• 제목/요약/키워드: heat conservative

검색결과 106건 처리시간 0.032초

열처리에 따른 복합레진 인레이의 굴곡강도에 관한 연구 (A STUDY ON FLEXURAL STRENGTH OF COMPOSITE RESIN INLAY ACCORDING TO HEAT TREATMENT)

  • 김용성;민병순;최호영;박상진;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.84-94
    • /
    • 1993
  • The purpose of this study was to evaluate flexure strength of composite resin inlay according to heat treatment and duration in comparasion with visible light-cured resin. In this study, materials were used 1 visible light-cured resin and 3 kinds of composite resin inlays. Control group was visible light cured resin (Photo Clearfil Posterior) and experimental groups were composite resin inlays (Brilliant Dentin, Brilliant Enamel and Clearfil CR Inlay). Experimental groups were divided 3 groups: First group was Brilliant Dentin and second group was Brilliant Enamel and -third group was Clearfil CR Inlay. Used experimental groups were calculated flexural strength according to heat treatment and duration. The following results were obtained: 1. Experimental groups were higher flexural strength than control group. 2. At $100^{\circ}C$ when heat treatment carried out 7 minutes flexural strength elevated third group, second group, first group in turn and when heat treatment carried out 15 minutes flexural strength elevated third group, second group, first group in turn but no difference was showed between first and second group. 3. At $125^{\circ}C$ when heat treatment was carried out 7 minutes flexural strength elevated third group, second group, first group in turn and when heat treatment was carried out 15 minutes flexural strength elevated third group, first group, second group in turn but no difference was showed between first and second group. 4. In spite of heat treatment and duration the third group was highest flexural strength in the others groups.

  • PDF

Plugger temperature of cordless heat carriers according to the time elapsed

  • Chang, Hoon-Sang;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.12.1-12.7
    • /
    • 2018
  • Objective: The purpose of this study was to measure the temperature of the plugger tip of 3 cordless heat carriers set at $200^{\circ}C$. Materials and Methods: Pluggers of the same taper (0.06, 0.08, 0.10) and similar tip sizes (sizes of 50 and 55) from 3 cordless heat carriers, namely SuperEndo-${\alpha}^2$(B & L Biotech), Friendo (DXM), and Dia-Pen (Diadent), were used and an electric heat carrier, System B (SybronEndo), was used as the control. The plugger tips were covered with customized copper sleeves, heated for 10 seconds, and the temperature was recorded with a computerized measurement system attached to a K-type thermometer at room temperature (n = 10). The data were analyzed with 2-way analysis of variance at a 5% level of significance. Results: The peak temperature of the plugger tips was significantly affected by the plugger taper and by the heat carrier brand (p < 0.05). The peak temperature of the plugger tips was between $177^{\circ}C$ and $325^{\circ}C$. The temperature peaked at $207^{\circ}C-231^{\circ}C$ for the 0.06 taper pluggers, $195^{\circ}C-313^{\circ}C$ for the 0.08 taper pluggers, and $177^{\circ}C-325^{\circ}C$ for the 0.10 taper pluggers. Only 5 of the 12 plugger tips showed a temperature of $200^{\circ}C{\pm}10^{\circ}C$. The time required to reach the highest temperature or $200^{\circ}C{\pm}10^{\circ}C$ was at least 4 seconds. Conclusion: When using cordless heat carriers, clinicians should pay attention to the temperature setting and to the activation time needed to reach the intended temperature of the pluggers.

