• Title/Summary/Keyword: heating load

Search Result 892, Processing Time 0.024 seconds

A Study on the Practical Use of Alternative Energy for Agriculture in Korea (우리나라 농업의 대체에너지 활동 실태에 관한 연구)

  • 홍지형
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.3
    • /
    • pp.81-90
    • /
    • 1993
  • Groundwater and animal wastes are typical example which are underutilized resources than their value in agriculture. This paper was to investigate the actual patterns of utilization of water curtain for greenhouses and methane gas utilization from swine wastes in a view point of promoting more efficient use of alternative energy. The results from measurements can be summarized as follows : 1.It was estimated that the maximum heating load per l0a was around 23,2804/hr and the heating load at January showed 3.93X 1064 respectively for strawberry greenhouses with insulation by the water curtain. 2.The average heating cost of the greenhouse with water curtain system amounted to about 75,000 Won per l0a. This result suggested that the greater cultivated area provides less heating cost. 3.The operating volume was about 73 percent of the optimum size of the digester. The net available methane gas rates of the produced gas remained close to 62 percent, But the conventional and small size of the digester was maintained at a lower level of around 20 to 29 percent. 4.It appeared that major problems of biogas production system were required to maintain the temperature of the fermentation above ambient temperature and the optimum volume of digester.

  • PDF

An Analysis of Heating and Cooling Loads by Insulated Shades and Control Method in an Energy Saving Apartment (에너지절약형 주택에서의 단열차양 적용과 제어방법에 따른 냉난방부하 분석)

  • Park, Sun-Hyo;Kwon, Kyung-Woo;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.392-397
    • /
    • 2010
  • Energy loss from windows accounts for large scores of heating and cooling loads also in energy saving apartments that is reduced over 30% of total energy consumption. Movable reflective insulations, insulation shutters, blinds, insulated shades are used to reduce energy loads from windows. In this study, energy saving performance of insulated shades was simulated by control methods. According to installation of insulated shades, heating loads were decreased about 10.5~11.3%, and cooling loads are decreased about 29.1~38.3% on an energy saving apartment. The heating peak load was reduced about 9.5% by insulated shades and the cooling peak load was reduced about 25.7~31.5%. In the case of insulated shades with automatic control system, simple time schedule control system would be more efficient than outdoor detection control system that should use several sensors.

Evaluation of Energy Consumption through Field Measurement at the Apartment Housing Unit Using Dynamic Flow Rate Balancing (실물실험을 통한 다이나믹 유량밸런싱 적용 공동주택 세대의 에너지소비량 평가)

  • Ryu, Seong-Ryong;Cheong, Chang-Heon;Cho, Hyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.15-20
    • /
    • 2016
  • Even though the control device of the heating system works well, insufficient water flow rates can degrade control performance and thermal comfort. The water flow rate should be adjusted appropriately to cope with the heating load of each zone. In order to solve these problems, a new balancing concept 'dynamic balancing' was proposed where a balancing valve opening can be automatically modulated according to the heating condition of the room. This study analyzed the effects of dynamic balancing upon indoor thermal environment and energy consumption in a radiant floor heating system through field measurement. Under part-load conditions, the use of a dynamic balancing is a more effective method to reduce energy consumption and to prevent a cavitation. Dynamic balancing is able to help boost the temperature of a room in the start-up period.

Heating and Cooling Load according to the Climatic Conditions of Foreign Cities (해외 주요 도시의 기후특성에 따른 최대공조부하 요소별 분석)

  • An, Seung-Hyun;Kim, Jong-Ho;Lee, Jung-Hun;Lee, Sang-Yup;Song, Doo-Sam
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.81-87
    • /
    • 2014
  • According to the domestic construction business will continue stagnant, many domestic construction companies are expanding their business into foreign countries. As results, building design guidelines including HVAC design for foreign countries considering the regional climate conditions are needed. Also, green building design strategies to minimize the heating and cooling load are key issue to win a contract in construction business in the world. In this study, peak heating and cooling loads were calculated for the representative cities in the world : Seoul, St. Petersburg, Singapore and Mecca. The analyzed building was a typical high-rise office building and the building envelope properties, indoor heat gain, residence and operating schedules were same in all cases. Only the weather conditions were different by cases.

Effect of Air-earth Heat Exchange System on Growth of Leafy Lettuce in Greenhouse (온실내 잉여에너지 이용을 위한 지중 열교환 시스템의 상추 재배 효과)

  • Paek, Yee;Jeon, Jong-gil;Yun, Nam-kyu;Kang, Geum-Choon;Lee, Si-Young
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.71-76
    • /
    • 2011
  • Earth to air heat exchangers made by iron, aluminium, copper and poly-ethylene pipe for single greenhouse heating were experimented and blowers. Earth to air heat exchanger was installed by pipelines in earth tube at 70cm depths and air blower was the heating capacity 3kW/h, As the result, Temperature difference due to temperature history of the inlet and outlet air on the various type in earth tube in greenhouse showed that air temperature at the various type in earth tube, comparison tube were make no difference respectively. Under the experimental condition, heat fluxes and heating load were showed 6,800Kcal/h, 19,699kcal/h generally yield of Lactuca Sativa cultured during days of sowing 90day in greenhouse using copper pipe was 170% incleased.

