• Title/Summary/Keyword: heat storage rate

Search Result 321, Processing Time 0.025 seconds

Simulation of Open-Loop Borehole Heat Exchanger System using Sand Tank Experiment and Numerical Model (토조 및 수치모형을 이용한 개방형 지중 열교환 시스템 모의)

  • Lee, Seong-Sun;Bae, Gwang-Ok;Lee, Kang-Kun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.489-492
    • /
    • 2007
  • Understanding the thermohydraulic processes in the aquifer is necessary for a proper design of the aquifer thermal energy utilization system under given conditions. Experimental and numerical test were accomplished to evaluate the relationship between the geothermal heat exchanger operation and hydrogeological conditions in the open-loop geothermal system. Sand tank experiments were designed to investigate the open-loop geothermal system. Water injection and extract ion system as open-loop borehole heat exchanger was applied to observe the temperature changes in time at injection well, extraction well and ambient groundwater. The thermohydraulic transfer for heat storage was simulated using FEFLOW for two cases of extraction and injection phase operation in sand tank model. As one case, the movement of the thermal plume was simulated with variable locations of injection and extraction well. As another case, the simulation was performed with fixed location of injection and extraction well. The simulation and experimental results showed that the temperature distribution depends highly on the injected water temperature and the length of injection time and the groundwater flow and pumping rate sensitively affect the heat transfer.

  • PDF

Flow Analysis and an Experimental Study on Formation of Slurry Ice in the Reversing Flow Layer (역전 유동층 내의 유동해석 및 슬러리아이스 생성에 관한 연구)

  • Oh, Cheol;Choi, Young-Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.421-428
    • /
    • 2011
  • Thermal energy storage(TES) cooling system using cheaper electricity of off-peak time has been applied to relieve a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type thermal energy storage cooling system is one kind of more efficient ice-thermal energy storage cooling system than Ice-on-Coil type or Encapsulated type TES cooling system, even though, which are more popular TES system. This experimental study was carried out to observe flow pattern and formation of slurry ice in reversing flow layer to improve efficiency of heat transfer between fluid and freezing tube and to disturb ice adhesion on tube surface. The reversing flow layer was made by using reversing materials in heat exchanger section(test section) to disturb ice adhesion. At this experiment, styrofoam balls and poly propylene balls were used as reversing materials, and a 20wt% solution of ethylene glycol was used as reversing flow layer. The experimental apparatus was constructed of the test section for making/storing slurry ice, the brine tank, pumps for circulating of a 20wt% solution of ethylene glycol and brine, a flow-meter, a data logger for measuring the temperature. The experiments were carried out under various conditions, with volumetric flow rate, ball filling rate and air filling rate.

The Characteristics of the Dehydration Reaction and the Durability for the Thermal Decomposition in Na2B4O7·10H2O/Na2B4O7·5H2O System (Na2B4O7·10H2O/Na2B4O7·5H2O 계의 열분해 탈수반응 및 내구성 고찰)

  • Choi, Ho-Sang;Park, Young-Tae
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.885-888
    • /
    • 1999
  • This study was carried out to determine the reaction kinetic constant of the dehydration - thermal decomposition of $Na_2B_4O_7{\cdot}10H_2O/Na_2B_4O_7{\cdot}5H_2O$ and to investigate the durability during the repeated use of a chemical heat-storage material and the reproducibility of reaction system. The order of the dehydration reaction was 1st-order. The reaction rate was directly proportional to a partial pressure difference of water steam. The kinetic constant was 0.27 and the reproducibility of dehydration reaction for a kinetic constant and a reaction order was excellent. The activity variation in the durability test of a chemical heat-storage material was within range of ${\pm}5%$ during the repeatedly use in several times.

  • PDF

Performance of a Latent Heat Storage System Using Two-Phase Closed Thermosyphon(II) - The Case of Constant Temperature Heating Fluid (열싸이폰을 이용한 잠열축열시스템의 성능실험(II) - 일정한 온도의 가열유체를 사용한 경우 -)

  • Kim, Tae-Il;Kim, Ki-Hyun
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.37-46
    • /
    • 1992
  • An experimental study was carried out to investigate the performance of a latent heat storage system using paraffin wax as the phase change material. A thermosyphon was employed to transfer heat from the hot ethylene glycol flowing across the evaporator section of the thermosyphon into the wax. In order to increase the effective thermal conductivity of wax, layers of copper wire mesh were immersed in the wax. Experiments were run for volume ratios of 2%, 3%, and 4%, varying mass flow rate of ethylene glycol in each case. Some of the important results are as follows : (1) The wire mesh enhanced the conductive hea transfer and thus, helped even out the temperature distribution in the wax : (2) The increase of the number of layers of wire mesh increased the conduction. However, it also resulted in increasing the resistance to the convective motion of liquefied wax : and (3) There is an optimal number of layers of wire mesh, maximizing the performance of the storage system, which occurred at a volume ratio of $3{\sim}4%$ in the present study.

