• 제목/요약/키워드: heat exchange

검색결과 766건 처리시간 0.027초

지열 히트펌프 시스템의 계절별 지중 열교환 특성 및 지반내 온도 변화 (Temperature monitoring and seasonal borehole heat exchange rate characteristics of a geothermal heat pump system)

  • 심병완
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.452-455
    • /
    • 2007
  • The geothermal heat pump system is designed for cooling and heating for three stories building (2,435 $m^2$) includes total 79 heat pumps. Therefore, the monitoring system is installed for each floor and the data is automatically transmitted to the monitoring system. Heat exchange rate and temperature of a geothermal heat pump system have been monitored for a long period. The seasonal operation of geothermal heat pump shows the different shape of heat exchange rate for cooling and heating. Ground water flow can influence on heat exchange rate and thermal storage of the system. In order to define the hydraulic characteristics and groundwater temperature variation, the relationships among air temperatures, groundwater temperatures, water table, and precipitation are analysed.

  • PDF

다공형 전열판의 회전에 의한 열교환시스템의 성능에 관한 연구(Ⅰ) - 환기측과 외기측의 풍량 변화에 대하여 - (Study on the Performance of Total Heat Exchanger with Rotating Porous Plates)

  • 조동현;임태우
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.11-17
    • /
    • 2005
  • This paper reports an experimental study on the performance evaluation of air-to-air heat exchanger with rotary type newly developed in this study. Air flow rate is varied from 10 to 120 m3/h. The range of RPM of the porous rotating discs mounted inside the heat exchanger unit is 0 to 50. The temperature of the return air side is set by adjusting heat supply at heater. The material of the porous rotating discs is cooper and its thickness is 1.0 mm. The heat transfer rate increased with the increase in air flow rate. It was found that the heat transfer rate, as the temperature of the return air side was increased, was improved due to higher temperature difference. The heat exchange performance increased with the increase in the temperature of the return air side at the conditions of the same RPM. The sensible heat exchange efficiency was maximum 68 to 76 percent, and enthalpy exchange efficiency 64 to 74 percent.

  • PDF

겔 상태의 미세 잠열 축열재 혼합수의 기액직접접촉식 열교환법에 의한 방열 특성 (A Study on the Heat Release Characteristics of Gel Type Micro Size Latent Heat Storage Material Slurry with Direct Contact Heat Exchange Method)

  • 김명준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.618-623
    • /
    • 2004
  • This paper has dealt with the heat storage characteristics of gel type micro size latent heat storage material slurry. The heat release operation to the gel type micro size latent heat storage material slurry was carried out using hot air bubbles by direct contact heat exchange. This experiment was carried out using phase change material of n-paraffin so the heat release amount is higher than cold water system. The parameters of this experiment were concentration of latent heat phase change material, height of heat release bath and inlet velocity of hot air. The main results obtained are as follows : (1) The effect of concentration of latent heat phase change material dispersed with water is very affective to the direct contact heat exchange between hot air and gel type micro size latent heat storage material slurry. (2) It is clarified that the most effective concentration of latent heat phase change material dispersed with water exists around 20mass% at this type of direct heat exchange model experiment.

플라스틱 온실(溫室)의 열저장(熱貯藏) 시스템 개발(開發)에 관(關)한 연구(硏究)(I) -수막식(水膜式) 열교환(熱交換) 시스템의 개발(開發)- (Development of Thermal Storage System in Plastic Greenhouse (I) -Development of Air-Water Heat Exchange System-)

