• Title/Summary/Keyword: heating load

Search Result 892, Processing Time 0.034 seconds

Study on Heating Load Characteristics and Thermal Curtain Effects for Simple Silkworm Rearing Houses(II) -Effects of the Thermal Curtain on Energy Preservation and Review of its Application- (간역잠실(簡易蠶室)의 난방부하특성(暖房負荷特性) 및 보온(保溫)커튼 설치(設置)효과에 관한 연구(硏究)(II) -보온(保溫)커튼의 열(熱) 절감(節減) 효과(効果) 및 적응성(適應性) 검토(檢討)-)

  • Choe, K.J.;Jung, D.H.;Park, K.K.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.1
    • /
    • pp.83-89
    • /
    • 1991
  • One of the most serious problems in Korean sericulture farms is to improve the adiabatic conditions for the simple silkworm rearing houses which has been widely adapted since early 1980'. Thus, this study is aimed to solve the problems by selecting the thermal screen material and by finding the method of its instalation. For the study, 4 kinds of materials which are (1) TE005,(2) NW60, (3) NW300 and (4) AL110 are selected and 4 different types of methods which are surrounding boundary of rearing bed(type A), surrounding inside of wall and ceiling (type B), installing on inside of wal ony (type C) and installing on ceiling Inly (type D) are installed. Decision criteria of the best combination of screen material and installation methods is made by calculating the heating load coefficients and by testing the application at the simple silkworm rearing houses. The obtained results are summarized as follows ; 1. The effect of thermal screen on reducing the thermal energy is remarkable. It saves energy more 50% than unscreened simple silkworm rearing houses. 2. From a stand point of a good screed material on thermal energy reduction, the NW300, AL110 and PE005 are recommanded materials. However, NW60 and PE005 are regarded as desirable materials from the practical point view. 3. Also, the effect on thermal energy reduction is largely affected by the method of thermal screen installation. The surrounding boundary of the silkworm rearing bed(type A) is the most desirable method to reduce the energy, which saves 56.6% of it. 4. In the practical application, NW60 and type A is considered to be the best combination of material and installation method. By this combination, the level of maximum heating load can be reduced at the rate of 43% for spring season and 40% for autumn season. 5. Another heating method, comparted heating, can be recommended to save the energy.

  • PDF

Analysis and Comparison of Standard and Existed Heating Degree-Hours Model for decision of Greenhouse Heating Load in Korea (온실의 난방부하 결정을 위한 Degree-Hour 모델식 비교 분석)

  • Woo, Young-Hoe
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.6 no.1
    • /
    • pp.143-154
    • /
    • 2004
  • The value of daily heating degree hour(described as DH hereafter) is essential for calculating the heating load of a greenhouse during the winter months. Many researchers have so for proposed different models for estimating DH value. Models for estimating DH have been investigated DH(unit, ℃·h·year-1) in this paper. The comparisons of standard and existed DH values were made to know the estimation error of each model proposed so far. The standard DH values and other proposed DH values have were obtained for the inside setpoint temperatures of 9, 13, 16 and 20℃ in greenhouse, estimated based on meterological data from 1961 to 2000 according to locals, and standard DH values were independent and existed DH values were dependent. Among the various model, the one developed theoretically by Mihara modified to author was the best fitting for standard DH values. The DH values were obtained for the inside setpoint temperature of 9, 13, 16 and 20℃ by Modified Mihara's model. A new DH contour line graph was proposed using Modified Mihara's model. Using the DH contour line graph, the DH values can be obtained easily for any setpoint according to local.

