• Title/Summary/Keyword: hemoglobin

Search Result 2,140, Processing Time 0.025 seconds

Effect of Pretense (Subtilisin Carlsberg) on the Removal of Blood Protein Soil (I) -The Hydrolysis of Hemoglobin by Subtilisin Carlsberg- (Protease(Subtilisin Carlsberg)가 혈액 단백질 오구의 제거에 미치는 영향(I) -Subtilisin Carlsberg에 의한 헤모글로빈의 가수분해율-)

  • 이정숙;김성연
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.3
    • /
    • pp.550-559
    • /
    • 1996
  • The Effect of protease (subtilisin Carlsberg) on the removal of hemoglobin as protein soil was studied. The hydrolysis characteristics of subtilisin Carlsberg was examined by electrophoretic techniques. The fragmentation patterns of hemoglobin were analyzed by SDS-PAGE. The hydrolysis efficiency was evaluated by analysis of protein bands shown on gels before and after hydrolysis by using densitometer. 1. The hydrolysis of hemoglobin by subtilisin Carlsberg was increased markedly with the increase of the enzyme concentration. 2. The hydrolysis of hemoglobin by subtilisin Carlsberg was effectively increased in proportion to increasing of the hemoglobin concentration up to a certain point, but it began to decrease above the point. 3. The hydrolysis of hemoglobin by subtilisin Carlsberg followed the first order kinetics, yielding a rate constant of $4.05\time10^{-4}S^{-1}s$. 4. The hydrolysis of hemoglobin by subtilisin Carlsberg was highest at $50^{\circ}C$ and was decreased markedly at $80^{\circ}C$. 5. The hydrolysis of hemoglobin was comparatively low at pH 7.0~8.0, and highest at pH 11.0.

  • PDF

Effect of urea on blood-luminol chemiluminescence reaction (Urea가 혈액-luminol 화학발광에 미치는 영향)

  • Youngpyo Bae;Sungwook Hong
    • Analytical Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.332-339
    • /
    • 2023
  • This study aimed to verify the hypothesis that urea denatures hemoglobin in the blood, thereby exposing active sites of enzymes and enhancing the chemiluminescence of the blood-luminol reaction. When blood was pretreated with urea, higher concentrations of pretreatment urea or longer pretreatment times resulted in enhanced chemiluminescence in the blood-luminol reaction, supporting the above hypothesis. However, the chemiluminescence was enhanced when blood was treated with luminol mixed with an 8 M urea solution, although the fact that the time for urea to denature hemoglobin was shorter compared to when blood was pretreated with urea and followed by luminol. In addition, the chemiluminescence was enhanced when a transition metal without hemoglobin was reacted with urea-containing luminol. Based on these results, it is anticipated that urea not only denatures hemoglobin but also plays a role in the luminol-hydrogen peroxide reaction.

Biological monitoring of dye manufacturing workers by hemoglobin adducts (헤모글로빈 부가체를 이용한 염료제조 근로자의 노출평가)

  • Jhang, Kyuyeub;Lee, Keungjong;Kim, Chinyon;Yoon, youngshik;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.2
    • /
    • pp.124-139
    • /
    • 2000
  • This study was performed to investigate monoacetylbenzidine(MABZ) and benzidine(BZ) hemoglobin adducts among workers who worked at benzidine based dye manufacturing company, and exposed by benzidine and benzidine based dye. The hemoglobin adducts were compared with work environment assessment result for evaluating the usefulness of biological monitoring. The mean BZ hemoglobin adducts among the first synthesis worker's hemoglobin adducts were $40.69{\mu}gBZ/g$ Hb and those of dry and packing workers were $22.14{\mu}gBZ/g$ Hb. The mean of MABZ hemoglobin adducts among 1st synthesis workers were $255.84{\mu}gMABZ/g$ Hb, dispersion worker's hemoglobin adducts were $76.17{\mu}gMABZ/g$ Hb and synthesis worker's hemoglogin adducts were $28.66{\mu}gMABZ/g$ Hb. Work environment assessment results during past 3 years were $0.0065mg/m^3$ and $0.5659mg/m^3$ of benzidine based dye concentration in ambient air of drying and packing only. Dye producing process was categorized by the possibility of exposure to benzidine and benzidine based dye. BZ and MABZ hemoglobin adducts were $19.55{\mu}gBZ/g$ Hb, $119.80{\mu}gMABZ/g$ Hb among workers who exposed by benzidine dihydrochloride and $16.32{\mu}gBZ/g$ Hb, $316.56{\mu}gMABZ/g$ Hb among workers who exposed by benzidine based dye. BZ hemoglobin adducts were not detected among control group and MABZ hemoglobin adducts were $5.33{\mu}gMABZ/g$ Hb. The differences between control and other exposed group was statistically significant. But there was no statistically significant differences between benzidine dihydrochloride exposed process and benzidine based dye exposed group. BZ and MABZ hemoglobin adducts were $2.23{\mu}gBZ/g$ Hb, $76.17{\mu}gMABZ/g$ Hb and $3.46{\mu}gBZ/g$ Hb, $21.33{\mu}gMABZ/g$ Hb. So hemoglobin adducts of MABZ were 5 ~ 30 time higher than those of BZ(P<0.003). Above results indicate that work environment assessment didn't detected benzidine and benzidine based dye in ambient air but biological monitoring detected those of hemoglobin adducts. Two group's hemoglobin adducts exposed benzidine dihydrochloride and benzidine based dye were high level but wasn't statistically significant and those were not detected in control group.

