• Title/Summary/Keyword: heating period

Search Result 539, Processing Time 0.031 seconds

Analysis of Building Energy by the Typical Meteorological Data (표준기상데이터(부산지역) 비교 및 분석)

  • Yoo, Ho-Chun;Lee, Kwan-Ho;Kang, Hyun-Gu
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.13-18
    • /
    • 2009
  • Building is a major energy consumer, and now many efforts are made to save energy in the design and using equipments. The most noticeable achievement in those efforts is a building energy performance assessment program. But most programs are not satisfying enough to provide exact meteorological data, and data source and calculation, and data collection period are not clearly defined. That is common in most of domestic programs. This study collects typical meteorological data in 16 items and analyzes them with Visual DOE 4.0 to compare with existing data. The comparison found that revised data shows a 11% increase on average during cooling period from June to September, and a 13% decrease on average during heating period from December to February, in terms of building heating and cooling load in a monthly basis.

  • PDF

A Study on the Standard Weather Data for Seoul (서울지방의 표준기상데이터에 관한 연구)

  • Kim, Doo-Chun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.2
    • /
    • pp.125-137
    • /
    • 1985
  • Standard weather data for Seoul has been developed for use in computer calculations for energy requirements, and the 8760 sequential hourly values for seven weather elements have been placed in magnetic tape and cards. Applying the method determining average month, developed by Japanese Society of Heating, Air-Conditioning and Sanitary Engineers, the standard year data have been selected from the monthly average values for three weather elements during the 10year period of 1971 through 1980. The followings are obtained. 1. The Test Reference Year, consisting of 12 months chosen from different calendar years, has been determined, and TRY tape which contains seven weather elements has been prepared. 2. The Typical Weather Year, which means a year close to the average value, is the year of 1978 during the above 10 year period. 3. During the period, Winter Season needs the maximum heating load is from Dec. 1976 to Mar. 1977 and Summer Season needs the maximum cool ins load is from Jun. to Sep, 1978.

  • PDF

Comparative Analysis of Accumulated Temperature for Seasonal Heating Load Calculation in Greenhouses (온실의 기간난방부하 산정을 위한 난방적산온도 비교분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.192-198
    • /
    • 2014
  • To establish the design criteria for seasonal heating load calculation in greenhouses, standard weather data are required. However, they are being provided only at seven regions in Korea. So, instead of using standard weather data, in order to find the method to build design weather data for seasonal heating load calculation, heating degree-hour and heating degree-day were analyzed and compared by methods of fundamental equation, Mihara's equation and modified Mihara's equation using normal and thirty years from 1981 to 2010 hourly weather data provided by KMA and standard weather data provided by KSES. Average heating degree-hours calculated by fundamental equation using thirty years hourly weather data showed a good agreement with them using standard weather data. The 24 times of heating degree-day showed relatively big differences with heating degree-hour at the low setting temperature. Therefore, the heating degree-hour was considered more appropriate method to estimate the seasonal heating load. And to conclude, in regions which are not available standard weather data, we suggest that design weather data should be analyzed using thirty years hourly weather data. Average of heating degree-hours derived from every year hourly weather data during the whole period can be established as environmental design standards, and also minimum and maximum of them can be used as reference data for energy estimation.

Study on Heating Performance of Hybrid Heat Pump System Using Geothermal Source and Solar Heat for Protected Horticulture (시설원예용 지열 및 태양열 이용 하이브리드 히트펌프 시스템의 난방성능에 관한 연구)

  • Jeon, Jong Gil;Lee, Dong Geon;Paek, Yee;Kim, Hyung Gweon
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.5
    • /
    • pp.49-56
    • /
    • 2015
  • In this study a hybrid heating system based on geothermal source and solar heat was developed in order to save energy for greenhouse heating and its field performance was evaluated. Developed system are composed of following parts: water tank, heat exchanger, heat pump, fan coil unit and heat storage unit. The working performance test was carried out in a greenhouse cultivating oriental orchids being managed by $23^{\circ}C$. Field performance test results showed that average heating coefficient of performance ($COP_h$) was 3.4 for the period from mid-January to mid-March 2013. Heating coefficient of performance ($COP_h$) of developed hybrid heat pump system was more sensitive to water tank temperature than outside air temperature. This study showed that developed hybrid heat pump system has a potential to save the heating costs up to 91% compared to conventional agricultural oil heaters.

