• Title/Summary/Keyword: high current density

Search Result 2,256, Processing Time 0.033 seconds

Microstructure and Electrical Properties of the Pt/Pb1.1Zr0.53Ti0.47O3/PbO/Si (MFIS) Using the PbO Buffer Layer (PbO 완충층을 이용한 Pt/Pb1.1Zr0.53Ti0.47O3/PbO/Si (MFIS)의 미세구조와 전기적 특성)

  • Park, Chul-Ho;Song, Kyoung-Hwan;Son, Young-Guk
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.2 s.273
    • /
    • pp.104-109
    • /
    • 2005
  • To study the role of PbO as the buffer layer, Pt/PZT/PbO/Si with the MFIS structure was deposited on the p-type (100) Si substrate by the r.f. magnetron sputtering with $Pb_{1.1}Zr_{0.53}Ti_{0.47}O_3$ and PbO targets. When PbO buffer layer was inserted between the PZT thin film and the Si substrate, the crystallization of the PZT thin films was considerably improved and the processing temperature was lowered. From the result of an X-ray Photoelectron Spectroscopy (XPS) depth profile result, we could confirm that the substrate temperature for the layer of PbO affects the chemical states of the interface between the PbO buffer layer and the Si substrate, which results in the inter-diffusion of Pb. The MFIS with the PbO buffer layer show the improved electric properties including the high memory window and low leakage current density. In particular, the maximum value of the memory window is 2.0V under the applied voltage of 9V for the Pt/PZT(200 nm, $400^{\circ}C)/PbO(80 nm)/Si$ structures with the PbO buffer layer deposited at the substrate temperature of $300^{\circ}C$.

Characteristics of MHEMT Devices Having T-Shaped Gate Structure for W-Band MMIC (W-Band MMIC를 위한 T-형태 게이트 구조를 갖는 MHMET 소자 특성)

  • Lee, Jong-Min;Min, Byoung-Gue;Chang, Sung-Jae;Chang, Woo-Jin;Yoon, Hyung Sup;Jung, Hyun-Wook;Kim, Seong-Il;Kang, Dong Min;Kim, Wansik;Jung, Jooyong;Kim, Jongpil;Seo, Mihui;Kim, Sosu
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.2
    • /
    • pp.99-104
    • /
    • 2020
  • In this study, we fabricated a metamorphic high-electron-mobility transistor (mHEMT) device with a T-type gate structure for the implementation of W-band monolithic microwave integrated circuits (MMICs) and investigated its characteristics. To fabricate the mHEMT device, a recess process for etching of its Schottky layer was applied before gate metal deposition, and an e-beam lithography using a triple photoresist film for the T-gate structure was employed. We measured DC and RF characteristics of the fabricated device to verify the characteristics that can be used in W-band MMIC design. The mHEMT device exhibited DC characteristics such as a drain current density of 747 mA/mm, maximum transconductance of 1.354 S/mm, and pinch-off voltage of -0.42 V. Concerning the frequency characteristics, the device showed a cutoff frequency of 215 GHz and maximum oscillation frequency of 260 GHz, which provide sufficient performance for W-band MMIC design and fabrication. In addition, active and passive modeling was performed and its accuracy was evaluated by comparing the measured results. The developed mHEMT and device models could be used for the fabrication of W-band MMICs.

Model Trajectory Simulation for the Behavior of the Namgang Dam Water in the Kangjin Bay, South Sea, Korea (남해 강진만에서 남강댐 방류수의 거동 특성 및 체류시간 추정)

  • Jung, Kwang-Young;Ro, Young-Jae;Kim, Baek-Jin;Park, Kwang-Soon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.2
    • /
    • pp.97-108
    • /
    • 2012
  • A Lagrangian particle tracking model coupled with the ECOM3D were used to study on the behavior of fresh water released from the Namgang Dam in terms of residence time in Kangjin Bay, South Sea, Korea. Model was calibrated until skill cores for elevation, velocity, temperature and salinity are satisfied over 85%. In the numerical simulation, particles were released in 1 hour time interval from the northern boundary. The different patterns of particle trajectory are identified under the varying dynamics from tidal to density-driven current. The average residence time of total particles are approximately 65.9 hours in the entire Kangjin Bay. The average residence time were increased from 55~65 to 70~80 hours during maximum discharge period. Discharge rate of fresh water and average residence time in the Kangjin Bay is high correlated with correlation coefficient over 0.81.

