• Title/Summary/Keyword: heated water discharge

Search Result 32, Processing Time 0.019 seconds

Effects of Heated Effluents on the Intertidal Macroalgal Community near Uljin, the East Coast of Korea (동해안 울진원전의 온배수 방출이 주변 해조군집에 미치는 영향)

  • Kim, Young-Hwan;Ahn, Jung-Kwan;Lee, Jae-Il;Eum, Hee-Moon
    • ALGAE
    • /
    • v.19 no.3
    • /
    • pp.257-270
    • /
    • 2004
  • In order to clarify the structure and seasonal dynamics of warm tolerant benthic marine algal community in Korea, the species composition and biomass of marine algae at the discharge canal of Uljin nuclear power plant on the East Coast of Korea were investigated seasonally from February 1992 to October 2000. 107 species of marine algae were found at the discharge canal during the past nine years. In general, the number of species observed was abundant in spring or summer and less in autumn or winter. 27 species (4 blue-green, 5 green, 6 brown and 12 red algae) of marine algae occurred more than 1/ 6 frequency and thus can be categorized as warm tolerant species. Among these, one brown (Dictyota dichotoma) and four red algae (Gelidium amansii, Anphiroa ephedraea, Hydrolithon sargassi, Marginisporum crassissimum) are recorded as warm tolerant marine algae for the first time in Korea. Padina arborescens, Anphiroa zonata and Corallina pilulifera were common species found more than 75% frequency. Seasonal fluctuations of mean biomass were 0-1,330 g dry wt m^(-2) and dominant species in biomass were Corallina pilulifera (contribution to a total biomass proportion 34%), Anphiroa zonata (23%), Padina arborescens (18%) and Sargassum micracanthum (11%). The red algae appeared as predominant algal group at the discharge canal of Uljin nuclear power plant in the qualitative and quantitative aspects. The green algae such as Enterornorpha compressa appeared rather frequently at the discharge canal, but the biomass proportion was very low, in contrast to Kori nuclear power plant where there was definite green algal dominance. Differences in algal communities developed at the discharge canals of Uljin and Kori nuclear power plant on the East Coast of Korea, particularly biomass proportions of green algae, can probably be related to local environmental factors such as water velocity through the canal and natural seawater temperatures.

Effect of Injection Pressure on the Flash Boiling Spray from Simple Orifice Nozzle (인젝터 압력이 단공노즐 감압비등 분무에 미치는 영향)

  • Lee, Hyunchang;Cha, Hyunwoo;Kang, Donghyeon
    • Journal of ILASS-Korea
    • /
    • v.27 no.1
    • /
    • pp.42-49
    • /
    • 2022
  • Flash boiling occurs in a couple of modern engineering systems and understanding its mechanism is important. In this experimental study, discharge coefficient of flash boiling spray from simple orifice nozzle was measured, and backlight imaging was acquired at injection pressure to 6.0 bar and temperature to 163℃ for the purpose. Pressurized water by pump was used for working fluid and was heated by electric heater and ejected through simple orifice nozzle diameter of 0.5 mm. High speed camera with long distance microscope was used for backlight imaging in two FoV having magnification of 3.3 and 0.64. The decrease of discharge coefficient according to degree of superheating and evolution of flash boiling spray imaged at various pressure and temperature were explained by the pressure field inside the injector.

Response Time Index and Suppression Capability of Standard and Quick Response Sprinkler Head (표준형 및 속동형 스프링클러헤드의 반응시간지수와 소화성능)

  • 정길순;이병곤
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.59-70
    • /
    • 1998
  • In this study, response time index(RTI) of standard and quick response type sprinkler head are measured and compared through ramp and plunge test in heated wind tunnel. Also discharge rate and water distribution, actual delivered density(ADD), fire test with wood cribs are performed to compare the fire suppression capability and the operation time and temperature between standard and quick response type sprinkler head.

  • PDF

A Comparative Study of Two-Dimensional Numerical Models for Surface Discharge of Heated Water into Crossflow Field (가로흐름 수역으로 방출되는 2차원 표면온배수 수치모형 비교연구)

  • 이남주;최흥식;이길성
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.6 no.1
    • /
    • pp.40-50
    • /
    • 1994
  • For an accurate prediction of the temperature field induced by heated water discharged into a shallow crossflow, a two-dimensional near-field numerical model is developed. It is based on a 4-equation turbulence model in which the transport equations for mean of the temperature fluctuation squared and its dissipation rate are added to those of a 2-equation turbulence model which cannot give the information of the thermal time scale ratio. Vertical diffusion is also considered by including buoyancy production and turbulence heat flux terms. The developed model is applied to a steady flow in an open channel with simple geometry and the results are compared with existing experimental data and those of the already established 2-equation turbulence model. Numerical results of the model agree with the experimental data better than those of the 2-equation model. The present model also simulates quite adequately the physical characteristics of thermal discharge in the jet entrainment and stable regions.

  • PDF

A Two-dimensional Turbulence Model for the Thermal Discharge into Crossflow Field (가로흐름 수성으로 방출되는 2차원 온배수 난류모형)

  • Choi, Hung-Sik;Jung, Kyung-Tae;So, Jae-Kwi;Lee, Kil-Seong
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.5 no.2
    • /
    • pp.91-98
    • /
    • 1993
  • A two-dimensional turbulence model for the surface discharge of heated water into cross-flow field has been developed. The depth-averaged continuity, momentum and temperature equations, are solved by an efficient finite-difference procedure known as SIMPLE. Turbulent stresses and heat fluxes are determined from a depth-averaged version of the $textsc{k}$-$\varepsilon$ equation. Results of test run clearly demonstrate its effectiveness in handling strong turbulent phenomena in very shallow near-field region.

