• Title/Summary/Keyword: heating method

Search Result 2,729, Processing Time 0.035 seconds

Anti-icing Method of Heated Walkway in Ice Class Ships: Efficiency Verification of CNT-based Surface Heating Element Method Through Numerical Analysis

  • Woo-Jin Park;Dong-Su Park;Mun-Beom Shin;Young-Kyo Seo
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.215-224
    • /
    • 2023
  • While melting glaciers due to global warming have facilitated the development of polar routes, Arctic vessels require reliable anti-icing methods to prevent hull icing. Currently, the existing anti-icing method, i.e., the heating coil method, has disadvantages, such as disconnection and power inefficiency. Therefore, a carbon nanotube-based surface heating element method was developed to address these limitations. In this study, the numerical analysis of the surface heating element method was performed using ANSYS. The numerical analysis included conjugate heat transfer and computational fluid dynamics to consider the conduction solids and the effects of wind speed and temperature in cold environments. The numerical analysis method of the surface heating element method was validated by comparing the experimental results of the heating coil method with the numerical analysis results (under the -30 ℃ conditions). The surface heating element method demonstrated significantly higher efficiency, ranging from 56.65-80.17%, depending on the conditions compared to the heating coil method. Moreover, even under extreme environmental conditions (-45 ℃), the surface heating element method satisfied anti-icing requirements. The surface heating element method is more efficient and economical than the heating coil method. However, proper heat flux calculation for environmental conditions is required to prevent excessive design.

Characteristics of plasma sprayed composite YSZ/Ni-Cr resistant heating coatings (YSZ/Ni-Cr 저항 발열 복합용사피막의 특성)

  • 김병수;박경채;김태형;양병모
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.111-113
    • /
    • 2003
  • The existing heating unit is indirect-heating method that make use or the nichrome wire or halogen lamp. The indirect-heating method has the demerits of long warming time, high power consumption and many organization parts. In this study, the heating unit of direct-heating method manufactured as being the thermal spray coating of conductive heating material on the surface of heating unit in order to improve the demerits of indirect-heating method. And YSZ added Ni-20Cr that had moderate electrical resistivity was chosen of the conductive heating material.

  • PDF

Intermittent Heating and Cooling Load Calculation Method -Comparing with ISO 13790

  • Lee, Sang-Hoon
    • Architectural research
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • College of Architecture, Georgia Institute of Technology, Atlanta, GA, US Abstract The intermittent heating and cooling energy need calculation of the ISO 13790 monthly method was examined. The current ISO 13790 method applies a reduction factor to the continuous heating and cooling need calculation result to derive the intermittent heating and cooling for each month. This paper proposes a method for the intermittent energy need calculation based on the internal mean temperature calculation. The internal temperature calculation procedure was introduced considering the heat-balance taking into account of heat gain, heat loss, and thermal inertia for reduced heating and cooling period. Then, the calculated internal mean temperature was used for the intermittent heating and cooling energy need calculation. The calculation results from the proposed method were compared to the current ISO 13790 method and validated with a dynamic simulation using EnergyPlus. The study indicates that the intermittent heating and cooling energy need calculation method using the proposed model improves transparency of the current ISO 13790 method and draws more rational outcomes in the monthly heating and cooling energy need calculation.

Development of a Method to Estimate the Seasonal Heating Load for Plastic Greenhouses (플라스틱 온실의 기간난방부하 산정 방법 개발)

  • Nam, Sang Woon;Shin, Hyun Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.37-42
    • /
    • 2015
  • In order to provide fundamental data for the creation of environmental design criteria for horticultural facilities, we developed a method to easily calculate the seasonal heating load applying heating degree-hour while taking into account heating load reductions due to solar radiation in the daytime, and reviewed through greenhouse heating experiments. Heating experiments and measuring meteorological environments were carried out in three greenhouses located at Buyeo, Cheonan, and Buan, and we derived reduction factors of seasonal heating load according to hours of sunshine. Daily mean hours of sunshine during the experiment period in each of the greenhouse was 4.0 to 8.3 hours, and the reduction factor of seasonal heating load was 0.64 to 0.85, has been shown to decrease linearly with the increase in hours of sunshine. A method to estimate the seasonal heating load for greenhouses was developed using the reduction factor of seasonal heating load derived from the greenhouse heating experiment, including the adjustment factor of seasonal heating load according to hours of sunshine. The developed method was validated through heating experiments in a greenhouse located at Cheonan. Greenhouse seasonal heating loads calculated by the method developed in this study were analyzed to show the estimate error of 1.2 to 5.0%. It showed that the accuracy increased 2.3 times more than when using the heating load reduction factor of 0.75 applied uniformly in previous studies. Thus, the calculation method of seasonal heating load for greenhouses considering hours of sunshine developed in this study could be utilized for energy estimation, management planning, and economic evaluation in greenhouse design.

