• 제목/요약/키워드: heat equivalent

검색결과 416건 처리시간 0.023초

도시식생의 주택에너지절약 및 탄소배출저감 기능 -춘천시를 대상으로- (Function of Home Energy Savings and Carbon Emission Reduction by Urban Vegetation- Case of Chuncheon-)

  • 조현길;서옥하;한갑수
    • 한국조경학회지
    • /
    • 제26권3호
    • /
    • pp.104-117
    • /
    • 1998
  • Rising concern about climate change has evoked interest in the potential for urban vegetation to help reduce the level of atmospheric CO\sub 2\, a major heat-trapping gas. This study quantified the functio of home energy savings and carbon emission reduction by shading, evapotranspiration and windspeed reduction of urban vegetatioin in Chuncheon. Tree and shrub cover averaged approximately 13% in residential land. The effects of shading, evapotranspiration and windspeed reduction annually saved heating energy by 2.2% and cooling energy by 8.8%. The heating and cooling energy savings reduced carbon emissions by 3.0% annually. These avoided emissions equaled the amount of carbon emitted annually from fossil fuel consumption by a population of about 1,230. Carbon emission reduction per residential building was 55kg for detached buildings and 872 kg for multifamily buildings. Urban vegetation annually decreased heating and cooling energy cost by ₩1.1 billions, which were equivalent to annual savings of ₩10,000 savings and carbon emission reduction due to tree plantings in the wrong locations, while windspeed reduction had a great effect. Plantings fo large trees close to the west and east wall of buildings, full tree plantings on the north, and avoidance of shade-tree plantings or selection of solar-friendlytrees on the south were recommended to improve the function of building energy savings and carbon emission reduction by urban vegetation.

  • PDF

선형접합기를 이용한 Si II 1.3$\mu\textrm{m}$-SiO$_2$/1.3$\mu\textrm{m}$-SiO$_2$ II SOI 기판의 직접접합 (Direct Bonding of Si II 1.3$\mu\textrm{m}$-SiO$_2$/1.3$\mu\textrm{m}$-SiO$_2$ II SOI substrates prepared by FLA method)

  • 송오성;이영민;이상현;이진우;강춘식
    • 한국표면공학회지
    • /
    • 제34권1호
    • /
    • pp.33-38
    • /
    • 2001
  • 10cm-diameter Si(100)∥$1.3\mu\textrm{m}$-X$1.3_2$X$1.3\mu\textrm{m}$-$SiO_2$∥Si(100) afers were prepared using a fast linear annealing (FLA) equipment. 1.3$\mu\textrm{m}$-thick $SiO_2$ films were grown by dry oxidation process. After cleaning and premating the wafers in a class 100 clean room, they were heat treated using with the FLA and conventional electric furnace. Bonded area and bond strength of wafer pairs were measured using a infrared (IR) camera and razor blade crack opening method, respectively. It was confinmed that the bonded area by FLA was around 99% and the bond strength value reached 2172mJ/$\m^2$, which is equivalent to theoritical bond strength. Our result implies that thick $SiO_2$ SOI may be prepared more easily by using $SiO_2$$SiO_2$ bonding interfaces then those of Si/$SiO_2$'s.

  • PDF

열연 슬라브 압연에서 워크롤 표면 원주방향 인장응력 감소를 위한 냉각 방법 (A Cooling Method which Reduces the Tangential Tensile Stresses on a Work Roll Surface during Hot Slab Rolling)

  • 나두현;이영석
    • 소성∙가공
    • /
    • 제21권1호
    • /
    • pp.58-66
    • /
    • 2012
  • The work roll surface temperature rises and falls repetitively during hot slab rolling because the work roll surface is cooled continuously by water. This study focused on Std. No. 7 to determine a cooling method which significantly reduces the tangential tensile stresses on the work roll surface of the hot slab mill at Hyundai Steel Co. in Korea. A series of finite element analyses were performed to compute the temperature distribution and the tensile stresses in the circumferential direction of the work roll. The virtual slab model was used to reduce the run time considerably by assigning a high temperature to the virtual slab. Except for the heat generated by plastic deformation, this is equivalent to the hot rolling condition that a high temperature slab (material) would experience when in contact with the work rolls. Results showed that when the virtual slab model was coupled with FE analysis, the run time was found to be reduced from 2000 hours to 70 hours. When the work roll surface cooled with a certain on-off patter of water spray, the magnitude of the tangential stresses on the work rolls were decreased by 54.1%, in comparison with those cooled by continuous water spraying. Savings of up to 83.3% in water usage are possible if the proposed water cooling method is adopted.

