88.1%, 84.2% and 81.8% respectively. Although 38.2% patients suffered from late toxicity, only 3 patients had grade III late toxicity. Conclusions: In our experience, HDR brachytherapy with 9 Gy per fraction in two fractions is an effective dose fractionation for the treatment of cervical cancer with acceptable toxicity.

위장관 종양의 고선량율 강내 방사선치료 (Intraluminal High-Dose-Rate Brachytherapy for the Tumors of Gastrointestinal Tract)

  • 최병옥;최일봉;정수미;김인아;최명규;장석균;신경섭
    • Radiation Oncology Journal
    • /
    • 제13권3호
    • /
    • pp.243-252
    • /
    • 1995
  • 목적 : 위장관종양에 대한 고선량율 강내 방사선치료의 결과를 분석하고자 하였다. 방법 : 가톨릭의대 성모병원 치료방사선과에서는 1991년 2월부터 1993년 7월까지 18명의 수술을 할 수 없는 중증의 위장관종양 환자들(식도암-8, 직장암-10)을 대상으로 Iridium-192을 사용하여 원격조정 고선량율 강내 방사선치료에 대한 후향적 분석을 하였다. 연령 분포는 47-87세로, 평균 71세였다. 모든 환자들은 이전에 수술적 조작을 받은적이 없었고, 외부 방사선치료 이후 2주 이내에 고선량율 강내 방사선치료를 하였으며, 고선량율 강내 방사선치료의 일일 조사량은 3-5 Gy (3-4회/1주), 총 조사량은 12-20 Gy로 평균 17 Gy였다. 외부방사선 총 조사량은 41.4-59.4 Gy로 평균 49.0 Gy였다. 추적기간은 3개월에서 31개월이었고, 중앙추적기간은 19개월이었다. 결과 : 식도암에서 완전관해와 부분관해는 각각 %로 같은 결과를 보였으며, 중앙 생존기간과 2년 생존율은 10개월과 13%였다 직장암 10명 중 60%의 환자에서 부분반응을 보였으며, 완전반응은 없었지만, 모든 환자에서 현저한 증상개선을 보였다. 저자는 고선량율 강내 방사선 일일 조사량 및 총 조사량, 외부방사선 조사량이 국소반응율과 생존율에 미치는 영향을 분석, 조사하였다. 이 중, 고선량율 강내 방사선 일일 조사량 및 총 조사량이 직장암의 국소반응율에 가장 큰 영향을 미쳤으며, 이는 통계적 유의성을 보였다 (p<0.05). 식도암에서는 고선량율 강내 방사선 총 조사량이 국소반응율과 생존율에 각각 영향을 미쳤으나, 이는 통계적 유의성은 없었다. 또한, 외부방사선 조사량은 모든 환자에게서 국소반응율과 생존율에 영향을 미치지 않는 것으로 나타났다. 모든 환자들에게서 치료 후 현저한 증상개선을 보였으며, 합병증은 대부분의 환자에서 발생하였는데, 대개의 경우 그 증상이 미비하였고, 수일 이내에 회복되었다. 결론 : 이 논문에서는 상대적으로 짧은 추적기간과 적은 수의 환자들을 대상으로 분석을 하였으나, 고선량율 강내 방사선치료 조작은 위장관 종양의 치료에서 외부 방사선치료의 추가적 요법으로 사용할 수 있을 것으로 생각된다.

  • PDF

131I 방사성 동위원소 치료에 따른 피폭 선량 연구 (The Study of Radiation Exposed dose According to 131I Radiation Isotope Therapy)

