• Title/Summary/Keyword: heat Adaptation

Search Result 149, Processing Time 0.03 seconds

Farmers' Perceptions and Knowledge of Cattle Adaptation to Heat Stress and Tick Resistance in the Eastern Cape, South Africa

  • Katiyatiya, C.L.F.;Muchenje, V.;Mushunje, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.11
    • /
    • pp.1663-1670
    • /
    • 2014
  • The objective of this study was to determine the perceptions and knowledge of farmers of heat stress and tick resistance in cattle. A cross-sectional survey was conducted and 110 farmers in four villages in the sour and sweet velds of the Eastern Cape Province, South Africa were interviewed. The associations among area (municipality), gender, age, level of education, employment and religion were computed using Chi-square tests. The majority of the respondents had on average 4 bulls, 4 cows, 4 heifers, 4 calves, and 4 oxen. Milk was considered as the major (28.3%) reason for keeping cattle. Most farmers owned non-descript (72.6%), and Nguni (45.3%) cattle because of their heat tolerance (54.7%), tick resistance (54.7%), and milking ability (28.2%) traits. Excessive panting (56.6%) and disease transmission (76%) were regarded as the major effects of heat stress and tick infestation in cattle, respectively. About 50% of the respondents agreed that hair length influences tick resistance and 47.17% considered coat colour when acquiring cattle. In the sampled areas, ticks were prevalent in the summer season (93%), and 77.36% of the respondents use acaricides every fortnight. Gall sickness was reported to be a major problem in the cattle herds by 36.79% of the respondents. Our results showed that farmers in the two municipalities had knowledge of cattle adaptation to heat stress and tick resistance.

Effects of heat stress on performance, physiological parameters, and blood profiles of early-fattening Hanwoo steers in climate chambers

  • Jun Sik Woo;Na Kyun Lee;Hong Gu Lee;Keun Kyu Park
    • Animal Bioscience
    • /
    • v.37 no.1
    • /
    • pp.142-150
    • /
    • 2024
  • Objective: This study was conducted to assess effects of heat stress on growth performance, physiological parameters, and blood profiles of Hanwoo steers during early-fattening period in climate chambers. Methods: Four Hanwoo steers (body weight, 454.3±10.9 kg; age, 14±0.1 month) were allocated into four levels of temperature-humidity index (THI) in a 4×4 Latin square design for 21 days (pre-adaptation, 7 d; heat stress, 7 d; post-adaptation, 7 d) per period. Experimental treatments were assigned according to THI chart based on National Institute Animal Science (NIAS, 2022): Comfort (25.5℃ to 26.5℃, 60%; THI 73 to 75), Mild (28℃ to 29℃, 60%; THI 77 to 79), Moderate (29.5℃ to 30.5℃, 80%; THI 82 to 84), and Severe (31℃ to 32℃, 80%; THI 85 to 86) in separate climatic controlled chambers. Results: The dry matter intake (DMI) of the formula feed was lower in Severe compared to Mild and Comfort (p<0.05). The DMI of rice straw was the lowest in Severe and lower in Moderate than Comfort and Mild (p<0.05). Both average daily gain and feed conversion ratio of Severe and Moderate were lower than those of Mild and Comfort (p<0.05). Water intake was the highest in Severe and lower in Moderate compared with Comfort and Mild (p<0.05). Heart rate and rectal temperature increased as THI level increased (p<0.05). Glucose was the lowest in Severe and lower in Moderate compared to Comfort (p<0.05). On the contrary, non-esterified fatty acid was the highest in Severe and lower in Moderate compared with Comfort (p<0.05). Blood urea nitrogen of Moderate and Severe were higher than those of Comfort and Mild (p<0.05). Cortisol increased as THI increased (p<0.05). Conclusion: This study demonstrated the negative effects of heat stress on the performance and physiological responses of Hanwoo steers during the early-fattening period. In addition, it is judged that the THI chart for Hanwoo steers of National Institute of Animal Science (2022) was properly calculated.

Physiological Properties of Lactobacillus acidophilus 30SC Exposed to Heat Shock Stress (Heat Shock Stress에 의한 Lactobacillus acidophilus 30SC의 생리적 특성)

  • Moon, Yong-Il;Han, Soo-Min;Park, Dong-Jun;Chi, Youn-Tae;Kim, Kwang-Hyun;Oh, Sejong
    • Food Science of Animal Resources
    • /
    • v.25 no.3
    • /
    • pp.350-356
    • /
    • 2005
  • We examined the enhancement of thermotolerance for storage conferred on Lactobacillus acidophilus 30SC by adaptation to different stresses. The viable cells of Lactobacillus acidophilus 30SC were compared with their viability prior to heating at $45,\;55^{\circ}C\;and\;60^{\circ}C$. Heat-adapted ($45^{\circ}C$ for 15 min) L. acidophilus 30SC in MRS broth exhibited higher survivability at lethal temperature of $55^{\circ}C$ than control. Cellular protein profiles of L. acidophilus 30SC during heat adaptation were examined with SDS-PAGE, and scanning electron microscopy. When L. acidophilus 30SC was heat-adapted at $55^{\circ}C$ for 15min, 5 new protein spots of ca $8\~45\;kDa$ size were observed on 2D SDS-PAGE. It was presumed that new proteins of L. acidophilus 30SC were produced to adapt to the environment of higher growth temperature.

