• Title/Summary/Keyword: hemodynamic parameters

Search Result 122, Processing Time 0.026 seconds

Fermented ginseng, GBCK25, ameliorates hemodynamic function on experimentally induced myocardial injury

  • Aravinthan, Adithan;Antonisamy, Paulrayer;Kim, Bumseok;Kim, Nam Soo;Shin, Dong Gyu;Seo, Jeong Hun;Kim, Jong-Hoon
    • Journal of Ginseng Research
    • /
    • v.40 no.4
    • /
    • pp.462-465
    • /
    • 2016
  • In the present study, we investigated whether treatment with GBCK25 facilitated the recovery of hemodynamic parameters, left ventricle systolic pressure, left ventricular developed pressure, and electrocardiographic changes. GBCK25 significantly prevented the decrease in hemodynamic parameters and ameliorated the electrocardiographic abnormality. These results indicate that GBCK25 has distinct cardioprotective effects in rat heart.

A Review on Impedance Cardiography and Its Oriental Medical Application (한의학적 활용을 위한 임피던스 심장기록법의 연구동향)

  • Ko, Young-Il;Lee, Hyon-Soo;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.2
    • /
    • pp.67-78
    • /
    • 2006
  • Objectives : To review the method, validity and reliability of Impedance Cardiography and to study its oriental medical application. Method : The papers reviewed in this study were searched through internet search engines such as Springer, Science Direct, and China National Knowledge Infrastructure. Conclusion : In this study, the methodological limitations, validity and reliability of impedance cardiography were examined. Impedance Cardiography is recognized as a highly accurate non-invasive tool to assess hemodynamic parameters. The ability of impedance cardiography to assess hemodynamic parameters in non-invasive way is very suitable for researches on the effect of oriental medical therapeutics or the validation of oriental medical diagnostic.

  • PDF

Effect of Supratentorial Stroke on Cerebellar Hemodynamic Parameters - Assessment by Dynamic Susceptibility Contrast MR Imaging (천막상부 뇌졸중에서 소뇌의 혈역학 변화 -Dynamic Susceptibility Contrast MR 영상을 이용한-)

  • Han, Si-Ryung;Kim, Bum-Soo;Guak, Tae-Ho;Choi, Young-Bin;Kim, Yeong-In
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.1
    • /
    • pp.38-43
    • /
    • 2002
  • Background & Purpose : Dynamic susceptibility contrast MR imaging, one method of perfusion MRI, was developed to define cerebral hemodynamic status with good anatomical resolution. The authors investigated hemodynamic parameters using this imaging method, in an effort to identify hemodynamic changes on the remote crossed cerebellum of patients with a supratentorial infarct. Methods : Dynamic susceptibility contrast MR imaging was performed in 15 patients with only unilateral supratentorial infarcts. Imaging was obtained at the anatomic level of the cerebellum. rCBF, rCBV, MTT and TP were determined over both cerebellar hemispheres of interest. Results : The rCBF and rCBV values of the contralateral cerebellar hemisphere were significantly more decreased than those of the ipsilateral cerebellar hemisphere in 12 patients(p=0.028, 0.033). MTT and TP values of the contralateral and ipsilateral cerebellar hemispheres didn't reveal any differences(p=0.130, 0.121). Conclusions : The results of this work suggest that the region which are remote from the ischemic brain lesion shows no changes of MTT or TP but show decrease of rCBF and rCBV, mean to diaschisis, it also demonstrates that perfusion MRI is an easily available method to evaluate the hemodynamic status of the brain.

