• Title/Summary/Keyword: heat storage

Search Result 1,519, Processing Time 0.111 seconds

Study on the Change of Lipid Peroxides Amount While Beef Bulgogi Cocking (우육(牛肉)의 불고기 조리시 과산화지질의 변화에 관한 연구)

  • Shin, Duk-Kue
    • Journal of the Korean Applied Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.75-87
    • /
    • 1989
  • Study to report this result that state of lipid peroxides while beef Bulgogi Coocking of general-seasoning, sale-seasoning, each flavour's characteries. Raw meat show high lipid peroxides amount and high increasing in heat and antioxidative effected by flavour about lipid peroxidies change existence by beef Bulgogi seasoning. Change of lipid peroxides are significant increased in meat cold storage and cold storage and cold storage heat meat after while 30 minute after seasoned and reduced 9 hour - 33 hour cold storage raw meat, that change of lipid peroxides by cooking time. every condition by adding soften were revealed lipid peroxides, reduce. Lipid peroxide change are very high while no-sugar in raw meat and not a stone look in 9-hour raw-meat after seasone about antioxidative effect by each flavour characteristic TBA showed very high not take parched seasone seeds item about 30-minute cold storage beat raw-meat and high lipid peroxides revealed increase in not take wine item, not take a pear item, in 9 hour cold storage heat-meal and it showed little amount not-sugar item, no opepper item. According to high lipid peroxides change reduced high after seasoned cold storage stage in Korea traditional Bulgogi Cooking and thought high that action of antioxidative lipid peroxides wine and a pear in flavour.

Experimental Verification for a Spiral-Jacketed Storage Tank Applied to Solar Thermal System (태양열 시스템에 적용된 나선재킷형 축열조의 실증실험)

  • Kim Jin Hong;Choi Bong Su;Hong Hiki;Kim Yong-Shik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.341-346
    • /
    • 2005
  • The simplification of solar thermal systems reduces the possibility of operating trouble and lowers the cost of the initial investment and maintenance. This also leads to increased competitiveness in the energy market. We proposed a spiral-jacketed storage tank that functions both as a heat exchanger and expansion tank, which removes the secondary piping and markedly simplifies the entire system. The new storage tank was designed and manufactured to maintain the same performance as the conventional system and the exiting system was remodelled by adopting the newly proposed storage tank. This experiment was conducted under real conditions over a period of several months. The retrofitted system with the spiral-jacketed storage tank showed good performance that is on a similar level as the previous system having a typical storage tank and heat exchanger.

An Analysis of the Optimal Thermal Storage Time of Air-Conditioning System with Slab Thermal Storage : An Analysis by the Gradient Method Algorithm (슬래브축열의 최적축열시간 산정 : 구배법 알고리즘에 의한 해석)

  • Jung, Jae-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.702-709
    • /
    • 2008
  • In this paper, the optimal thermal storage time of an air-conditioning system with slab thermal storage in office building was analyzed on the basis of the gradient method algorithm. The sum of room temperature deviation and heat extraction rate was set to the criterion function. It was calculated that four hours is the optimal thermal storage time under the standard evaluation criterion. Furthermore, some case studies were executed by controlling ratio of weight functions of room temperature deviation and heat extraction rate in criterion function. It is possible to design many kinds of optimal operation of an air-conditioning system with slab thermal storage by controlling ratio of the weight functions in criterion function.

A Study on the Heat Storage Utilizing Phase Change of Salt Hydrates in Vertical Piped-Storage System (수직관형(垂直管形) 축열조(蓄熱槽)에서의 수화염류(水化塩類)의 상변화(相変化)를 이용(利用)한 열저장(熱貯藏)에 관(関) 연구(硏究))

  • Yon, Kwang Seok;Cha, Gyun Do
    • Journal of Biosystems Engineering
    • /
    • v.9 no.2
    • /
    • pp.74-80
    • /
    • 1984
  • Storage materials for a minimized storage system should be able to store much energy in small quantities, and to solve such a problem, salt hydrates such as CALCIUM CHLORIDE, SODIUM SULFATE, SODIUM PHOSPHATE etc. were considered as most suitable storage media in which phase change phenomena take place at low temperature. Therefore those salt hydrates were used as storage media in this study, and piped-storage tanks were manufactured vertically for the experiment. The characteristics of thermal storage media were investigated and the results are summarized as follows: 1. From the experiment of radial temperature distribution of vertical piped-storage system, the latent heat phenomenon did not occur in all storage media during heating process because of generations of heat due to the reduction in the number of water molecules. However, among those storage media CALCIUM CHLORIDE had most remarkable latent heat phenomenon during cooling process. Therefore CALCIUM CHLORIDE was considered as most suitable storage media. 2. Heat quantity transferred to the storage media was the largest in case of CALCIUM CHOLORIDE under the same conditions during heating and cooling process.

  • PDF

Heat Transfer Analysis of a Thermal Storage System using the Ice Capsule of Bar and Ring Module (봉과 링 조합형 아이스캡슐을 적용한 축열시스템의 열전달 해석)

  • Kim, Myoung-Su;Choi, Hyoung-Gwon;Byon, Sung-Kwang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.268-275
    • /
    • 2008
  • The shape and array of ice capsules are very important factors in ice thermal storage system because the heat transfer rate of the system strongly depends upon them. In this paper, a new type of ice capsule composed of bar and ring module is proposed to increase the efficiency of the ice thermal storage system. To investigate the heat transfer rate of the proposed ice capsule, numerical analysis of the incompressible Navier-Stokes equations is performed to compare the proposed bar and ring system with the conventional ice capsules. It is shown that the ice capsule composed of bar and ring has a higher heat transfer rate and a low outlet temperature than the conventional ice capsules for various packing ratios and entrance velocities. Furthermore, it is found that the optimal entrance velocity exists between 0.005 m/s and 0.007 m/s from the present numerical analysis.