A Study of Electromagnetic Actuator for Electro-pneumatic Driven Ventricular Assist Device

  • Jung Min Woo;Hwang Chang Mo;Jeong Gi Seok;Kang Jung Soo;Ahn Chi Bum;Kim Kyung Hyun;Lee Jung Joo;Park Yong Doo;Sun Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.6
    • /
    • pp.393-398
    • /
    • 2005
  • An electromechanical type is the most useful mechanism in the various pumping mechanisms. It, however, requires a movement converting system including a ball screw, a helical cam, or a solenoid-beam spring, which makes the device complex and may lessen reliability. Thus, the authors have hypothesized that an electromagnetic actuator mechanism can eliminate the movement converting system and that thereby enhance the mechanical reliability and operative simplicity of an electro­pneumatic pump. The purpose of this study was to show a novel application of electromagnetic actuator mechanism in pulsatile pump and to provide preliminary data for further evaluations. The electromagnetic actuator consists of stators with a single winding excitation coil and movers with a high energy density neodymium-iron-boron permanent magnet. A 0.5mm diameter wire was used for the excitation coil, and 1000 turns were wound onto the stators core with parallel. A prototype of extracorporeal electro-pneumatic pump was constructed, and the pump performance tests were performed using a mock system to evaluate the efficiency of the electromagnetic actuator mechanism. When forward and backward electric currents were supplied to the excitation coil, the mover effectively moved back and forth. The nominal stroke length of the actuator was 10mm. The actuator dimension was 120mm in diameter and 65mm in height with a mass of 1.4kg. The prototype pump unit was 150mm in diameter, 150mm in thickness and 4.5kg in weight. The maximum force output was 70N at input current of 4.5A and the maximum pump rate was 150 beats per minute. The maximum output was 2.0 L/minute at a rate of 80bpm when the afterload was 100mmHg. The electromagnetic actuator mechanism was successfully applied to construct the prototype of extracorporeal electro­pneumatic pump. The authors provide the above results as a preliminary data for further studies.

Association of Current and Past Smoking with Metabolic Syndrome in Men (성인남성에서 현재 및 과거 흡연과 대사증후군의 관련성)

  • Hong, A-Rum;Lee, Kang-Sook;Lee, Seon-Young;Yu, Jae-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.3
    • /
    • pp.160-164
    • /
    • 2009
  • Objectives : The objective of this study was to determine the relationship between past smoking and the risk factors for metabolic syndrome. Methods : From January 2007 to December 2007, a total of 3,916 over thirty years old male health screen examinees were divided into the nonsmoking, smoking, ex-smoking groups. The diagnosis of metabolic syndrome was based on the criteria of the NCEP ATP III(Executive Summary of The Third Report of The National Cholesterol Education Program). Metabolic syndrome was defined as the presence of three or more of the following: a blood pressure $\geq$ 130/85 mmHg, a fasting glucose level $\geq$ 110 mg/dL, a HDL-C (High Density Lipoprotein Cholesterol) level < 40 mg/dL, a triglyceride level $\geq$ 150 mg/dL and, a waist circumference men $\geq$ 102 cm, but a waist to hip ratio > 0.90 was used as a surrogate for the waist circumference. Results : After adjustment for age, alcohol consumption and, exercise in the smokers, for the ex-smokers compared with the nonsmokers, the odds ratio (OR) of a lower HDL cholesterol level (<40 mg/dL) was 1.29 (95% CI=1.03-1.61) in the smokers, the ORs of a higher triglyceride level were 1.35 (95% CI=1.09-1.66) in the ex-smokers and, 2.12 (95% CI=1.75-2.57) in the smokers, and the OR of a waist to hip ratio was 1.25 (95% CI=1.03-1.52) in the ex-smokers. When there were over three components of metabolic syndrome in the ex-smokers and smokers as compared with the nonsmokers, the odds ratio against the risk of metabolic syndrome were 2.39 (95% CI=1.00-6.63) and 2.37 (95% CI=1.02-6.46), respectively. Conclusions : The present study suggested that there is an association of smoking with metabolic syndrome in men.

