• Title/Summary/Keyword: heating oil tax

Search Result 3, Processing Time 0.018 seconds

A Study on the Night Thermal-storage Power Service : Sustainability and Energy Security (심야전력제도의 문제점과 개선 방향 : 경제성·환경성·형평성 및 에너지 안보)

  • Cho, Young-Tak;Kim, Chang-Seob
    • Environmental and Resource Economics Review
    • /
    • v.17 no.2
    • /
    • pp.419-455
    • /
    • 2008
  • This paper analyses the Night Thermal-storage Power Service(NTPS) from the perspective of sustainability. It investigates the economic, environmental and social aspects of NTPS, thereby reveals that NTPS triggers the inefficient use of fuel, the increase of carbon dioxide emission and the increase of cross subsidy between consumers. This paper also analyses NTPS from the perspective of energy security. It investigates how NTPS makes LNG demand volatile in winter, thus threatens our energy security. According to the analysis, NTPS directly violates two basic principles of national energy policy; Sustainability and Energy Security. To solve these problems, not only the harmonized adjustment of Heating Oil Tax and Electric Power Rates is needed to curb the rapier increase of NTPS, but also another separate policy is necessary for converting the electric heating system based on NTPS into the one based on Heating Oil.

  • PDF

Analysis of New & Renewable Energy Application and Energy Consumption in Public Buildings (공공건축물의 신재생에너지 적용과 에너지 사용량 분석)

  • Lee, Yong-Ho;Seo, Sang-Hyun;Kim, Hyung-Jin;Cho, Young-Hum;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.153-161
    • /
    • 2012
  • This study conducted a survey and field investigation on the application of the Public Obligation System for new & renewable energy in public buildings, as well as energy consumption of each building according to their uses. The findings are as follows: (1) Since the introduction of the Public Obligation System (until June 30, 2011), there was average 1.4 new & renewable energy facilities established at 1,433 places. Preference for solar energy facilities was the highest at 57.8%. (2) The revised act sets the obligatory supply percentage of new & renewable energy for each public building: it is 9.0% for a tax office, 4.2% for a dong office, 8.2% for a public health center, and 12.6% for a fire station. All the public buildings except for fire stations failed to meet 10% expected energy consumption, a revised standard. (3) Energy consumption of each public building was 120.6TOE for a tax office, 124.3TOE for a dong office, 166.4TOE for a public health center, and 174.6TOE for a fire station. The energy consumption was comprised of 80% electric power, 18% urban gas, and 1% oil. (4) Electric power consumption per person in the room was high at a dong office, and fuel consumption per person in the room was high at a public health center. In addition, electric power consumption per unit space was high at a public health center, and fuel consumption per unit space was high at a fire station. (5) In all the four public buildings, power load had the highest basic unit percentage at average 55%, being followed by heating load (21.2%), cooling load (15%), and water heating load (7%). A tax office and fire station had 2% load due to cooking facilities.

Heat Pump System Using Heated Effluent of Thermal Power Generation Plant as a Heat Source (해수를 이용한 화력발전소 폐열회수 히트펌프 시스템)

  • Ryou, Y.S.;Kang, Y.K.;Kim, Y.H.;Jang, J.K.;Kim, J.G.;Lee, H.M.;Kang, G.C.;Nah, K.D.;Huh, T.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.190-190
    • /
    • 2011
  • In South Korea the gross generation and heated effluent of power generation plant was 259 TWh and 4.73 billion tons in 2008. And then the waste heat from power generation was 388 TWh. It shows that the efficiency of thermal power generation plant is about 40%. Therefore to reduce $CO_2$ emission from thermal power generation plant, the energy of this heated effluent must be reused to heat buildings or farm facilities. In South Korea horticultural facilities of about 25% are heated in winter season. Total area of greenhouses which are heated is about 13,000 ha. Total heat amount needed to warm greenhouse of 13,000 ha in winter season is only 3.4% of total waste heat from power generation plant. In this study a heat pump system was designed to reuse the waste heat from power generation. Especially new heat exchanger was developed to recover the thermal energy from waste water and this model considered anti-corrosion against sea water and low cost for economic feasibility. This heat recovery system was installed in mango growing greenhouse around thermal power generation plant in Seogwipo-city, Jeju Special Self-Governing Province. The result of preliminary test shows that the heating cost of about 90% is saved as compared to boiler using tax free light oil as a fuel.

  • PDF