Characteristics of Thermo-Acoustic Emission from Composite Laminates during Thermal Load Cycles

  • Kim, Young-Bok;Park, Nak-Sam
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.391-399
    • /
    • 2003
  • The thermo-acoustic emission (AE) technique has been applied for nondestructive characterization of composite laminates subjected to cryogenic cooling. Thermo-AE events during heating and cooling cycles showed a Kaiser effect. An analysis of the thermo-AE behavior obtained during the 1st heating period suggested a method for determining the stress-free temperature of the composite laminates. Three different thermo-AE types classified by a short-time Fourier transform of AE signals enabled to offer a nondestructive estimation of the cryogenic damages of the composites, in that the different thermo-AE types corresponded to secondary microfracturing in the matrix contacting between crack surfaces and some abrasive contact between broken fiber ends during thermal load cycles.

A Study on the Envelop to Improve Interior Environment Performance of High-rise Residential Building (초고층 주상복합 건물의 실내 환경 성능 향상을 위한 외피부 개선방향에 관한 연구)

  • Park, Sang-Hoon;Cho, Ga-Young;Lee, Sun-Woo;Jo, Jae-Hun;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.306-309
    • /
    • 2006
  • The architectural difference between the existing residence and high-rise residential building causes changes on environmental conditions such as ventilation and insulation. The object of this study is to present the improvement on envelop of high-rise residential buildings to reduce heating and cooling load. To improve the environmental performance of envelop, it is necessary to modify envelop vent system and ensure intermediate space. In this study, the shape of vents in high-rise residential buildings has been inspected, and the survey about the interior environmental conditions related to the envelop of high-rise residential building has been conducted. Environmental measurement has been done to examine out door air quality for natural ventilation.

  • PDF

Transient Piezothermoelasticity of a Piezo Ceramic Plate Subjected to Antisymmetric Thermal Load and Symmetric Thermal Load (압전 Ceramics 평판의 비대칭열부하와 대칭열부하에 의한 과도 압전열탄성 해석에 관한 연구)

  • Kim, Gyeong-Seok;Choe, Jeong-Seok;Yang, Seung-Pil;Kim, Yong-Uk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.1
    • /
    • pp.133-143
    • /
    • 1997
  • Piezoelastic materials have recently attracted considerable attention because of their potential use in intelligent structural systems. In this paper, we treat a transient piezothermoelastic problem in a hexagonal plate of crystal class 6mm subjected to antisymmetric heating temperature. We analyze this problem by use of the potential function method. Numerical calculations are carried out for a cadmium selenide solid, and the results are presented graphically in comparison with those derived from the similar problem in a cadmium selenide plate subjected to symmetric heating temperature for a symmetry transient problem.

Revised NIOSH lifting equation의 현장 적용

  • 기도형;정민근;임종호
    • Proceedings of the ESK Conference
    • /
    • 1995.04a
    • /
    • pp.106-110
    • /
    • 1995
  • A local manufacturing companyin which low back pain(LBP) complaints were frequently reported was selected, and regularly perfomed lifting tasks were investigated using questionnaires and the 1991 NIOSH lifting guide. Among several processes of manufacture in the company, three processes-forming, heating and packing-were studied, where most of tasks were perfomed through manual materials handling (MMH). Questionnaire surveys showed that anthropometric data such as stature, weight and someatotype did not affect and weight of load influenced significantly the incidence of LBP, and workers who expwrienced LBP was older than the inexperienced. In addition, safety education conducted at the company was found to be ineffective in preventing LBP injuries. Lifting indexes(LI) was ranged from 0.86 to 17.0 with an average of 4.49, which revealed that tasks performing in the selected factory were in danger of LBP, and should be ertonomically redesigned. The critical factor reducing LI was found to be the horizontal component in all three processes, and most of weight of load was heavier than load constant(23kg) of the 1991 NIOSH lifting equation in heating process and packing.

  • PDF

Characteristics Analysis of Instantaneous Current Resultant Type Load Parallel High Frequency Resonant Inverter (순시전류합성형 부하병렬 고주파 공진 인버터의 특성해석)

  • 조규판;원재선;이봉섭;심광렬;배영호
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.293-296
    • /
    • 2002
  • This paper describes the instantaneous current resultant type load parallel high frequency resonant inverter consisting of three unit half-bridge serial and parallel resonant inverter can be used as power source of induction heating. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, the principle of basic operating and the its characteristics are estimated by the parameters such as switching frequency($\mu$), load resistance(λ). Experimental results are presented to verify theoretical discussion. This proposed inverter will can be practically used as a power supply in various fields as induction heating application, DC-DC converter etc.

  • PDF