• 제목/요약/키워드: heat change

검색결과 3,576건 처리시간 0.032초

밀폐용기내에서 초음파 진도에 따른 상변화물질의 용융현상 연구 (An Experimental Study on melting phenomena of PCM affected by Ultrasonic Vibration in a square cavity)

  • 윤정환;정대훈;오율권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.246-251
    • /
    • 2001
  • Solid-liquid phase change (i.e. melting or solidification) occurs in a number of situations of practical interest. Some common examples include the melting of edible oil, metallurgical process such as casting and welding, and materials science applications such as crystal growth. Therefore, due to the practical importance of the subject, there have been a large number of experimental and numerical studies of problems involving phase change during the past few decades. Also, this study presented the effective way to enhance phase change heat transfer.

  • PDF

히트파이프를 사용한 태양열 축열시스템의 성능모사 및 해석 (Performance Simulation and Analysis of the Solar Thermal Storage System Using Heat Pipe)

  • 정의국;부준홍;김종규;강용혁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.80-85
    • /
    • 2009
  • Mathematical modeling and performance simulation results were shown for the solar thermal storage system which used heat pipe. The thermal storage system was composed of thermal storage tank and charging/discharging heat exchanger with one by the heat pipes. Heat pipe heat exchanger was attached to system, and could carry out charging and discharging to thermal storage tank at the same time. Height of the thermal storage tank was 600 mm, and that of the charging/discharging heat exchanger was 400 mm. Length of the heat pipe was the same as the total height of thermal storage system, and outer and inner diameter were 25.4 mm(O.D.) and 21.4 mm(I.D.) respectively. Diameter of the circular was 43 mm(O.D.), and fin geometries were considered as the design parameters. High temperature phase change material(PCM), $KNO_3$ and low temperature PCM, $LINO_3$ were charged to storage tank to adjust working temperature. Total size of thermal storage system able to get heat capacity more than 500 kW was calculated and the results were shown in this study. Number of heat pipe was required more than maximum 500, and total length of thermal storage system was calculated to the more than maximum 3 m at various condition.

  • PDF

LPG 정적연소실내 점화특성에 관한 연구 (A Study on the Ignition Characteristics at Constant Volume Combustion Chamber of LPG)

  • 박경석
    • 한국자동차공학회논문집
    • /
    • 제12권3호
    • /
    • pp.75-82
    • /
    • 2004
  • The allowable exhaust standard has been intensified as a part of the countermeasure to decrease air pollution in the world. As the cars with an alternative fuel starts to get into the spotlight, the cars with low emission has been introduced and exhaust gas regulation forced in this country. These days, LPG vehicles, which infrastructure of fuel was already built up, and CNG vehicles are recognized for alternative fuel cars in this country. In this study, the constant volume combustion chamber was manufactured and used for experiments to obtain the ignition characteristics of LPG fuel and the optimal ignition energy. The experiment measured the combustion characteristics, in regard to the change of combustion variable, and the change of ignition energy. During the combustion of fuel, the maximum temperature inside the combustion chamber is higher when the initial pressure is higher. The burning velocity also seems to have the same characteristic as the temperature. However, the heat flux did not change much with the theoretical correct mixture but the various initial temperature of the combustion chamber. The heat flux got faster and ignition energy bigger as the dwell time of the ignition system expanded. When the dwell time get longer, the ignition energy also increased then fixed. The ignition energy increased as the initial pressure inside the combustion chamber higher. The heat flux got faster as the dwell time expanded.

기초자치단체의 폭염으로 인한 온열 및 심뇌혈관질환 부담 (Municipal Disease Burden Attributable to Heat Wave)

  • 이수형;신호성
    • 보건교육건강증진학회지
    • /
    • 제31권4호
    • /
    • pp.51-62
    • /
    • 2014
  • Objectives: The objective of study was to calculate the municipal level environmental burden of disease (EBD) due to heat wave. Methods: The data used were Korea National Health Insurance 2011 claim data and 2011 death registry. Heatwave related diseases included hypertensive heart diseases, ischemic heart diseases, cerebrovascular disease, and heat related illness. According to the method that WHO proposed, the study computed population-attributable fraction with relative risk which come from previous study and proportion of exposure which the study calculated with historical meteorology data. Results: The Average of 251 municipal EBD was 2.11 per thousand persons. The value of years lost due to disability was 11 times higher than that of years of life lost. On average EBD of county and southern geographical areas tended to be higher than those of District or city areas. The relationship between municipal deprivation index (composite deprivation index) and EBD showed the positive association, which means that the worse deprived municipal is, the higher EBD takes. Conclusions: Climate change is getting one of the major risk factors of cardio-cerebrovascular disease, which is the second leading cause of death. The study results suggested the urgent policy planning and reaction of climate change adaptation.

An Experimental Study of Accelerating Phase Change Heat Transfer

  • Oh, Yool-Kwon;Park, Seul-Hyun;Cha, Kyung-Ok
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1882-1891
    • /
    • 2001
  • The present paper investigated the effect of ultrasonic vibrations on the melting process of a phase-change material (PCM). Furthermore, the present study considered constant heat flux boundary conditions unlike many of the previous researches adopted constant wall temperature conditions. Therefore, in the present study, modified dimensionless parameters such as Ste* and Ra* were used. Also, general relationships between melting with ultrasonic vibrations and melting without ultrasonic vibrations were established during the melting of PCM. Experimental observations show that the effect of ultrasonic vibrations on heat transfer is very important throughout the melting process. The results of the present study reveal that ultrasonic vibrations accompany the effects like agitation, acoustic streaming, cavitation, and oscillating fluid motion. Such effects are a prime mechanism in the overall melting process when ultrasonic vibrations are applied. They enhance the melting process as much as 2.5 tildes, compared with the result of natural melting. Also, energy can be saved by applying ultrasonic vibrations to the natural melting. In addition, various time-wise dimensionless numbers provide conclusive evidence of the important role of ultrasonic vibrations on the melting phenomena.