  • PDF

Electrochemical Investigation of Bovine Hemoglobin at an Acetylene Black Paste Electrode in the Presence of Sodium Dodecyl Sulfate

  • Zhan, Guoqing;Li, Chunya;Luo, Dengbai
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.10
    • /
    • pp.1720-1724
    • /
    • 2007
  • Electrochemical behaviors of bovine hemoglobin (Hb) at an acetylene black paste electrode based on the enhancement effect of sodium dodecyl sulfate (SDS) were investigated. In the optimal conditions, a very weak reduction peak was observed at an acetylene black paste electrode for hemoglobin in the absence of SDS. However, the reduction peak current increased remarkably after the addition of 4.0 × 10?4 mol L?1 SDS, suggesting that SDS exhibits obvious enhancement effect to the determination of hemoglobin. All the experimental parameters, such as pH value, concentration of SDS, accumulation time and accumulation potential were optimized for hemoglobin analysis. The proposed method possesses high sensitivity (detection limit is 3.0 × 10?9 mol L?1), wide linearity (6.0 × 10?9 to 6.0 × 10?7 mol L?1), rapid response and low cost. Finally, the method was successfully employed to determine hemoglobin in a spiked sample.

Time relationship between the change of blood glucose concentration and the change of hemoglobin A1 concentration in experimentally induced diabetic dogs (실험적으로 당뇨병을 유발시킨 개에 있어서 혈당량과 Hemoglobin A1 농도의 변화의 시간적인 상관관계)

  • Lee, Chang-woo;Kim, Bonn-won
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.4
    • /
    • pp.946-956
    • /
    • 1998
  • Fifteen mongrel dogs (14 male and 1 female) were injected intravenously with 30mg of streptozotocin and 50mg of alloxan monohydrate per kilogram of body weight to induce diabetes mellitus. Before treatment with streptozotocin and alloxan fasting serum glucose concentration was determined every other day or thrice a week (Monday, Wednesday, Friday) for 3 months. Among 15 dogs 4 dogs developed diabetes mellitus and survived more than 9 weeks without injection of insulin. After treatment fasting serum glucose and hemoglobin $A_1$ concentrations of the 4 dogs were determined every other day or thrice a week. Fasting serum glucose concentration increased acutely from 24 hours after treatment and then showed severe fluctuation. Hemoglobin $A_1$ concentration increased gradually until 7~9 weeks after treatment and then showed very slow increase afterwards. Correlation of hemoglobin $A_1$ to fasting glucose concentration was relatively weak(r = 0.10~0.80). Hemoglobin $A_1$ and fasting glucose concentration of preceding 7 week showed very high correlation (r = 0.98~0.99). It was indicated that hemoglobin $A_1$ concentration in chemically induced diabetic dogs reflects mean glucose concentration of preceding 7~9 weeks.

  • PDF

Novel Detection Technology for Glycated Hemoglobin using Gold Nanoparticles (금 나노입자를 이용한 새로운 당화혈색소의 검출 기술)

  • Lee, Soo Suk
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.435-439
    • /
    • 2016
  • We report a novel detection technology for glycated hemoglobin (HbA1c) that is measured primarily to identify the three-month average plasma glucose concentration. In enzymatic measuring of glycated hemoglobin, the generated hydrogen peroxide was then used as a reducing agent of gold (III) for the synthesis of gold (0). Gold nanoparticles obtained from this novel approach were measured by optical and piezoelectric methods. In optical method, we have developed polymer based film-type sensor cartridge filled with all the reagents for glycated hemoglobin analysis and the cartridge worked very well having the detection limit of 0.53% of glycated hemoglobin. On the other hand, quartz crystal microbalance (QCM) sensors also have been developed to determine the abilities of surface modified QCM sensors at various levels of the concentration of glycated hemoglobin to bind gold nanoparticles and limit of detection was 0.90%. Finally, despite of relatively lower sensitivities of QCM sensor and film-type optical sensor than well-plate based optical detection, these two sensors were available to measure the glycated hemoglobin level for diabetes patients and normal person.

