• Title/Summary/Keyword: height measurements

Search Result 1,383, Processing Time 0.031 seconds

Measurements of Microwave Polarimetric Backscattering from a Wet Soil Surface and Comparison with a Semi-empirical Scattering Model

  • Oh, Yi-Sok
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.154-157
    • /
    • 1999
  • Microwave polarimetric backscattering from a wet soil surface had been measured using a Ku-band polarimetric scatterometer at the incidence angles ranging from 10$^{\circ}$ to 70$^{\circ}$ Since the accurate target parameters as well as the radar parameters are necessary for radar scattering modeling, a complete and accurate set of ground truth data were also collected, from which accurate measurements were made of the rms height, correlation length, and dielectric constant. The measured polarimetric backscattering coefficients (vv-, hh-, vh-, hv-polarizations) were compared with theoretical models and empirical models. A new semi-empirical model for microwave polarimetric radar backscattering from bare soil surfaces was developed using polarimetric radar measurements and the knowledge based on the theoretical and numerical solutions. The model was found to yield very good agreement with the backscattering measurements of this study.

  • PDF

A LATERAL CEPHALOMETRIC STUDY OF 10-YEAR-OLD CHILDREN WITH NORMAL OCCLUSION (10세 정상교합 아동의 측모두부방사선 계측학적 연구)

  • Ju, Chan-Hee;Kim, Seon-Mi;Yang, Kyu-Ho;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.280-290
    • /
    • 2012
  • This study was performed to establish the lateral cephalometric standards of Korean children for diagnosis of antero-posterior and vertical discrepancies of maxillofacial region. The lateral cephalometric radiographs were taken from 100 Korean children with normal occlusion, and then 15 measurements were statistically analysed. The results of this study were as follows : 1. Maxillary length of males was significantly greater than that of females (p < 0.05). There was strong correlation between maxillary and mandibular length (r = 0.625(M), 0.574(F)). 2. Lower facial height of males was significantly greater than that of females (p < 0.05). Furthermore, there was strong correlation between total facial height and upper facial height (r = 0.405(M), 0.417(F)) and very strong correlation between total facial height and lower facial height (r = 0.763(M), 0.787(F)). 3. All measurements for dento-alveolar relation showed no statistically significant sex difference. Maxillary length showed strong correlation with mandibular plane - lower incisor (r = 0.474(M), 0.426(F)) and mandibular plane - lower molar (r = 0.488(M), 0.499(F)).

Comparison of Thickness, Tension, and Activation of the Scm and Upper Trapezius Muscles According To The Pillow Height (베개 높이에 따른 SCM과 Upper trapezius의 근 두께, 근 긴장도, 근 활성화 측정비교)

  • Eun-mi Kim;Min-gi Park;Eun-joung Yu;Dongyeop Lee;Ji-Heon Hong;Jae-Ho Yu;Jin-Seop Kim;Yeon Gyo Nam;Seong-Gil Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.19 no.1
    • /
    • pp.53-60
    • /
    • 2024
  • PURPOSE: The study aimed to analyze the effect of pillow height on upper trapezius and sternocleidomastoid (SCM) muscle activity and overall human body comfort to determine the optimal pillow height. METHODS: The study included 32 healthy college students, of both genders, who provided prior consent. It examined three pillow heights (flat, 6cm, 12cm) and measured the upper trapezius and SCM muscles using ultrasonography, myotone, and electromyography(EMG). Muscle activation, thickness, and fatigue were assessed. RESULTS: The study found significant differences in muscle thickness and muscle tone based on the pillow heights (flat, 6cm, and 12cm) with a p < .05. The SCM and upper trapezius muscles were thinnest at a pillow height of 6cm. Muscle tone in the SCM was lower at both 6cm and 12cm pillow heights. Post-hoc measurements showed significant differences in both the SCM and upper trapezius muscles thickness at the 6cm pillow height (p < .05). Also, significant differences in muscle tone were observed only in the SCM, particularly between the 6cm and 12cm pillow heights. CONCLUSION: The ultrasonography and myotone measurements showed a significant difference in muscle thickness and muscle tension, both of which were above 6cm, while there was no difference in muscle activation. Based on the strong correlation between muscle tension and muscle thickness with pillow height, this study concluded that the human body feels comfortable with a 6cm pillow height. Therefore, it is recommended to use a pillow height of 6cm when lying in a supine position.

