• 제목/요약/키워드: heating mortar

검색결과 81건 처리시간 0.027초

예비가열법에 의한 폐콘크리트 재생골재의 물성개선 (The Improvement of Properties of Recycled aggregates using Concrete Waste by Pre-heating Method.)

  • 최현수;김효열;최봉철;강병희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.73.2-79
    • /
    • 2003
  • The purpose of this study is to provide the basic data on the optimum method for interfacial separation for an effective recycle of concrete waste by using the thermal properties of concrete. Therefore, this study is proceeded by dividing the interface of concrete into cement paste and fine aggregates or mortar and coarse aggregate, considering the aspect of recycled cement and aggregate as the recycling use of concrete waste. As results of the experiment, in case of recycle cement, the interfacial separation is easily appeared, but it is shown that the mixed amount of powder included in fine aggregate doesn't greatly decrease. But, in case of recycle coarse aggregate, the effect of interfacial separation by preliminary heating is predominant. Especially, the bonding rate of mortar is the lowest when it is heated 5 times for 120 minutes at $300^{\circ}C$. Hence, it is considered that it will be an excellent effect of quality control when the results of this study is applied to a manufacturing system of recycle coarse aggregate which is about to put into practical use.

  • PDF

PCM을 혼입한 시멘트 모르타르의 열적성능에 관한 연구 (A Study on Thermal Performance of Cement Mortar with PCM)

  • 김보현;이한승
    • 콘크리트학회논문집
    • /
    • 제23권4호
    • /
    • pp.521-528
    • /
    • 2011
  • 이 논문은 최근 가속진행 되고 있는 에너지 고갈 및 이산화탄소($CO_2$) 배출 방지대책에 대한 하나의 방안으로서 우수한 잠열 성능을 가진 PCM(phase change materials)을 모르타르에 혼입하고 실험을 통해 PCM의 적정 혼입량 및 모르타르 물성, 성능, 바닥 방식에서의 냉 난방식 적용에 대한 PCM의 효율적인 용융점 등 을 파악하였으며 자체 열적 성능 실험을 통해 열 전달 및 잠열 성능을 확인하였다. 또한 실험에서 도출해 낸 결과에 의해 Fourier의 열법칙을 이용하여 PCM 혼입량별 열전달량과 온도 구배 식을 제안하고 이를 분석하였다. 따라서 이 논문의 결과를 근거로 PCM의 건축물에서의 적용성을 파악하고 냉 난방 에너지 저감 효과를 기대할 수 있는 기초적 자료로서의 근거를 도출하는데 큰 의미를 두었다. 이 실험 결과 PCM 모르타르의 우수한 냉 온 축열 성능을 도출 할 수 있었으며 이를 통해 냉 난방기 On-Off 작동 조절에 의한 에너지 저감 및 그에 따른 $CO_2$ 저감에 대한 가능성을 확인 할 수 있었다.

PCM을 혼입한 방통 모르타르의 열적 성능 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Thermal Performance of Floor mortar with PCM)

  • 김보현;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.5-6
    • /
    • 2011
  • CO2 reduction is the most urgent issue the world is facing. So, there should be a measure to reduce the CO2 emission in construction industry which has more released CO2 gas than other industries. CO2 emission of building depend on using energy. Then efficient energy use process working efficiently at CO2 reduction. Therefore In this study, author find the technical possibility of saving the building energy using the PCM which is able to control heat, storage heat and potential heat. So, it considered that apply to floor heating type which is major heating system of living space in Korea. And evaluate the Using possibility.

