• 제목/요약/키워드: heat exchangers

검색결과 853건 처리시간 0.023초

직관 마이크로채널 PCHE의 열전달특성 및 압력강하 (Heat Transfer Characteristics and Pressure Drop in Straight Microchannel of the Printed Circuit Heat Exchangers)

  • 김윤호;문정은;최영종;이규정
    • 대한기계학회논문집B
    • /
    • 제32권12호
    • /
    • pp.915-923
    • /
    • 2008
  • The performance experiments for a microchannel printed circuit heat exchanger (PCHE) of high-performance and high-efficiency on the two technologies of micro photo-etching and diffusion bonding were performed in this study. The microchannel PCHE were experimentally investigated for Reynolds number in ranges of 100 $\sim$ 700 under various flow conditions in the hot side and the cold side. The inlet temperatures of the hot side were conducted in range of $40^{\circ}C\;{\sim}\;50^{\circ}C$ while that of the cold-side were fixed at $20^{\circ}C$. In the flow pattern, the counter flow was provided 6.8% and 10 $\sim$ 15% higher average heat transfer rate and heat transfer performance than the parallel flow, respectively. The average heat transfer rate, heat transfer performance and pressure drop increases with increasing Reynolds number in all the experiment. The increasing of inlet temperature in the experiment range has not an effect on the heat transfer performance while the pressure drop decrease slightly with that of inlet temperature. The experimental correlations to the heat transfer coefficient and pressure drop factor as a function of the Reynolds number have been suggested for the microchannel PCHE.

지열원 히트펌프 유닛 인증 현황 및 성능 분석에 관한 연구 (A Study on the Certified Ground Source Heat Pump and Performance Analysis)

  • 양찬우;강희정;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.22-32
    • /
    • 2022
  • To reduce energy consumption and CO2 emission in building sector, a ground source heat pump system has been highly adopted due to its high efficient by many regulation. A certification system has been operated to distribute reliable and high-efficient heat pump units. In this study, the performance status of the recently certified ground source heat pump unit with components was investigated. All heat pump units certified from 2015 to 2020 were water to water heat pump types. Compared to the past, higher capacity systems over 400 kW have been certificed. The cooling COP of the heat pump unit based on certification criteria showed higher value than the heating COP. It is highly recommended to revise the certified criteria values considering operating conditions individually. Most of ground source heat pump units have employed scroll type compressors and plate type heat exchangers with HFC refrigerant.

에어컨 실외기용 휜-관 직교형 열교환기의 열, 유동 해석 및 휜 성능 개선을 위한 연구 (Flow and heat transfer analysis for the performance improvement of cross-flow fin-tube heat exchangers)

  • 안진수;최도형
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.183-189
    • /
    • 2004
  • The flow and the heat transfer about the cross-flow fin-tube heat exchanger in an out-door unit of a heat pump system has been numerically Investigated. Using the general purpose analysis code, FLUENT, the Navier-Stokes equations and the energy equation are solved for the three dimensional computation domain that encompasses multiple rows of the fin-tube. The temperature on the fin and tube surface is assumed constant but compensated later through the fin efficiency when predicting the heat-transfer rate. The contact resistance is also taken into consideration. The flow and temperature fields for a wide range of inlet velocity and fin-tube arrangements are examined and the results are presented in the paper. The details of the flow are very well captured and the heat transfer rate for a range of inlet velocity is in excellent agreement with the measured data. The flow solution provides the effective permeability and the inertial resistance factor of the heat exchanger if the exchanger were to be approximated by the porous medium. This information is essential in carrying out the global flow field calculation which, in turn, provides the inlet velocity lot the microscopic temperature-field calculation of the heat exchanger unit.

  • PDF

내부 그루브를 가진 열사이폰의 작동유체 봉입량 변화에 따른 열전달 성능에 관한 연구 (A Study on Heat Transfer Performance with the Changes of Working Fluid Filling Ratio for Thermosyphon with Internal Groove)

  • 예석수;한규일
    • 동력기계공학회지
    • /
    • 제4권3호
    • /
    • pp.19-24
    • /
    • 2000
  • This study concerns the performance of the heat transfer of the thermosyphon having 80 internal groove in which boiling and condensation occur. Distilled water has been used as a working fluid. The liquid filling as the ratio of working fluid volume to total volume of thermosyphon has been used as the experimental parameters. The heat flux and heat transfer coefficient at the condenser are estimated from the experimental results. The experimental results have been assessed and compared with the existing theories. As a result of the experimental investigation, the maximum heat flow rate in the thermosyphon is proved to be dependent upon the liquid fill quantity. relatively high rates of heat transfer have been achieved operating in the thermosyphon with the internal groove. Also, a thermosyphon with the internal groove can be used to achieve some inexpensive and compact heat exchangers in low temperature. In addition, overall heat transfer coefficients and the characteristics as an operating temperature are obtained for the practical applications.

  • PDF

직렬 4원주 주위의 유체유동 및 열전달에 관한 실험적 연구 (An Experimental Study on Fluid Flow and Heat Transfer Around Four Circular Cylinders of In-line)

  • 최순열;김민수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권5호
    • /
    • pp.691-697
    • /
    • 2008
  • Heat exchangers are commonly used in practice in a wide range of application, from heat and air-conditioning system in a household, to chemical processing and power production in large plant. An Experimental study was conducted to investigated the fluid flow and heat transfer around four circular cylinders of in-line in a cross flow of air. The local and average heat transfer characteristics for tube banks are investigated in the present study. Heat transfer in a heat exchanger usually involves convection in each fluid and conduction through the wall separating the two fluid. The in-line pitch ratio was in the range $1.5{\leq}L/d{\leq}4.0$, where L is the center distance and d the cylinder diameter, and in the Reynolds number $8,000{\leq}Re{\leq}50,000$. The local and mean Nusselt numbers were estimated. Subsequently, the heat transfer characteristics of four circular cylinders are found to exhibit a strong dependency upon the separation point of their upstream cylinders.