Customized Necktie Design According to Man's Body Characteristics (part I) -Focused on the Length of Necktie- (체형을 고려한 맞춤형 넥타이 개발에 관한 연구(제1보) -넥타이 길이를 중심으로-)

  • 박은경;홍지원
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.11
    • /
    • pp.1198-1207
    • /
    • 2003
  • The purpose of this study was to develop customized necktie design according to Korean adult male's body characteristics. For this purpose, experimentations of visual sensory evaluation on visual stimuli which show a man's wearing various neckties were carried out. The subjects were students(n=130) majoring in fashion and design related area and experts(n=6). The data were analyzed by ANOVA, duncan test, pearson's correlation coefficient, cross tabulation using spss pc/sup +/ program. Also statistic of Korea adult men's body measurements(1997) were analyzed and used to decide appropriate necktie length according to the customer's various height. The results were as follows: First, there were significant difference in visual sensibility on the stimuli showing 1) relative location of belt and necktie, 2) neckties with various length using golden ratio to the experimental model's height. Therefore, the need of producing neckties with different length according to customer's various height were verified. Second, neckties with three different length(140cm, 145cm, 151cm) were suggested for the groups of 160cm-height, 170cm-height, 180cm-height according to Korean adult male's body characteristics and aspect of production.

Pile tip grouting diffusion height prediction considering unloading effect based on cavity reverse expansion model

  • Jiaqi Zhang;Chunfeng Zhao;Cheng Zhao;Yue Wu;Xin Gong
    • Geomechanics and Engineering
    • /
    • v.37 no.2
    • /
    • pp.97-107
    • /
    • 2024
  • The accurate prediction of grouting upward diffusion height is crucial for estimating the bearing capacity of tip-grouted piles. Borehole construction during the installation of bored piles induces soil unloading, resulting in both radial stress loss in the surrounding soil and an impact on grouting fluid diffusion. In this study, a modified model is developed for predicting grout diffusion height. This model incorporates the classical rheological equation of power-law cement grout and the cavity reverse expansion model to account for different degrees of unloading. A series of single-pile tip grouting and static load tests are conducted with varying initial grouting pressures. The test results demonstrate a significant effect of vertical grout diffusion on improving pile lateral friction resistance and bearing capacity. Increasing the grouting pressure leads to an increase in the vertical height of the grout. A comparison between the predicted values using the proposed model and the actual measured results reveals a model error ranging from -12.3% to 8.0%. Parametric analysis shows that grout diffusion height increases with an increase in the degree of unloading, with a more pronounced effect observed at higher grouting pressures. Two case studies are presented to verify the applicability of the proposed model. Field measurements of grout diffusion height correspond to unloading ratios of 0.68 and 0.71, respectively, as predicted by the model. Neglecting the unloading effect would result in a conservative estimate.

The Validity of Head Posture Aligner in Posteroanterior Cephalometry (정모 두부 방사선 사진 촬영시 Head Posture Aligner의 유용성에 관한 연구)

  • Kim, Eun-Hee;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.543-552
    • /
    • 2000
  • The purposes of this study were to evaluate the reproducibility of posteroanterior(PA) cephalograms obtained by two methods, the Head Posture Aligner(HPA) method in natural head posture and the conventional method(operator-guided method), and to compare the vertical rotational differences of the head Posture between lateral and PA cephalograms according to the method. The sample was consisted of 30 adults. At first day, a PA cephalogram and a lateral cephalogram were obtained from each subject by two methods to investigate the difference of vertical rotational posture between lateral and PA cephalograms. Two weeks later, another PA cephalogram was obtained using each method to evaluate the reproducibility of head posture. Five height measurements and nine width measurements were used in the paired t-test to compare the reproducibility of the PA cephalometric measurements between two methods. The differences of vertical rotational posture between lateral and PA cephalograms were calculated from a computer program and compared according to the method used, and following results were obtained. 1. Height measurements obtained by operator-guided method showed significant differences according to the time interval and revealed low reproducibility. 2. Height measurements obtained by HPA method did not show significant differences according to the time interval and presented high reproducibility. 3. In the comparison of width measurement, two methods did not show distinct differences in reproducibility. 4. The difference of vertical rotational posture between lateral and PA cephalograms showed $0.8^{\circ}$ in the HPA method, more less than $2.5^{\circ}$ in the operator-guided method. The results of the present study suggest that the HPA may be helpful in the PA cephalometric radiography in terms of reproducibility.

  • PDF

Comparison of asymmetric degree between maxillofacial hard and soft tissue in facial asymmetric subjects using three-dimensional computed tomography (안면비대칭자의 3차원 전산단층사진 분석에서 경$\cdot$연조직간 비대칭 정도 차이)