  • PDF

Pigment Stability of Lavers Porhyra tenera Kjellman during Processing and Storage (김의 가공 저장중에 있어서의 색소의 안정도)

  • LEE Kang-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.2 no.2
    • /
    • pp.105-133
    • /
    • 1969
  • The stability of three major pigments in lavers, namely chlorophylls, carotenoids, and phy-cobilins, during processing and storage was studied. The results of the pigment retention in fresh lavers during storage at low temperatures, of heat lability during heat treatment, and of the pigment loss during storage are summarized as follows: 1. The contents of chlorophyll a, xanthophyll (lutein+zeaxanthin), and carotene ($\alpha-+\beta-carotene$) averaged 1,525, 627, and $409{\mu}g/g$ of dry samples respectively The comparative composition of four carotenoids, lutein, $\beta-carotene$, zeaxanthin, and $\alpha-carotene$, was 35.9, 33.7, 12.2, and $5.8\%$ respectively. 2. In storage of fresh lavers at room ternperature ($20-25^{\circ}C$), 2 to $5^{\circ}C$, and $-15^{\circ}C$, the pigments generally were retained more at 2 to $5^{\circ}C$ than others while carotene only showed more retention at $-15^{\circ}C$ than at 2 to $5^{\circ}C$. Phycocyanin tended to decrease more rapidly than phyco-erythrin at low temperatures. 3. In regard to heat treatment of both dried and wet materials at 40, 60, 80, $100^{\circ}C$ respectively, the pigments were more stable at lower temperatures than at higher temperatures in both cases of materials. Carotenoids were retained more in wet materials than in the sun dried. Xanthophylls showed higher heat stability than carotenes. Phycoerythrin was considered more heat labile than phycocyanin, particularly at higher temperatures. 4. In storage of heat treated lavers for 50 days at room temperature, the retention of pigments appeared differently in accordance with the temperatures of treatment The materials treated at $60^{\circ}C$ showed better relention of pigments than those treated at the other temperatures. Degradation rate of xanthopllylls, carotenes, and phycobilins was decreased in the materials treated at higher temperatures, showing a tendency of great pigment retention even for a long period storage. Chlorophyll il was retained more in sun dried materials whereas xanthophyll and carotene were retained more in the wet. 5. In order to maintain a higher pigment stability during storage, the materials must be treated at $60^{\circ}C$ in a dryer with rapid ventilation until the moisture level reaches about $6.0\%$. In case of treatment at a higher temperature than $60^{\circ}C$, they must be treated for a short period of time to minimize pigment degradation by heat. 6. The lavers treated with the solutions of pH around 7.8 showed a higher retention of chlorophyll a. When treated with the solutions of algal extracts such as agar and alginic acid, uniform layer of laver sheets and better surface gloss of dried layers were obtained.

  • PDF

Analysis on the Heat-Resisting Property of Metal Conversion Furnace in the Hot-Cell (핫셀에서 금속전환로의 내열 특성 분석)

  • 김영환;윤지섭;정재후;홍동희;박기용;진재현
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.303-306
    • /
    • 2003
  • To reduce the storage space of spent fuels used at the atomic power plants all over the world, the uranium elements contained in the spent fuels is being extracted and effectively stored. For this, the spent fuel are oxidized and deoxidized. In this study, it is produced conceptual design specification about the spent fuel management technology research and test facilities have been produced. The first considered processes in the facilities is the metal conversion furnace in the dry environment. Since this process is operates at the high temperature range, we have to consider heat-resisting designs for the device. For the heat-resisting designs, we have surveyed and analyzed technical references for material properties. Also, we have determined the temperature distribution condition of the device based on experimental results. We have calculated thermal stress and strain of each devices by the commercial analysis software, I-DEAS. By using the results, we have analyzed design configurations of the point at issue by thermal effects, and suggested alternative design configurations. It is experimented for inspecting confidence rate of heat strain. Based on these results, necessary design specifications for heat-resisting design have been produced.