Novel Electromagnetic Induction Eddy Current DPH based Continuous Pipeline Fluid Heating using Soft Switching PWM High Frequency Inverter

  • Nam, Jing-Rak
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.3
    • /
    • pp.305-309
    • /
    • 2008
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction eddy current based fluid heating appliance using voltage-fed quasi resonant zero voltage soft switching PWM high-frequency inverter using IGBTs, which can operate at a constant frequency variable power regulation scheme. The promising simple high efficient low noise inverter type electromagnetic induction eddy current based pipeline fluid heating appliance is proposed for saturated steam generator, superheated steam generator, hot water and hot air producer, metal catalyst heating for exhaust gas cleaning in engine. Under these technological backgrounds, a novel electromagnetic induction eddy current Dual Packs Heater(DPH) based pipeline fluid heating incorporates thin metal layer type package for continuous fluid heating appliances applying two types of voltage-fed quasi load resonant ZVS-PWM high frequency inverter. The unique features of a novel electromagnetic induction eddy current DPH based continuous pipeline fluid heating appliance is illustrated on the basis of simulation and discussed for the steady state operating characteristics and experimental results.

Study on the Operating Characteristics with Load Condition in Hybrid Solar Heating System during Spring Season (봄철 태양열 하이브리드 시스템의 부하조건 변화에 따른 운전특성 연구)

  • Pyo, Jong-Hyun;Kim, Won-Seok;Cho, Hong-Hyun;Ryu, Nam-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1418-1423
    • /
    • 2009
  • This study describes experimental study on the performance characteristics with load condition in hybrid solar heating system during spring season. The room temperatures, the hot water conditions and the lower part temperatures of heat storage tank were changed to analyze the system performances. As a results, the hot water was significantly affected by the ambient temperature. The indoor setting temperature affected the solar fraction. When the low part temperature of the storage tank increased, the temperature of the hot water rose and the temperature of the hot water in morning was affected by the ambient temperature.

  • PDF

Study on the Parallel Resonant Inverter of an High Frequency Induction Heating System which the Frequency Tracking and the Power Regulation is possible (주파수 추종과 정전력 제어가 가능한 고주파 유도가열기의 병렬 공진형 인버터에 대한 연구)

  • 김남수;김태언;김승철;임영도
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.63-66
    • /
    • 2002
  • This paper has been studied the parallel resonant inverter which controlling the constant power and tracking the load resonant frequency with PLL is possible, in order to minimize switching losses. The current-fed full-bridge type parallel resonant inverter of an induction heating system was composed of IGBT in switching device. For regulating the output power of an induction heating system, the Fuzzy controller is used. The Fuzzy controller makes the control signal for a stable power regulating control and when reference is changed, it is superior to adaptability. It has been evaluated a stable behavior for a noise with switching and a load disturbance.

  • PDF

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • Pak, Ee-Tong;Jeong, Un-Chul
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.39-47
    • /
    • 1996
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. And arrangement of heating pad play an important role in thermal flow and thermal storage efficiency. In this experiments, number of heating pad is ranged from three, five and nine, and when there is no change on number of heating pad, arrangements are two types of concentration-type and dispersion-type. Strong entrainment take place in the case of concentration-type of heating pad, and rapid temperature rise(${\Delta}{\doteqdot}1.6{\sim}3.2^{\circ}C$) in the tank is obtainable on the concentration-type than dispersion-type. In the constant number of heating pad, the concentration-type has the higher efficiency with about $5{\sim}6%$ than the dispersion-type Therefore, concentration-type of heating pad is an efficient design in constant number of heating pad.

  • PDF

Building Energy Load Estimation by a Statistical Method (통계적 방법에 의한 건물 부하 산정)

  • Chung, Mo;Park, Hwa-Chun;Im, Yong-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.342-347
    • /
    • 2008
  • A Microsoft $Access^{(R)}$ application that estimates hourly building energy load is developed based on statistical field measurements. Hourly patterns of heating, hot water, cooling, and electricity loads are evaluated for an energy consuming community composed of various types of buildings. Popular building types such as apartments, offices, hotels and accomodations, stores, churches, schools and educational institutes are included in the model. For each type of buildings, hourly patterns for a month are measured and compiled to derive a 24-hour load distributions. Daily sum of heating, hot water, cooling, and electricity loads are also measured for the building types. The annual energy need profiles are generated by combining the 24-hour distribution and 365-day consumption patterns. The annual maximum values of the 8760 hours of a year for each load type serves as a guide for selecting a device capacity. A user-friendly interface that ushers users throughout the whole process is provided.

