• Title/Summary/Keyword: heat needle

Search Result 110, Processing Time 0.023 seconds

Effects of Sewing Conditions for Knitted Fabric on the Heat Generation of Sewing Needle (재봉바늘의 열발생에 미치는 편성물봉제조건의 영향)

  • 이춘규
    • Journal of the Korean Home Economics Association
    • /
    • v.24 no.3
    • /
    • pp.59-67
    • /
    • 1986
  • The heat of sewing needle is generated through the friction during the needle penetration into and withdrawal from fabrics. Therefore, effects of sewing condition for knitted fabric on the heat generation of needle was examined. The needle size was not the large influence factor of heat generation of needle but the needle point shape significantly affects needle temperature. And the super needle coated with fluoro resin had more effect on reducing the heat of needle. The decrease of sewing speed and the increase of stitch rate had more effect on the reduction in needle temperature. Also the Influence of a sewing thread on the needle temperature was very large compared with bare needle. As expected, an increase in the number of fabric layers result in higher needle temperature.

  • PDF

Experimental Interpretation of Heat Transmits Pattern on Warm Needling (온침의 열전달 특성에 대한 실험적 해석)

  • Yang, Seung-Bum;Park, Soon-Jae;Lee, Jae-Gun;Jung, Ji-Chul;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.34 no.3
    • /
    • pp.109-115
    • /
    • 2017
  • Objectives : Many researches have studied warm needling technique to standardize its treatment by temperature measurement and material differences in the effectiveness. The purpose of this study is to compare the temperature changes of the acupuncture needle shaft during the combustion process of the moxa stick to determine the heat transfer pattern of the warn needling. Methods : A moxa stick($7{\times}8mm$) was connected to one side of the needle shaft using a stainless steel needle(ø 0.3 mm, ø 0.5 mm, ø 0.8 mm, shaft length 40 mm) with the needle handle removed. During the warm needling, temperature changes of the needle shaft were observed with an infrared camera(Flir E30) and an infrared thermometer(TESTO 845). Results : In the normal condition, heat transmit of needle shaft increased at spots 10 mm and 25 mm below the moxa stick. The amount of heat transmit increased with the diameter of needle shaft. However, when the heat shield was installed to exclude radiant heat from the moxa stick, heat transfer was less at 10 mm below the moxa stick and no temperature change was observed at 25 mm below the moxa stick. Heat transfer by warm needling does not reach the end of needle shaft even in ø 0.8 mm needle. Conclusions : It is suggested that the radiant heat of moxa stick results in the heat transmit of acupuncture needle shaft. Thus, radiant heat transmit must be considered as one of the heat transfer characteristics of the warm needling.

Study of Air Flow Effects on Heat Characteristics of Warm Needle Acupuncture (온침 열특성의 기류 영향에 관한 연구)

  • Kim, Jung-Wo Roy;Lee, Hye-Jung;Yi, Seung-Ho
    • Korean Journal of Acupuncture
    • /
    • v.27 no.4
    • /
    • pp.35-47
    • /
    • 2010
  • Objectives : To characterize the thermal properties of traditional warm needle and new warm needle with various air flows as an important environmental factor and to suggest the necessity of maintaining suitable environment of clinics to maximize their efficacy. Methods : We measured the temperature characteristics of traditional moxa warm needle and new moxa charcoal warm needle by applying an automatic temperature acquisition system with thermocouples while external various air flows were supplied. Temperatures of two positions at the needle body were measured while a moxa cone burned. Typical temperature characteristics like peak temperature, duration, curve shape and the efficiency of the heat stimuli by heat amount analysis were executed. Results : Both warm needles showed similar temperature curve with an increase in the air flow. Peak temperature and duration of effective heat decreased with the air flow, as shown in indirect moxibustion on garlic. The temperature change pattern by the air flow became more apparent when the total combustion heat was compared with the effective heat. The values from two positions on the needle body were significantly different, showing a distance dependency from the heat source of warm needle acupuncture. Conclusions : Thermal properties of warm needle acupuncture was observed variously with surrounding air flow of 0.0 - 0.7 m/s. It emphasized the importance of environmental control as well as the warm needle itself such as heat source and needle. The latter has already been known to deliver designated heat to subjects. It also indicated the importance of education and skill of the practitioners of warm needle acupuncture.