Optical properties and applications of $TiO_2$ films prepared by ion beam sputtering (이온빔 스퍼터링으로 증착한 $TiO_2$박막의 광학적 특성 및 응용)

  • 이정환;조준식;김동환;고석근
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.3
    • /
    • pp.176-182
    • /
    • 2002
  • Amorphous $TiO_2$ thin films were deposited on glass substrates by ion beam sputtering in which the ratio of $O_2$/Ar gas used as discharged gas was varied from 0 to 2. After optical and microstructure properties and chemical composition of thin films was analyzed, antireflection coating layers were fabricated with $SiO_2$/$TiO_2$ multi-layers. Thin films deposition was performed at room temperature and ion beam voltage and ion current density for sputtering of target were fixed at 1.2 kV and 200 $\mu\textrm{A}/\textrm{cm}^2$, respectively. Refractive indexs of the deposited $TiO_2$films were 2.40-2.45 at a wavelength of 633 nm. $TiO_2$films had high transmission and stoichiometry when ratio of $O_2$/Ar was 1. Rms roughness of deposited $TiO_2$ film was below 7 $\AA$. In excessive $O_2$ environments, however Rms roughness increased over 50 $\AA$. Transmittance decreased by scattering of rough surface. Reflectance of $SiO_2$/$TiO_2$multi-layers was below 1% in visible light.

Corrosion Characteristics of TiN/Ti Multilayer Coated Ti-30Ta-xZr Alloy for Biomaterials (TiN/Ti 다층막 코팅된 생체용 Ti-30Ta-xZr 합금의 부식특성)

  • Kim, Y.U.;Cho, J.Y.;Choe, H.C.
    • Corrosion Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.162-169
    • /
    • 2009
  • Pure titanium and its alloys are drastically used in implant materials due to their excellent mechanical properties, high corrosion resistance and good biocompatibility. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus than cortical bone. Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. For this reason, Ti-30Ta-xZr alloy systems have been studied in this study. The Ti-30Ta containing Zr(5, 10 and 15 wt%) were 10 times melted to improve chemical homogeneity by using a vacuum furnace and then homogenized for 24 hrs at $1000^{\circ}C$. The specimens were cut and polished for corrosion test and Ti coating and then coated with TiN, respectively, by using DC magnetron sputtering method. The analyses of coated surface were carried out by field emission scanning electron microscope(FE-SEM). The electrochemical characteristics were examined using potentiodynamic (- 1500 mV~+ 2000 mV) and AC impedance spectroscopy(100 kHz~10 mHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The equiaxed structure was changed to needle-like structure with increasing Zr content. The surface defects and structures were covered with TiN/Ti coated layer. From the polarization behavior in 0.9% NaCl solution, The corrosion current density of Ti-30Ta-xZr alloys decreased as Zr content increased, whereas, the corrosion potential of Ti-30Ta-xZr alloys increased as Zr content increased. The corrosion resistance of TiN/Ti-coated Ti-30Ta-xZr alloys were higher than that of the TiN-coated Ti-30Ta-xZr alloys. From the AC impedance in 0.9% NaCl solution, polarization resistance($R_p$) value of TiN/Ti coated Ti-30Ta-xZr alloys showed higher than that of TiN-coated Ti-30Ta-xZr alloys.

