Heat Generation Model of Angular Contact Ball Bearing with Oil-Air Lubrication

  • Na, Hee-Hyeong;Rhim, Yoon-Chul
    • KSTLE International Journal
    • /
    • 제1권1호
    • /
    • pp.63-68
    • /
    • 2000
  • Angular contact ball bearings are mainly used in the spindle, which requires high speed and stiffness. The heat generation is studied by experiments and simulations using a pair of angular contact ball bearings. The temperature variation of inner and outer races and the temperature increment distribution are measured by using thermocouples for the rotational speed, preload, viscosity of lubricant. The measured values from experiments are used to estimate the heat conduction rate. The method of oil-air lubrication is used for the experiment. The amount of conduction heat transfer to the test spindle and the convection heat transfer coefficients long the spindle are computed by using inverse method with temperature increment distribution. Total heat generation rate is estimated with the heat partition rate which is calculated from temperatures of inner and outer races. In addition, the empirical factor of oil-air lubrication method for Palmgren's heat generation model is suggested. The empirical friction coefficients, which are obtained from the experiments, depend on the preload condition, and can give us more accurate estimation of the heat generation in ball bearings.

  • PDF

Factors Affecting Performance of a Proto type Windheat Generation System

  • Kim Y.J.;Yun J.H.;Ryou Y.S.;Kang G.C.;Paek Y.;Kang Y.K.
    • Agricultural and Biosystems Engineering
    • /
    • 제6권1호
    • /
    • pp.22-26
    • /
    • 2005
  • A wind-heat generation system was developed and the system consisted of an electric motor, a heat generation drum, a heat exchanger, two circulation pumps and a water storage tank. The heat generation drum is an essential element determining performance of the system. Frictional heat was generated by rotation of a rotor in the drum filled with a working fluid, and the heat stored in the fluid was used to increase water temperature through the heat exchanger. Effects of some factors such as rotor shape, kind and amount of working fluid, rotor rpm and water flow rate in the heat exchanger, affecting the system performance were investigated. Amounts of heat generated were varied, ranging from 126,000 to 32,760 kJ/hr, depending on combination of the factors. Statistical analysis using GLM procedure revealed that the most influential factor to decide the system performance was amount of the fluid in the drum. Experiments showed that the faster the speed of the rotor, the greater heat was obtained. The greatest efficiency of the heat generation system, electric power consumption rate vs gained heat amount of water, was about 70%. Though the heat amount was not enough for plant bed heating of a 0.1-ha greenhouse, the system would be promising if some supplementary heat source such as air- water heat pump is added.

  • PDF

해수를 이용한 화력발전소 폐열회수 히트펌프 시스템 (Heat Pump System Using Heated Effluent of Thermal Power Generation Plant as a Heat Source)

  • 유영선;강연구;김영화;장재경;김종구;이형모;강금춘;나규동;허태현
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.190-190
    • /
    • 2011
  • In South Korea the gross generation and heated effluent of power generation plant was 259 TWh and 4.73 billion tons in 2008. And then the waste heat from power generation was 388 TWh. It shows that the efficiency of thermal power generation plant is about 40%. Therefore to reduce $CO_2$ emission from thermal power generation plant, the energy of this heated effluent must be reused to heat buildings or farm facilities. In South Korea horticultural facilities of about 25% are heated in winter season. Total area of greenhouses which are heated is about 13,000 ha. Total heat amount needed to warm greenhouse of 13,000 ha in winter season is only 3.4% of total waste heat from power generation plant. In this study a heat pump system was designed to reuse the waste heat from power generation. Especially new heat exchanger was developed to recover the thermal energy from waste water and this model considered anti-corrosion against sea water and low cost for economic feasibility. This heat recovery system was installed in mango growing greenhouse around thermal power generation plant in Seogwipo-city, Jeju Special Self-Governing Province. The result of preliminary test shows that the heating cost of about 90% is saved as compared to boiler using tax free light oil as a fuel.

  • PDF

An Experimental Study on a Windheat Generation System with a Savonius Wind Turbine

  • Kim, Young-Jung;Ryou, Young-Sun;Kang, Geum-Choon;Paek, Yee;Yun, Jin-Ha;Kang, Youn-Ku
    • Agricultural and Biosystems Engineering
    • /
    • 제6권2호
    • /
    • pp.65-69
    • /
    • 2005
  • A windheat generation system with a Savonius windturbine was developed and the performance was evaluated through field tests. The system consisted of a heat generation drum, heat exchanger, water storage tank, and two circulation pumps. Frictional heat is created by rotation of a rotor inside the drum containing thermo oil, and was used to heat water. In order to estimate the capacity of this windheat generation system, weather data was collected for one year at the site near the windheat generation system. Wind Power from the savonius wind turbine mill was transmitted to the heat generation system with an one-to-three gear system. Starting force to rotate the savonius wind turbine and the whole system including the windheat generation system were 1.0 and 2.5 kg, respectively. Under the outdoor wind condition, maximum speed of the rotor in the drum was 75rpm at wind speed 6.5 m/sec, which was not fast enough to produce heat for greenhouse heating. Annual cumulative hours for wind speeds greater than 5 m/sec at height of 10, 20, 30 m were 190, 300 and 1020 hrs, respectively. A $5^{\circ}C$ increase in water temperature was achieved by the windheat generation system under the tested wind environment.