가솔린 엔진개조 CNG 발전기 개발과 동급 디젤엔진의 배출가스 특성 연구 (Development of Gasoline Engine Renewal CNG Generator and a Study on Exhaust Gas Characteristics of Equivalent Diesel Engine)

  • 이정천;김기호;이정민;박언영
    • 동력기계공학회지
    • /
    • 제22권6호
    • /
    • pp.74-79
    • /
    • 2018
  • Compressed natural gas has a high octane number and low particulate emission characteristics as compared with petroleum-based fuels, so it can respond to exhaust gas regulations positively. A natural gas engine has been introduced to improve the quality of the atmosphere, a diversity of fuel, a stable supply, and it has widely been used in city buses and garbage trucks. Recently, the natural gas engine has received attention by overcoming the disadvantage of the theoretical air-fuel ratio method through the development of EGR cooler and engine parts with the development of LP-EGR technology. In this study, we try to develop the cogeneration system that can simultaneously generate electric power and heat by remodeling the gasoline engine to the mixer type CNG engine. As a result, it was able to reduce the NOx (approximately 77%) compared to the diesel engines with same displacement.

Crack growth rate evaluation of alloys 690/152 by numerical simulation of extracted CT specimens

  • Lee, S.H.;Kim, S.W.;Cho, C.H.;Chang, Y.S.
    • Nuclear Engineering and Technology
    • /
    • 제51권7호
    • /
    • pp.1805-1815
    • /
    • 2019
  • While nickel-based alloys have been widely used for power plants due to corrosion resistance and good mechanical properties, during the last couple of decades, failures of nuclear components increased gradually. One of main degradation mechanisms was primary water stress corrosion cracking at dissimilar metal welds of piping and reactor head penetrations. In this context, precise estimation of welding effects became an important issue for ensuring reliability of them. The present study deals with a series of finite element analyses and crack growth rate evaluation of Alloys 690/152. Firstly, variation of residual stresses and equivalent plastic strains was simulated taking into account welding of a cylindrical block. Subsequently, extraction and pre-cracking of compact tension (CT) specimens were considered from different locations of the block. Finally, crack growth curves of the alloys and heat affected zone were developed based on analyses results combined with experimental data in references. Characteristics of crack growth behaviors were also discussed in relation to mechanical and fracture parameters.

산업용 인버터의 가속 피로수명 평가에 관한 연구 (A Study on Accelerated Fatigue Life Testing for Industrial Inverter)

  • 이상훈;김원진
    • 한국기계가공학회지
    • /
    • 제21권6호
    • /
    • pp.67-73
    • /
    • 2022
  • Industrial inverters are used in a variety of fields for electric power supply. They may be exposed to vibration and heat once they are installed. This study focused on a framework of accelerated life testing of an industrial inverter considering fatigue damage as the primary source of deterioration. Instead of analyzing detailed failure mechanisms and the product's vulnerability to them, the potential of fatigue failure is considered using the fatigue damage spectrum calculated from the environmental vibration signals. The acceleration and temperature data were gathered using field measurement and spectral analysis was conducted to calculate the vibration signal's power spectral density (PSD). The fatigue damage spectrum is then calculated from the input PSD data and is used to design an accelerated fatigue life testing. The PSD for the shaker table test is derived that has the equivalent fatigue damage to the original input signal. The tests were performed considering the combined effect of random vibration and elevated temperature, and the product passed all the planned tests. It was successfully demonstrated that the inverter used in this study could survive environmental vibration up to its guarantee period. The fatigue damage spectrum can effectively be used to design accelerated fatigue life testing.