  • PDF

A Study on the Comparison of the Vibration Data in Cast Resin Transformer According to the Load Type (부하 형태에 따른 몰드변압기에서의 진동데이터 비교에 관한 연구)

  • Shong, Kil-Mok;Choi, Myung-Il;Kim, Young-Seog;Bang, Sun-Bae;Kim, Chong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.75-81
    • /
    • 2012
  • In this study, vibration characteristics in according to the load type of cast resin transformer using vibration measurement device were compared. Measurement conditions are the same installation and operation of the three-phase cast resin transformer. If the load increases in transformer using the rotating machinery, the frequency is growing. In the transformer using the lighting and heating loads, it's detected the 55 [${\mu}m/s$] in or outside and 120 [${\mu}m/s$] or more at 60[Hz], the 30 [${\mu}m/s$] in or outside at 120[Hz], and the 70 [${\mu}m/s$] in or outside at 420[Hz]. When increases the loads, it's appeared the 60 [${\mu}m/s$] or less at 450[Hz] or more in rotating machinery, but the velocity of lighting and lighting loads are appeared from 5[${\mu}m/s$] to 115[${\mu}m/s$] inside the 420[Hz] in the same load condition of 20[%]. Through this study, it's verified that there are differences the internal vibration in according to the type of load in cast resin transformer.

Effect of Additional Early-Morning Heating Periods on the Growth and Yield of Cucumber and Heating Load (조조가온기간이 시설재배 오이의 생육과 수량 및 난방부하에 미치는 영향)

  • Kwon Joon Kook;Kang Nam Jun;Lee Jae Han;Kang Kyung Hee;Choi Young Hah
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.245-250
    • /
    • 2004
  • To investigate the effect of early-morning heating periods on growth and yield of cucumber and heating load in a greenhouse cultivation, three additional heating periods (0, 1 and 2 hours) were compared to rise temperature from $12^{\circ}C\;to\;16^{\circ}C$ in the early-morning. Leaf temperature just before opening the thermal screen was $3.3^{\circ}C\;and\;4.1^{\circ}C$ higher in the 1 and 2 hour heating compared to that in the control (0 hour heating), respectively. Photosynthetic rate, conductance to $H_2O$ and transpiration rate of cucumber leaves were the highest in the 2 hour heating, and the lowest in the control. However. the difference between the 1 hour and 2 hour heating was not significant. Inorganic element content in cucumber leaves was not significant among the treatments of duration. Initial growth after planting of cucumber was greater in the 1 and 2 hour heating than that in the control. Yield increased by $11\%\;and\;15\%$ in the 1 hour and 2 hour heating compared to that in the control. respectively. Fuel consumption for heating increased by $12\%\;and\;22\%$ in the 1 hour and 2 hour heating compared to that in the control, respectively. Considering in the yield and fuel consumption for heating. 1 or 2 hours of early morning heating could be effective in temperature management for cucumber in a greenhouse cultivation.

Heat Consumption Pattern Analysis by the Component Ratio of District Heating Users (지역난방 사용자 구성비에 따른 열소비 패턴 분석)

  • Lee, Hoon;Lee, Min-Kyun;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.211-225
    • /
    • 2013
  • To run an optimal operation of Integrated energy supply facilities, we need to analyze heat consumption patterns of District heating users and derive optimum and maximum load ratio of heat production facilities unit. This study selects three District heat production facilities. It also classifies District heating users into residential apartment buildings and eight non-residential buildings and analyzes heat consumption results for an year. Finally it carries out the analysis of how the ratio change of each type affects maximum load ratio, facility utilization ratio, heat supply range. According to this study, three different District heat facilities of residential apartment building show similar daily and annual heat consumption patterns. Annual average load ratio, maximum load ratio and annual heat demand increase as outdoor temperatures decrease. Non-residential buildings in urban District focused on apartment buildings display similar by the daily and annual heat consumption patterns. Yet their daily and annual maximum load ratio differ according to outdoor temperature, District, building types and their composition ratio. In the case of urban District focused on apartment buildings reach optimum and maximum load ratio when apartment buildings reaches 60-70% of the total. At that point heat supply range becomes maximized and the most economic efficiency is obtained.