보관조건과 열처리에 따른 복합레진의 표면경도에 관한 연구 (A STUDY ON SURFACE HARDNESS OF COMPOSITE RESINS ACCORDING TO STORAGE CONDITON AND HEAT TREATMENT)

  • 강승훈;민병순
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.194-204
    • /
    • 1994
  • The purpose of this study was to evaluate the surface hardness of composite resins according to heat treatment. storage condition and storage time. In this study. two kinds of composite resin inlays and one kind of conventional posterior composite resin were used as experimental materials. One hundred eighty composite resin specimens were constructed from composite resin inlays and conventional posterior composite resin. The conditions of this study were heat treatment. storage condition and storage time. Hardness readings were taken from the top surface of each samples using the Vickers microhardness tester(MHT-l. Matsuzawa. Japan}. The following results from this study were obtained: 1. Regardless of storage condition. both composite resin inlay and conventional posterior composite resin have a higher surface hardness under heat treatment than not. 2. Composite resins with heat treatment have a higher surface hardness under dry storage than under water immersion. 3. In case of Clearfil Photo Posterior and Brilliant Enamel with heat treatment. there was no significant difference with time. but Clearfil CR Inlay with heat treatment. there was statistical difference after 24 hours. 4. Surface hardness of composite resins with coarse hybrid type was higher than that of composite resin with fine hybrid type.

  • PDF

Infrared thermographic analysis of temperature rise on the surface of Buchanan plugger.

  • Choi, Sung-A;Hwang, In-Nam;Oh, Won-Mann
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.590.2-590
    • /
    • 2001
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spring. The System B (Model 1005, Analytic Technologies, USA) and the Buchanan pluggers of F, FM, M and ML are used for this study. The temperature was set to $200^{\circ}C$. The power level on it was set to 10. The heat control spring was touched for 1,2,3,4 and 5 seconds respectively. (omitted)

  • PDF

Continuous wave of obturation technique에서 플러거의 다양한 적용 깊이에 따른 근단부 폐쇄효율 비교 (COMPARISON OF APICAL SEALING EFFICACIES USING DIFFERENT PLUGGING DEPTH IN CONTINUOUS WAVE OF OBTURATION TECHNIQUE)

  • 이상진;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제32권6호
    • /
    • pp.491-497
    • /
    • 2007
  • 이 연구의 목적은 continuous wave of obturation technique으로 근관 충전을 할 때, 다양한 heat source plugger의 깊이에 따른 근단부 근관 폐쇄능력을 비교하는 것이었다. 직선 형태 발거 소구치를 #35/.06 크기까지 니켈티타늄 파일을 사용하여 성형 및 세정하였다. 성형과 세정이 완료된 치아를 heat source plugger의 적용 깊이에 따라 15개씩 5군으로 분류하였다. 3 mm, 4 mm, 5 mm, 6 mm, 7 mm, 양성 대조군을 제외한 모든 근관은 E&Q plus(Meta Biomed Co., Chungju, Korea)를 사용하여 #35/.06 gutta-percha cone으로 충전하였다. 모든 치아의 근첨공 주변 1 mm를 제외하고 nail varnish를 도포하였고 음성 대조군은 근첨공을 포함하여 전체 면을 도포하였다. 모든 시편을 1% 메틸렌블루 용액에 72시간 동안 보관한 다음 치근첨으로부터 1, 2, 3 mm 높이에서 수평으로 절단하였다. 각 단면을 $12.5{\times}2.5$배 현미경하에서 관찰하고 디지털 카메라로 촬영하였다. 염색제 누출 평가를 위해 aye-degree scoring system을 사용하였다. 각 절단면에서의 점수를 모두 합하여 한 시편의 점수로 사용하고 통계학적 분석을 하였다. 이 실험 조건하에서, 3-7 mm까지의 heat source plugger의 적용 깊이는 근단부 폐쇄에서 유의한 차이를 나타내지 않았다. 5-7 mm의 Buchanan's protocol을 포함한 3-7 mm를 모두 임상 적용에서 받아들여질 만하다고 보인다.

