Performance Evaluation of Vertical Vibration of Precast Concrete Slabs (프리캐스트 콘크리트 바닥판의 수직진동 허용치 평가)

  • Heo, Seok-Jae;Lee, Sang-Hyun;Cho, Seung-Ho;Chung, Lan;Kim, Sung-Bae;Park, Sung-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.662-667
    • /
    • 2009
  • In this study, the serviceability of Waffle shaped(WAS) and Double-Tee(DT) precast concrete slabs was evaluated and compared based on the vertical acceleration magnitude induced by walking and heel drop loads. Tests were conducted for practical building structures (a shopping mall in Hanam) of which floor systems used WAS and DT slabs. Natural frequencies of the slabs were similar to those obtained by using analytical models. The measured acceleration level was evaluated by vertical floor acceleration criteria presented by ISO-2631, AIJ(1991, Japan), and a previous study regarding floor vibration limit. Test results showed that both WAS and DT slabs satisfied all the criteria and the maximum acceleration level of WAS slabs was lower than that of DT slabs.

  • PDF

Measurements on the Characteristics of Dynamic and Vertical Vibration Transfer according to floors of Building Structures using Accelerometer and Dynamic signal analyzer (가속도계와 동적신호분석기를 이용한 건축물 바닥슬래브 동특성 및 수직진동 전달특성 측정)

  • Chun Ho-Min
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.29-34
    • /
    • 2006
  • In general, the vertical vibration problems for .strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions on the rahmen building structures. In order to examine the characteristics of vertical vibration, the modal test and the impact (heel-drop and hammer) excitation experiments were conducted several times on three building structures. The results from the experiments are analyzed and compared. with the results. The results of this study suggest that the characteristics of vertical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs and excitation forces.

  • PDF

An Experimental Study on the Vertical Vibration Transfer in Horizontal Way according to Shear Wall Building Structures due to Exciting Vibration Forces (전단벽식 건축구조물 수직진동의 수평방향 전달특성에 관한 실험연구)

  • Chun, Ho-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.3 s.108
    • /
    • pp.270-282
    • /
    • 2006
  • In general, the vertical vibration problems for strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions to near-rooms on the shear wall building structures. In order to examine the characteristics of vertical vibration, the modal test and the impact (heel-drop and hammer) excitation experiments were conducted several times on two building structure. The results from the experiments are analyzed and compared with the results. The results of this study suggest that the characteristics of vertical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs, and are effected the shear wall on the Path of the vibration transfer.

Vibration Analysis of Building Floor Subjected to Walking Loads (보행하중을 받는 건축물 바닥판의 진동해석)

  • 김기철;이동근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.414-421
    • /
    • 2001
  • Recently, the damping effect of building structures are greatly reduced because the use of non-structures members as like curtain wall are decreased and large open space are in need for the service of buildings. Assembly and office buildings with a lower natural frequency have a higher possibility of experiencing excessive vibration induced by human activities as like jumping, running and walking. These excessive vibration make the occupants uncomfortable and the serviceability deterioration. The common method of application of walking loads for the vibration analysis of structures subjected to walking loads is to inflict a series unit walking load and a periodic function at a node. But this method could not consider the moving effect of walking. In this study, natural frequency and damping ratio of plate structure are evaluated by heel drop tests. And new application of equivalent walking loads are introduced for vibration analysis of real slab system subjected to walking loads. The response obtained from the numerical analysis are compared well to the results measured by experimental tests. It is possible to efficiently analyze the vibration of floor which is subjected to walking loads by applying equivalent walking loads.

  • PDF

A Study on the One-leg Drop landing Pattern and Muscular Activity depending on Chronic Ankle instability among Basketball Club members (농구동호인의 만성발목관절불안정성에 따른 한발착지패턴과 근활성도에 관한 연구)

  • Jeong, Kyoung-Yeol;Kim, Tae-Gyu
    • Journal of Digital Convergence
    • /
    • v.19 no.2
    • /
    • pp.481-488
    • /
    • 2021
  • This study aimed to identify and to compare the difference the changes of one-leg drop landing pattern depending on chronic ankle instability (CAI) among basketball club members. For 30 basketball club members who are currently participating in recreational basketball games in Busan Metropolitan City, 21 CAI groups and 9 CON groups were classified according to the CAI standards provided by the International Ankle Consortium. The one-leg drop landing pattern was measured with the alignment of the lower extremity and joint movement at the initial contact (IC), and the point of peak knee flexion. In addition, the one-leg drop landing pattern was tested with the muscular activity of tibialis anterior, peroneus longus, medial gastrocnemius and gluteus medius at the initial contact (IC), heel contact (HC), and the point of peak knee flexion. The results of this study showed that there was no significant difference in lower limb alignment and lower limb muscular activity among single leg drop landing. These results showed no significant differences in the one leg drop landing pattern and muscular activity depending on CAI. The further studies should classify the types of chronic ankle instability and consider the physical demands and movement characteristics depending on their playing position for providing useful information on prevention of CAI in basketball club members.