자동차 터보충전기 터빈휠용 경량 고내열 주조 Ni기 초합금의 개발 (Development of New Ni-based Cast Superalloy with Low Density and High Temperature Capability for Turbine Wheel in Automotive Turbocharger)

  • 오키 유우타로;스미 요시노리;코야나기 요시히코
    • 한국주조공학회지
    • /
    • 제42권6호
    • /
    • pp.392-397
    • /
    • 2022
  • In order to compliant the stringent exhaust emission regulations, higher fuel efficiency and cleaner exhaust gas in combustion engines have been required. To improve combustion efficiency, an exhaust gas temperature is increasing, therefore higher temperature resistance is required for components in exhaust system, especially turbine wheel in turbocharger. IN100 looks quite attractive candidate as it has high temperature properties with low density, however it has low castability due to poor ductility at high temperature. In this study, the balance of Al and Ti composition was optimized from the base alloy IN100 to improve the high temperature ductility by expanding the γ single phase region below the solidification temperature, while obtaining the high temperature strength by maintaining the volume fraction of γ' phase equivalent to IN100 around 1000℃. Furthermore, the high temperature creep rupture life increased by adding a small amount of Ta. The alloy developed in this study has high castability, low density and high specific strength at high temperature.

원환풀내에서 Quencher Device에 의한 고온수 분출로 일어나는 혼합유동에 관한 연구 (Analysis of Flow and Thermal Mixing Responses on Hot Water Discharge by Quencher Devices into an Annular Water pool)

  • 최성석;김종보
    • 대한설비공학회지:설비저널
    • /
    • 제14권1호
    • /
    • pp.21-30
    • /
    • 1985
  • One of the problems with the Boiling Water Reactor involves the flow and thermal mixings in the suppression water pool high pressure steam discharge into the pool in case of emergency core relief. Varioos heat sensitive devices and pumps for the reactor core cooling are installed in the middle of the suppression pool. Especially the pumps utilize pool water in order to cool the reactor core in emergency cases. In this case, the water temperature for the reactor cool ins should be below a certain temperature specified by the reactor design. In the present investigation, in other to determine the optimum locations of these pumping devices, numerical solutions have been obtained for the model to determine the f low mixing characteristics. Experimental investigations have also been carried out for the flow mixing and for the thermal mixing in the pool during the discharge. Considering that the discharge steam through the Quenching Device becomes hot water immediately in the water pool, the steam- equivalent hot water has been utilized. Examining these characteristices, it becomes possible to deform me the best locations for RCIC, LPCI , HPCI pumps in the suppression water pool for the emermency reactor core cooling.

  • PDF

Coated Conductor를 이용한 소용량 영구전류스위치 시스템의 특성 해석 (Characteristics Analysis of a Small Scale Persistent Current Switch System by using Coated Conductor)

  • 김영식;윤용수;양성은;박동근;안민철;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.47-52
    • /
    • 2007
  • This paper presents characteristics analysis of persistent current switch(PCS) system on a small scale by using YBCO coated conductor(CC). A high temperature superconductor(HTS) PCS system mainly consists of a PCS, a HTS magnet load and a magnet power supply(MPS). To design the optimal heater triggering switch. the three-dimensional heat conduction model was analyzed by finite element method(FEM). The electrical equivalent model considering the n-value of CC was applied to analyze current decay during persistent current mode. In the experiment and simulation, the heater was applied with a current of 0.43A and the current was ramped up to 10A and 20A with 0.2A/s. Finally, experimental results of the HTS PCS system have been compared with the theoretical results. It has been concluded that flux creep can not influence the results because the operating current was 40% of critical current and optimal sequential operation of the PCS system is indispensable to enhance its performance.

Development of an Optimization Program for a 2G HTS Conductor Design Process

  • Kim, K.L.;Hwang, S.J.;Hahn, S.;Moon, S.H.;Lee, H.G.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권4호
    • /
    • pp.8-12
    • /
    • 2010
  • The properties of the conductor.mechanical, thermal, and electrical-are the key information in the design and optimization of superconducting coils. Particularly, in devices using second generation (2G) high temperature superconductors (HTS), whose base materials (for example, the substrate or stabilizer) and dimensions are adjustable, a design process for conductor optimization is one of the most important factors to enhance the electrical and thermal performance of the superconducting system while reducing the cost of the conductor. Recently, we developed a numerical program that can be used for 2G HTS conductor optimization. Focusing on the five major properties, viz. the electrical resistivity, heat capacity, thermal conductivity, Z-value, and enthalpy, the program includes an electronic database of the major base materials and calculates the equivalent properties of the 2G HTS conductors using the dimensions of the base materials as the input values. In this study, the developed program is introduced and its validity is verified by comparing the experimental and simulated results obtained with several 2G HTS conductors.