저심도 대구경 지중열교환기의 설치조건에 따른 성능 연구 (Performance Evaluation of Large Borehole Ground-Loop Heat Exchanger)

  • 유규상;박일문;최재호;신현준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.58-63
    • /
    • 2009
  • A ground-loop heat exchanger for the ground source heat pump system is the core equipment determining the thermal performance and initial cost of the system. The size and performance of the heat exchanger is highly dependent on the ground thermal properties - the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. Nowadays, precast concrete piles using steel reinforced precast concrete piles - energy piles - are used to reduce the installing cost of the ground-loop heat exchanger. We were carried out some tests to investigate the effects of some parameters such as borehole length, grouting materials and U-tube configuration of the energy piles. 4 concrete piles, each measuring $250mm{\sim}400mm$ in diameter and approx. 10m in length, and rigged with single spiral and 3 U-tube loop of $16mm{\times}2.3mm$ PB piping. The thermal response tests were conducted using a testing device for 4-different ground-loop heat exchangers. During the heating period, the energy piles absorb the heat of 0.89kW to 1.37kW.

  • PDF

R-22를 사용한 용접형 판형 열교환기의 응축열전달 및 압력강하 특성에 관한 연구 (Study on Condensation Heat Transfer and Pressure Drop Characteristics of R-22 in Brazed Plate Heat Exchanger)

  • 전창덕;권오갑;이진호
    • 대한기계학회논문집B
    • /
    • 제25권2호
    • /
    • pp.171-179
    • /
    • 2001
  • Experimental study has been carried out on the characteristics of pressure drop and heat transfer of brazed plate heat exchangers using R-22. Data are presented for the following range of variables: the mass flux (40∼90kg/$m^2$s), chevron angle ($20^{\circ}$, $35^{\circ}$, $45^{\circ}$) and inlet pressure of the refrigerant (1.4 and 1.6MPa). For both subcooled and two-phase flow, as chevron angle increases, pressure drop and heat transfer coefficient decrease. Condensation heat transfer coefficient and pressure drop were compared with the previously proposed correlations. Among therm, Traviss correlation agreed with experimental results within -40%∼-84% for heat transfer coefficient and -59%∼62% for pressure drop.

열교환기 모델내 하천수와 시수의 Fouling 특성 비교 (A Comparative Study on the Fouling Characteristics of River and Tap Water in a Heat Exchanging Model)

  • 성순경;서상호;노형운
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.49-54
    • /
    • 2003
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When scale deposits in a heat exchanging surface, it is traditionally called fouling. The objective of the present study was to compare the fouling characteristics of river and tap water in a heat exchanging model. FromtheSEM analyses for tap water the $calciteformofCaCO3_{3}$ was formed. For river water, however, the $aragoniteCaCO_{3}$ wasformed.In order to investigate velocity effects on the fouling characteristics in the heat exchanging model, the inlet velocity was varied with 0.5, 1.0 and 1.5 m/s, respectively. The fouling characteristics of river water were quite different from those of tap water. For the case of the 'velocity of 1.5m/s', the overall heat transfer coefficient was reduced up to 26% than that of the 'velocity of 0.5m/s'

  • PDF

레이놀즈 수가 낮은 영역에서 와류발생기를 적용한 핀-관 열교환기 성능평가 (Performance Evaluation of Finned Tube Heat Exchanger with Vortex Generators in a Low Reynolds Number Regime)

  • 곽경민;송길달
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.151-157
    • /
    • 2006
  • The present paper reports the method for evaluation of heat-transfer performance of finned tube heat exchangers in a low Reynolds number regime (Re = $160\~800$) and also reports the data of heat transfer and pressure loss taken from a finned tube heat exchanger with/without vortex generators (VGs) installed as a heat-transfer enhancement device. The evaluation is based on the modified single blow method conducted in a specially designed low Reynolds number duct. Three different test core geometries, i.e., fin only, fin-tube without VGs and that with VGs, are studied here. The data of heat transfer and pressure loss taken from the fin only geometry agree well with the empirical correlations, thus validating the present method as used for low Reynolds number regime. The data taken from the finned tube geometries with and without VGs are presented and compared to examine the effect of VGs in the low Reynolds number regime.

건물 기초를 이용한 지중열 공조시스템의 개발에 관한 연구 (1) (A Study on Development of a Ground-Source Heat Pump System Utilizing Pile Foundation of a Building)

  • 오오카 료죠;남유진;세키네 켄타로;요코이 무츠미;시바 요시로;황석호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.148-154
    • /
    • 2005
  • Ground-source (Geothermal) heat pump (GSHP) systems can achieve a higher coefficient of performance than conventional air-source heat pump (ASHP) systems. However, GSHP systems are not widespread in Japan because of their expensive boring costs. The authors have developed a GSHP system that employs the cast-in-place concrete pile foundations of a building as heat exchangers in order to reduce the initial boring cost. In this system, eight U-tubes are arranged around the surface of a cast-in-place concrete pile foundation. The heat exchange capability of this system, subterranean temperature changes and heat pump performance were investigated in a foil-scale experiment. As a result, the average values for heat rejection were 186${\sim}$201 W/m (for pile, 25 W/m per Pair of tubes) while cooling. The average COP of this system was 4.6 while cooling; rendering this system more effective in energy saving terms than the typical ASHP systems. The initial cost of construction per unit for heat extraction and rejection is ${\yen}$72/W for this system, whereas it is f300/W for existing standard borehole systems.

  • PDF