Evaluation of Floor Vibration Existing in Apartment Building (기존 아파트 바닥의 수직진동 성능 평가)

  • Han Sang Whan;Lee Min Jung
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.221-228
    • /
    • 2004
  • In recent years building floors become larger and more spacious due to the development of new design methods and high strength and light weight materials. However, such long span floor systems may provide smaller amount of damping and have a longer period so that they may be more vulnerable to the floor vertical vibration. In Korea when floors are to be checked against the floor vertical vibration, the provisions developed in foreign countries have been used. However these guidelines have been developed based on human perception, which may vary from country to country. Also, Korea have particular floor systems, such as flat plate floor system of apartment building. This study attempts to evaluate the vibration performance of the floors in typical apartment buildings. Two different floors with the area of $28 m^2$ and $32 m^2$ were investigated. The criteria provided by ATC-1(1999), AISC-11(1997), AIJ(1991) and the local criteria developed in the previous study(Han, 2003) was used to check the acceptability of the floor vertical vibration.

Experimental study on vibration serviceability of steel-concrete composite floor

  • Cao, Liang;Liu, Jiepeng;Chen, Y. Frank
    • Structural Engineering and Mechanics
    • /
    • v.74 no.5
    • /
    • pp.711-722
    • /
    • 2020
  • In this study, on-site testing was carried out to investigate the vibration serviceability of a composite steel-bar truss slab with steel girder system. Impulse excitations (heel-drop and jumping) and steady-state motion (walking and running) were performed to capture the primary vibration parameters (natural frequency and damping ratio) and distribution of peak acceleration. The composite floor possesses low frequency (<8.3Hz) and damping ratio (<2.47%). Based on experimental, theoretical, and numerical analyses on fundamental natural frequency, the boundary condition of SCSS (i.e., three edges simply supported and one edge clamped) is deemed more comparable substitutive for the investigated composite floor. Walking and running excitations by one person (single excitation) were considered to evaluate the vibration serviceability of the composite floor. The measured acceleration results show a satisfactory vibration perceptibility. For design convenience and safety, a crest factor βrp describing the ratio of peak acceleration to root-mean-square acceleration induced from the walking and running excitations is proposed. The comparisons of the modal parameters determined by walking and running tests reveal the interaction effect between the human excitation and the composite floor.

Estimation of Group Walking Loads by System Identification of Building Structures (건축구조물의 시스템 식별을 통한 무리보행하중 평가)

  • 김태호;민경원;이동근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2003
  • The objective of this study is to estimate the frequency characteristics of group walking loads based on the information of measured responses. At first, dynamic properties such as natural frequencies and modes are obtained from input/output relation for building structures by heel drop test. Second, a method to estimate group walking loads by the transfer functions from measured responses to group walking loads is proposed. The method turned out to estimate the group walking loads accurately. Higher modes could be important in estimating the amplitude of group walking loads with the information of single walking load.

Vibration performance characteristics of a long-span and light-weight concrete floor under human-induced loads

  • Cao, Liang;Liu, Jiepeng;Zhou, Xuhong;Chen, Y. Frank
    • Structural Engineering and Mechanics
    • /
    • v.65 no.3
    • /
    • pp.349-357
    • /
    • 2018
  • An extensive research was undertaken to study the vibration serviceability of a long-span and light-weight floor subjected to human loading experimentally and numerically. Specifically, heel-drop test was first conducted to capture the floor's natural frequencies and damping ratios, followed by jumping and running tests to obtain the acceleration responses. In addition, numerical simulations considering walking excitation were performed to further evaluate the vibration performance of a multi-panel floor under different loading cases and walking rates. The floor is found to have a high frequency (11.67 Hz) and a low damping ratio (2.32%). The comparison of the test results with the published data from the 1997 AISC Design Guide 11 indicates that the floor exhibits satisfactory vibration perceptibility overall. The study results show that the peak acceleration is affected by the walking path, walking rate, and adjacent structure. A simpler loading case may be considered in design in place of a more complex one.

Experimental study on vibration serviceability of cold-formed thin-walled steel floor

  • Bin Chen;Liang Cao;Faming Lu;Y. Frank Chen
    • Steel and Composite Structures
    • /
    • v.46 no.4
    • /
    • pp.577-589
    • /
    • 2023
  • In this study, on-site testing was carried out to investigate the vibration performance of a cold-formed thin-walled steel floor system. Ambient vibration, walking excitation (single and double persons), and impulsive excitation (heel-drop and jumping) were considered to capture the primary vibration parameters (natural frequencies, damping ratios, and mode shapes) and vertical acceleration response. Meanwhile, to discuss the influence of cement fiberboard on structural vibration, the primary vibration parameters were compared between the systems with and without the installation of cement fiberboard. Based on the experimental analysis, the cold-formed thin-walled steel floor possesses high frequency (> 10 Hz) and damping (> 2%); the installed cement fiberboard mainly increases the mass of floor system without effectively increasing the floor stiffness and may reduce the effects of primary vibration parameters on acceleration response; and the human-structure interaction should be considered when analyzing the vibration serviceability. The comparison of the experimental results with those in the AISC Design Guide indicates that the cold-formed thin-walled steel floor exhibits acceptable vibration serviceability. A crest factor 𝛽rp (ratio of peak to root-mean-square accelerations) is proposed to determine the root-mean-square acceleration for convenience.