  • 장보석;유승만
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.653-659
    • /
    • 2019
  • 본 연구는 고용량 $^{131}I$ 치료 후 방사선원이 된 퇴원 환자로부터 나오는 방사선 피폭에 관해 외부 선량률을 측정하고, 그에 따른 피폭선량을 예측하는 것이 목적이다. 200 mCi 이상 고용량 $^{131}I$ 치료를 받은 30명의 환자에서 구리링 3개를 이용하여 환자로부터 거리 및 방위각에 따른 선량평가를 시행하였다. 정확한 방사선 계측을 위하여 GM 계측기를 이용하여 2명의 측정자가 방위각 8 포인트와 거리 변화를 주며 계측하였다. 측정값을 기반으로 3가지 예측 시뮬레이션을 설정하여 불특정 다수 일반인에 대한 피폭선량을 계산하였다. 1m 높이에서 방위각에 따른 외부 선량률이 가장 높은 부위는 0도이다. 거리에 따른 선량률은 거리별 방위각의 선량률 평균값을 사용하였다. 거리에 따른 외부 선량률의 최고치는 50, 100, 150 cm에서 각각 $214{\pm}16.5$, $59{\pm}9.1{\mu}Sv/h$, $38{\pm}5.8{\mu}Sv/h$ 이다. 고용량 $^{131}I$ 치료 환자가 대중교통을 이용해서 5시간 이동할 때 반경 50 cm 지점의 옆좌석에 안은 불특정 일반인이 받을 수 있는 피폭선량은 1.14 mSv이다. 소변 통(urin bag)을 착용한 퇴원환자로부터 100 cm 거리에서 4일 동안 간병인이 받을 수 있는 최대 피폭선량은 6.5 mSv이다. 퇴원 환자 귀가로 인해 7일 동안 150 cm 거리에서 보호자가 받을 수 있는 최대 피폭선량은 1.08 mSv이다. 개발된 예측 모델링으로 불특정 $^{131}I$ 치료 환자의 주변 일반인에게 적용하였을 때 연간 선량 한도를 단시간에 초과하는 수준이었다. 따라서 본 연구를 통해 현행 고용량 $^{131}I$ 치료 환자의 퇴원 후 주변의 일반인의 방호체계의 합리적인 가이드라인을 제시하는 데 도움을 줄 수 있을 것으로 사료된다.

Microcomputer를 이용한 근접조사 장치의 선량분포 계산 (Calculation of Dobe Distributions in Brachytherapy by Personal Microcomputer)

  • 추성실;박창윤
    • Radiation Oncology Journal
    • /
    • 제2권1호
    • /
    • pp.129-137
    • /
    • 1984
  • In brachytherapy, it is important to determine the positions of the radiation sources which are inserted into a patient and to estimate the dose resulting from the treatment. Calculation of the dose distribution throughout an implant is so laborious that it is rarely done by manual methods except for model cases. It is possible to calculate isodose distributions and tumor doses for individual patients by the use of a microcomputer. In this program, the dose rate and dose distributions are calculated by numerical integration of point source and the localization of radiation sources are obtained from two radiographs at right angles taken by a simulator developed for the treatment planning. By using microcomputer for brachytherapy, we obtained the result as following 1. Dose calculation and irradiation time for tumor could be calculated under one or five seconds after input data. 2. It was same value under$\pm2\%$ error between dose calculation by computer program and measurement dose. 3. It took about five minutes to reconstruct completely dose distribution for intracavitary irradiation. 4. Calculating by computer made remarkly reduction of dose errors compared with Quimby's calculation in interstitial radiation implantation. 5. It could calculate the biological isoffect dose for high and low dose rate activities.

  • PDF

High Dose Rate Cobalt-60 After Loading Intracavitary Therapy of the Uterine Cervical Carcinoma in Srinagarind Hospital, Analysis of Residual Disease

  • Pesee, Montien;Krusun, Srichai;Padoongcharoen, Prawat
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권9호
    • /
    • pp.4835-4837
    • /
    • 2012
  • Objectives: To evaluate residual disease in uterine cervical cancer patients treated with teletherapy using combined high dose rate Cobalt-60 brachytherapy. Materials and Methods: A retrospective study of uterine cervical cancer patients, FIGO stages IB-IVB (International Federation of Gynecologists and Obstetricians recommendations), treated by radiotherapy alone between April 1986 and December 1988 was conducted and the outcomes analysed. The patients were treated using teletherapy 50 Gy/25 fractions, five fractions per week to the whole pelvis together with HDR Cobalt -60 afterloading brachytherapy of 850 cGy/fraction, weekly to point A for 2 fractions. Results: The study covered 141 patients with uterine cervical cancer. The mean age was 50.0 years with a range of 30-78 years. The mean tumor size was 4.1 cm in diameter (range 1-8 cm). Mean follow - up time was 2.94 years (range 1 month-6.92 years). The overall incidence of residual locoregional disease was 3.5%. Residual disease, according to stage IIB, IIIB and IVA was present in 2.78%, 3.37% and 50.0%. It was noted that there was no evidence of residual disease in stage IB and IIA cases. Conclusion: Combined teletherapy along with high dose rate Cobalt -60 brachytherapy of 850 cGy/fraction, weekly to point A for 2 fractions resulted in overall 3.5% residual disease and a 96.5% complete response. The proposed recommendation for improving outcome is initiation of measurements for early detection of disease.