Diagnosis of Office Occupant's Adaptation Level for Thermal Environment (사무실 근무자의 온열환경에 대한 적응수준 진단)

  • Kim, Yang-Weon
    • Korean Journal of Human Ecology
    • /
    • v.12 no.5
    • /
    • pp.747-754
    • /
    • 2003
  • The actual clothing conditions were surveyed to diagnose clothing condition of Korean female in the view point of the adaptation to the thermal environment according to seasonal changes. Then, clothing microclimate, physiological responses, and subjective sensation were investigated through wearing trials on human body in climatic chamber based on the results from the survey. Factors to evaluate validity of clothing condition were clothing weight, clothing microclimate, physiological response of human body, and subjective sensation. The results were as follows: 1. Clothing weight per body surface area of the season was $856g/m^{2}$, $439g/m^{2}$ in summer, $630g/m^{2}$ in fall, and $1184g/m^{2}$ in winter. Cold - resistance of Korean female in office was superior to Japanese, inferior to residents of rural areas of Korea, and similar to male in office. However, in heat - resistance, female in office was inferior to residents of rural areas of Korea. 2. In spring, fall, winter, clothing microclimate temperature was a little higher than that in summer. Therefore, it was not a desirable wearing condition even though the clothing microclimate was comfortable zone. 3. Mean skin temperature of female in office was including within the range of Winslow's comfortable zone, but the range of comfortable zone in mean skin temperature of female was more narrow than Winslow's. Thus, it has problem for female to adaptation to thermal environment.

  • PDF

A study on the risk assessment of climate crisis adaptation measures in public sewage treatment facilities (공공하수처리시설의 기후위기 적응대책 위험도 평가 연구)

  • Jaekyung Choi;Younsun Lee;Sunghwan Hwang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.2
    • /
    • pp.61-68
    • /
    • 2024
  • In the context of the Ministry of Environment's 2022 Climate Change Adaptation Plan for Public Institutions, public sewage treatment plants are one of the important targets for climate change response aimed at sustainable water management. In this study, it is applied a modified methodology to four water regeneration centers (public sewage treatment facilities) in charge of sewage treatment in Seoul to analyze the impacts and risks of climate change and discuss priorities for adaptation measures. The results of the study showed that heavy rains, heat waves, and droughts will be the key impacts of climate change, and highlighted the need for measures to mitigate these risks, especially for facility managers.

Scientific exploration on physiological basis of Svedana Karma (Sudation): A clinical application of heat stress.

  • Yadav, Saurabh;Verma, Vandana;Abhinav, Abhinav
    • CELLMED
    • /
    • v.9 no.3
    • /
    • pp.4.1-4.8
    • /
    • 2019
  • Now researchers have focused attention on exploring the mechanism of acute responses of heat stress given in heat therapy that ultimately promotes the long term health benefits. Heat therapy is not a new idea rather it was practiced since thousands years back in the form of hot bath, sauna bath, steam room. Similarly in Ayurveda there is very comprehensive description of heat therapy in the form of Svedan karma (Sudation therapy). Svedan is a process to induce sweating artificially in a patient who had already undergone Snehan. Svedan is applied for purification of body, as well as in management of various disorders originated due to vitiation of Vata, Kapha Dosha, Meda Dhatu and musculoskeletal disorders. It produces various beneficial effects by augmenting the Agni like clears the channels, liquefies the deposited Dosha, regulates Vata Dosha, helps in removal and pacification of Dosha, augments metabolism (Agni Deepan), increases appetite, flexibility in body parts, softness and shining of skin, removes coldness, stiffness, drowsiness, improves joint motility. However, Svedana karma is vastly used by Ayurveda Physicians in treatment of various disorders but the mechanisms of beneficial effects produced by Svedan Karma are yet not completely explored on scientific basis. In this article, we will discuss and try to establish a possible mechanism of action of Svedana karma in relation to heat stress, mitochondrial adaptation, heat shock protein (HSP) and glucocorticoids as these are secreted under stressful conditions.