  • PDF

Development of Image Post-processing System for the Cerebral Perfusion Information Mapping of MR Image (MR영상의 뇌관류 정보 Mapping을 위한 영상후처리 시스템개발)

  • 이상민;강경훈;장두봉;김광열;김영일;신태민
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.131-138
    • /
    • 2000
  • This paper works on development of an algorithm for mapping of cerebral perfusion parameters using the gamma-variate curve fitting. The signal intensity variate curve according to time measured in each pixel of perfusion MRI is nonlinear, and various hemodynamic parameters are not computed accurately. Levenberg-Marquardt algorithm(LMA), nonlinear optimum algorithm with high convergent speed and stability, is used to compute them. That is, the signal intensity variate curve is fitted by the gamma-variate function. Various hemodynamic parameters - Cerebral Blood Volume(C.B.V), Mean Transit Time(M.T.T), Cerebral Blood Flow(C.B.F), Time-to-Peak(T.T.P), Bolus Arrival Time(B.A.T), Maximum Slope(M.S) - are computed using LMA.

  • PDF

Morphological and Hemodynamic Parameters for Middle Cerebral Artery Bifurcation Aneurysm Rupture Risk Assessment

  • Qin, Hao;Yang, Qixia;Zhuang, Qiang;Long, Jianwu;Yang, Fan;Zhang, Hongqi
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.504-510
    • /
    • 2017
  • Objective : To investigate the morphological and hemodynamic parameters associated with middle cerebral artery (MCA) bifurcation aneurysm rupture. Methods : A retrospective study of 67 consecutive patients was carried out based on 3D digital subtraction angiography data. Morphological and hemodynamic parameters including aneurysm size parameters (dome width, height, and perpendicular height), longest dimension from the aneurysm neck to the dome tip, neck width, aneurysm area, aspect ratio, Longest dimension from the aneurysm neck to the dome tip (Dmax) to dome width, and height-width, Bottleneck factor, as well as wall shear stress (WSS), low WSS area (LSA), percentage of LSA (LSA%) and energy loss (EL) were estimated. Parameters between ruptured and un-ruptured groups were analyzed. Receiver operating characteristics were generated to check prediction performance of all significant variables. Results : Sixty-seven patients with MCA bifurcation aneurysm were included (31 unruptured, 36 ruptured). Dmax (p=0.008) was greater in ruptured group than that in un-ruptured group. D/W (p<0.001) and the percentage of the low WSS area ($0.09{\pm}0.13$ vs. $0.01{\pm}0.03$, p<0.001) were also greater in the ruptured group. Moreover, the EL in ruptured group was higher than that in unruptured group ($6.39{\pm}5.04$ vs. $1.53{\pm}0.86$, p<0.001). Multivariate regression analysis suggested D/W and EL were significant predictors of rupture of MCA bifurcation aneurysms. Correlation analyses revealed the D/W value was positively associated with the EL (R=0.442, p<0.01). Conclusion : D/W and EL might be the most two favorable factors to predict rupture risk of MCA bifurcation aneurysms.

Hemodynamic effects of Chunwangbosim-dan - A 3-dimensional radial pulse tonometry device study (3차원 맥영상 검사로 살펴본 천왕보심단이 심혈관계에 미치는 영향)

  • HeeJung KANG;YoungSang KUN;Tae Hun KU;Gyeung Cheul KIM
    • Journal of Convergence Korean Medicine
    • /
    • v.6 no.1
    • /
    • pp.5-20
    • /
    • 2024
  • Objectives: This study was aimed to evaluate the hemodynamic feasibility using pulse parameters as a way to establish safe dose guidelines for Chunwangbosim-dan, and to provide a foundation for developing evidence-based guidelines for clinical use. Methods: Forty-one volunteers were recruited to participate in a study examining the changes in pulse wave characteristics following the ingestion of Chunwangbosim-dan, over a period of 2 weeks, and pulse wave measurements were taken before and after the administration. Pulse wave parameters were measured in this study using a 3-dimensional radial pulse tonometry device(DMP-Lifeplus). In addition, questionnaire, blood pressure, temperature, and body composition were also measured as secondary measures. Results: Fifteen minutes after administration of Chunwangbosim-dan, the non-adverse event group(non-AE) exhibited a statistically significant increase in several power and pressure-related parameters, including h1, h3, h4, h5, SA, PA and PW, while the adverse event group(AE) showed a trend of decreasing stroke volume and increasing Systemic Vascular Resistance Index(SVRI) and applied pressure. After 2 weeks of administration, non-adverse event group(non-AE) exhibited significant changes in standard deviation of pulse rate and HRV_LH ratio. Notably, there are significant differences between AE group and non-AE group in h4/h1, w/t, applied pressure, SV and pulse rate. Conclusion: These findings suggest that pulse parameters may be a useful way to establish safe dosing guidelines for Chunwangbosim-dan. Further research is needed to confirm these results and to develop evidence-based guidelines for clinical use.

