• Title/Summary/Keyword: heating system

검색결과 3,601건 처리시간 0.036초

서울 북촌한옥의 변화양상에 관한 연구 - 북촌 가꾸기 사업에 따른 2002~2007 한옥 대수선 사례를 대상으로 - (A study on the Changes in form and spatial uses of Urban Hanok in Bukchon, Seoul)

  • 송인호;김영수;조은주
    • 건축역사연구
    • /
    • 제18권2호
    • /
    • pp.47-63
    • /
    • 2009
  • This study focused on changes in form and spatial uses of Urban Hanok in Bukchon, Seoul. There are 10 representative cases which have been renovated through the policy of 'Preservation & Regeneration of Bukchon' by Seoul metropolitan government and other experts. Changes in form and spatial uses of Urban Hanok in Buckon are as follows. First, Changes of scale. Trough removing extension parts, facade of renovated Hanoks are 'transformed' into recovering their identity. Using basements or lofts, intensive application of spaces is transformation which promotes the vitality of Hanoks. Second, changes of space organization. As Hanok changes its function from residence to commercial or cultural use, il a1so changes space character or reorganizes space organization. It is important that deciding function of Hanok has to adjust its scale and organization. Third, changes of construction performance. Through introducing new material and constructing method, performance of wall has been changed respecting its wooden structure and interior-exterior figure. However, technical studies must back it up not to destroy its value of eco-friendly architecture. Fourth, changes of facility systems, like floor heating system. They changes floor level of Hanok equally, and then sections of Hanok have became simple. Furthermore, inserting new facility space, such as boiler room, stand-up kitchen, bathroom and toilet, organization of space also changed. It is necessary that wise alternative proposal through the method of transformation or mutation must be presented. These four changes can be classification into method of 'transformation' and 'mutation'. Changes of scale are method of transformation and changes of space organization are method of mutation. Also, while changes of construction performance are mutation, changes of facility systems are transformation. Recently, as price of lots have been increased, a lot of Hanoks have been commercialized. Thc commercial energy threat 'the identity of Bukchon as residential area'. From now on, to operate 'identity' and 'vitality' complementary, it is necessary to make up for the preservation policy of Hanok and consolidate renovating standards of Hanok which correspond to character of particular region and building usage.

  • PDF

특성 추출과 신경회로망을 이용한 열 풍로 열효율에 대한 모델링 (Modeling of heat efficiency of hot stove based on neural network using feature extraction)

  • 민광기;최태화;한종훈;장근수
    • 한국가스학회지
    • /
    • 제2권4호
    • /
    • pp.60-66
    • /
    • 1998
  • 열 풍로 공정은 고로 공정에 필요한 고온의 일정량의 공기를 연속적으로 생산하는 공정이다. 제철소 내에서 발생되는 부생가스를 연료로 사용하는 열 풍로 공정은 제선 공정 전체 에너지의 약 $20\%$를 소비하여 대표적인 에너지 소비 공정으로 인식되어 왔다. 그러므로, 열 풍로 열 효율 향상을 통한 에너지 절감 노력이 해석적인 방법과 실험적인 방법을 통해 지속적으로 이루어져 왔다. 조업 중 발생되는 열 전달 현상의 복잡성 그리고 조업 조건 변동에 따른 모델 내 Parameters들의 변화로 인하여 해석적인 방법을 통한 정확한 모델 구축에 많은 어려움을 겪어 왔다. 본 연구에서는 컴퓨터의 발전과 더불어 발전되어온 실험적 모델 중 하나인 신경회로망을 이용, 조업 변수들과 열 효율과의 관계를 나타내는 모델을 구축하고자 한다. 또한 기존 신경 회로망을 이용할 경우, 모델의 성능을 저하시키는 Over-parameterization의 문제점을 극복하기 위하여, 고차원의 조업 데이터를 Walsh-Hadamard 변환을 이용하여 저 차원으로 투영하여 조업 데이터의 특성을 추출, 이를 이용한 열 풍로 열 효율 예측을 위한 신경회로망 모델을 구축하였다. 본 연구를 통하여, 조업 변수들과 열 효율간의 관계를 나타내는 모델을 구축, 열 효율 예측결과를 나타냈으며, 모델의 예측 성능을 평가하기 위하여 다변량 통계적 방법인 Partial Least Square (PLS) 방법과 비교하였다.