A Study on Optimal Control of Slab Cooling Storage Considering Stochastic Properties of Internal Heat Generation (내부발열의 확률적 성상을 고려한 슬래브축냉의 최적제어)

  • Jung, Jae-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.6
    • /
    • pp.313-320
    • /
    • 2015
  • In this paper, a method to obtain the probability distribution of room temperature and cooling load is presented, when the internal heat generation is applied to the system as a disturbance in the air conditioning system with slab cooling storage. The probability distribution of room temperature and the cooling load due to the disturbance were examined in one room of an office building. When considering only the electric power consumption as a probability component, it was found that the effect on room temperature and cooling load is small, because the probability component of the measured electric power consumption in the building is small. On the other hand, when considering the stochastic fluctuations of electric power consumption together with the heat generated by human bodies, the mean value of the cooling load was about 2,300 W and the ratio of the standard deviations was 19% (10 o'clock in second day). It was revealed that the stochastic effects of internal heat generation acting on the air conditioning system with slab cooling storage are not small.

Dynamic performance analysis of flat plate solar collector system according to weather conditions and capacity of heat storage tank (기상조건과 축열조 용량에 따른 평판형 태양열 집열기 시스템의 동적 성능 해석)

  • Park, Bae-Duck;Kim, Gew-Deok;Kim, Kyoung-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.57-65
    • /
    • 2014
  • Solar energy has attracted wide attention as a promising renewable energy source. The goal of this paper is to estimate the dynamic performance of solar flat plate collector system according to the weather conditions and the capacity of heat storage tank. This study provides a detailed description of the modeling methods and materials of the system. The effects of the daily clearness index and the volume of the heat storage tank on the hourly and daily performances of the system are numerically investigated. Special attention is focused on the important system variables including the solar insolation on the collector surface, useful energy, heat loss at the collector, and collector efficiency.

Application analysis to a shared apartment house of heat storage type GSHP system with dual storage tank (이중 축열조를 갖는 축열식 지열원 히트펌프시스템의 노인공동주택 적용 분석연구)

  • Park, Jong-Woo;Lee, Sang-Hoon;Cho, Sung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.27-32
    • /
    • 2008
  • The present study has been conducted economic analysis of heat storage type ground source heat pump system(HSGSHP) and normal ground source heat pump (GSHP) which are installed at the same building in the shared an apartment house. Cost items, such as initial cost, annual energy cost and maintenance cost of each system are considered to analyze life cycle cost (LCC) and simple payback period (SPP) with initial cost different are compared. The initial cost is a rule to the Government basic unit cost of production. LCC applied present value method is used to assess economical profit of both of them. Variables used to LCC analysis are prices escalation rate and interest rate mean values of during latest 10 years. The LCC result shows that HSGSHP (1,050,910,000won) is more profitable than GSHP by 68.9% initial cost. And SPP appeared 3.0 year overcome the different initial cost by different annual energy cost.

  • PDF

Preparation and Thermal-property Analysis of Heat Storage Concrete with SSPCM for Energy Saving in Buildings (축열 성능 향상 SSPCM 혼합 콘크리트 제조 및 열적특성 분석)

  • Jeong, Su-Gwang;Chang, Seong Jin;Lim, Jae-Han;Kim, Hee-Sun;Ryu, Seong-Ryong;Kim, Sumin
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.89-96
    • /
    • 2015
  • n-octadecnae based shape stabilized phase change material (SSPCM) was prepared by using vacuum impregnation method. And an exfoliated graphite nanoplate (xGnP) which has high thermal conductivity properties is used as a PCM container. And then we made heat storage concretes which contains SSPCM for reducing heating and cooling load in buildings. In the prepararion process, the SSPCM was mixed to a concrete as 10, 20 and 30wt% of cement weight. The thermal properties and chemical properties of heat storage concrete were analyzed from Scanning electron microscope (SEM), Fourier transformation infrared spectrophotometer (FT-IR), Deferential scanning calorimeter (DSC), Thermogravimetric analysis (TGA) and TCi thermal conductivity analyzer. And we conducted surface temperature analysis of SSPCM and xGnP by using heat plate and insulation mold.

Effect of supercooling and cooling rate on a continuous ice slurry formation using a plate heat exchanger (판형 열교환기에서 유동 과냉도 및 냉각속도가 연속제빙에 미치는 영향)

  • Lee, Dong-Gyu;Peck, Jong-Hyun;Hong, Hi-Ki;Kang, Chae-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.138-143
    • /
    • 2006
  • The peculiarity of ice slurry, such as liquidity, high heat transfer rate and easy storage can also find to supercooled type dynamic ice storage system(DISS) which is one of the DISS. However, in order to accomplish continuous ice formation in the system without mechanical moving parts, supercooled aqueous solutionshould be formed stable through cooling heat exchanger and be dissoluted in storage tank. In previous research, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

  • PDF