• Title/Summary/Keyword: heating performance

검색결과 1,973건 처리시간 0.026초

공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006)

  • 한화택;신동신;최창호;이대영;김서영;권용일
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.

하수처리장 바이오가스 플랜트의 가스엔진 최적 운영 방안 (Optimal Operation of Gas Engine for Biogas Plant in Sewage Treatment Plant)

  • 김길정;김래현
    • 에너지공학
    • /
    • 제28권2호
    • /
    • pp.18-35
    • /
    • 2019
  • 한국지역난방공사에서 난지 물재생센터의 하수처리 설비로 부터 발생하는 $45,300m^3$/일의 바이오가스를 연료로 1,500 kW, 2대 규모의 엔진 발전기를 운영하고 있다. 그러나 바이오가스 발전 플랜트의 실제 운영 경험이 미미하고, 축적된 기술 및 노하우 부족으로 가스엔진의 잦은 고장과 정지로 많은 경제적 손실이 발생하고 있다. 따라서 이 발전 플랜트의 안정적인 운영을 위한 기술적 근본 대책 마련이 필요한 실정이다. 본 연구에서는 난지 물재생센터의 하수처리장에서 발생하는 바이오가스를 이용한 가스엔진 플랜트의 일련의 공정상의 문제점을 확인하고, 각 단계별 문제점을 최소화 하여 실제 운전의 최적화 방안을 마련하였다. 먼저 고장 정지의 주요 원인인 발생가스의 정제를 위해 현재 사용 중인 활성탄에 대한 성분분석 및 흡착실험을 통해 활성탄의 흡착능력 품질 기준 마련을 위한 여건을 조성하였다. 또한, 불순물을 최소화하기 위한 활성탄의 교체주기의 기준수립, 황화수소 측정주기 강화, 활성탄 국산화, 설비개선 등 바이오플랜트 운영기준 강화 및 개선방안을 적용하여 실제운전에 적용하였다. 그 결과 가스엔진 1호기는 530%, 2호기는 250%의 정상운전 가동시간이 증가되는 운영실적을 보였다. 또한 통풍구의 설비개선을 통해 작업공정을 줄이고, 정상 운전시간과 가동률을 높일 수 있었다. 경제적으로도 77,000천원/년의 매출증대 효과를 나타냈다, 이와 같이 운영기준의 강화 및 개선방안을 적용하여, 바이오가스 플랜트의 고장 정지를 줄이고 가동률을 높여, 안정적인 운영을 하는 것이 현실적인 바이오가스 플랜트의 최적 운영방안으로 판단된다.

온실에서 상추와 배추를 이용한 DME 원료 난방 효율분석 (Assessment of the Effect of Dimethyl Ether (DME) Combustion on Lettuce and Chinese Cabbage Growth in Greenhouse)

  • 쟌타 구마 바삭;와카스 카심;파와드 칸;프랑크 갼 오시레;이용진;에린지 아루모지;박지훈;조원준;김현테
    • 생물환경조절학회지
    • /
    • 제28권4호
    • /
    • pp.293-301
    • /
    • 2019
  • 본 연구는 온실의 온도와 $CO_2$농도를 높이기 위해 DME버너용 연료로 DME가스를 사용했을 때 DME 연소가스의 성능을 결정하고 겨울에 상추와 양배추의 엽록소 함량 그리고 무게와 건조무게에 대한 영향정도를 조사하기 위해 수행되었다. 각각 온실1과 온실2에 처방 된 DME-1과 DME-2 처방은 덕트의 평균 DME 유량 $17.4m^3min^{-1}$$10.2m^3min^{-1}$으로 구성됐으며, 대조군(DME-3)으로 남겨진 온실3에는 DME 가스가 공급되지 않았다. DME 공급 시간은 각각 주차 별로 1주차는 하루당 0.5시간, 2주차는 1시간, 3주차는 1.5시간, 4주차는 2시간으로 설정하였다. 각각 처방마다 엽록소 함량과 상추와 배추의 건조 전, 후 중량을 측정했으며, 연구결과 무처리구인 온실3과 비교하여 온실1과 온실2의 $CO_2$ 농도는 각각 265%, 174% 증가하였고, 온도의 경우 $4.8^{\circ}C$, $3.10^{\circ}C$ 상승하였다. DME 가스를 제외한 다른 조건이 같은 온실에서 재배된 상추와 양배추의 엽록소 함량과 생체중, 건물중은 온실1에서 (유의적으로) 가장 높았으며, 온실2는 대조구 온실보다 높았다. 이러한 결과는 DME가스 연소에 의한 $CO_2$ 농도 차이에 기인된 것으로 판단된다. 일반적으로 가스연소에 의해 발생되는 유해가스 증상은 나타나지 않았으며 동절기 난방과 $CO_2$ 공급이 동시에 필요할 경우 DME가스가 기존의 경유 또는 LPG 등을 대체할 수 있는 가능성을 확인하였다. 향후 정밀한 연구를 통하여 효율적인 난방방식으로의 검토가 적극 필요하다고 판단된다.