• 제목/요약/키워드: helium partial pressure

검색결과 10건 처리시간 0.017초

확산동기 증발에 의한 극저온 액체 과냉각 (Subcooling of cryogenic liquid by diffusion-driven evaporation)

  • 조남경;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.72-82
    • /
    • 2007
  • This paper relates to reducing the temperature of a cryogenic liquid by contacting it with gas bubbles, which can be characterized by diffusion-driven evaporative cooling, The characteristic of diffusion-driven evaporative cooling is thoroughly examined by theoretical. analytical and experimental methods specifically for the case of helium injection into liquid oxygen. The results reveal that if the gaseous oxygen partial pressure in helium bubbles is lower than the liquid oxygen vapor pressure, cooling occurs autonomously due to diffusion mass transfer. The method of lowering the injected helium temperature turns out to be very effective for cooling purpose.

헬륨가스 냉각 고온초전도 케이블의 절연특성 평가 시스템 개발 및 성능평가 (Development and Test results of the Dielectric Evaluation System for a Helium Gas Cooled HTS Cable)

  • 곽동순
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권1호
    • /
    • pp.25-29
    • /
    • 2012
  • The novel type of cable under consideration is cooled by gaseous Helium at elevated pressure. Helium is known for having poor electric breakdown strength; therefore the dielectric capabilities of this type of cable must be tested under conditions similar to the envisaged operation. In order to study the dielectric performance we have designed and built a novel high pressure cryostat rated at 2.17 MPa which has been used for testing model cables of lengths of up to 1 m. The cryostat is an open system where the gas is not re-circulated. This allows maintaining a high purity of the gas. The target temperature range is between 40 K and 70 K. This substantially increases the critical current density of the HTS compared to 77 K, which is the typical temperature of cables cooled by liquid nitrogen. The cryostat presented allows for adjusting the temperature and keeping it constant for the time necessary to run a complete dielectric characterization test. We give a detailed description of the cryostat. Measurements of partial discharge inception voltages as well as the temperature distribution along the model cables as a function of time are presented.

Evaluation Method on Destruction and Removal Efficiency of Perfluorocompounds from Semiconductor and Display Manufacturing

  • Lee, Jee-Yon;Lee, Jin-Bok;Moon, Dong-Min;Souk, Jun-Hyung;Lee, Seung-Yeon;Kim, Jin-Seog
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권8호
    • /
    • pp.1383-1388
    • /
    • 2007
  • Recently, the semiconductor and display industries have tried to reduce the emissions of perfluorocompounds (PFCs) from the globally environmental regulation. Total amount of PFC emission can be calculated from the flow rate and the partial pressures of PFCs. For the precise measurement of PFC emission amount, the mass flow controlled helium gas was continuously injected into the equipment of which scrubber efficiency is being measured. The partial pressures of PFCs and helium were accurately measured using a mass spectrometer in each sample extracted from inlet and outlet of the scrubber system. The flow rates are calculated from the partial pressures of helium and also, PFC destruction and removal efficiency (DRE) of the scrubber is calculated from the partial pressure of PFC and the flow rate. Under this method, the relative expanded uncertainties of the flow rate and the partial pressures of PFCs are ± 2% (k = 2) in case the concentrations of NF3 and SF6 are as low as 100 μmol/mol.

대형 진공용기의 헬륨 누설검사 방법에 대한 고찰 (Consideration on the helium leak detection in a large vacuum chamber)

  • 인상렬
    • 한국진공학회지
    • /
    • 제16권4호
    • /
    • pp.235-243
    • /
    • 2007
  • 지금 국내에서는 토카막 핵융합실험장치, 대전류 중성입자빔 실험장치 및 우주 모의실험실 같은 거대시설의 건설과 운용이 활발하다. 이런 시설의 핵심설비인 대형 진공용기는 중소형 용기에 비해 누설 가능성은 높은 반면 기체누설을 검사하는 것은 까다롭다. 중소형 용기에서 널리 사용되는 헬륨누설검사 방법을 어떻게 효율적으로 이런 대형 용기에 적용할 수 있는가 알아보기 위해, 다양한 가상적인 누설검사 시스템들을 구성하고 압력분포 및 헬륨 분압을 계산하여 주어진 장치조건에서 적절한 검사 시스템을 찾는 방법에 대해 논한다.