Implementation of the Electric Cauterizer with the Hole for Acupuncture (유침 구멍이 구비된 전기뜸기의 구현)

  • Jo, Bongkwan;He, Yunsheng
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.18 no.3
    • /
    • pp.217-223
    • /
    • 2014
  • Objectives This study is on the implementation of the electric cauterizer with the hole for acupuncture to achieve the superposition effect of acupuncture-moxibustion therapies. Methods In this paper, we especially made a hole across the heat terminal of the electric cauterizer for acupuncture. Before the cauterization, the doctor treats a patient with needle. And after acupuncture, the heat terminal is to be superposed upon the needle along the hole to add the cauterization. Results There are 2 coupling methods that the heat terminal is to be superposed with the needle; one is the top-coupling and the other is side-coupling. The top-coupling means that the heat terminal is to be superposed upon the needle along the top of the needle, and side-coupling means that the heat terminal is to be superposed to the needle along the side of the needle. Conclusion This study was aimed to implement the electric cauterizer with the hole for acupuncture to achieve the superposition effect of acupuncture-moxibustion therapies. Not electric acupuncture but manual acupuncture is adopted. The electric cauterizer generates the heat $38{\sim}45^{\circ}C$. This heat is safe for skin not to burn. The electric cauterizer constitutes the smokeless moxa- pad which effects the skin DDS.

Coating of heat-acupuncture needle using an $Al_2O_3$ material to improve a heat insulation (한방침의 단열효과를 위한 $Al_2O_3$를 이용한 코팅연구)

  • Chung, Hyup-Jae;Rhee, Kyong-Yop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.114-119
    • /
    • 2009
  • In this research, heat-acupuncture needle was coated with $Al_2O_3$ by applying a plasma spray coating method to prevent a skin burn. $Al_2O_3$, which is one of the representative bioceramics, does not have an influence on the chemical change in the body system. The ceramic coating thickness was about $100{\mu}m$. The experiments of heat conduction were performed for uncoated needle and coated needle. The results showed that the surface temperature of needle decreased as the needle was coated with $Al_2O_3$. The surface temperature of uncoated needle was about $48^{\circ}C$, while that of needle coated with $Al_2O_3$ was about $39^{\circ}C$.

Study of the Thermal Properties of Warm Needle and the Development of Warm Needle Apparatus (온침의 열특성과 온침기기 개발에 관한 연구)

  • Kim, Jung-Wo;Lee, Hye-Jung;Ahn, Chang-Beohm;Yi, Seung-Ho
    • Journal of Acupuncture Research
    • /
    • v.28 no.1
    • /
    • pp.15-28
    • /
    • 2011
  • Objectives : To understand the strength and weakness of traditional warm needle acupuncture based on existing research outcomes in Korea mostly and to suggest how to build the desirable warm needle acupuncture apparatus by overcoming demerits of traditional and currently existing ones. Methods : We searched warm needle relating papers in Korean with the key words of '온침, 화침, 열자극' by using DBpia, Journal of Korean Oriental Medical Society, Journal of Korean Acupuncture & Moxibustion Society and Journal of Society for Meridian and Acupoint. Degree dissertations in Korean were also searched with the same words through the search engine of Library of Kyung Hee University. We also searched with words of 'warm, thermal, heat, needle, acupuncture, temperature' via Pubmed and found a small number of English written papers and large number of Chinese written ones. To find english translated version of those papers, we googled with the same words with no success. Results : About 20 papers on warm needle acupuncture written in Korean were found and analyzed with respect to experimental factors that affected the thermal properties or the amount of heat stimulus of the acupuncture. More rigorous descriptions seemed to be required on the insertion depth, duration and manipulation of warm needle treatment. A basic heat transfer model was presented for the clarification of heat loss through the needle of warm needle acupuncture. Environmental factors such as air flow on the properties seems to be considered for the warm needle acupuncture. Conclusions : Papers on warm needle acupuncture were reviewed and analyzed based on their thermal properties and tools such as needles and moxa cones. Several suggestions were made on the descriptions relating the properties. Necessary specifications were introduced to aim modernized warm needle systems.

Boundary layer analysis of persistent moving horizontal needle in Blasius and Sakiadis magnetohydrodynamic radiative nanofluid flows

  • Krishna, Penem Mohan;Sharma, Ram Prakash;Sandeep, Naramgari
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1654-1659
    • /
    • 2017
  • The boundary layer of a two-dimensional forced convective flow along a persistent moving horizontal needle in an electrically conducting magnetohydrodynamic dissipative nanofluid was numerically investigated. The energy equation was constructed with Joule heating, viscous dissipation, uneven heat source/sink, and thermal radiation effects. We analyzed the boundary layer behavior of a continuously moving needle in Blasius (moving fluid) and Sakiadis (quiescent fluid) flows. We considered Cu nanoparticles embedded in methanol. The reduced system of governing Partial differential equations (PDEs) was solved by employing the Runge-Kutta-based shooting process. Computational outcomes of the rate of heat transfer and friction factors were tabulated and discussed. Velocity and temperature descriptions were examined with the assistance of graphical illustrations. Increasing the needle size did not have a significant influence on the Blasius flow. The heat transfer rate in the Sakiadis flow was high compared with that in the Blasius flow.