  • Kim, Wang-Sik;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.163-173
    • /
    • 2005
  • The purpose of this study was to compare the asymmetric degree between maxillofacial hard and soft tissues in individuals with facial asymmetry. Computerized tomographies (CT) of 34 adults (17 male, 17 female) who had facial asymmetry were taken. The CT images were transmitted to personal computers and then reconstructed into three-dimensional (3D) images through the use of computer software. In order to evaluate the degree of facial asymmetry, 6 measurements were constructed as the hard tissue measurements while 6 counterpart measurements were taken as the soft tissue measurements. The means and standard deviations were obtained for each measurement using 3D measure, then t-test was used to investigate the differences between each hard tissue measurement and the corresponding soft tissue measurement All measurements used in the present study showed statistically significant differences between the hard and soft tissues. The degree of soft tissue asymmetry was smaller than that of corresponding hard tissue asymmetry in case of chin deviation, frontal ramal inclination difference, and frontal corpus inclination difference. On the other hand, the degree of soft tissue asymmetry was greater than that of underlying hard tissue asymmetry in the measurement of lip canting and lip cheilion height difference The present study suggests that asymmetric differences of hard and soft tissue is observed nu facial asymmetric subjects and thus soft tissue analysis is needed in addition to hard tissue analysis when making an evaluation of facial asymmetry.

Comparison of 3D Scanned Anthropometric Data between Korean and American Adults by using Ratios and Indices (지수치를 활용한 한국과 매국 성인 3차원 인체치수 비교)

  • Yi, Kyong-Hwa;Istook, Cynthia
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.6
    • /
    • pp.959-967
    • /
    • 2008
  • The body measurement ratios and indices used in this study are all 3D female measurement data of the two countries were obtained from Size Korea Project and SizeUSA Project. The purpose of the study is to compare and analyze body measurement data between two countries. The results of this research are helpful for the clothing manufacturer and company to trade with America. The samples were 1,988 Korean and 6,306 American females. Thirty-five body measurement ratios and indices were chosen as the principal measurements in making garments. The conclusion of this research was as follow; First, U.S. females have measurements that exceed Korean women, except for crotch length total and shoulder slope. Second, the correlation coefficients of height and weight are relatively higher than other measurements in the two countries' body measurements. Finally, American women's height ratios are significantly bigger than Korean women's in most height ratios. On the other hand, Korean are significantly bigger than American in weight ratios. The drop values of Korean females are also smaller than those of American. It was recognized that American women are much bigger, wider and more obese than Korean according to the results by utilizing the girth ratios. BMI, Rohrer and Vervaeck index.

Development of Wave Monitoring System using Precise Point Positioning (PPP 기반 항법 알고리즘을 이용한 파고 계측시스템 설계 및 구현)

  • Song, Se Phil;Cho, Deuk Jae;Park, Sul Gee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.5
    • /
    • pp.1055-1062
    • /
    • 2015
  • A GPS based wave height meter system is proposed in this paper. The proposed system uses a dual-frequency measurements, a precise GPS satellite information and a PPP-based navigation algorithm to estimate the position with high accuracy. This method does not need to receive corrections from the reference stations. Therefore, unlike RTK based wave meter, regardless of the distance to the reference stations, it is possible to estimate position with high accuracy. This system is very simple and accurate system, but accelerometer-based system requires the other sensors such as GPS. Because position error is accumulated in the accelerometer system and must be removed periodically for high accuracy. In order to get the measurements and test the proposed wave height meter system, a buoy equipped with the test platform is installed on the sea near by Jukbyeon habor in Uljin, Korea. Then, to evaluate the performance, compares built-in commercial wave height meter with proposed system.

CHANGES IN TONGUE POSITION, AIRWAY WIDTH, GONIAL ANGLE, LOWER FACIAL HEIGHT AFTER BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY IN MANDIBULAR PROGNATHIC PATIENTS (하악전돌증 환자의 하악지분할시상골절단술 후 혀의 위치, 기도의 폭경, 하악각 및 구강용적의 변화)

  • Lee, Kyu-Hong;Hwang, Yong-In;Kim, Yoon-Ji;Cheon, Se-Hwan;Kim, Hyung-Wook;Park, Jun-Woo;Rhee, Gun-Joo;Park, Yang-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.2
    • /
    • pp.109-113
    • /
    • 2007
  • Introduction. In patients with mandibular prognathism, Bilateral Sagittal Split Ramus Osteotomy(BSSRO) combined with orthodontic treatment reduces oral volume and influences tongue and other surrounding tissues. Purpose of this study was to analyze post-operative tongue position and airway dimension, as well as mandibular changes in vertical, horizontal, and angular dimensions. Materials and methods. Height of dorsum of tongue, width of airway, gonial angle and lower facial height of mandibular prognathic patients who visited Kangdong Sacred Heart Hospital from Jan. 2001 to Dec. 2006 were anaylzed via pre-operative and post-operative cephalograms. T-test was used to compare pre-operative and post-operative measurements. Also, correlations among pre-operative measurements of the patients were analyzed. Results and conclusion. A significant correlation was shown between ANS-Xi-PM area and location of dorsum of tongue in pre-operative patients. A significant superior movement of tongue and decrease of airway width was observed in post-operative patients. Also the upper gonial angle decreased significantly.