수종 복합레진의 추가적인 열중합 후의 중합률 변화 (THE CHANGES IN DEGREE OF CONVERSION OF COMPOSITE RESINS AFTER ADDITIONAL HEAT CURING)

  • 박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.827-831
    • /
    • 1995
  • This study was designed to etermine the changes in the degree of conversion for composite resins after heat curing following the methods proposed by Lee & Park(1995). 8-mm diameter hole was made in 1mm teflon plate and one of three types of composites (Charisma, Brilllant, Z100) was placed and light cured for 60seconds. The samples were devided into 3 groups according to the placing composites. After light curing, the samples were separated from the moulds. Using this method, 10 samples were prepared in each group; 5 samples from each group were heat cured according to the methods proposed by manutfactures, These samples were then thinned to 50-$70{\mu}m$ and analysed with a Fourier Transform Infrared Spectrometer. Standard baseline technique was used to calculate the degree of conversion. When the samples were light cured, the degrees of conversion in each groups were 47.1 % (charisma), 53.3% (Z100), and 70.1 % (Brilliant). The degree of conversion after heat curing were; 60.1 % (Charisma), 71.1 % (Z100), and 73.3 % (Brillant). Once the samples were heat cured, there were significant increases in degree of conversion.

  • PDF

세균액 및 세균단백질 추출물이 배양 세포에 미치는 영향 (EFFECTS OF HEAT-KILLED AND SONIC EXTRACTS OF MICROORGANISM ON CULTURED CELLS)

  • 유영대;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.606-618
    • /
    • 2000
  • Dental pulp infection is most commonly caused by extensive dental caries, and some bacterial species invade root canals; bacterial components and products are thought to be associated with the pathogenesis of periapical periodontitis. A principle driving force behind pulpal disease response appears to lie in the host immune system's to bacteria and their products. We examined the production of interleukin $1{\beta}$ (IL-$1{\beta}$) and tumor necrosis factor ${\alpha}$(TNF-${\alpha}$) from human peripheral mononuclear cells, lymphocytes and monocytes stimulated by heat-killed Acitnobacillus actinomycetemcomitans (ATCC 29523), Porphyromonas gingivalis (ATCC 33277) and Prevotella intermedia (ATCC 25611), and also by their sonicated bacterial extracts (SBE), respectively. The effects of three strains of heat-killed bacteria and their SBEs on the morphology of cultured blood cell lines HL-60 (KCLB 10240) and J774A.1 (KCLB 40067) were observed under the inverted microscope. Ultrastructural changes of J774A.1 exposed to heat-killed P. intermedia and its SBE were investigated using transmission electron microscopy. Production of IL-$1{\beta}$ was reduced in human peripheral mononuclear cells after stimulation by sonic bacterial extracts of A. actinomycetemcomitans, P. gingivalis, and P. intermedia. Heat-killed and sonic extract of P. gingivalis inhibited the production of TNF-${\alpha}$ in peripheral mononuclear cells. Production of TNF-${\alpha}$ was inhibited in peripheral monocytes after stimulation by sonic extracts of A. actinomycetemcomitans, P. gingivalis, and P. intermedia. HL-60 and J 774A.1 cells showed granular degeneration after treatment with heat-killed and sonic extracts of A. actinomycetemcomitans, P. gingivalis, and P. intermedia Chromatin margination and shrinkage were observed in 774A.1 treated with heat-killed P. intermedia. Cell wall structure and organelles were destroyed and vacuoles were formed in cytoplasm in J774A.1 treated with P. intermedia sonic extract. These results suggest that A actinomycetemcomitans, P gingivalis and P intermedia may have an important role in the formation and progression of pulpal diseases via both modulation of production of IL-$1{\beta}$ and TNF-${\alpha}$ from blood mononuclear cells and cytopathic effects.