  • PDF

DEVELOPMENT OF CFD PROGRAM FOR THE CONJUGATE HEAT TRANSFER ANALYSIS OF PMSM ELECTRIC MOTOR (PMSM 전동기 모터의 복합 열전달 해석을 위한 CFD 프로그램 개발)

  • Lee, Jung-Hee;Choi, Jong-Rak;Hur, Nahm-Keon;Kim, Joo-Han;Kim, Young-Kyoun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.488-493
    • /
    • 2011
  • The object of this study is to develope the program for analyzing the fluid flow and heat transfer of PMSM electric motor. The program will be mainly used for inexperienced users of CFD analysis. So it has to be performed using the geometry data and the heat source of each part only. Interface program for converting the given data to the instruction of pre-processor is developed. The conjugate heat transfer between a flow passage of the motor and inner parts consisting of rotor and stator is regarded. In order to reduce the computational time and memory storage, cyclic boundary condition is applied. For the numerical simulation, MRF(Multi-Reference Frame) method is used to consider rotating operation of the rotor and heat source is applied to the copper, wire, and magnetic parts in the motor. On the screen of computer, the users can show the velocity distributions and the contours such as pressure, turbulent kinetic energy, turbulent dissipation rate and temperature.

  • PDF

Dynamic simulation of a solar absorption cooling system (태양열을 이용한 흡수식 냉방기의 동특성 시뮬레이션)

  • 정시영;조광운
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.784-794
    • /
    • 1998
  • The present study has been directed at developing thermal models to investigate the dynamic behavior of a solar cooling system including an absorption chiller, solar collectors, a hot water storage tank, a fan coil unit, and the air-conditioned space. The operation of the system was simulated for 8 hours in two different operation modes. In the mode 1, the system operated without any capacity control.0 the mode 2, an auxiliary boiler supplied heat to the generator if hot water temperature became lower than a certain value. Moreover, the mass flow rate of hot water to the generator was controlled by comparing the instantaneous room air temperature with the design value. The variation of temperature and concentration in the system components and that of heat transfer rates in the system were obtained for both modes of operation. It was found that the room temperature was maintained near the desired value in the mode 2 by supplying auxiliary heat or controlling the mass flow rate of hot water, while the deviation of room temperature was quite great in the mode 2.

  • PDF

Quality Stability of a Softened, Sea Tangle Paste by Various Hydrocolloids during Storage (Hydrocolloid를 첨가한 연화 다시마 Paste의 품질 안정성)

  • Song Jae-Chul;Park Hyun-Jeong
    • The Korean Journal of Food And Nutrition
    • /
    • v.17 no.3
    • /
    • pp.246-253
    • /
    • 2004
  • This study was carried out to examine softening stability, exponent of Avrami equation, color change, sensory characteristcs during storage when hydrocolloid was added to the sea tangle paste treated with acetic acid and heat treatment. Rate constant of solidification showed the least value of 0.05 in Avrami equation. In addition hardness of the softened sea tangle paste was not changed after two days of storage in case of carrageenan. Rate of hardness in the softened sea tangle paste formulated with carrageenan exhibited the lowest value of 0.28 kg/mm/day. Heat melting spreadability of the softened sea tangle paste showed the highest value in case of carrageenan and its fluid behavior was rheopectic. Viscosity change in the sea tangle paste formulated with carrageenan was the least during storage and its significant difference at the level of p < 0.05 was exhibited. Change of L, a and b value of softened sea tangle formulated with carrageenan during storage was significantly different at level of p<0.05. Color preference, odor, cohesiveness, softerness, process compatibility and overall acceptance of softened sea tangle were revealed to be in best when carrageenan was added. When hydrocolloid was added to the softened sea tangle paste, it showed the positive result in quality and storage stability of softened sea tangle paste. It was extremely effective on softening stability when carrageenan was added to the softened sea tangle paste.

Field Test of Energy Storage System on Urban Transit System (도시철도용 에너지저장시스템 에너지 절감을 현장시험)

  • Lee, Han-Min;Kim, Gil-Dong;An, Cheon-Heon;Kim, Young-Gyu;Kim, Tae-Seok
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1461-1467
    • /
    • 2009
  • The electric railway is a clean and energy saving system, because it requires relatively less energy than automobiles by transporting the same passengers or goods. Six thousands of vehicles are operated on Korean urban transit system. This system is 95% of regeneration system. Especially, the VVVF-Inverter vehicle has a merit of the highest regeneration rate. Energy consumption is 90% for traction and 10% for auxiliary supply. Braking energy is about 40% of energy consumption. Up to 40% of the tractive power of vehicles capable of returning energy to the power supply can be regenerated during braking and that this energy can be used to feed vehicles which are accelerating at the same time. The energy generated by braking vehicle would simply be converted into waste heat by its braking resistors if no other vehicle is accelerating at exactly the same time. Such synchronized braking and accelerating can not be coordinated, the ESS(energy storage system) stores the energy generated during braking and discharges it again when a vehicle accelerates. This paper presents field tests about the energy saving rate of the developed ESS. when the ESS is on/off, energy saving rate of the ESS is tested. The verification test in the field focused on energy saving.

  • PDF