  • PDF

조미김의 제조공정별 위해요소분석, 중요관리점 결정 및 한계기준 개발 (Hazard Analysis, Determination of Critical Control Points, and Establishment of Critical Limits for Seasoned Laver)

  • 강민정;이학태;김정연
    • 한국조리학회지
    • /
    • 제21권2호
    • /
    • pp.1-10
    • /
    • 2015
  • 본 연구에서는 조미김 식품제조 가공 업소에서 제조한 조미김을 대상으로 주요 원료 및 제조공정별 생물학적 위해요소분석을 실시하여 생물학적 중요관리점(CCP)을 파악하고, 이를 관리하고 모니터링하기 위한 한계기준을 설정하여 HACCP Plan을 제시하고자 한다. 본 연구 결과, 일반세균수는 2차 가열공정 이전에서는 $10^3{\sim}10^4CFU/g$의 높은 수준으로 검출되었으나, 2차 가열 이후에서는 $1.0{\times}10CFU/g$ 미만으로 검출되었다. 조미김의 제조공정별 병원성미생물 분석결과, 모든 제조공정에서 검출되지 않았다. 이와 같은 결과로 조미김의 제조 유통시 CCP는 2차 가열 과정으로 결정되었다. 가열온도를 $170{\pm}5^{\circ}C$, $200{\pm}0.5^{\circ}C$, $230{\pm}5^{\circ}C$로 하고, 각각의 온도에서 가열시간을 $3.0{\pm}5$초, $4.0{\pm}0.5$초, $5.5{\pm}0.5$초로 실시하면서 일반세균과 병원성미생물을 시험한 결과, 2차 가열 전 병원성 미생물은 음성이었다. 일반세균은 $230{\pm}5^{\circ}C$일 때 현저히 감소되었고, 특히 가열시간을 $5.5{\pm}0.5$일 때 $1.0{\times}10CFU/g$ 이하로 나타났다. 미생물학적 위해요소를 HACCP 시스템에 적용하여 생산한 조미김의 경우 상품가치와 품질, 안전성을 확보하기에 가장 적절한 가열온도와 가열시간은 $230{\pm}5^{\circ}C$, 가열시간은 $5.5{\pm}0.5$초로 한계기준을 설정하였다. 본 연구를 통하여 제조공정별 위해요소분석을 활용하여 조미김의 중요관리점 및 한계기준을 설정하였고, 이를 통하여 HACCP 계획을 수립하고, 사후관리 등에 활용할 수 있다.

연탄(煉炭)가스중독(中毒)의 발생실태(發生實態)에 관(關)한 연구(硏究) (A Study on the Incidence of Carbon Monoxide Poisoning)

  • 조수헌;신영수;이덕형;김용익;윤덕로
    • Journal of Preventive Medicine and Public Health
    • /
    • 제18권1호
    • /
    • pp.1-11
    • /
    • 1985
  • A decade ago a survey on the population-base incidence rate of anthracite coal gas (mainly carbon monoxide) poisonig in Seoul area was investigated, resulting in the incidence rate of 306/10,000 risk population and 1 death/10,000. Another survey on the carbon monoxide poisoning was investigated during 1 year period from Apr. 1983 to Mar. 1984. Total subjects of risk population were 67,740 households covering 353,287 persons. The major findings of this survey are as follows: 1. Household-base incidence rate was 8.4% spell-base 10.4%. 2. The incidence rate was the highest in houses having each of slate roof, cement wall, vinyl floor of bedroom and direct 'ondol' heating system. 3. Average 2.1 person was attacked from one incidence of the poisoning; severity-wise person-base incidence rates per 10,000 were 352 in mild poisoning, 54 in severe poisoning and 1.4 in death-overall incidence rate 407. Several facts were identified which supported that this figure was moderately underestimated. As the incidence of the poisoning is affected by socioeconomic and environmental factors, it is natural that one expects the incidence will decrease in proportion to genernal improvement of the above factors. Thus the results of these two surveys seemed preposterous. But further study suggested that the incidence rate (306/10,000) decade before had been significantly underestimated and corrected-rate should have been 478/10,000 level. 4. Age and sex distribution by the degree of the poisoning was uniform with little statistical difference; overall incidence rates by sex were 339/10,000 in male and 475/10,000 in female with significant statistical difference(p<.01). 5. 5.3% of the patients were treated at hospital or local clinic; 3.0% of the patients were hospitalized. Admission rate in comatose patient(severe poisoning) was 14.2%. In conclusion, carbon monoxide poisoning remains a major health problem by now.