Pressure-volume-temperature gauging method experiment using liquid nitrogen under microgravity condition of parabolic flight

  • Seo, Mansu;Park, Hana;Yoo, DonGyu;Jung, Youngsuk;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권2호
    • /
    • pp.64-69
    • /
    • 2014
  • Measuring an exact amount of remaining cryogenic liquid propellant under microgravity condition is one of the important issues of rocket vehicle. A Pressure-Volume-Temperature (PVT) gauging method is attractive due to its minimal additional hardware and simple gauging process. In this paper, PVT gauging method using liquid nitrogen is investigated under microgravity condition with parabolic flight. A 9.2 litre metal cryogenic liquid storage tank containing approximately 30% of liquid nitrogen is pressurized by ambient temperature helium gas. During microgravity condition, the inside of the liquid tank becomes near-isothermal condition within 1 K difference indicated by 6 silicon diode sensors vertically distributed in the middle of the liquid tank. Helium injection with higher mass flow rate after 10 seconds of the waiting time results in successful measurements of helium partial pressure in the tank. Average liquid volume measurement error is within 11% of the whole liquid tank volume and standard deviation of errors is 11.9. As a result, the applicability of PVT gauging method to liquid propellant stored in space is proven with good measurement accuracy.

950℃ 불순물을 포함한 헬륨 환경에서 CVD β-SiC의 산화 (Oxidation of CVD β-SiC in Impurity-Controlled Helium Environment at 950℃)

  • 김대종;김원주;장지은;윤순길;김동진;박지연
    • 한국세라믹학회지
    • /
    • 제48권5호
    • /
    • pp.426-432
    • /
    • 2011
  • The oxidation behavior of CVD ${\beta}$-SiC was investigated for Very High Temperature Gas-Cooled Reactor (VHTR) applications. This study focused on the surface analysis of the oxidized CVD ${\beta}$-SiC to observe the effect of impurity gases on active/passive oxidation. Oxidation test was carried out at $950^{\circ}C$ in the impurity-controlled helium environment that contained $H_2$, $H_2O$, CO, and $CH_4$ in order to simulate VHTR coolant chemistry. For 250 h of exposure to the helium, weight changes were barely measurable when $H_2O$ in the bulk gas was carefully controlled between 0.02 and 0.1 Pa. Surface morphology also did not change based on AFM observation. However, XPS analysis results indicated that a very small amount of $SiO_2$ was formed by the reaction of SiC with $H_2O$ at the initial stage of oxidation when $H_2O$ partial pressure in the CVD ${\beta}$-SiC surface placed on the passive oxidation region. As the oxidation progressed, $H_2O$ consumed and its partial pressure in the surface decreased to the active/passive oxidation transition region. At the steady state, more oxidation did not observable up to 250 h of exposure.

니켈기 합금 Alloy 617의 950℃ 대기/헬륨 분위기에서 산화거동 고찰 (Investigation of Oxidation Behavior of Alloy 617 under Air/Helium Environments at 950℃)

  • 정수진;이경근;김동진
    • Corrosion Science and Technology
    • /
    • 제17권5호
    • /
    • pp.218-224
    • /
    • 2018
  • Alloy 617 is a candidate Ni-based superalloy for intermediate heat exchanger (IHX) of a high-temperature gas reactor (VHTR), because of its good creep strength and corrosion resistance at high temperature. Small amount of impurities such as $H_2O$, $H_2$, CO and $CH_4$ are introduced inevitably in helium, as a coolant during operation of a VHTR. Reactions of material and impurities are accelerated with increase of temperature to $950^{\circ}C$ of operating temperature of a VHTR, leading to material corrosion aggravation. In this circumstance, high-temperature corrosion tests were performed at $950^{\circ}C$ in air and impure helium environments, up to 250 hours in this study. Oxidation rate of $950^{\circ}C$ in an air environment was higher than that of impure helium, explained by difference in outer oxide morphology and microstructure as a function of oxygen partial pressure. An equiaxed Cr-rich surface oxide layer was formed in an air environment, and a columnar Cr-rich oxide was formed in an impure helium environment.