Tracking Recent Terrorism Trends in Europe and North America (최근 북미 및 유럽지역의 테러리즘 동향연구: 2012-2017)

  • Park, Gi-Bbeum;Lee, Chang-Han;Yu, Hyo-Eun
    • Korean Security Journal
    • /
    • no.53
    • /
    • pp.109-133
    • /
    • 2017
  • The purpose of this study is to provide a general trends in recent terrorism in North America and Europe over the last five years. In particular the terrorism which occurred after 2012 shows the transition in trends as terrorists attacks civilians and public places(soft target) rather than targeting national facilities or specific people. For instance, the Parris terror attack and Barcelona vehicle attack shows this changes clearly. The terrorists appeared to attack ordinary people in urban places with high population density. Although the trends are changing, there are still few studies focusing on the current situation, and most of the previous studies have focused on changing in strategies and counter-terrorism in each country after the 9.11 terror. Meanwhile, studies examining the trends of terrorism have been limited to analyzing few cases or using relatively monolithic data of Global Terrorism Data(GTD). While the types of terrorism that occur recent years including 'new terrorism' in many respects, it seems to be difficult to classify with GTD data and/or case studies. Therefore, it is necessary to construct new data that perhaps grasp the recent trend of terrorism from different perspectives. In this point of view, this Based on this, this study collects terrorism data from North America and Europe for the past five years, by using the National Intelligence Service's annual report on terrorism as a sampling framework and analyse the trends and changes. The result shows similarities in the methods of attack, and the type of weapon they used. As vehicle attacks has been raised in few years, damage area has been widen and casualties also have been increased.

  • PDF

Electrochemical Characteristics of Ru Added Li4Ti5O12 as an Anode Material (Ru를 첨가한 음극활물질 Li4Ti5O12의 전기화학적 특성)

  • Cho, Woo-Ram;Na, Byung-Ki
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.433-438
    • /
    • 2014
  • There is an increasing interest in the development of rechargeable batteries suitable for use in both hybrid electric vehicles and energy storage systems that require higher charge & discharge rates, bigger battery sizes and increased safety of the batteries. Spinel-type lithium titanium oxide ($Li_4Ti_5O_{12}$) as a potential anode for lithium ion batteries has many advantages. It is a zero-strain materials and it experiences no structural change during the charge/discharge precess. Thus, it has long cycle life due to its structural integrity. It also offers a stable operation voltage of approximately 1.55 V versus $Li^+/Li$, above the reduction potential of most organic electrolyte. In this study, Ru added $Li_4Ti_5O_{12}$ composites were synthesized by solid state process. The characteristics of active material were investigated with TGA-DTA, XRD, SEM and charge/discharge test. The capacity was reduced when Ru was added, however, the polarization decreased. The capacity rate of $Li_4Ti_5O_{12}$ with Ru (3%, 4%) addition was reduced during the charge/discharge precess with 10 C-rate as a high current density.

Development of numerical model for estimating thermal environment of underground power conduit considering characteristics of backfill materials (되메움재 특성을 고려한 전력구 열환경 변화 예측 수치해석모델 개발)

  • Kim, Gyeonghun;Park, Sangwoo;Kim, Min-Ju;Lee, Dae-Soo;Choi, Hangseok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.121-141
    • /
    • 2017
  • The thermal analysis of an underground power conduit for electrical cables is essential to determine their current capacity with an increasing number of demands for high-voltage underground cables. The temperature rises around a buried cable, caused by excessive heat dissipation, may increase considerably the thermal resistance of the cables, leading to the danger of "thermal runaway" or damaging to insulators. It is a key design factor to develop the mechanism on thermal behavior of backfilling materials for underground power conduits. With a full-scale field test, a numerical model was developed to estimate the temperature change as well as the thermal resistance existing between an underground power conduit and backfill materials. In comparison with the field test, the numerical model for analyzing thermal behavior depending on density, moisture content and soil constituents is verified by the one-year-long field measurement.