  • PDF

HVAC 상실사고시 울진원전 3/4 호기의 보조급수펌프 격실 온동상승 평가 (Heat-up Calculation for the Auxiliary Feed Water Pump Room at Ulchin Units 3 and 4 for Loss of HVAC Accidents)

  • 윤철;박진희;황미정;한상훈
    • 대한기계학회논문집B
    • /
    • 제36권5호
    • /
    • pp.553-562
    • /
    • 2012
  • 난방, 환기 및 공기조절(HVAC) 기능이 상실된 사고의 경우, 보조급수를 위한 모터-구동 펌프격실의 온도상승을 전산유체역학 분석을 통해 평가하였다. 닫힌 펌프격실의 과도 계산결과, 8 시간 동안 공간-평균된 공기온도는 $60^{\circ}C$ 정도의 상승이 예상된다. 외기 온도 및 외부 온도는 이전 계산결과로부터 초기 $35^{\circ}C$에서 시작하여 서서히 증가한다고 가정하였다. 격실 문이 사고발생 후 약 2, 4, 그리고 6시간 경과 시점에서 열릴 경우, 체적-평균 격실 내가 온도는 약 $4^{\circ}C$의 즉각적인 하강이 나타나며 이후 서서히 온도가 상승하는 장기 거동을 보인다. 전산유체역학을 적용한 현재의 상세 해석결과는 이전의 집중(lumped) 모델을 사용한 보수적인 계산결과에 비해 낮은 격실온도 상승률을 예측한다.

Three-dimensional Numerical Prediction on the Evolution of Nocturnal Thermal High (Tropical Night) in a Basin

  • Choi, Hyo;Kim, Jeong-Woo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제25권1호
    • /
    • pp.57-81
    • /
    • 1997
  • Numerical prediction of nocturnal thermal high in summer of the 1995 near Taegu city located in a basin has been carried out by a non-hydrostatic numerical model over complex terrain through one-way double nesting technique in the Z following coordinate system. Under the prevailing westerly winds, vertical turbulent fluxes of momentum and heat over mountains for daytime hours are quite strong with a large magnitude of more than $120W/\textrm{m}^2$, but a small one of $5W/\textrm{m}^2$ at the surface of the basin. Convective boundary layer (CBL) is developed with a thickness of about 600m over the ground in the lee side of Mt. Hyungje, and extends to the edge of inland at the interface of land sea in the east. Sensible heat flux near the surface of the top of the mountain is $50W/\textrm{m}^2$, but its flux in the basin is almost zero. Convergence of sensible heat flux occurs from the ground surface toward the atmosphere in the lower layer, causing the layer over the mountain to be warmed up, but no convergance of the flux over the basin results from the significant mixing of air within the CBL. As horizontal transport of sensible heat flux from the top of the mountain toward over the basin results in the continuous accumulation of heat with time, enhancing air temperature at the surface of the basin, especially Taegu city to be higher than $39.3^{\circ}C$. Since latent heat fluxes are $270W/\textrm{m}^2$ near the top of the mountain and $300W/\textrm{m}^2$ along the slope of the mountain and the basin, evaporation of water vapor from the surface of the basin is much higher than one from the mountain and then, horizontal transport of latent heat flux is from the basin toward the mountain, showing relative humidity of 65 to 75% over the mountain to be much greater than 50% to 55% in the basin. At night, sensible heat fluxes have negative values of $-120W/\textrm{m}^2$ along the slope near the top of the mountain and $-50W/\textrm{m}^2$ at the surface of the basin, which indicate gain of heat from the lower atmosphere. Nighttime radiative cooling produces a shallow nocturnal surface inversion layer with a thickness of about 100m, which is much lower than common surface inversion layer, and lifts extremely heated air masses for daytime hours, namely, a warm pool of $34^{\circ}C$ to be isolated over the ground surface in the basin. As heat transfer from the warm pool in the lower atmosphere toward the ground of the basin occurs, the air near the surface of the basin does not much cool down, resulting in the persistence of high temperature at night, called nocturnal thermal high or tropical night. High relative humidity of 75% is found at the surface of the basin under the moderate wind, while slightly low relative humidity of 60% is along the eastern slope of the high mountain, due to adiabatic heating by the srong downslope wind. Air temperature near the surface of the basin with high moisture in the evening does not get lower than that during the day and the high temperature produces nocturnal warming situation.