  • PDF

Optical imaging of epileptic activity and epilepsy treatments in neocortex

  • Suh, Min-Ah
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.427-428
    • /
    • 2009
  • Optical imaging offers excellent spatio-temporal sensitivity that is unparalleled by any other perfusion based imaging techniques. We used in vivo optical recording of intrinsic signals (ORIS) to map neurovascular hemodynamics of perfusion, oximetry and membrane potential during epileptic events in rat and mouse neocortex. Studies of hemodynamic changes with ORIS alone were also performed in human. Laboratory studies in rodent epilepsy models have demonstrated a persistent increase in deoxygenated hemoglobin (Hbr) and a decrease in tissue oxygenation during interictal spikes and ictal events. This "epileptic dip", like the "initial dip" recorded during normal sensory processing, implies that the enormous rise in cerebral blood flow (CBF) is inadequate to meet the increased metabolic demands associated with synchronized epileptic activity. These findings are critically important to the interpretation of the perfusion-based imaging studies, such as fMRI. In addition, we visualized the effect of direct cortical electrical stimulation, an alterative epilepsy treatment. The optical data following direct cortical electrical stimulation showed that hemodynamic signals are sensitive to different electrical stimulation parameters. Furthermore, our recent data demonstrated that the application of unilateral electrical stimulation is able to elicit bilateral hemodynamic responses in rat neocortex.

  • PDF

Hemodynamic Characteristics Affecting Restenosis after Percutaneous Transluminal Coronary Angioplasty with Stenting in the Angulated Coronary Stenosis

  • Lee, Byoung-Kwon;Kwon, Hyuck-Moon;Roh, Hyung-Woon;Cho, Min-Tae;Suh, Sang-Ho
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.13-23
    • /
    • 2003
  • Backgrounds: The present study in angulated coronary stenosis was to evaluate the influence of velocity and wall shear stress (WSS) on coronary atherosclerosis, the changes of hemodynamic indices following coronary stenting, as well as their effect of evolving in-stent restenosis using human in vivo hemodynamic parameters and computed simulation quantitatively and qualitatively. Methods: Initial and follow-up coronary angiographies in the patients with angulated coronary stenosis were performed (n=80). Optimal coronary stenting in angulated coronary stenosis had two models: < 50 % angle changed(model 1, n=43), > 50% angle changed group (model 2, n=37) according to percent change of vascular angle between pre- and post-intracoronary stenting. Flow-velocity wave obtained from in vivo intracoronary Doppler study data was used for in vitro numerical simulation. Spatial and temporal patterns of velocity vector and recirculation area were drawn throughout the selected segment of coronary models. WSS of pre/post-intracoronary stenting were calculated from three-dimensional computer simulation. Results: Follow-up coronary angiogram demonstrated significant difference in the percent of diameter stenosis between two groups (group 1: $40.3{\pm}30.2$ vs. group 2: $25.5{\pm}22.5%$, p<0.05). Negative WSS area on 3D simulation, which is consistent with re-circulation area of velocity vector, was noted on the inner wall of post-stenotic area before stenting. The negative WSS was disappeared after stenting. High spatial and temporal WSS before stenting fell into within physiologic WSS after stenting. This finding was prominent in Model 2 (p<0.01) Conclusions: The present study suggests that hemodynamic forces exerted by pulsatile coronary circulation termed as WSS might affect on the evolution of atherosclerosis within the angulated vascular curvature. Moreover, geometric change, such as angular difference between pre / post-intracoronary stenting might give proper information of optimal hemodynamic charateristics for vascular repair after stenting.