  • PDF

A Three-Dimensional Turbulence Model far the Thermal Discharge into Cross-Flow Field (가로흐름 수역으로 방출되는 3차원 온배수 난류모형)

  • 이남주;최흥식;허재영
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.2
    • /
    • pp.148-155
    • /
    • 1995
  • For an accurate prediction of the temperature Held induced by surface discharge of heated water into an ambient cross-flow field. a three-dimensional near-field numerical model using k-$\varepsilon$ turbulence clousure is developed Rather restricted as it is, the numerical results of the model agree well with the experimental data. The developed model simulates quite adequately the stratification, gravitational lateral spreading, and upward entrainment of thermal jet which cannot be simulated by a depth-integrated two-dimensional numerical model, as well as the interaction with cross-flow.

  • PDF

Study on Current and Water Quality Characteristics in Yongil Bay (영일만내의 유동과 수질특성에 관한 연구)

  • 김헌덕;김종인;류청로
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.246-252
    • /
    • 2000
  • The water quality in Yeongil Bay is getting worse due to the sewage and the waste water from the surrounding industrial complex The study aims to simulate the current system that is necessary to built ecosystem model for the optium water quality control and clarify the correlation of current system characteristics with water quality in Yongil Bay. To clarify the characteristics of coastal water movement system and verify the applicability of the 3-D model, the current system was simulated using 3-D baroclinic model considered tidal current and density effects. As the results of numerical experiments, it is proved the 3-D model is the most appliable on the Yongil Bay where current flows slowly and the flow direction is varied by depths. From the results of simulation considered tidal current only, It am be clearly said the water in Yongil Bay flows in through the surface layer and flows out through the bottom layer. And the fresh water from the Hyongsan river and the heated discharge from POSCO have little effect on the current structure in Yonggil Bay, but have and important effect upon the density structure by diffusion of heat and salt. And the water quality distribution is closely related with the current structure characteristics as well as the tidal residual current system.

  • PDF

Extinguishment of Liquid Fuel Fire by Water Mist Containing Additives

  • Park, Jae-Man;Won, Jung-Il;Shin, Chang-Sub
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.24-29
    • /
    • 2005
  • An experimental study was presented for extinguishing characteristics of liquid fuel fire by water mist($Dv_{0.99}{\leq}200{\mu}m$) containing potassium acetate and sodium acetate trihydrate. To evaluate the extinguishing performance of water mist containing additives, the evaporation characteristics of a water droplet on a heated surface was examined. The evaporation process was recorded by a charge-coupled-device camera. Also, small-scale extinguishing tests were conducted for n-heptane pool fire in ventilated space. During the experiments, flame temperatures were measured, and concentrations of oxygen and carbon monoxide were analyzed by a combustion gas analyzer. The average evaporation rate of water droplet containing additives was lower than that of pure water at a given surface temperature and decreased with the concentration increase due to the precipitation of salt in the liquid-film and change of surface tension. In case of using additives, the fire extinguishing times was shorter than that of pure water at a given discharge pressure and it was because the momentum of a water droplet containing additives was increased. And also dissociated metal atoms, potassium or sodium, were reacted as a scavenger of the major radical species OH, H which were generated for combustion process. Moreover, at a high pressure of 4 MPa, the fire was extinguished through blowing effect as well as primary extinguishing mechanisms.

A Study for Developing the Thermal Dehydrator (고효율 열 탈수장치 개발에 관한 연구)

  • Lee, Jung-Eun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.2 s.23
    • /
    • pp.35-40
    • /
    • 2004
  • A generation rate of sludge in Korea had increased dramatically about $200\%$ for a decade. A requirement for high efficiency dewatering system being possible to produce the low water content cake have suggested due to the appearance of commercial and social problems about handling of dewatered cake. The conventional dewatering system with mechanical compression device was not suitable to produce the low water content cake and didn't cope with lots of requirements. Therefore, this paper was to develop the high efficient filter press with the compressive and heating forces through the heating plate to be built between membrane fillet plates. It is possible to produce the low water content cake and improve the dewatering rate, so this equipment positively coped with several types of problems related to the sludge dewatering. The plate heated by heat transfer materials such as steam, hot water and thermo-oil made the sludge make the residual moisture within the cake to discharge easily and to improve the dewatering efficiency of equipment. The pilot scale experiment with 500kg of cake production showed that the dewatering efficiency determined by the final water content and dewatering velocity was improved $30\%$ more than the conventional dewatering equipment.

A Study for Developing the Thermal Dehydrator (고효율 열 탈수장치 개발에 관한 연구)

  • Lee, Jung-Eun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.278-283
    • /
    • 2003
  • A generation rate of sludge in Korea had increased dramatically about 200 % for a decade. A requirement for high efficiency dewatering system being possible to produce the low water content cake have suggested due to the appearanceof commercial and social problems about handling of dewatered cake. The conventional dewatering system with mechanical compression device was not suitable to produce the low water content cake and didn'tcope with lots of requirements. Therefore, this paper was to develop the high efficient filter press with the compressive and heating forces through the heating plate to be built between membrane filter plates. It is possible to produce the low water content cake and improve the dewatering rate, so this equipment positively coped with several types of problems related to the sludge dewatering. The plate heated by heat transfer materials such as steam, hot water and thermo-oil made the sludge make the residual moisture within the cake to discharge easilyand to improve the dewatering efficiency of equipment. The pilot scale experiment with 500kg of cake production showed that the dewatering efficiency determined by the final water content and dewatering velocity was improved 30% more than the conventional dewatering equipment.

  • PDF