산소 농도에 따른 Alloy 617의 고온헬륨환경에서의 크립 및 산화거동 (Creep and Oxidation Behaviors of Alloy 617 in High Temperature Helium Environments with Various Oxygen Concentrations)

  • 구자현;김대종;장창희
    • 한국압력기기공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.34-41
    • /
    • 2011
  • Wrought nickel-base superalloys are being considered as the structural materials in very-high temperature gas-cooled reactors. To understand the effects of impurities, especially oxygen, in helium coolant on the mechanical properties of Alloy 617, creep tests were performed in high temperature flowing He environments with varying $O_2$ contents at 800, 900, and $1000^{\circ}C$. Also, creep life in static He was measured to simulate the pseudo-inert environment. Creep life was the longest in static He, while the shortest in flowing helium. In static He, impurities like $O_2$ and moisture were quickly consumed by oxidation in the early stage of creep test, which prevented further oxidation during creep test. Without oxidation, microstructural change detrimental to creep such as decarburization and internal oxidation were prevented, which resulted in longer creep life. On the other hand, in flowing He environment, surface oxides were not stable enough to act as diffusion barriers for oxidation. Therefore, extensive decarburization and internal oxidation under tensile load contributed to premature failure resulting in short creep life. Limited test in flowing He+200ppm $O_2$ resulted in even shorter creep life. The oxidation samples showed extensive spallation which resulted in severe decarburization and internal oxidation in those environments. Further test and analysis are underway to clarify the relationship between oxidation and creep resistance.

Study of Counter Diffusion in Isostatic Permeameters

  • Bianchi, F.;Pegoraro, M.;Zanderighi, L.
    • Korean Membrane Journal
    • /
    • 제3권1호
    • /
    • pp.39-50
    • /
    • 2001
  • The counter-diffusion of two gaseous substances permeating a polymeric membrane has been investigated both experimentally and theoretically. The aim of the study was to find mutual effects, if any, that could influence the permeability and diffusivity data. The experimental data were obtained with an isostatic permeameter operating at ambient pressure and 303 K: helium, nitrogen, carbon dioxide methane were used as permeating gas at different partial pressure; helium or nitrogen as equilibrating or carrier gas. No evident mutual effect of the counter-diffusing gas was observed. The theoretical analysis gave some insight into the phenomena and it was concluded that at near-atmospheric pressures, and in the absence of swelling phenomena no mutual interaction exists. On a theoretical basis any mutual interaction between diffusing and counter-diffusing gases could only occur: i) at high pressures , when the free movement of permeating gas molecules within the polymer is hindered by the counter-diffusing gas; ii) when a large part of the free volume fraction is occupied by the counter--diffusing gas; iii) swelling phenomena modify the structure and free volume fraction of the polymer.

  • PDF

Experimental Study on the Interference of Water Vapor on the Chemical Ionization of OH by Sulfur Hexafluoride Ion

  • Park, Jong-Ho
    • Mass Spectrometry Letters
    • /
    • 제5권4호
    • /
    • pp.120-123
    • /
    • 2014
  • The interference of water vapor on the chemical ionization (CI) of hydroxyl radicals (OH) by sulfur hexafluoride ion ($SF_6{^-}$) was investigated using a flow tube system coupled to a high-pressure CI mass spectrometer. Water vapor, which is required to study heterogeneous reactions of OH under real tropospheric conditions, transforms the reagent ion $SF_6{^-}$ into $SF_4O^-$ and $F^-(HF)_n$, resulting in a substantial loss in CI sensitivity. Therefore, under humid conditions, peaks corresponding to OH are drastically diminished, while those corresponding to OH-water complex ions ($[OH(H_2O)_n]^-$) are enhanced. $[OH(H_2O)_3]^-$ was observed as the major OH species. The obsercation of $[OH(H_2O)_n]^-$ by isolating humid conditions to the CI region and preliminary ab initio calculations suggested that $[OH(H_2O)_n]^-$ ions were produced from reactions between OH ions ($OH^-$) and water molecules. An additional helium buffer flow introduced into the CI region reduced loss of the reagent ion and resulted in a partial recovery of OH peak intensities under humid conditions.