  • 김용현;고학균;김문기
    • Journal of Biosystems Engineering
    • /
    • 제15권1호
    • /
    • pp.14-22
    • /
    • 1990
  • For efficient use of solar energy in plastic greenhouse, thermal storage system was developed. The system was constructed with the counter-flow type air-water heat exchanger using a thin polyethylene film as a medium of heat exchange parts. Experiments were carried out to investigate the heat exchange rate, optimum water flow rate, overall heat transfer coefficient, and the effectiveness of the counter-flow type air-water heat exchanger with polyethylene film bags. Mathematical model to predict air temperature leaving heat exchanger was developed. The results obtained in the present study are summarized as follows. 1. Heat exchange rate in the counter-flow type air-water heat exchanger with polyethylene film bags was compared to that of polyethylene film. Heat exchange rate was almost identical at air velocity of 0.5m/s on polyethylene film surface. But, heat exchange rate of heat exchanger with polyethylene film bag was $32{\sim}55KJ/m^2$ hr higher than that of polyethylene film at air velocity of 1.0m/s. 2. Considering the formation of uniform water film and the sufficient heat exchange rate of polyethylene film bags, optimum water flow rate in polyethylene film bags was $3.0{\sim}6.0{\ell}/m^2$ min. 3. The overall heat transfer coefficient of polyethylene film bags was found to be $35.0{\sim}130.0KJ/m^2\;hr\;^{\circ}C$ corresponding to the air velocity ranging 0.5 to 4.0 m/s on polyethylene film surface. And the overall heat transfer coefficient showed almost linearly increasing tendency to the variation of air velocity. 4. Mathematical model to predict air temperature leaving the heat exchanger was developed, resulting in a good agreement between the experimental and predicted values. But, the experimental results were a little lower than predicted. 5. Effectiveness of heat exchanger for the experiment was found to be 0.40~0.81 corresponding to the number of transfer units due to the variation of air velocity ranging 0.6 to 1.7 m/s.

  • PDF

폐열회수 환기장치의 열교환 효율 개선을 위한 전산수치해석 (Numerical Analysis of Wasted Heat Recovery Ventilator for Improving the Heat Exchange Efficiency)

  • 김현일;김재성;박철우;박경서
    • 한국CDE학회논문집
    • /
    • 제17권1호
    • /
    • pp.54-61
    • /
    • 2012
  • In this paper, we performed numerical analysis to improve the heat exchange efficiency of wasted heat recovery ventilator which has a delivery and a exhaustion fan. One of the most important design factors that affect the efficiency of heat exchange is uniform counter-flow between inbound and outbound air flows. We had simulated several types of porous plates which were installed at air intake area. With plate having 45 degrees of installation angle and 15 mm diameter holes which are uniformly arranged, we can generate a uniform air flows at the area of porous media where inbound and outbound air flows are cross over. In addition, we installed a duct to reduce vortex flows at the outlet and to discharge exhaust airs rapidly. By using the proposed numerical assessment, we expect the improvement of the heat exchange efficiency of ventilator.

다공형 전열판의 회전에 의한 열교환시스템의 성능에 관한 연구(Ⅱ) - 전열판의 회전수 변환에 대하여 - (Study on the Performance of Total Heat Exchanger with Rotating Porous Plates)

  • 임태우;조동현
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.18-23
    • /
    • 2005
  • The experimental investigation was carried out to evaluate the performance of air-to-air heat exchanger with rotating porous plates newly developed in this study. The rotating porous plates are mounted with an equal interval of 18 mm inside the heat exchanger where the hot and cold airs enter at opposite ends. When flowing in opposite directions by the separating plate installed in the center of the rotating porous plates, the airs give and receive the heat each other. The material of the porous plate is cooper and its thickness is 1.0 mm. Air flow rate is varied from 10 to 120 m3/h. From the experiment of air-to-air heat exchanger with the rotating porous plates, the heat exchange performance increased with the increase in RPM of the porous rotating discs at the conditions of the same air flow rate. The sensible heat exchange efficiency was maximum 60 to 70 percent, and enthalpy exchange efficiency 50 to 60 percent.

  • PDF

거주공간에서의 복선열교환에 관한 연구 -착의시의 착의부와 노출부의 열수수 (A study on the radiant heat exchange in living space)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제24권2호
    • /
    • pp.75-82
    • /
    • 1986
  • This study was measured experimentally the Configuration factor of the adult female with the purpose of explaning quantitatively the human body's radiant heat exchange in a small scale of a house. And it is a investigatio about human clothed body's heat resistance which have great influence on radiant heat exchange. The result of this study was diagrammatized the [Shape×Area Factor] for the sake of making it easy to calculate the quantity of the actual human body's radiant heat exchange, and designed a diagram to make it easy to find the value of the human clothed body's heat resistance and clothing surface temperature. Thus, this research can be used as a basic resource for not only calculating wuantitatively radiant heat exchange of human clothed body and unclothed body in the radiant heating system of low temperature but also designing the thermal environment in a room.