Energy Performance Analysis Program with Heating methods of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방용 자동온도조절기의 난방방식에 따른 에너지성능 해석용 프로그램에 관한 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob;Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.381-386
    • /
    • 2008
  • In this study, the energy characteristic of automatic thermostatic valves according to each heating method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on heating method, valve's control method, outdoor air condition, supply heating water temperature, supply flow rate are performed to compare energy characteristic, respectively.

  • PDF

Simulation of Line Heating by High frequency Induction Heating (고주파 유도 가열에 의한 선상가열 시뮬레이션)

  • 김호경;장창두
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.1
    • /
    • pp.80-85
    • /
    • 2003
  • In this study, we developed an analysis method of plate forming by induction heating, verifying the effectiveness of the present method through a series of experiments. The phenomena of the induction heating involves a 3D transient problem, coupled with electromagnetic, heat transfer, and elastoplastic large deformation analyses. To solve the problem, or present an appropriate model and an integrated system. Using the present analysis model, or can estimate the plate deformation in heating without experiments and simulate the plate bending process of induction heating.

Simulation of Plate Deformation due to Triangle Heating Using Inherent Strain Method (고유변형도법을 이용한 삼각가열에 의한 판 변형의 시뮬레이션)

  • Jang, Chang-Doo;Ko, Dae-Eun;Ha, Yun-Sok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.6
    • /
    • pp.703-709
    • /
    • 2008
  • In the shipyard, line heating and triangle heating are two major processes for forming curved plates in various shapes. While there have been many studies on line heating, triangle heating has been rarely studied due to its complicated heating process with irregular multi-heating paths and highly concentrated heat input. As the triangle heating process is one of the most labor-consuming jobs in shipyards, it is essential to study the automation as well as improvement of triangle heating process in order to increase hull forming productivity. In this study, a pioneering attempt to simulate triangle heating was made. A circular disk-spring model was proposed for elasto-plastic analysis procedure of triangle heating and the inherent strain method was also used to analyze the deformation of plates. Simulation results were compared with those of experiments and showed good agreement. It is shown that the present approach including analysis model used in this study is effective to simulate the triangle heating for plate forming process in shipbuilding.

The Energy Analysis and Control Characteristics of a Hot Water Heating System for Apartment Houses (공동주택용 온수난방 시스템의 에너지해석 및 제어특성)

  • 장효환;안병천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.76-87
    • /
    • 1996
  • Energy analysis for the hot water heating control system of apartment house complex is accomplished by computer simulation. Mathematical model of a boiler, pipe network and a unit-house is developed. The effects of heating control methods on the heating performance and energy consumption of the system are investigated. The heating control methods considered in this study are a continuous heating control, and on-off heating control and an intermittent heating control methods. For each control method, the effects of an outdoor temperature, indoor temperature sensing position and the capacities of the boilers and circulating pumps on the heating performance and energy consumption are obtained and "the best" control method is recommended.commended.

  • PDF

Experimental Study on Performance Evaluation of System A/C using PWM or Inverter Method (Heating Characteristics at Low Temperature Conditions) (PWM 방식과 인버터 방식을 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(난방저온 특성))

  • 김대훈;전용호;권영철;이윤수;문제명;홍주태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.551-556
    • /
    • 2003
  • The present study concerns an experiment on the heating characteristics of a system air-conditioner (A/C) using PWM method or inverter method at low temperature con-ditions. The compressors used are digital scroll type and BLDC inverter type. Under the low outside temperature condition, -5$^{\circ}C$, -1$0^{\circ}C$, -15$^{\circ}C$, heating capacities and COPs are mea-sured by the psychometric calorimeter using air enthalpy method. Also, outlet air temperatures at heating operation mode are measured at -5$^{\circ}C$, -1$0^{\circ}C$ and -15$^{\circ}C$. Experimental results show that COPs of the system A/C using a PWM method are more effective than those of the inverter method at heating operation mode. Although the heater is on, COPs of PWM method are similar to those of BLDC inverter method. Moreover, the heating capacities of PWM method at -5$^{\circ}C$, -1$0^{\circ}C$ and -15$^{\circ}C$ are larger about 10~20% and outlet air tempe-rature at -15$^{\circ}C$ is larger about 10%, compared to the inverter method.

Localized Induction-Heating Method by the Use of Selective Mold Material (재료의 선택적 사용에 의한 금형의 국부적 유도가열기법)

  • Park, Keun;Do, Bum-Suk;Park, Jung-Min;Lee, Sang-Ik
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.168-171
    • /
    • 2009
  • High-frequency induction is an efficient way to heat mold surface by electromagnetic induction in a non-contact procedure. Though the induction heating has an advantage in terms of its rapid-heating capacity on the mold surface, it still has a restriction on mold temperature control due to geometric restriction of an induction coil according to the mold shape. It has been recently applied to the injection molding of thin-walled parts or micro/nano structures. For localized induction heating, an injection mold composed of ferromagnetic material and paramagnetic material is used. The electromagnetic induction concentrates on the ferromagnetic material, from which we can selectively heat for the local mold elements. The present study proposed a localized induction heating method by means of selective use of mold material. The feasibility of the proposed heating method is investigated through the comparison of experimental observations according to the mold material.

  • PDF