Study on the Heat Transfer Characteristics of Warm Needle Materials in Korean Medicine (온침소재의 열전달특성에 관한 연구)

  • Yeo, Sujung;Chung, Jee Hyun;Kim, Young-Kon;Koo, Sungtae;Lee, Min Kyu;Lim, Sabina
    • Korean Journal of Acupuncture
    • /
    • v.31 no.3
    • /
    • pp.125-135
    • /
    • 2014
  • Objectives : Warm needling is the method combining the effects of acupuncture and moxibustion. In modern clinics, warm needling is only affected by treatment time or frequency. We need to study the physical characteristics of warm needles currently used in clinics in order to develop more efficient and economical treatments. Methods : We collected various warm needle specimens and analyzed chemical constitutions, measured heat transfer velocity, micro Vicker's hardness and specific resistance. We studied the relationship between heat transfer velocity and micro Vicker's hardness as well as that between heat transfer velocity and specific resistance. Results : The heat transfer velocity of the Silver_HL was 3.3 mm/sec, of the Au alloy group was 1.3~2.6 mm/sec, and Silver_IN, Silver_ZK and SS groups was less than 0.3 mm/sec. We therefore concluded that the needle composed of Ag has the best heat transfer velocity. In the Micro Vicker's hardness test, Vicker's hardness of the Au alloy group was 159~170 Hv, of Silver_HL was 181 Hv, and of the Silver_IN, Silver_ZK, SS group was 450.8~519 Hv. In the Silver_IN, Silver_ZK and SS groups, hardness was inversely proportial to thermal conductivity. In the specific resistance test, the specific resistance of Silver_HL was the lowest, that of the Au alloy group was the second lowest, and that of the Silver_IN, Silver_ZK, SS groups were the highest. Conclusions : We concluded that the needle composed of Ag has the best heat transfer velocity, highest electric conductivity and thermal conductivity, therefore the needle composed of Ag is suitable for warm needling.

Effects of the Non-equilibrium Heat-treatment on Modification of Microstructures of Al-Si-Cu Cast Alloy (비평형 열처리에 의한 주조용 Al-Si-Cu합금 조직의 개량 효과)

  • Kim, Heon-Joo
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.6
    • /
    • pp.391-397
    • /
    • 2000
  • Addition of Ca element and nonequilibrium heat treatment which promotes shape modification of eutectic Si and ${\beta}$ intermetallic compound were conducted to improve the mechanical properties of Al-Si-Cu alloy. Modification of eutectic Si and dissolution of needle-shape ${\beta}$ intermetallic compounds were possible by nonequilibrium heat treatment in which specimens were held at $505^{\circ}C$ for 2 hours in Al-Si-Cu alloy with Fe. Owing to the decrease in aspect ratio of eutectic Si by the heat treatment of the alloy with 0.33wt.% Fe, the increase in elongation was prominent to be more than double that in the as-cast specimen. Dissolution of needle-shape ${\beta}$ intermetallic compounds in the alloy with 0.85wt.% Fe led to the improvement of tensile strength as the length of ${\beta}$ compounds decreased to 50%.

  • PDF

Analysis on Combustion Characteristics of CRDi Single-cylinder Diesel Engine with Direct Needle-driven Piezo Injector (직접구동 피에조 인젝터의 CRDi 단기통 디젤엔진 연소 특성 분석)

  • Chung, Myungchul;Sung, Gisu;Kim, Sangmyung;Lee, Jinwook
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.5
    • /
    • pp.108-115
    • /
    • 2014
  • In this study, experimental approaching method was applied under and single-cylinder engine to research the performance of direct needle-driven piezo injector (DPI) for CR direct-injection. As key-point factor of this DPI that relies on direct-acting operating of injector needle, unlike conventional hydraulic-servo, its nozzle needle can be directly driven by piezo actuator. Thus, effect of direct-acting injection of DPI on diesel combustion and emission characteristics was investigated under common-rail single-cylinder direct-injection engine, equipped with three different driving mechanism, including indirect-acting solenoid, piezo and DPI system. As main results, it found that a direct-acting piezo injector has higher of IMEP. And it has higher heat release rate during premixed combustion and mixing controlled combustion phase due to its higher heat release, even though nitrogen oxide (NOx) formations were increased slightly.