몬테칼로 방법을 이용한 방사성 불소에 대한 L-블럭형 방호장비의 차폐율 및 공간의 선량분포 계산 (Calculation of Shielding Rate and Dose Distribution of Space of L-Block-Type Protective Equipment for Radioactive Fluorine using the Monte Carlo Method)

  • 한동현
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.813-819
    • /
    • 2021
  • 본 연구에서는 방사성 불소의 인체 내 주입 시 방사선 방호목적으로 사용되는 L-블럭형 방호장비의 차폐율과 주변공간의 선량분포를 몬테칼로 방법을 이용해 계산하였다. L-블럭형 차폐장치의 몸체 및 윈도우 부위의 차폐율은 99.99 %였다. 1 m거리에서 계산한 선량분포는 XZ평면의 135°, 45°, 225°, 315°, 180°에서 상대적으로 높게 나타났고, 0°, 90°, 270°에서는 매우 낮게 계산되었다. YZ평면에서는 135°, 180°, 225°에서 상대적으로 높게 나타났고, 나머지 각도에서는 매우 낮게 계산되었다. AZ와 BZ 평면에서도 YZ평면과 유사한 결과를 나타냈다. 또한 선원의 수평방향과 선원의 상방 45°방향의 선량분포를 통해 225°~315°범위에서 차폐율이 가장 우수함을 확인하였다. 이와 같은 결과가 방사선 작업 종사자들의 방사선 방호에 필요한 기초자료로 활용되기를 기대한다.

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

분화성 갑상선암환자의 방사성 요오드 치료시 전리함과 Geiger-Muller계수관에서 방사선량률 측정값 비교 (Comparison of the Measured Radiation Dose-rate by the Ionization Chamber and GM(Geiger-Müller) Counter After Radioactive Iodine Therapy in Differentiated Thyroid Cancer Patients)

  • 박광훈;김구환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.565-570
    • /
    • 2016
  • 방사성 요오드($^{131}I$) 치료는 분화성 갑상선암 환자에서 재발을 감소시키고 생존률을 증가시키나, 환자에서 방출되는 방사능으로 인하여 피폭을 야기시킬 수 있으므로 환자로부터 발생되는 방사선량률을 측정하는 것이 방사선안전관리 측면에서 중요하다. 방사성 요오드($^{131}I$) 치료시 널리 사용되는 측정기 중 전리함과 GM계수관으로 측정된 방사선량률의 감도와 측정효율을 구하였다. 방사성 요오드($^{131}I$)를 150mCi 경구투여 받은 분화성 갑상선암 환자의 상복부로부터 1 m거리에서 경과 시간에 따라 방사선량률을 측정하였다. 시간에 따른 변화를 직접적으로 비교한 결과, 고선량률에서의 감도와 측정효율은 GM계수관보다 전리함이 높게 나타났고, 통계적으로 유의하였다(p<0.05). 저선량률에서의 감도와 측정효율은 GM계수관보다 전리함이 낮게 나타났지만 통계적으로 유의한 차이를 나타내지 않았다(p>0.05). 방사성 요오드($^{131}I$) 치료시에 검 교정이 완료된 전리함과 GM계수관으로 정확하고 신속한 방사선량률을 측정하여 환자에게 설명함으로써 방사성 요오드 치료 후 퇴원하는 환자에게 환자가족 또는 주변 사람들에게 미칠 수 있는 방사선피폭을 예측하고, 불필요한 예단을 줄여줄 수 있을 것이다.