  • PDF

강섬유 콘크리트 혼입율에 따른 내부앵커형 콘크리트 충전기둥 내화성능에 관한 해석적 연구 (Analysis Study on Fire Performance with Internal Anchored Concrete Filled Steel Tube Columns According to Percent of Steel-Fibers)

  • 김선희;염경수;김용환;최성모
    • 한국강구조학회 논문집
    • /
    • 제28권1호
    • /
    • pp.23-34
    • /
    • 2016
  • 콘크리트 충전강관 기둥은 강관의 구속효과에 의해 콘크리트의 압축내력 상승과, 콘크리트에 의한 강관의 국부좌굴 보강효과에 의해 부재내력이 상승하고 뛰어난 변형성능을 발휘한다. 하지만, 기둥단면이 커질 경우 합성효과를 발휘하기 위하여 스터드 볼트나 후 시공 앵커 볼트를 사용해야 하는 시공상의 문제점이 발생된다. 이를 극복함과 동시에 합성효과를 증대시키기 위한 방안으로 내부에 리브가 설치된 용접조립 기둥이 소개되었다. 내부 리브는 콘크리트와 맞물려 있어 리브의 변형은 콘크리트의 균열을 촉진시키는 역할을 동반하게 된다. 이러한 잠재적인 문제에 대한 해결책은 강관 리브의 변형에 저항할 수 있도록 콘크리트 인성을 증가시킬 수 있는 방안이 필요하다. 언급된 두 가지의 문제점이 효과적으로 해결될 경우 용접조립 각형강관 기둥은 내화성능 확보가 가능하다고 판단된다. 본 연구에서는 해결방안으로 내부 콘크리트를 강섬유와 혼입하여 기둥 자체의 연성과 인성을 증대시키는 것에 중점을 맞추고 있다. 내화성능 평가를 위한 시험체는 총 8개 로 하중비에 따른 재하가열 실험을 실시하고 화재 전후 거동과 열 변형 능력을 주요변수별로 분석하였다. 실험결과와 선행연구 비교를 통해 열 전달과 열응력 해석 모델의 신뢰성을 확보하였으며, 강섬유 혼입율에 따른 변수해석을 수행하였다.

Effect of Bambusae caulis in Liquamen on Streptozocin-Induced Diabetic C57BL/6 Mice

  • Deung Young-Kun;Park Seung-Kyu;Jin Dan;Yang Eun-Ju;Lim Soo-Jung;Kwon Ki-Rok;Kim Dong-Heui;Lee Kyu-Jae
    • 대한의생명과학회지
    • /
    • 제11권3호
    • /
    • pp.343-347
    • /
    • 2005
  • Bambusae caulis in Liquamen is one of the important herbal medicine produced by heating bamboo indirectly and is used for treatment of stroke, hypertension, and diabetes etc. Recently the mechanism of clinical effects on Bambusae caulis in Liquamen has been studied. This experiment was conducted to confirm the clinical effects of Bambusae caulis in Liquamen on type 1 diabetes and its related mechanism. We divided C57BL/6 mice into 3 groups and induced them to be type 1 diabetes by injection of streptozocin into peritoneum. The dosage of each group was 150 mg/kg once only, 140 mg/kg once only and 40 mg/kg for 5 days respectively. The two groups injected streptozocin for once took orally Bambusae caulis in Liquamen after the induction of diabetes, and the other one group was given Bambusae caulis in Liquamen during the diabetes inducing period. As the result, the two diabetes-induced groups showed blood glucose decreasing effect by Bambusae caulis in Liquamen on an average, but they didn't show the signiftcant differences statistically. But Bambusae caulis in Liquamen showed the anti-diabetic effect suppressing blood sugar rising trend during the diabetes inducing peried (P<0.05). The anti-oxidative effect of Bambusae caulis in Liquamen was measured with the hypoxanthine/xanthine oxidase (HX/XOD) system. The quantity of ROS was measured using DCFDA reagent indirectly. As the result, $10\%$ solution of Bambusae caulis in Liquamen showed anti-oxidative effect by scavenging $93.4\%$ superoxide as compared with control group. It is suspected that the anti-oxidative effect of Bambusae caulis in Liquamen suppressed the increase of blood glucose in the diabetes-inducing group. These results could be useful data to understand the effect of Bambusae caulis in Liquamen on type 1 diabetes and type 1 diabetes developing because ROS were closely connected with the induction and complications of diabetes.