  • PDF

Changes of Hemodynamic Characteristics during Angulated Stenting in the Stenosed Coronary (관상동맥 협착부에 각이진 스텐트 시술시 혈류역학적 특성변화)

  • Suh Sang-Ho;Cho Min-Tae;Kwon Hyuck-Moon;Lee Byung-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.717-720
    • /
    • 2002
  • The present study is to evaluate the performances of flow velocity and wall shear stress in the stenosed coronary artery using human in vivo hemodynamic Parameters and computer simulation. Initial and follow-up coronary angiographics in the patients with angulated coronary stenosis are performed. Follow-up coronary angiogram demonstrated significant difference in the percent of diameter in the stenosed coronary between two groups ($Group\;1:\;40.3{\%},\;Group\;2:\;25.5{\%}$). Flow-velocity wave obtained from in vivo intracoronary Doppler ultrasound data is used for the boundary condition for the computer simulation. Spatial and temporal variations of flow velocity vector and recirculation area are drawn throughout the selected segment of coronary models. The WSS of pre- and post-intracoronary stenting are calculated from three-dimensional computer simulation. Then negative shear stresses area on 3D simulation we noted on the inner wall of the post-stenotic area before stenting. The negative WSS is disappeared after stenting. High spatial and temporal WSS before stenting fell into within physiologic WSS after stenting. This finding was prominent in Model 2. The present study suggest that hemodynamic forces exerted by pulsatile coronary circulation termed WSS might affect on the evolution of atherosclerosis within the angulated vascular curvature. The local recirculation area which has low or negative WSS, might lead to progression of atherosclerosis.

  • PDF

Hemodynamic, Autonomic, and Vascular Function Changes after Sleep Deprivation for 24, 28, and 32 Hours in Healthy Men

  • Slomko, Joanna;Zawadka-Kunikowska, Monika;Kozakiewicz, Mariusz;Klawe, Jacek J.;Tafil-Klawe, Malgorzata;Newton, Julia L.;Zalewski, Pawel
    • Yonsei Medical Journal
    • /
    • v.59 no.9
    • /
    • pp.1138-1142
    • /
    • 2018
  • This study aimed to analyze the impact of sleep deprivation (SD) on cardiac, hemodynamic, and endothelial parameters and to determine whether these are sustained with increased periods of SD. The study included 60 healthy men (mean: age $31.2{\pm}6.3years$; body mass index $24.6{\pm}2.6kg/m^2$). Hemodynamic parameters, parameters of myocardial contractility, spectral analysis of heart rate (HR) and blood pressure (BP) variability, and the sensitivity of arterial baroreflex function were evaluated. Biochemical tests were performed to assess L-arginine (L-Arg) and asymmetric dimethylarginine (ADMA) levels in reflection of endothelial nitric oxide synthase ability. Measurements of cardiovascular system parameters were obtained at 9 a.m. (baseline) on the first day of the study and 9 a.m. (24-h SD), 1 p.m. (28-h SD), and 5 p.m. (32-h SD) on the second day. Blood samples for evaluating biochemical parameters were obtained at baseline and after 24-h SD. ANOVA Friedman's test revealed a significant effect for time in relation to HR (${\chi}^2=26.04$, df=5, p=0.000), systolic BP (${\chi}^2=35.98$, df=5, p=0.000), diastolic BP (${\chi}^2=18.01$, df=5, p=0.003), and mean BP (${\chi}^2=28.32$, df=5, p=0.000). L-Arg and ADMA levels changed from $78.2{\pm}12.9$ and $0.3{\pm}0.1$ at baseline to $68.8{\pm}10.2$ and $0.4{\pm}0.1$ after 24-hr SD, respectively (p=0.001, p=0.004). SD in healthy men is associated with increases in BP, which appear to occur after 24 hours of SD and are maintained over increasing periods of SD. The observed hemodynamic changes may have resulted due to disordered vascular endothelial function, as reflected in alterations in L-Arg and ADMA levels.