• Title/Summary/Keyword: heat energy balance

Search Result 333, Processing Time 0.027 seconds

The Effect of Heat Conduction resistance on Laminar Film Condensation along a Horizontal Plate (수평평판의 막응축에서 전도 열저항의 영향)

  • Lee, Euk-Soo
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.183-188
    • /
    • 2005
  • The effect of heat conduction resistance on laminar film condensation of the pure saturated vapor in forced flow over a flat plate has been investigated as boundary layer solutions. A efficient numerical methods for water are proposed for its solution. The momentum and energy balance equations are reduced to a nonlinear system of ordinary differential equations with four parameters: the Prandtl number, Pr, Modified Jacob number, $Ja^{\ast}/Pr$, defined by an overall temperature difference, a property ratio $\sqrt{P_l{\mu}_l/P_v{\mu}_v}$ and the conjugate parameter ${\zeta}$. The similarity and simplified solutions obtained reveal the effects of the conjugate parameter.

  • PDF

Analysis of Temperature Distribution of Solid and Gas in the Rotary Cooler (회전냉각기에서 고체와 가스의 온도분포해석)

  • 이만승;최주석;전철근
    • Resources Recycling
    • /
    • v.11 no.3
    • /
    • pp.25-30
    • /
    • 2002
  • Heat transfer occurring in the rotary cooler was analyzed by applying a one-dimensional steady state. The temperature of inlet gas and the measured temperature of outlet gas were used as boundary conditions. Axial temperature distribution of solid, gas and wall were calculated by solving two differential equations and two algebraic equations under the constraint of two point boundary conditions and operating conditions. The temperatures of outer wall calculated in this study were in good agreement with those measured from running rotary cooler.

Thermal Management of a Nickel/Metal Hydride Battery (Nickel/Metal Hydride 전지의 열관리기술 개발)

  • Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.8 no.4
    • /
    • pp.667-672
    • /
    • 1997
  • Thermal behavior of high capacity Nickel/Metal hybride battery in analyzed using the NISA software which is based on the three dimensional finite element method. Differential energy balance equation is used for the conduction heat transfer of the battery, while convective heat transfer equation is used for the interface between the battery and air. Heat generation rate and convective heat transfer coefficient are tested as variables to investigate thermal behavior, and the generalized equation for maximum temperature inside the battery is developed. The abrupt rise of the battery temperature due to the quick charge or discharge can be prevented from the use of metallic cooling fin. In addition, temperature augmentation of the battery is negligible when the low thermal conductive and thin insulating material is used outside of the battery case.

  • PDF

Experimental investigation of two-phase natural circulation loop as passive containment cooling system

  • Lim, Sun Taek;Kim, Koung Moon;Kim, Haeseong;Jerng, Dong-Wook;Ahn, Ho Seon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.3918-3929
    • /
    • 2021
  • In this study, we experimentally investigate of a two-phase natural circulation loop that functions as a passive containment cooling system (PCCS). The experimental apparatus comprises two loops: a hot loop, for simulating containment under severe accidents, and a natural circulation loop, for simulating the PCCS. The experiment is conducted by controlling the pressure and inlet temperature of the hot loop in the range of 0.59-0.69 MPa (abs) and 119.6-158.8 ℃, respectively. The heat balance of the hot loop is established and compared with a natural circulation loop to assess the thermal reliability of the experimental apparatus, and an additional system is installed to measure the vapor mass flow rate. Furthermore, the thermal-hydraulic characteristics are considered in terms of a temperature, mass flow rate, heat transfer coefficient (HTC), etc. The flow rate of the natural circulation loop is induced primarily by flashing, and a distortion is observed in the local HTC because of the fully develop as well as subcooled boiling. As a result, we present the amount of heat capacity that the PCCS can passively remove according to the experimental conditions and compared the heat transfer performance using Chen's and Dittus-Boelter correlation.