  • PDF

EGR 쿨러 Type에 따른 열교환성능에 관한 실험적 연구 (An Experimental Study on the Heat Exchange Performance at Various EGR Cooler Types)

  • 손정욱;우승철;박종욱;전태수;이기형
    • 한국자동차공학회논문집
    • /
    • 제23권6호
    • /
    • pp.608-614
    • /
    • 2015
  • Nitrogen oxide(NOx) emission reductions are required to meet the strict emission regulations for environmental protection. Most of the Exhaust Gas Recirculation(EGR) system applied to a diesel engine can relatively decrease the NOx at a low cost, but it has a disadvantage in that the PM generation is promoted due to the hot intake air temperature. Thus, high heat exchange efficiency of the EGR cooler is required for an effective removal of NOx. In this study, heat exchange efficiency for various types of heat exchangers used in EGR cooler was measured under same conditions, and determined best heat exchange performance shape depending on type of heat exchanger.

등가열교환율을 적용한 현장타설 에너지파일 설계법 (Design Method for Cast-in-place Energy Pile Considering Equivalent Heat Exchange Rate)

  • 민선홍;박상우;정경식;최항석
    • 대한토목학회논문집
    • /
    • 제33권3호
    • /
    • pp.1049-1061
    • /
    • 2013
  • 본 연구에서는 현장타설 에너지파일의 열교환 파이프 배치 형태별 열교환율을 전산유체해석 프로그램(FLUENT)을 이용하여 평가하고, 이를 이용하여 에너지파일의 설계법을 제시하였다. 등가열교환율을 산정하기 위해 동일한 현장타설말뚝 제원에 대해 열교환파이프 배치 형태를 W-형(직렬), 복합 U-형(병렬 4쌍), 나선형의 3가지로 고려하였다. 건물측 부하조건은 여름철 냉방운용를 모사하기 위해 순환수의 에너지파일 유입온도, 즉 히트펌프 유출온도(Leaving water temperature, LWT)를 $35^{\circ}C$로 일정하게 유지하여 에너지파일 유출온도, 즉 히트펌프 유입온도(Entering water temperature, EWT) 변화를 관찰하였다. 지반에 최대 가상부하를 적용한 경우(100시간 연속 냉방부하 조건)에는 3가지 열교환기 형태가 유사한 열교환율을 보인 반면, 실제 히트펌프 가동에 의한 건물 냉방운용을 모사하기 위해 간헐적으로 일일 8시간 운용-16시간 정지를 7일간 반복 해석한 경우에는 W-형(직렬연결)과 복합 U-형(병렬 4쌍) 열교환기는 유사한 열교환율을 보이나, 나선형 열교환기는 파이프 루프 상호 간 열간섭으로 인해 복합 U-형 열교환기에 비해 약 86%의 열교환율을 갖는 것으로 평가되었다. 전산유체해석에 의해 계산된 열교환파이프 배치 형태별 에너지파일의 등가열교환율을 에너지파일 설계프로그램(PILESIM2)에 적용하여 다양한 형상의 현장타설 에너지파일에 대한 설계법과 대표적인 설계변수에 대한 설계도표를 제시하였다.

공동주택용 폐열회수형 환기장치의 성능에 관한 측정 연구 (A Study on the Performance of Heat Recovery Ventilators for Apartment Houses)

  • 장현재;홍석진
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.26-34
    • /
    • 2008
  • Heat recovery ventilator(HRV) is recommended to improve indoor air quarlity (IAQ) and energy conservation in apartment houses. Recently, in Korea, HRV is produced from many manufacturers. However, there have been not so many experiences to apply HRV in apartment houses and verification on the performance such as heat exchange efficiency, carry-over rate, internal leakage, etc. have not been carried out sufficiently. So in this study, fan performance, heat exchange efficiency, air leakage, internal exhaust leakage, external leakage and sound level of HRV were examined for selected HRV models under domestic and international standard. Results of performance test, there were need to improve latent heat exchange efficiency and sound level of HRV.