  • PDF

수직 액막 흡수관의 유동변화에 따른 흡수성능 변화에 관한 해석적 연구 (Numerical Study on the change of Absorption Characteristics by Change of Flow pattern in the Vertical Falling Film Absorber)

  • 김정국;조금남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.90-96
    • /
    • 2003
  • Numerical analyses have been performed to obtain the absorption heat and mass transfer coefficients and the absorption mass flux from a falling film of LiBr solution. In the present study, the behavior of laminar-wavy falling film in the vertical absorber was studied analytically and experimentally. The change of absorption performance on mean film thickness, wave amplitude, wave celerity was analysed. The heat and mass transfer equations are solved simultaneously to give the temperature and concentration variations at the LiBr solution/refrigeration vapor interface and at the wall. Effects of uniform film, wavy film and film Reynolds number on the heat and mass transfer coefficients have been estimated. The analytical results of the uniform and wavy falling film in the bare tube was higher than experimental result for $Rd_{t}<100$. The absorption performance showed the maximum at the wavy film by the insert device(spring).

  • PDF

응력제거 열처리한 Mg-AZ31B 합금 TIG 용접부의 기계적 특성과 미세조직 변화에 미치는 용접조건의 영향 (The Influence of Welding Conditions on Mechanical Properties and Microstructural Change of TIG Welded Joint in Stress Relieve Heat Treated Mg-AZ31B Alloy)

  • 김용길;정동석;배차헌
    • 열처리공학회지
    • /
    • 제17권4호
    • /
    • pp.230-235
    • /
    • 2004
  • Present work was carried out to investigate the influence of welded conditions, such as welding current, diameter of welding wire on the microstructural change and mechanical properties of TIG welded joint in AZ31B Mg alloy. It was found that good and sound welded joint was achieved in all welding conditions. The grain size decreased with increasing welding current and decreasing diameter of welding wire. Also, the second phases were homogeneously distributed in the grain and grain boundary as decreasing welding current and diameter of welding wire. The ${\beta}$ discontinuos precipitates were observed in the welded joint, but this microstructure has not been reported by previous researchs in AZ31B Mg alloy. The hardness value is affected by the existence state of the second phase and the hardness of the welded joint region is lower than the other regions in welded AZ31B Mg alloy. The strength of the welded joint region was influenced by the grain size and has more than 90%, compared to that of ASTM standard specification.

잠열축열시스템의 축열과정에서 자연대류의 영향에 관한 연구 (Effect of Natural Convection on the Heat Transfer in a Latent Heat Storage System)

  • 유승남;한귀영
    • 태양에너지
    • /
    • 제19권2호
    • /
    • pp.29-36
    • /
    • 1999
  • Heat transfer characteristics of a low temperature latent heat storage system during the heat storage stage was examined for the circular finned tubes using fatty acid which shows the big density difference during melting as phase change materials. The heat storage vessel has the dimension of 530 mm height, 74 mm inside diameter and inner heat transfer tube is 480 mm in height and 13.5 mm outside diameter. Hot water was employed as the heat transfer fluid. During the heat storage stage, it was found that both conduction and natural convection were the major heat transfer mechanism. It was also found that the effect of natural convection on the heat transfer was more significant for the unfinned tube system than that for the finned tube system. The experimentally determined overall heat transfer coefficients were in the range of $50{\sim}250W/m^2K$ and the correlation for natural convection heat transfer as a function of Nusselt and Rayleigh number was proposed.

  • PDF

해수 열원 및 폐열 이용 고성능 열펌프 시스템 모사 (Simulation for High Efficient Heat Pump System using Seawater Heat Source and Exhaust Energy)

  • 최광일;오종택;오후규
    • 설비공학논문집
    • /
    • 제15권1호
    • /
    • pp.59-66
    • /
    • 2003
  • The purpose of this study is to analyze the characteristics (COP) of the heat pump system for various operating conditions with the use of seawater heat source and exhaust energy. To accomplish the goal, first of all, the computer simulation for heat pump system is carried out. The heat pump system model is made of a waste heat recovery system and a vapor compression refrigeration system, and the working fluid is R-22. The model calculated the change of COP with the variation of temperature and flow rate. The COP and the plate heat exchanger (PHE) area of the heat pump system are considered moderately high in the condensation temperature of $25^{\circ}^C$ and the evaporation temperature of $2^{\circ}^C$ in indoor culture system. The simulation results will be used effectively for the design and the performance prediction of heat pump system using unused energy in a land base aquaculture system.

원통다관형 열교환기의 가로막 개수에 관한 연구 (A study of number of baffle on shell and tube heat exchanger)

  • 김순영;이육형;박명관
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.635-638
    • /
    • 2000
  • The propose of study analyze a TEMA(Tubular Exchanger Manufacturers Association) E shell and tube heat exchanger performance with 3, 5, 7, 9, 11 baffles and 16, 20 tubes. In this investigate measured a variation of the heat exchanger cooling capacity change within each number of baffle and tube number and determined optimal number of baffle. designs for industry applications are optimized using the analysis of test results.

  • PDF