  • PDF

폐CNT를 혼입한 시멘트 복합체의 강도 및 열전달 특성에 대한 기초적 연구 (Fundamental Study on the Strength and Heat Transferring Charcteristic of Cement Composite with Waste CNT)

  • 구현철;김운학;오홍섭
    • 한국건설순환자원학회논문집
    • /
    • 제10권1호
    • /
    • pp.66-73
    • /
    • 2022
  • 동절기 콘크리트 포장체의 블랙아이스 발생위험을 낮추고 동결에 의한손상을 방지할 목적으로 콘크리트의 전도저항성을 활용하여 자기 히팅 콘크리트를 개발하고자 하였다. 이를 위하여 분말형과 액상형 폐CNT와 전도촉진을 위해 폐음극재를 사용하여 강도변화와 온도 발열특성을 평가하고자 하였다. 액상형 폐CNT가 모르타르내에서 분산정도가 효과적이고, 강도저하가 작게 발생하는 것으로 분석되었다. 또한 모르타르에 스틸매쉬, 구리포일과 구리선을 전극으로 적용하여 DC 24 V를 공급하였으며, 폐CNT, 폐음극재과 탄소섬유 혼입율에 따른 온도변화 특성을 평가하였다. 또한 선정된 최적배합으로부터 전극간격에 따른 온도 특성을 평가하여 AC 50 V 까지는 전극간격 100 mm 까지는 충분한 발열 특성을 갖는 것을 확인하였다.

열을 받은 에폭시 수지 모르터의 강도에 관한 연구 (A Study on the Strengths of Epoxy Resin Mortar under Heat Exposure)

  • 연규석;강신업
    • 한국농공학회지
    • /
    • 제24권4호
    • /
    • pp.92-98
    • /
    • 1982
  • The major objective of this study was to investigate the heat resistance of epoxy resin mortar. For this purpose, these tests of compressive and bending strength were accomp- olished with various heating temperature (40˚C, 60˚C, 80˚C, 100˚C, 120˚C), and with various mixing ratio (1: 2, 1: 4, 1: 6, 1: 8, 1:10, 1:12, 1:14). The exprimental resin was to be Epi-Bis type epoxy resin, which is widely used as construction materials. The results obtained are summarized as follows; 1. The variations of color tone started to begin at 60˚C, and it has come out very heavy at 120˚C. It was assumed that the decrement of weight resulted from carbonization were about 0.22% at 100˚C, and about 0.34% at 120˚C. 2. The compressive and bending strength were increased with temperature rise up to 80˚C, but these were made rapid decrease when the given temperature was over. And so, the mean decrement of compressive and bending strength at 120˚C reached up to 35.5% and 26.4%, respectively. 3. The regression equation between compressive and bending strength for epoxy resin mortar under heat exposure were obtained as follows; od=0. 371oc+39. 23 (r=0. 986) And the estimated value of bending strength was corresponded to about 37 percent in comparing with that of the compressive strength. 4. Consquently, the heat resistance temperature of epoxy resin mortar was to be around 80˚C, and it was generally very low values. But it was regarded that the epoxy resin mortar will not be difficult with materials of civil engineering works and agricultural structures.

  • PDF

Recovery of mortar-aggregate interface of fire-damaged concrete after post-fire curing

  • Li, Lang;Zhang, Hong;Dong, Jiangfeng;Zhang, Hongen;Jia, Pu;Wang, Qingyuan;Liu, Yongjie
    • Computers and Concrete
    • /
    • 제24권3호
    • /
    • pp.249-258
    • /
    • 2019
  • In order to investigate the strength recovery of fire-damaged concrete after post-fire curing, concrete specimens were heating at $2^{\circ}C/min$ or $5^{\circ}C/min$ to 400, 600 and $800^{\circ}C$, and these exposed specimens were soaked in the water for 24 hours and following by 29-day post-fire curing. The compressive strength and split tensile strength of the high-temperature-exposed specimens before and after post-fire curing were tested. The proportion of split aggregate in the split surfaces was analyzed to evaluate the mortar-aggregate interfacial strength. After the post-fire curing process, the split tensile strength of specimens exposed to all temperatures was recovered significantly, while the recovery of compressive strength was only obvious within the specimens exposed to $600^{\circ}C$. The tensile strength is more sensitive to the mortar-aggregate interfacial cracks, which caused that the split tensile strength decreased more after high-temperature exposure and recovery more after post-fire curing than the compressive strength. The mortar-aggregate interfacial strength also showed remarkable recovery after post-fire curing, and it contributed to the recovery of split tensile strength.

