공동주택에서 비난방세대가 미치는 열적 영향 (Analysis for Thermal Effect by an Unheated Housing Unit in Apartment)

  • 이은주;구준모;홍희기
    • 설비공학논문집
    • /
    • 제28권1호
    • /
    • pp.42-47
    • /
    • 2016
  • Adjacent housing units suffer inevitable thermal losses if an unheated unit exists in an apartment building. Thermal loss of the units adjoining the unheated apartment can be neglected because the contact area is small and insulators are located in the walls. When insulators are not included in the slab between the upper and lower units, 70% of the heat supplied by an Ondol system may be used in the original unit, but 30% is transferred to the unit on the lower floor. Another 30% can be obtained from the ceiling if the upper floor housing unit is heated. This strong thermal connection is a characteristic of Ondol heating in apartment buildings. When there is an unheated unit, the lower floor unit uses 42.3% more heating energy if there is no insulation and 19.5% if a 35 mm insulator is used as in the current guidelines. Therefore, much thicker insulation should be applied to weaken the thermal connection.

가용 동작 주파수 범위를 고려한 FB-SRC 기반 IH 쿡탑 시스템의 전력 제어 방안 (Power Control Method for FB-SRC IH Cooktop System Considering Limited Switching Frequency Range Condition)

  • 황윤성;이주승;강승현;권만재;장은수;이병국
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.256-264
    • /
    • 2022
  • The frequency power control method (FCM) which has a wide operating frequency range is adopted for induction heating (IH) cooktops. When FCM is applied to the full-bridge series resonant converter (FB-SRC) based IH system, high-frequency switching of the inverter is required compared to the half-bridge SRC (HB-SRC)-based IH system. Therefore, the switching loss of the inverter increases, and applying FCM under the condition that the inverter operating frequency range is limited is difficult. Therefore, this paper proposes a control strategy with the phase shift power control method considering that limited frequency conditions are presented. Loss analysis following the control method is performed through simulation and mathematical analysis. In addition, the validity of the proposed control strategy is verified by analyzing the heating performance following the control method through the test results of the 3,200[W] prototype.

태양열이용 Baffle형 축열탱크를 갖는 온수난방시스템의 열성능 해석 (Analysis of Thermal Performance of Solar Hot-Water and Heating System with Baffle Storage Tank)

  • 서정세;이중섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.768-773
    • /
    • 2009
  • A numerical study has been performed to investigate the thermal Performance of Solar heating system with baffle type of storage tank by using the commercial code TRNSYS. As a result, the solar fraction depends strongly on the efficiency and heat loss coefficient of solar collector as well as the heating capacity of house and the water temperature supplied to the shower. In addition, the solar fraction has been basically ranked to higher level in baffle type of storage tank than typical type of single storage tank for the range of operation condition.

  • PDF

바닥충격음 완충재의 동탄성계수 특성 및 측정 영향인자 (A Study On the Property and Influence Factor in Measuring of the Dynamic Stiffness of Damping Materials)

  • 김경우;최현중;강재식;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1256-1259
    • /
    • 2006
  • The purpose of this study was to investigate the current status and influence factor in measuring the dynamic stiffness of damping materials. The property of the dynamic stiffness of damping materials was tested and analysed in condition such as the size of test samples and the change of relative humidity in heating chamber. Test results showed that the dynamic stiffness of after-heating was lower than that of before-heating in most samples and the change of relative humidity in heating chamber got little influence of the dynamic stiffness. The resonant frequency of test sample decreased $2{\sim}7Hz$ as the decrease of the size of sample. Because it was increased that total mass per unit area of sample, the change of dynamic stiffness had little influence.