  • PDF

도시의 인공열 산정에 관한 연구 (Study on Estimation of Urban Anthropogenic Heat Generation)

  • 손은하;김유근;홍정혜
    • 한국대기환경학회지
    • /
    • 제16권1호
    • /
    • pp.37-47
    • /
    • 2000
  • The Urban thermal environment is influenced and modified in many ways. One modification is brought by the anthropogenic heat generation emitted from the combustion processes and the use of energy such as industrial, domestic and traffic procedure. The anthropogenic heat generation affect an the increase of urban temperature, the well-known urban heat islands. The study on the urban thermal environment needs a great deal of the statistic data about the inner-structure of urban, the contribution of different constructions and the traffic amount on urban thermal environment in finite region. In order to overtake a quantitative analysis of effect of the anthropogenic heat, a distribution map of the urban anthropogenic heat was made using hte data of the energy consumption used at the several constructions and traffic amount of vehicles in Pusan Metropolitan. Annual mean heat flux over the 4$\textrm{km}^2$ urbanized area in Pusan is 41.5W/$m^2$, ranging from 31.4W/$m^2$ in summertime to 59.5W/$m^2$ in wintertime and maximum diurnal anthropogenic heat generation is corresponding to 10% of irradiance during summertime.

  • PDF

파형 충돌분류의 열전달 특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Characteristics of Corrugated Impinging Jets)

  • 김예용;김귀순
    • 대한기계학회논문집B
    • /
    • 제23권3호
    • /
    • pp.320-329
    • /
    • 1999
  • An experimental study has been performed to investigate the heat transfer characteristics of impinging jets with corrugated nozzle and wake generation plate. Three different shapes of corrugated nozzle and five different shapes of wake generation plate were tested to improve the heat transfer characteristics of impinging jet. Heat transfer coefficients were obtained by using transient method based on the liquid crystal thermography. The effects of corrugated nozzle and wake generation plate on the heat transfer characteristics of impinging jets were discussed in detail. The results showed that both the corrugated nozzle and the wake generation plate improved the heat transfer characteristics of impinging jet. Especially, heat transfer coefficients around stagnation region of impinging jets were highly increased.

서버 컴퓨터의 발열량이 변화한 경우의 데이터센터 내의 기류 및 온도분포 특성에 대한 연구 (A Study on the Distribution of Airflow and Temperature in a Data center under the Various Conditions of Heat Generation Rates of Server Computers)

  • 장현재;김제영
    • 설비공학논문집
    • /
    • 제26권3호
    • /
    • pp.108-114
    • /
    • 2014
  • On a large scale of data center, heat generation rates from sever computers occupy almost the entire cooling load of the building, and it is gradually increasing. The efficiency of air distribution system in data centers can be affected by heat generation rates of server computers. In this study, the distributions of airflow and temperature in a data center have been investigated by CFD simulations under various conditions of heat generation rates for server computers. From the results, air around the cold aisle which has high temperature flows tremendously into the cold aisle according to the increase of heat generation rates for server computers and the air temperature in the cold aisle becomes higher. The SHI (supply heat index) and RHI (return temperature index) show almost similar values to the cases study because the air inflow rates to server computers increase with the heat generation rates of server computers.

열전발전 적용을 위한 가솔린차량의 전력 및 배기열 에너지 분석 연구 (Analysis of the Electric Energy and Exhaust Heat Energy for the Application of Thermo-Electric Generation in a Gasoline Vehicle)

  • 이영재;표영덕;김강출
    • 한국자동차공학회논문집
    • /
    • 제10권1호
    • /
    • pp.99-105
    • /
    • 2002
  • About 70% of energy input to internal combustion engine is rejected to atmosphere by heat. By utilizing this waste heat, a plenty of energy can be conserved in nationwide. One of possible ways is the thermoelectric generation to utilize engine's waste heat to provide auxiliary electric power. Under th is concept, we have been developing the thermoelectric generation system to replace the alternator by converting the waste heat in the engine's exhaust directly to electricity This system may reduce the shaft horse power of the engine, then improves the vehicle fuel economy and the exhaust emissions. In the present study, the characteristics of the electric energy and exhaust heal energy in city and highway mode driving conditions are analysed by using a gasoline passenger car. These results would be used to determine the optimum design parameters of the thermoelectric generation system.

가변 열전비를 갖는 열병합 발전설비가 포함된 마이크로그리드의 최적 운용 (Optimal Microgrid Operation Considering Combined Heat and Power Generation with Variable Heat and Electric Ratio)

  • 이지혜;박재세
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1548-1553
    • /
    • 2012
  • The important requirement for microgrid operation is to meet the balance between supply and demand. To meet, Combined Heat and Power (CHP) generation should be considered in microgrid scheduling. CHP generation is economical on the side of a consumer because it products heat and power. Therefore, it is high efficient. This paper presents a mathematical model for optimal microgrid operation including CHP generation using the optimal ratio of heat and power due to demand. The objective function and constraints are modeled by linear program (LP). Through the case study, the validation of the proposed model is shown.

볼 베어링의 운전조건에 따른 발열 특성 (Heat Generation Characteristics of Ball Bearing for Operating Conditions)

  • 장윤석;나희형;임윤철
    • Tribology and Lubricants
    • /
    • 제13권4호
    • /
    • pp.26-32
    • /
    • 1997
  • The heat generation of the angular contact and the deep groove ball bearing is studied experimentally and numerically. The temperature variation of the inner and outer races and the temperature increase distribution are measured for the shaft rotational speeds, preloads, viscosities of the lubricant and lubrication methods. The measured temperature distributions are used as the input data of the numerical simulation to estimate the heat generation rate at the bearing. The temperatures of the inner and outer race increase more rapidly and approach faster to their steady values as the rotational speed increases. The optimal viscosity of the oil to minimize the heat generation is 8~10 cSt at 4$0^{\circ}C$ when the oil-air lubrication method is adopted. The heat generation of the bearing increases with the rotational speed and depends more on the lubrication method than on the preload variation.