Molecular cloning of metal-responsive transcription factor-1 (MTF-1) and transcriptional responses to metal and heat stresses in Pacific abalone, Haliotis discus hannai

  • Lee, Sang Yoon;Nam, Yoon Kwon
    • Fisheries and Aquatic Sciences
    • /
    • v.20 no.7
    • /
    • pp.9.1-9.13
    • /
    • 2017
  • Background: Metal-responsive transcription factor-1 (MTF-1) is a key transcriptional regulator playing crucial roles in metal homeostasis and cellular adaptation to diverse oxidative stresses. In order to understand cellular pathways associated with metal regulation and stress responses in Pacific abalone (Haliotis discus hannai), this study was aimed to isolate the genetic determinant of abalone MTF-1 and to examine its expression characteristics under basal and experimentally stimulated conditions. Results: The abalone MTF-1 shared conserved features in zinc-finger DNA binding domain with its orthologs; however, it represented a non-conservative shape in presumed transactivation domain region with the lack of typical motifs for nuclear export signal (NES) and Cys-cluster. Abalone MTF-1 promoter exhibited various transcription factor binding motifs that would be potentially related with metal regulation, stress responses, and development. The highest messenger RNA (mRNA) expression level of MTF-1 was observed in the testes, and MTF-1 transcripts were detected during the entire period of embryonic and early ontogenic developments. Abalone MTF-1 was found to be Cd inducible and highly modulated by heat shock treatment. Conclusion: Abalone MTF-1 possesses a non-consensus structure of activation domains and represents distinct features for its activation mechanism in response to metal overload and heat stress. The activation mechanism of abalone MTF-1 might include both indirect zinc sensing and direct de novo synthesis of transcripts. Taken together, results from this study could be a useful basis for future researches on stress physiology of this abalone species, particularly with regard to heavy metal detoxification and thermal adaptation.

A Preliminary Analysis of the Impact of Urban Green Spaces on the Urban Heat Island Effect Using a Temperature Map

  • Myeong, Soo-Jeong
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.6
    • /
    • pp.675-680
    • /
    • 2010
  • Temperature is one of the main issues in climate change, and the urban heat island effect in highly developed urban areas is an important issue that we need to deal with. This study analyzed the extent of the cooling effects of urban green spaces. The study used a surface temperature map of Seoul. It found that the cooling effects of green space was observed within limited distances, although it varied a little depending on the parks investigated. The cooling effect distance ranged from 240m to 360m, averaging about 300m. It also found the size of an urban green space does not make much difference in cooling the surrounding areas. Although further investigation with diverse urban areas should be conducted on this matter, the results did imply that many small green spaces in the neighborhood are more effective than a single big green space in mitigating the heat island effects of cities.

Absorption cooling R&D in Europe

  • Kuhn, A.;Petersen, S.;Riebow, D.;Sahin, D.;Ziegler, F.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.3
    • /
    • pp.50-57
    • /
    • 2004
  • This article reviews absorption cooling R&D in Europe from the viewpoint of fundamentals, cycle development and applications. The review contains information on R&D, predominantly of public projects in the field of sorption cooling. We report on research which is performed in Europe with some stress on Germany. There is progress in fundamentals, thermodynamic cycle design, and also applications. In the fundamentals part the discussion about thermodynamics, working pairs, and heat and mass transfer is reflected. Today's discussion on thermodynamic cycles is not very strong. Main focus is on special solid sorption cycles, compression­sorption hybrids, and open cycles, In the applications part the chilling business is the main issue. Some interest is given to the improvement of efficiency on and the adaptation to low temperature waste heat use, but the stress is on the use of solar energy as heat source. The area of heat pumping for heating purposes is less prominent but not at all negligible. Finally, industrial heat pumping involves the reverse cycle (heat transformer, heat pump type Ⅱ) also, but there is no significant activity.

  • PDF

Selection of Green Roof Initiative Zone for Improving Adaptation Capability against Urban Heat Island (도시열섬 적응능력 제고를 위한 옥상녹화 중점지역 선정 방안)

  • Park, Eun-Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.1
    • /
    • pp.135-146
    • /
    • 2014
  • The improvement of adaptation capability against heat island (ACHI) by greening buildings is considered as an important measure to cope with a climate change. This study aimed to select the most appropriate zones for green roof initiative in case study sites, Bucheon, Anyang, and Suwon Cities and to investigate the characteristics of buildings for greening to improve ACHI. Relative ACHI for each lot was estimated from 0 to -9, assuming that it decreases with the distance from green space and waterbody. Low adaptation capabilities were mostly shown in the old urban blocks with dense low-rise buildings and lack of green space. Three blocks with the lowest ACHIs were chosen as a green roof initiative zone in each city. They are largely residential areas including low-rise buildings such as single, multi-household houses, townhouses, 5 or lower story apartments and few are industrial areas crowded with small factory buildings. The areas of building roof available for greening are 8.8% within the selected zones in Bucheon City, 5.3% in Anyang City, and 4.9% in Suwon City. As it were, 25.2~41.7% of the roof top areas are available for greening in these zones. It means that roof top areas of $25,000{\sim}120,000m^2$ can be used for greening within the selected zones of $0.64{\sim}1.65km^2$ to improve ACHI. The approach and results of the study are significant to provide a logical basis and information on location, scale, effect, and target figure of greening as a measure to cope with climate change.