  • PDF

병렬 U형 현장타설 에너지파일의 열교환 효율 및 적용성 평가 (Evaluation of Heat Exchange Efficiency and Applicability for Parallel U-type Cast-in-place Energy Pile)

  • 박상우;김병연;성치훈;최항석
    • 대한토목학회논문집
    • /
    • 제35권2호
    • /
    • pp.361-375
    • /
    • 2015
  • 에너지파일은 기존의 수직밀폐형 지중열교환기를 경제적으로 대체할 수 있는 새로운 형태의 지중열교환기이다. 즉, 에너지파일은 건물의 기초 구조물과 지중열교환기의 역할을 동시에 수행하는 에너지 구조체로서, 말뚝 기초 내부에 열교환 파이프를 삽입하고 파이프를 통해 유체를 순환시켜 지반과의 열교환을 유도한다. 본 연구에서는 병렬 U형(5쌍, 8쌍, 10쌍)의 열교환 파이프를 대구경 현장타설 에너지파일에 삽입하여, 3본의 에너지파일을 실규모로 시공하였다. 또한 현장 열응답 시험(In-situ thermal response tests, TRTs)을 수행하고 시공된 현장타설 에너지파일과의 열교환 효율을 비교하기 위하여 30m 깊이의 수직밀폐형 지중열교환기를 별도로 시공하였다. 병렬 U형 현장타설 에너지파일에 대해서는 냉난방 부하를 인공적으로 주입하는 열교환 성능 평가시험을 수행하여 열교환 성능(heat exchange rate)을 평가하였다. 마지막으로 현장타설 에너지파일의 적용성 평가를 위해 산정된 상대 열교환 효율(relative heat exchange efficiency) 및 열교환 성능을 선행 연구 결과와 비교하였으며, 본 연구에서 시공된 현장타설 에너지파일은 안정적이고 효율적인 열성능을 보이는 것으로 나타났다.

인코넬 718강의 UNSM처리재의 고온하의 피로특성에 관한 연구 (Inconel 718 and UNSM Treated Alloy Study on the Rotary Bending High Temperature Fatigue Characteristics under a Light Concentrating System)

  • 서창민;남승훈;우영한;허광호;홍상휘;김준형;편영식
    • 대한기계학회논문집A
    • /
    • 제40권11호
    • /
    • pp.935-941
    • /
    • 2016
  • 고온기기의 부재로 널리 사용되는 인코넬 718을 사용하여 UNSM 표면처리법에 의한 처리효과를 기기의 사용조건을 고려한 실온, $300^{\circ}C$, $500^{\circ}C$$600^{\circ}C$ 의 세 가지 온도레벨하의 대기 중에서 고온피로 시험을 실시하여 각 시험편의 온도에 따른 피로특성을 연구하였다. 이때 고온회전굽힘피로시험(R=-1)은 할로겐(Halogen) 램프를 사용한 집광식인 가열방식을 선택한 새로운 피로시험기를 사용하였다. 인코넬 718의 고온피로강도는 상온에 비하여 감소하였다. 그러나 설계응력레벨에서는 상온의 내구한도와 유사한 경향을 나타내었다. UNSM 처리된 고온피로특성은 미처리재에 비하여 설계응력레벨에서 크게 향상되었다. 미처리재의 $300^{\circ}C$$500^{\circ}C$ 사이의 온도 영향은 거의 없었지만, $600^{\circ}C$에서는 높은 응력레벨에서 피로수명이 짧아졌지만, 낮은 설계응력레벨에서는 상온의 S-N선도보다 피로수명이 증가되는 경향을 나타내었다.