  • PDF

복합레진 표면의 중합률 (THE RELATIVE DEGREE OF CONVERSION OF THE COMPOSITE RESIN SURFACE)

  • 박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.360-365
    • /
    • 1996
  • The purpose of this study was to evaluate the changes in the degree of conversion on a composite resin surface following heat treatment and mylar strip finishing. The effects of the time interval between the light-curing and heat-curing process were also evaluated. The composite resin surface which had been covered with a coverglass showed a lower conversion rate than the surface from which a layer of $500{\mu}m$ was ground away. The composite resin surface was definitely affected by oxygen during the heat curing process when it had not been insulated. When the composite resins were heat cured after 3 days of storage following the light curing process, the increased in the degree of conversion through heatcuring was limited.

  • PDF

광원의 종류에 따른 복합레진의 중합거동 및 중합률에 관한 연구 (THE POLYMERIZATION RATE AND THE DEGREE OF CONVERSION OF COMPOSITE RESINS BY DIFFERENT LIGHT SOURCES)

  • 류주희;이인복;유현미;김미자;석창인;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제29권4호
    • /
    • pp.386-398
    • /
    • 2004
  • Objectives: The purpose of this study was to observe the reaction kinetics and the degree of polymerization of composite resins when cured by different light sources and to evaluate the effectiveness of the blue Light Emitting Diode Light Curing Units (LED LCUs) compared with conventional halogen LCUs. Materials and Methods: First, thermal analysis was performed by a differential scanning calorimeter (DSC). The LED LCU (Elipar Freelight, $320{\;}mW/\textrm{cm}^2$) and the conventional halogen LCU (XL3000, $400{\;}mV/\textrm{cm}^2$) were used in this study for curing three composite resins (SureFil, Z-250 and AEliteFLO). Second. the degree of conversion was obtained in the composite resins cured according to the above curing mode with a FTIR. Third, the measurements of depth of cure were carried out in accordance with ISO 4049 standards. Statistical analysis was performed by two-way ANOVA test at 95% levels of confidence and Duncan's procedure for multiple comparisons. Results: The heat of cure was not statistically different among the LCUs (p > 0.05). The composites cured by the LED (Exp) LCUs were statistically more slowly polymerized than by the halogen LCU and the LED (Std) LCU (p < 0.05). The composite resin groups cured by the LED (Exp) LCUs had significantly greater degree of conversion value than by the halogen LCU and the LED (Std) LCU (p =0.0002). The composite resin groups cured by the LED (Std) LCUs showed significantly greater depth of cure value than by the halogen LCU and the LED (Exp) LCU (p < 0.05).

Flexural strength and microstructure of two lithium disilicate glass ceramics for CAD/CAM restoration in the dental clinic

  • Kang, Suk-Ho;Chang, Juhea;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • 제38권3호
    • /
    • pp.134-140
    • /
    • 2013
  • Objectives: There has been a growing interest in glass ceramic systems with good esthetics, high fracture resistance and bonding durability, and simplified fabrication techniques using CAD/CAM. The aim of this study is to compare flexural strength before and after heat treatment of two lithium disilicate CAD/CAM blocks, IPS e.max CAD (Ivoclar Vivadent) and Rosetta SM (Hass), and to observe their crystalline structures. Materials and Methods: Biaxial flexural strength was tested according to ISO 6872 with 20 disc form specimens sliced from each block before and after heat treatment. Also, the crystalline structures were observed using field-emission scanning microscopy (FE-SEM, Hitachi) and x-ray diffraction (XRD, Rigaku) analysis. The mean values of the biaxial flexural strength were analyzed by the Mann-Whitney U test at a significance level of p = 0.05. Results: There were no statistically significant differences in flexural strength between IPS e.max CAD and Rosetta SM either before heat treatment or after heat treatment. For both ceramics, the initial flexural strength greatly increased after heat treatment, with significant differences (p < 0.05). The FE-SEM images presented similar patterns of crystalline structure in the two ceramics. In the XRD analysis, they also had similar patterns, presenting high peak positions corresponding to the standard lithium metasilicate and lithium disilicate at each stage of heat treatment. Conclusions: IPS e.max CAD and Rosetta SM showed no significant differences in flexural strength. They had a similar crystalline pattern and molecular composition.