An Experimental Study on Evaporative Heat Transfer Characteristics in a Small Diameter Tube (미소직경관 내 증발열전달 특성에 관한 실험적 연구)

  • Hwang, Yun-Uk;Kim, Min-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.2
    • /
    • pp.216-224
    • /
    • 2001
  • Experiments have been performed to investigate evaporative heat transfer characteristics of R-134a flowing in a small diameter tube. Test section was made of stainless steel tube with an inner diameter of 2.2mm and was uniformly heated by electric current which was applied to the tube wall. The local saturation temperature of refrigerant flowing in a tube is calculated from the measured local saturation pressure by using an equation of state. Inner wall temperature was calculated from measured outer wall temperature, accounting for heat generation in the tube and one dimensional heat conduction through the tube wall. Mass quality of refrigerant flowing in a tube was calculated by considering energy balance in the pre-heater and the test section. Heat flux was varied from 19 to 64kW/$m^2$, and mass flux was chanted from 380 to 570kg/$m^2$s for each heat flux condition. From this study, heat transfer in a small diameter tube is affected by heat flux as well as mass flux for a wide range of mass quality. Heat transfer coefficient in a small diameter tube is much greater than that in medium sized tubes. Test results in this study are compared with Gungor and Winterton correlation, which gives an absolute average deviation of 27%.

Drying Characteristics of Red Peppers by Infrared Heating (원적외선 가열에 의한 고추의 건조특성)

  • Bae, Nae Kyung;Lee, Jong Bung;Sang, Hie Sun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.1
    • /
    • pp.65-71
    • /
    • 2003
  • Infrared heating has been traditionally used in industrial applications for processes such as dehydration of food industrial. This heating method involves the application of radiation in the wavelength range of 5~50 micrometers. In this work, simultaneous heat balance equations were developed to simulate the infrared radiation heating of red peppers. The equations assume that moisture diffuses to the outer boundaries of the material in liquid form and evaporation occurs at the surface of the red peppers. Energy for moisture evaporation is supplied by the infrared radiant energy. The equations were validated with experimental data on surface temperature and average moisture content of red peppers. Average deviations of predicted surface red peppers temperature and average red peppers moisture from experimental data were 323~353K and 50~80%, respectively. The spectral extinction coefficients in the wavelength range $1.5<{\lambda}<27$ micrometer at 293K for Red Peppers were determined from results of reflection measurements and the four flux radiative heat transfer calculation. The radiation extinction coefficients were obtained from effective drying factor the temperature 373K.

  • PDF

Design of Fuel Cell Power Generation System Using a Waste Heat (배열을 이용한 연료전지 발전시스템 설계)

  • Choi, Young-Jae;Jun, Jae-Ho;Jun, Joong-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.133-133
    • /
    • 2009
  • 연료전지는 연료의 화학적 에너지를 전기화학 반응을 통하여 직접 전기로 변환하기 때문에 에너지 전환효율이 높고 공해물질을 배출하지 않는 환경친화적인 고효율 발전방식으로, 특히 용융탄산염 연료전지(MCFC) 및 고체산화물 연료전지(SOFC)같은 고온형 연료전지의 경우 분산전원이나 중앙집중발전 같은 발전용에 적합한 연료전지로 평가받고 있다. 현재 MCFC 및 SOFC등의 발전용 연료전지 시스템의 효율은 약 50% 정도이며, 시스템의 발전효율을 높이기 위한 여러 연구가 진행되고 있다. 그 중에서 고온의 배열을 이용하여 연료전지 발전시스템의 효율을 향상시키기 위해 FuelCell Energy, Ansaldo Fuel Cells 및 Simens Westinghouse 등에서 수백 kW급의 fuel cell - gas turbine hybrid system에 대한 상용화 수준의 실증연구가 진행되었다. 본 연구에서는 발전용 연료전지 시스템의 발전효율을 높이기 위한 방안 중 하나로 배열을 이용하여 steam을 발생시켜 air amplifier에 사용함으로써 연료전지 시스템의 MBOP(Mechanical Balance of Plant)중 전력을 소비하는 air blower를 대체하여, 시스템 효율을 향상시키고 시스템의 가용성을 높일 수 있는 설계안에 대하여 논하고자 한다.