Studies on the Pharmacodynamic Action of Methemoglobin (Methemoglobind의 약력학적(藥力學的) 작용(作用)에 관(關)한 연구(硏究))

  • Kim, Kwang-Yun
    • The Korean Journal of Pharmacology
    • /
    • v.2 no.1 s.2
    • /
    • pp.49-69
    • /
    • 1966
  • For the purpose of stydying the pharmacodynamic action of methemoglobin, the author made the following experiments: 1. Preparation of hemoglobin and methemoglobin solutions: Red cell suspension from rabbit blood was hemolysed with distilled water and then divided into two portions. One portion was dialysed through cellophane paper and made isotonic with the proper amount of sodium chloride. The second portion was treated with sodium nitrite to convert hemoglobin to methemoglobin, dialysed through cellophane paper and made isotonic. 2. The concentration of methemoglobin in solution, plasma and urine was determined by Horecker and Brackette's method, and that of hemoglobin by the cyanmethemoglobin method. 3. The concentration of methemoglobin and hemoglobin in the plasma and urine of rabbits was measured at several intervals of time after infusion of the above samples. 4. The blood pressure and respiration of rabbits were recorded on a kymograph, and the effects of the samples on them were observed. 5. The effects of the samples on the movements of the in-situ heart and the isolated intestine of rabbits were studied. 6. The kidneys of rabbits were excised 4 to 5 hours after injection of the samples, and histopathological examinations were made. These experiments revealed the following results: 1. When methemoglobin solution was allowed to stand in room air, there was no decrease in the concentration of methemoglobin. 2. When methemoglobin solution was mixed with whole blood and incubated at $37^{\circ}C$, the concentration of methemoglobin decteased gradually. 3. After the infusion of methemoglobin and hemoglobin solutions, the rate of disappearance of methemoglobin in the plasma was more rapid than that of hemoglobin in the plasma. The higher the initial concentration in the plasma, the larger was the rate of disappearance of methemoglobin. 4. The rate of disappearance of methemoglobin was exceedingly rapid for 30 minutes after the infusion. 5. The urinary excretion of methemoglobin was more rapid than that of hemoglobin. 6. It would seem that the circulating blood contains substances which are promptly mobilized in the plasma to reduce methemoglobin to hemoglobin. 7. Moderate amounts of methemoglobin solution caused some rise in the blood pressure and a transient acceleration of the respiration of the rabbits. These effects of methemoglobin were milder than those of hemoglobin. 8. The movements of the in-situ heart and the isolated intestine of rabbits were accelerated by methemoglobin. These accelerating effects were milder than those of hemoglobin. 9. In the kidneys of rabbits treated with methemoglobin solution, hyperemia of the glomeruli, cloudy swelling and hemoglobin deposit in the tubular epithelium, hemoglobin casts in the tubular lumina of the proximal tubules, and interstitial congestion were constantly observed. There was no definite difference between the histological findings in the rabbit kidneys injected with methemoglobin, and those injected with hemoglobin solutions.

  • PDF

Removal of Hemoglobin from Acrylic Acid Grafted Nylon Fabric The Removal and the State of Adhesion of Hemoglobin on Grafted Nylon Fabric- (아크릴산 그라프트 중합한 나일론 직물의 헤모글로빈 오구 세척성 -그라프트 나일론 직물에 대한 헤모글로빈 부착상태와 세척성-)

  • 오수민;김인영;송화순
    • Textile Coloration and Finishing
    • /
    • v.11 no.3
    • /
    • pp.41-48
    • /
    • 1999
  • The removal of hemoglobin from acrylic acid grafted Nylon fabrics has been investigated. In order to change detergency of Nylon 6 fabric, acrylic acid(AA) were graft copolymerized on Nylon fabric using ammonium persulfate(APS) as a initiator, and then acrylic acid grafted Nylon was treated with NaOH solution. The graft ratio increased linearly with increasing acrylic acid concentration. The graft ratio was the highest when the concentration of APS was 0.05%, and it decreased as the concentration of APS increased. The surface of Nylon fabric became rough due to graft. Moisture regain was increased by graft and alkaline treatment, contact angle was also improved compared with the ungrafted. The hemoglobin was easily solubilized and removed from grafted Nylon fabric, while it was difficult to remove hemoglobin from ungrafted Nylon fabric. The effects of graft on removal of hemoglobin was related with increase of moisture regain and transformation of COOH to COONa by alkaline treatment.