  • PDF

운전 조건에 따른 PEMFC 스택 열 관리 (The Heat Management of PEM Fuel Cell Stack)

  • 손익제;이종현;남기영;고재준;안병기
    • 한국수소및신에너지학회논문집
    • /
    • 제21권3호
    • /
    • pp.184-192
    • /
    • 2010
  • PEM fuel cell produces electric power, water and heat by the electrochemical reaction of hydrogen and oxygen. The heating value is dependent on the molar enthalpy of vaporization of product water and the performance loss. In this paper, the heating value of fuel cell stack has been studied under various stack operating temperatures to achieve more efficient heat management. A technology using the molar enthalpy of vaporization of product water is suggested to reduce heat-up time during start-up of a fuel cell vehicle.

Fracture toughness of high performance concrete subjected to elevated temperatures Part 2 The effects of heating rate, exposure time and cooling rate

  • Zhang, Binsheng;Cullen, Martin;Kilpatrick, Tony
    • Advances in concrete construction
    • /
    • 제5권5호
    • /
    • pp.513-537
    • /
    • 2017
  • In this study, the fracture toughness $K_{IC}$ of high performance concrete (HPC) was investigated by conducting three-point bending tests on a total of 240 notched beams of $500mm{\times}100mm{\times}100mm$ subjected to heating temperatures up to $450^{\circ}C$ with exposure times up to 16 hours and various heating and cooling rates. For a heating rate of $3^{\circ}C/min$, $K_{IC}$ for the hot concrete sustained a monotonic decrease trend with the increasing heating temperature and exposure time, from $1.389MN/m^{1.5}$ at room temperature to $0.942MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.906MN/m^{1.5}$ for 8-hour exposure time and $0.866MN/m^{1.5}$ for 16-hour exposure time. For the cold concrete, $K_{IC}$ sustained a two-stage decrease trend, dropping slowly with the heating temperature up to $150^{\circ}C$ and then rapidly down to $0.869MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.812MN/m^{1.5}$ for 8-hour exposure time and $0.771MN/m^{1.5}$ for 16-hour exposure time. In general, the $K_{IC}$ values for the hot concrete up to $200^{\circ}C$ were larger than those for the cold concrete, and an inverse trend was observed thereafter. The increase in heating rate slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.893MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.839MN/m^{1.5}$ for $10^{\circ}C/min$ for the hot concrete and from $0.792MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.743MN/m^{1.5}$ for $10^{\circ}C/min$ for the cold concrete after an exposure time of 16 hours. The increase in cooling rate also slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.771MN/m^{1.5}$ for slow cooling to $0.739MN/m^{1.5}$ for fast cooling after an exposure time of 16 hours. The fracture energy-based fracture toughness $K_{IC}$' was also assessed, and similar decrease trends with the heating temperature and exposure time existed for both hot and cold concretes. The relationships of two fracture toughness parameters with the weight loss and the modulus of rapture were also evaluated.

전기유도보일러의 발열효율개선을 위한 권선최적설계 (Optimal Design of a Coil for Improved Heating Efficiency of Electric Induction Boiler)

  • 김윤현;김솔
    • 한국산학기술학회논문지
    • /
    • 제20권3호
    • /
    • pp.476-482
    • /
    • 2019
  • 본 기후변화협약, 온실가스배출규제와 같은 규제적 규약들은 고효율 에너지 기자재 개발과 에너지의 효율적 이용을 촉진하는 촉매로 작용하고 있다. 에너지소비가 큰 분야 중 전열기기가 효율이 좋지 못한 편이다. 전기보일러는 히터에 물을 접촉시켜 순환시키는 방식을 주로 사용하고 있다. 기존 전기보일러를 활용할 경우 물의 미네랄이 고온의 히터와 접촉하여 탄화되어 흡착되는 과정에서 히터의 부식을 촉진시키고 히터의 효율을 저하시킨다. 이러한 이유로 에너지 효율이 높고, 전도나 대류가열보다 피가열물을 균일하게 가열시킬 수 있는 유도가열방식을 보일러에 적용시킨 전기유도보일러가 각광을 받고 있는데, 이 방식은 물이 담겨 있는 보일러 관로를 유도가열방식으로 가열하여 직접가열시 발생하는 문제를 해결시킬 수 있는 대안으로 인정받고 있다. 비교적 오랜 기간 유도가열에 대한 연구가 이루어졌음에도 불구하고 유도가열을 이용한 전열기술에 대한 연구결과는 그리 많지 않은 실정이다. 따라서 본 논문에서는 전기유도보일러의 발열효율을 개선하기 위하여 매개변수연구방법을 통하여 권선의 단면적, 권선의 수 및 권선의 겹수에 의한 영향을 유한요소법을 이용하여 해석하고 발열의 요소가 되고 있는 동손과 철손을 분석하여 발열을 극대화시킬 수 있는 권선설계방법으로 총손실이 최대가 되는 설계점을 찾는 방법을 제시하였다.