Antimicrobial Activity of Garlic Heated under Different Conditions, Time of Heating, and pH

  • Kim, Eun-Hee;Kang, Seung-Sik;Kang, Dong-Hee;Kyung, Kyu-Hang
    • Food Science and Biotechnology
    • /
    • v.18 no.3
    • /
    • pp.771-775
    • /
    • 2009
  • Antimicrobial activity of garlic (pH 6.0) heated at $120^{\circ}C$ reached its maximum at 45 min of heating and maintained the level for the rest of heating time (300 min) when tested against Candida utilis ATCC42416. The principal antimicrobial compound was allyl alcohol (AA), a highly volatile compound without sulfur in its molecule. The concentration of AA in heated garlic gradually increased to over 2,000 ppm for the first 90 min and stayed at the level without appreciable changes in spite of further heating. Other antimicrobial compounds secondary to AA were lowly volatile sulfur compounds including diallyl polysulfides (diallyl trisulfide, diallyl tetrasulfide, and diallyl pentasulfide) and heterocyclic sulfur compounds (4-methyl-1,2,3-trithiolane, 5-methyl-1,2,3,4-tetrathiane, and 6-methyl-1,2,3,4,5-pentathiepane). When the pH of the garlic extract was lowered before heating, considerably more secondary antimicrobial sulfur compounds were formed and the antimicrobial activity was stronger than the pH unadjusted garlic. Lowly volatile sulfur compounds contributed a significant part of antimicrobial activity of heated garlic only during the early period (45-120 min) of heating regardless of pH treatment.

The Impact of Interaction between Cloud and Longwave Radiation on the Asian Monsoon Circulation (구름-장파복사 상호작용이 아시아 몬순에 미치는 영향)

  • Ryu, Geun-Hyeok;Sohn, Byung-Ju
    • Journal of the Korean earth science society
    • /
    • v.30 no.1
    • /
    • pp.58-68
    • /
    • 2009
  • Three-dimensional distributions of longwave radiation flux for the April-September 1998 period are generated from radiative transfer calculations using the GEWEX Asian Monsoon Experiment (GAME) reanalysis temperature and humidity profiles and International Satellite Cloud Climatology Project (ISCCP) cloudiness as inputs to understand the effect of cloud radiative forcing in the monsoon season. By subtracting the heating of the clear atmosphere from the cloudy radiative heating, cloud-induced atmospheric radiative heating has been obtained. Emphasis is placed on the impact of horizontal gradients of the cloud-generated radiative heating on the Asian monsoon. Cloud-induced heating exhibits its maximum heating areas within the Indian Ocean and minimum heating over the Tibetan Plateau, which establishes the north-south oriented differential heating gradient. Considering that the differential heating is a ultimate source generating the atmospheric circulation, the cloud-induced heating gradient established between the Indian Ocean and the Plateau can enhance the strength of the north-south Hadley-type monsoon circulation. Cooling at cloud top and warming at cloud bottom, which are the vertical distributions of cloud-induced heating, can exert on the monsoon circulation by altering the atmospheric stability.

Research on the Thermal Comfort Heating Mode Considering Psychological and Physiological Response of Automobile Drivers (운전자의 심리·생리 반응을 고려한 승용차 쾌적 난방 모드에 관한 연구)

  • Kim, Min Soo;Kum, Jong Soo;Park, Jong Il;Kim, Dong Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.149-157
    • /
    • 2018
  • In this research, the psychological and physiological reactions of the driver were measured during winter to evaluate thermal comfort. The experiment was conducted using 3 different cases which are hot air heating, warm-wire seat heating and hot air & warm-wire seat heater operating simultaneously. With regard to psychological reaction, the warm-wire heating mode was the most preferred. The reason is that it is dry in other cases. With regard to EEG response, thermal comfort increased by 37% in warm air mode heating. In addition, when the warm-wire heating mode and the hot air & warm-wire heating mode were simultaneously operated, the thermal comfort continuously increased by between 17% and 20% for 20 minutes after boarding. Under the change of the autonomic nervous system, the thermal stress level increased by 23% after 15 minutes on board in the hot air heating mode and decreased continuously by 13% during the warm-wire seat heating mode. We recommended the hot air heating mode is only used for a short time to raise the inside temperature during the early boarding period and that warm-wire seat heating mode be actively utilized.