  • PDF

Prognostic Significance of CYFRA21-1, CEA and Hemoglobin in Patients with Esophageal Squamous Cancer Undergoing Concurrent Chemoradiotherapy

  • Zhang, Hai-Qin;Wang, Ren-Ben;Yan, Hong-Jiang;Zhao, Wei;Zhu, Kun-Li;Jiang, Shu-Mei;Hu, Xi-Gang;Yu, Jin-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.1
    • /
    • pp.199-203
    • /
    • 2012
  • Purpose: To evaluate the prognostic value of serum CYFRA21-1, CEA and hemoglobin levels regarding long-term survival of patients with esophageal squamous cell carcinoma (ESCC) treated with concurrent chemoradiotherapy (CRT). Methods: Age, gender, Karnofsky Performance Status (KPS), tumor location, tumor length, T stage, N stage and serum hemoglobin, and CYFRA21-1 and CEA levels before concurrent CRT were retrospectively investigated and related to outcome in 113 patients receiving 5-fluorouracil and cisplatin combined with radiotherapy for ESCC. The Kaplan-Meier method was used to analyze prognosis, the log-rank to compare groups, the Cox proportional hazards model for multivariate analysis, and ROC curve analysis for assessment of predictive performance of biologic markers. Results: The median survival time was 20.1 months and the 1-, 2-, 3-, 5- year overall survival rates were 66.4%, 43.4%, 31.9% and 15.0%, respectively. Univariate analysis showed that factors associated with prognosis were KPS, tumor length, T-stage, N-stage, hemoglobin, CYFRA21-1 and CEA level. Multivariate analysis showed T-stage, N-stage, hemoglobin, CYFRA21-1 and CEA level were independent predictors of prognosis. By ROC curve, CYFRA21-1 and hemoglobin showed better predictive performance for OS than CEA (AUC= 0.791, 0.704, 0.545; P=0.000, 0.000, 0.409). Conclusions: Of all clinicopathological and molecular factors, T stage, N stage, hemoglobin, CYFRA21-1 and CEA level were independent predictors of prognosis for patients with ESCC treated with concurrent CRT. Among biomarkers, CYFRA21-1 and hemoglobin may have a better predictive potential than CEA for long-term outcomes.

Effectiveness of zinc protoporphyrin/heme ratio for screening iron deficiency in preschool-aged children

  • Yu, Kyeong-Hee
    • Nutrition Research and Practice
    • /
    • v.5 no.1
    • /
    • pp.40-45
    • /
    • 2011
  • Hemoglobin and zinc protoporphyrin (ZPP) tests are commonly used to screen for iron deficiency, but little research has been done to systematically evaluate the sensitivity and specificity of these two tests. The goal of this study was to evaluate the effectiveness of zinc protoporphyrin/heme (ZPP/H) ratio as a point-of-service screening test for iron deficiency among preschool-aged children by comparing the sensitivity and specificity of hemoglobin, ZPP/H ratio, and serum ferritin (SF). Also completed were assessments for the prevalence of anemia, iron deficiency (ID), and iron deficiency anemia (IDA) with indicators of ferritin models. This study was carried out with 95 children ages 3 to 6 y. Anthropometric measurements were assessed and blood samples were analyzed for hemoglobin, SF, transferrin saturation (TS), and ZPP. Anemia was common and the prevalences of anemia, ID, and IDA were 14.7%, 12.6%, and 5.2%, respectively. The ZPP/H ratio was strongly and significantly correlated with hemoglobin. And ZPP/H ratio was a more sensitive test for ID than hemoglobin or SF measurement, correctly identifying more than twice as many iron-deficient children (sensitivity of 91.7%, compared to 41.7% for hemoglobin and SF). However, ZPP/H ratio had lower specificity (60.2%, compared to 89.1% for hemoglobin or 96.4% for SF) and resulted in the false identification of more subjects who actually were not iron deficient than did hemoglobin or SF. Low hemoglobin concentration is a late-stage indicator of ID, but ZPP/H ratio can detect ID at early stages and can be performed easily at a relatively low cost. Therefore, ZPP/H ratio can serve as a potential screening test for pre-anemic iron deficiency in community pediatric practices.