  • PDF

A Dynamic Simulation Model for the Operating Strategy Study of 1 kW PEMFC (가정용 연료전지 운전 모드 해석을 위한 동특성 모델 개발)

  • Yu, Sang-Seok;Lee, Young-Duk;Hong, Dong-Jin;Ahn, Kook-Young
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.4
    • /
    • pp.313-321
    • /
    • 2008
  • Dynamics of the proton exchange membrane fuel cell is specially important when the system is frequently working on transient conditions. Even though the dynamics of proton exchange membrane fuel cell for residential power generation is less critical than that of PEMFC for transportation application, the system dynamics of PEMFC for RPG can be very important for daily start-up and stop. In particular, thermal management of the PEMFC for RPG is very important because the heat generation from electrochemical reaction is delivered to the home for hot water usages. Additionally, the thermal management is also very important for heat balance of the system and temperature control of the fuel cell. The objective of this study is to develop a dynamic system model for the study of PEMFC performance over various BOP options. Basic simulation results will be presented.

Hot Leg Temperature Uncertainty due to Thermal Stratification

  • Jang, Ho-Cheol;Ju, Kyong-In;Kim, Young-Bo;Sul, Young-Sil;Cheong, Jong-Sik
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.29-35
    • /
    • 1996
  • For the Reactor Coolant System(RCS) flow rate measurement by the secondary calorimetric heat balance method, the coolant temperature of the hot leg is needed. Several Resistance Temperature Detectors(RTD) are installed in the hot leg to measure the temperature, but the average value of RTDs does not correctly represent the energy-averaged(bulk) temperature because of the thermal stratification phenomenon. Therefore some correction is introduced to predict the bulk temperature, but the correction inevitably contains uncertainty because the stratification is not defined well quantitatively yet. Therefore a large uncertainty for the correction has been used for the conservative estimation. But unrealistically large uncertainty causes degradation of the measurement method and yields difficulty to meet the acceptance criterion in start-up flow measurement test. In this paper, an analytical estimation is made on the correction and the related uncertainty using the measured hot leg velocity profile of System 80 reactor flow model test and the measured temperatures of YGN 3&4 and PVNGS 1&2 start-up tests. The results reveal that the magnitude of the correction uncertainty is much smaller than that used in the previous design. Therefore, the confidence on the flow rate measurement method can be improved and the difficulty in start-up flow measurement test can be lessened if the smaller correction uncertainty obtained through this estimation is applied.

  • PDF

Development of a System Analysis Code, SSC-K, for Inherent Safety Evaluation of The Korea Advanced Liquid Metal Reactor

  • Kwon, Young-Min;Lee, Yong-Bum;Chang, Won-Pyo;Dohee Hahn;Kim, Kyung-Doo
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.209-224
    • /
    • 2001
  • The SSC-K system analysis code is under development at the Korea Atomic Energy Research Institute (KAERI) as a part of the KALIMER project. The SSC-K code is being used as the principal tool for analyzing a variety of off-normal conditions or accidents of the preliminary KALIMER design. The SSC-K code features a multiple-channel core representation coupled with a point kinetics model with reactivity feedback. It provides a detailed, one-dimensional thermal-hydraulic simulation of the primary and secondary sodium coolant circuits, as well as the balance-of-plant steam/water circuit. Recently a two-dimensional hot pool model was incorporated into SSC-K for analysis of thermal stratification phenomena in the hot pool. In addition, SSC-K contains detailed models for the passive decay heat removal system and a generalized plant control system. The SSC-K code has also been applied to the computational engine for an interactive simulation of the KALIMER plant. This paper presents an overview of the recent activities concerned with SSC-K code model development This paper focuses on both descriptions of the newly adopted thermal hydraulic and neutronic models, and applications to KALIMER analyses for typical anticipated transients without scram.

  • PDF