Quality Improvement of Recycled Aggregates from Waste Concrete by the heating and grinding

  • Kim, Hyung-Seok;Han, Gi-Chun;Ahn, Ji-Whan;Park, Jae-Seok;Kim, Hwan;Kim, Kyung-Soo
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.571-575
    • /
    • 2001
  • To examine the grinding effect through preheating of waste concrete as a way of retrieving coarse aggregates from waste concrete, the removal rates of cement mortar and paste of both recycled aggregates and heated and grinded ones were investigated. As the preheating temperature increased, the removal rate of cement mortar from waste concrete was raised, and this kind of removal hardly affected the abrasion rate and specific gravity of aggregates. On the other hand, when it was treated over 40$0^{\circ}C$ of preheating temperature, the absorptance was reduced to less than 2.17, and cement mortar was effectively separated from waste concrete. It could meet the Korean Standards on recycled aggregates for concrete, and it is expected to expand the scope of utilization by making it possible to retrieve the aggregates which have the properties close to natural aggregates.

  • PDF

마이크로파를 이용한 저열 포틀랜드(4종)시멘트 모르터의 조기강도 추정에 관한 실험적 연구 (An Experimental Study on the Strength Estimation of Belite Cement Mortar by Microwave Heating)

  • 김민석;정근호;이영도;정재영;정상진
    • 한국건축시공학회지
    • /
    • 제1권2호
    • /
    • pp.179-184
    • /
    • 2001
  • The most recent building trend is going large, high rise, high strength as overlarge project is developing in domestic construction business. Belite cement has properties like low heat, excellent long term strength, and durability without admixture(fly ash, silica fume). so, Beilte cement is suitable for mass structure which is needed high strength, high fluidity and low heat property. This study is to examine the possibility if site adoption microwave-use early strength estimation method. Based on the existed study related the portland cement, the interrelation between Belite cement and microwave-use early strength estimation method is required. In this study, interrelation between mortar and Evaluating strength estimation method is investigated before the concrete experiment.

  • PDF

온돌바닥 모르터의 건조수축보상을 위한 팽창제의 품질특성 연구 (A Study on the Quality Properties of the Expansive For Dry-Shrinkage Compensation of the Floor Mortar)

  • 이웅종;이종열;정연식;이순기;정성철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.155-160
    • /
    • 2000
  • In this paper, we investigated quality properties for the expansive of the CaO-$CaSO_4$ family which used to compensate dry-shrinkage in the floor mortar of On-Dol heating System. This experimental study established the mix condition with quantity of the expansive and is to investigate the relativity between the compress strength and the length change and the relativity between the chemical properties and the length change with the analysis of the physical and chemical properties. As a result of the study, the expansive is controlled by more the CaO than the $CaSO_4$. The relativity between the compress strength and the length change is expressed by exponential function, showing that if the expansive performance is increased, the compress strength is decreased. And the relativity between the chemical properties and the length change is only relative the quantity of the F-CaO among the chemical properties, is expressed by the second order function, showing that if the F-CaO is increased, the expansive performance is increased.

  • PDF

골재 혼입 유무가 고온수열 콘크리트의 강도 특성에 미치는 영향 (Effects of Aggregate Mixing on the Strength Properties of Fire-Damaged Concrete)

  • 권현우;김영민;허영선;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.133-134
    • /
    • 2021
  • In this study, the effects of aggregates on the properties of concrete as a study to determine the mechanical properties of high-temperature damaged concrete were examined. The samples to be reviewed are cement paste, mortar, and concrete, and the strength characteristics were reviewed after heating the compression strength and tensile strength properties. The increase in magnetic shrinkage at around 100℃ showed a significant drop in strength in mortar, which does not contain aggregates or has a small diameter, and after 300℃, concrete showed a sharp drop in strength due to the hydration and aggregation of cement.

  • PDF