Development of On-site Heat Loss Audit and Energy Consulting System for Greenhouse

  • Kwon, Jin Kyung;Kang, Geum Choon;Lee, Seong Hyun;Sung, Je Hoon;Yun, Nam Kyu;Moon, Jong Pil;Lee, Su Jang
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.287-294
    • /
    • 2013
  • Purpose: Greenhouses for a protected horticulture covered with a plastic or glass are easy to have weakness in a heat loss by deterioration, damage, poor construction, and so on. To grasp the vulnerable points of heat loss of the greenhouses is important for heating energy saving. In this study, an on-site heat loss audit and energy consulting system were developed for an efficient energy usage of a greenhouse. Method: Developed system was mounted with infrared thermal and visual cameras to grasp the heat loss from the greenhouse quickly and exactly, and a trial calculation program of heating load of greenhouse to provide farmers with the information of heating energy usage. Results: Developed system could print out the reports about the locations and causes of the heat losses and improvement methods made up by an operator. The mounted trial calculation program could print out the information of the period heating load and fuel cost according to the conditions of greenhouse and cultivation. The program also mounted the databases of the information on the 13 horticultural energy saving technologies developed by the Korea Rural Development Administration and simple economic analysis sub-program to predict the payback period of the technologies. Conclusion: The developed system was expected to be used as the basic equipment for an instructors of district Agricultural Technology and Extension Centers to conduct the energy consulting service for the farmers within the jurisdiction.

Dynamic Simulation of Ground Source Heat Pump with a Vertical U-tube Ground Heat Exchanger (수직형 U자 관 지중 열교환기를 갖는 지열원 열펌프의 동적 시뮬레이션)

  • Lee, Myung-Taek;Kim, Young-Il;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.5
    • /
    • pp.372-378
    • /
    • 2007
  • GHX (Geothermal Heat Exchanger) design which determines the performance and initial cost is the most important factor in ground source heat pump system. Performance of GHX is strongly dependent on the thermal resistance of soil, grout and pipe. In general, GHX design is based on the static simulation program. In this study, dynamic simulation has been peformed to analyze the variation of system performance for various GHX parameters. Line-source theory has been applied to calculate the variation of ground temperature. The averaged weather data measured during a 10-year period $(1991\sim2000)$ in Seoul is used to calculate cooling and heating loads of a building with a floor area of $100m^2$. The simulation results indicate that thermal properties of borehole play significant effect on the overall performance. Change of grout thermal conductivity from 0.4 to $3.0W/(m^{\circ}C)$ increases COP of heating by 9.4% and cooling by 17%. Change of soil thermal conductivity from 1.5 to $4.0W/(m^{\circ}C)$ increases COP of heating by 13.3% and cooling by 4.4%. Change of GHX(length from 100 to 200 m increases COP of heating by 10.6% and cooling by 10.2%. To study long term performance, dynamic simulation has been conducted for a 20-year period and the result showed that soil temperature decreases by $1^{\circ}C$, heating COP decreases by 2.7% and cooling COP decreases by 1.4%.

Growth effects of novel heating system using heater-installed rearing tray on silkworm, Bombyx mori

  • Jeong, Chan Young;Kim, Kee Young;Kim, Nam-Suk;Kang, Sang Kuk;Park, Jong Woo;Cha, Ik Seob;Kim, Seong-Wan
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.45 no.1
    • /
    • pp.22-28
    • /
    • 2022
  • Silkworms are very sensitive to changes in temperature and humidity, and unless it is a suitable temperature and humidity to grow, the productivity and quality of silkworms are greatly reduced. Therefore, it is very important to manage temperature and humidity for silkworm feeding facilities. In particular, it is essential to install heating facilities in Asian countries with distinct seasonal changes. During the feeding period, many farms manage the temperature and humidity of feeding facilities by installing and using electric heaters inside the facilities. However, it is very difficult to manage the room temperature stably by the heaters. In addition, unlike the temperature inside the facility, silkworms could undergo severe temperature changes as the inside of the rearing tray could not be warm enough. In this study, in order to improve the previous heating method, the new rearing method that directly heats the bottom of the rearing tray was developed. Compared to the previous room-heating system, the novel heater-installed tray (HIT) system significantly reduced the change in temperature during the experimental period. In addition, the number of days of silkworm growth up to harvest was shortened, which was effective in growth performance, and it was also found that silkworms grew more uniformly in HIT system than in previous system. Moreover, as the heater tubes were installed directly under the rearing tray, it quickly dried mulberry leaves and silkworm feces after feeding, and as a result, the environment in the tray was greatly improved with decrease the labor of breeder. In conclusion, these results suggest that the heater-installed rearing tray method greatly improves silkworm quality, increases weight of silkworms, and final profits compared to the previous room heating system with electric heaters.