Heating and Cooling Load of Building according to Atrium Layout

  • Jeong, Nam-Young;Lee, Ji-Young;Chae, Young Tae
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.29-36
    • /
    • 2016
  • Purpose: The purpose of this study is to present basic data which would be applied on the early stage of the architectural design. And that determines the introduction of the atrium by comparing and analysing the environmental performance of atrium building. Method: The building forms are classified into low storied building, middle storied building and high storied building. This study compares and analyses energy performance of the standard building without atrium and the atrium building which has one-side, two-side, three-side, four-side, and linear atrium by measuring of annual heating and cooling load with EnergyPlus. Result: As a result of the analysis of the relative annual heating and cooling load by building type, it is shown that the fluctuation of cooling load in low storied building is large because heat storage in atrium affects building, and the fluctuation of heating load in high storied building is large owing to the effect of external wall area of atrium which makes heat loss. Especially, it indicated the largest annual heating and cooling load in four-side atrium of low storied building, and in one-side atrium of high storied building.

공동주택 단위난방부하 계산을 위한 단위동법 제안 (Proposal of Unit Building Method for Calculating Unit Heating Load of Apartment Houses)

  • 유호선;정주혁;문정환;이재헌
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.68-76
    • /
    • 2007
  • As an alternative approach to evaluate the unit heating load for apartment houses, we newly developed and proposed unit building method. The new method, which calculates the heating load of an apartment building as a whole, conceptually corresponds to integral analysis of building heat loss, while the existing unit apartment method to differential analysis. Four typical building models of Korean-style apartment house and two dynamic load calculation programs were selected to validate the present method under realistically imposed conditions. Eight sets of unit heating load calculated respectively by unit building and unit apartment methods showed excellent agreements regardless of building model and simulation program. It is expected that the unit building method can take the place of the unit apartment method due to fewer modeling assumptions as well as less computational efforts. Additional calculations to investigate the effects of various parameters on unit heating load yield good consistencies with known facts, and re-confirm the validity.

구리와 알루미늄 이종금속 판재간의 전기저항가열 표면마찰 스폿용접 특성 (Characteristics of Electric Resistance Heated Surface Friction Spot Welding Process of Copper and Aluminum Dissimilar Metal Sheets)

  • 순샤오광;진인태
    • 한국기계가공학회지
    • /
    • 제21권8호
    • /
    • pp.99-109
    • /
    • 2022
  • In this study, an electric resistance-heated surface friction spot-welding process was proposed and tested for the spot-welding ability of copper and aluminum dissimilar metal sheets using electric resistance heating and surface friction heating. This process has welding variables, such as the current value, energizing cycles, rotational speed, and friction time. The current value and energizing cycle can affect the resistance heat, and the rotational speed of the rotating pin and friction time influence frictional heat generation. Resistance heating before friction heating has a preheating effect on the Cu-Al contact interface and a positive effect on preventing friction heat loss during the friction stage. However, because resistance preheating can soften the copper sheet and affect the contact stress and friction coefficient, it has difficulties that may adversely affect frictional heat generation. Therefore, the optimal combination of welding variables should be determined through simulations and experiments of the spot-welding process to determine the effects of electric resistance preheating on the suggested process. Through this procedure, it is known that the proposed spot-welding process can improve the welding quality during the spot welding of Cu-Al sheets.